Loading…
Loading…
| # | Company | Quoted % |
|---|---|---|
| 1 | +4.44% | |
| 2 | +0.07% |
Tender Value
₹3.3 Cr
EMD Value
₹1.7 L
Closing Date
3 Jun 2026, 5:00 pmClosed
MR SURAJ KUMAR SEN(DFLT)
CE(Raipur)
CONSTRUCTION OF SUNDARKERA TO JAWAIBANDHA ROAD LENGTH 2.42 KM, I/C. CULVERTS AT DISTT.- RAIPUR (C.G.) DN. NO.3 , NAVA RAIPUR).
190673
NIT NO: 217/TC/2026-27
RESTRICTED TENDER
WORKS
PERCENTAGE
3 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR SURAJ KUMAR SEN(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Raipur)
PWD Circle-1,Raipur
Pwd Div No3 Raipur
120
03
No
0
190673
3 Jun, 2026 5:00:00 PM IST
8 Jun, 2026 10:00:00 AM IST
13 May, 2026 5:00:00 PM IST
NIT NO: 217/TC/2026-27
CONSTRUCTION OF SUNDARKERA TO JAWAIBANDHA ROAD LENGTH 2.42 KM, I/C. CULVERTS AT DISTT.- RAIPUR (C.G.) DN. NO.3 , NAVA RAIPUR).
166900.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
33362000.00
2
5 Jun, 2026 5:00:00 PM IST
33362000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
7 documents required · 6 mandatory · 1 optional
₹0
₹1.7 L
3 Jun 2026
13 May 2026
8 Jun 2026
13 May 2026
5 Jun 2026
Clearing and grubbing Clearing and grubbingROAD land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200. In area of light jungle
Compacting Original Ground Compacting Original Ground supporting embankment Loosening, leveling and compacting original ground to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at O.M.C. and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction.
Excavation in Soil (by Mechanical Means.) Excavation forROADway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Construction of Embankment with Material Deposited fromROADway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site fromROADway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 (A) Plant mix method (with Mechanically crushed stone only) (a) For Lower Sub-base with (i) Grading- III Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing ofROAD surface and spraying primer using mechanical means as per clause 502. on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii) Granular surfaces treated with primes @ 0.30 kg /Sqm
Dense Bituminous Macadam (Providing and laying dense bituminous macadam with minimum 40-60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No.505 complete in all respects.) A With sensor paver finisher (ii) for Grading-II(26.5 mm nominal size bitumen content 4.50%)
Bituminous Concrete (Providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.0 to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects) A With sensor paver finisher (iii) for Grading II (13.2 mm nominal size) with bitumen 6.0 %
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across theROAD ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. (i) Single row for one utility service.
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer Stone (precast)
Hectometer Stone (precast)
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thickness supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and painting all components of the signs and supports as per clause 7.2 of IRC:67-2012) Made of Class-A High Intensity Super Engineering Grade Sheeting of Type II (for ODR & VillageROADs) With Aluminum Sheeting of 2 mm thickness 900 mm equilateral triangle
With Aluminum Sheeting of 1.5 mm thickness 600 mm equilateral triangle
600 mm circular
600 mm X 500 mm rectangular (for chevron)
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorized sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area not exceeding 0.9 sqm and fixed on a mild steel back frame of ISA 40 x 40x 5 mm, supported on a mild steel single angle iron post of size 75 x 75 x 6 mm,firmly fixed to the ground with M15 grade cement concrete 45 x 45 x 60cm, 60cm below ground level as per approved drawing) (C) Made of Class-A High Intensity Micro Prismatic Grade Sheeting of Type I (for ODR & VillageROADs)
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC:67-2012 made of retro-reflective type sheeting and vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm and fixed on a mild steel frame of size 40 x 40 x 5 mm,supported on a 2 Nos.mild steel angle iron post 75mm x 75mm x 6mm, 2 Nos. firmly fixed to the ground with M15 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing) (C) Made of Class-A High Intensity Micro Prismatic Grade Sheeting of Type I (for ODR & VillageROADs)
Providing & Fixing Delineator made of M.S. Hollow Rectangular Pipe (Conforming to IS: 4923) of cross section 96mmx 48mm of 1.20 meter length. The top of the hollow pipe, welded and closed with 16 gauge M.S. Sheet. The height of the Delineator above ground level should be between 0.8 meter and 1.0 meter. The bottom of the delineator should be provided with holdfast of length 15cm on each side. Delineator should be painted with coat of Zinc Chromate stoving Prime and two coats of Black Stove Enamel (Oven Baked) paint with 3nos. 15 cm bands of white Retro-reflective Sheeting of Engineering Grade pasted around the pipe and 2 Nos. High intensity Grade Retro-reflective Sheeting of size 8 cm x 10cm pasted on the top of each side of Delineator and treated With HLVA & fixing the same in M-15 grade concrete block of size 30x30x30cms including transportation etc. complete. The construction and placement of the delineator must be as per IRC: 79.
Providing & Fixing Hazard Marker Type-2 Partial Retro Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS:2062 Painted with one cast of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm bands of yellow Retro- Reflective Sheeting of Engineering Grade pasted a per IRC:79 including one MS angle Iron post of size 50x50x5 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30x30x30cm, including transportation etc. Complete.
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. I Ordinary soil (i) Upto 3 m depth
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) B 600 mm dia
Plain cement concrete complete as per drawing and Technical Specifications (ii) PCC Grade M 15
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. (A) Using concrete mixer. (i) PCC Grade M15
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. (A) Using concrete mixer. (vi) PCC Grade M25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). D Height upto 5m (a) Using concrete Mixer (b) (ii) R.C.C. Grade M-25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bars reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. (i) Granular material
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200.
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200.
Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.
Construction of RCC Drain/Cover/Chamber (ii) Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Construction of RCC Drain/Cover/Chamber - Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets (D) 1000 mm dia.
boq_comp_chart.xls
BOQ Comparative Chart • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
310909727681151724_152662_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
2893966126701356405_190673_Form A.doc
NIT • 0.15 MB
8382920486233180595_190673_NIT.doc
NIT • 0.31 MB
1799559676686999057_190673_Notice.docx
NIT • 0.04 MB
2122084407978986775_190673_BOQ.xls
BOQ • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .