Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC RAM NAGAR NEW BUS STAND NARWANA 126116 | NARWANA | JIND | HARYANA | 126116 | ₹1.6 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹1.7 Cr+₹3.1 L (1.90%)Rejected-Finance NEAR WARD NO 15 CHHABRA COLONY NEAR NEW BYE PASS ASANDH 132039 HARYANA | KARNAL | HARYANA | 132039 | ₹1.7 Cr+₹3.1 L (1.90%) | L2 | Rejected-Finance high rate |
| 3 | L3₹1.9 Cr+₹27.2 L (16.5%)Rejected-Finance HOUSE NO 953 SECTOR 23 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI | BHIWANI | BHIWANI | HARYANA | ₹1.9 Cr+₹27.2 L (16.5%) | L3 | Rejected-Finance high rate |
Tender Value
₹1.9 Cr
EMD Value
₹3.7 L
Closing Date
7 Mar 2022, 5:00 pmClosed
Executive Engineer Safidon WS Division Safidon
Executive Engineer Safidon WS Division Safidon
Laying Underground RCC NP3 Pipeline for dewatering flood water from Dabar area of Village Malsari Khera
2022_HRY_208128_1
RCC NP3 Pipeline Village Malsari Khera
Open Tender
Civil Works
Works
120 days
Executive Engineer Safidon WS Division Safidon
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹3.7 L
Yes
13 Apr 2022
14 Feb 2022
8 Mar 2022
14 Feb 2022
7 Mar 2022
14 Feb 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge HSR 4.12.1
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix M-10 and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping ofR.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of theEngineer-in charge. (Note :- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix).all works upto plinth level. M-1O grade plain cement concrete(cement content considered @ 220kg/cum) HSR Item no. 6.22.2.3
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix andM-15 grade plain cement concrete (cement content considered @ 240 kg/cum) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge HSR 6.22.2.2
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1 :3 (1 cement : 3 coarse sand
Design mix cement concrete of grade M-25 with minimum cement contents 330 Kg/Cum in foundation and plinth HSR Item No 6.25
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns HSR 6.29.1
Cement plaster 10 mm thick in cement plaster mortar 1:3 plus 1 mm thick cement grouting ( derived rate )
Supply of cold twisted deformed (ribbed/tor steel) bars for RCC works where not included in the complete rate of RCC i/c bending, binding and placing in position complete (HSR item No. 6.34.3)
Providing lowering cutting jointing and testing RCC 900MM dia pipe class NP3 as perIS-458-2003 with spigot & socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if requiredjointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socketjoints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, & item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being:hsr 21.95.8
Providing and Lowering 225 mm outer dia UPVC pipe threaded (10kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge HSR 20.91
Providing and fixing UPVC cap for 225mm outer dia UPVC pipe (10kg/cm2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge HSR 20.94
SAWARIA ENGINEERING INDIA PVT LTD
MAHA LAXMI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .