Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹52.1 LAccepted-AOC WARD NO 1 DHEMAJI TOWN DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | 1 | Accepted-AOC ACCEPTED | |
| 2 | 2₹55.1 L+₹3.0 L (5.83%)Rejected-AOC BHARALICHUK DHEMAJI ASSAM | DHEMAJI | DHEMAJI | ASSAM | 2 | Rejected-AOC REJECTED | |
| 3 | Rejected-Technical VILL HATIGARH P O HATIGARH P S DHEMAJI DIST DHEMAJI PIN 787057 | DHEMAJI | ASSAM | 787057 | - | Rejected-Technical NOT RESPONSIVE |
Tender Value
₹54.8 L
EMD Value
₹1.1 L
Closing Date
4 Mar 2024, 1:00 pmClosed
SUPERINTENDING ENGINEER
LAKHIMPUR BUILDING CIRCLE, NORTH LAKHIMPUR
Construction of Carpenter yard, construction of R.C.C Filter and Reservoir, Repairing of Existing building to be used as Carpenter workshop and water supply and sanitary installation to 5 Nos. of practical yard at CSTC, Gogamukh, PHASE III
2024_PWBNH_36673_1
LBCNL/2023-24/Dhemaji/D-08
Open Tender
Civil Works - Building
Item Rate
180 days
LAKHIMPUR BUILDING CIRCLE, NORTH LAKHIMPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
₹1.1 L
Yes
12 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
Amount
Earth work in evacuation by mechanical means (Hydraulic excavator) / manual means in foundation treanches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S (non Modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and stuttering - All work up to plinth level : 4.1.5 1:3:6 ( 1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non Modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1. Cement mortar 1:4 (1 Cement: 4 Coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 :- 1;2;4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2:- 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc.
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board B' ceiling etc. complete (frame work to be paid seperatately). 12.26.1:- 6 mm thick Cement fiber board as per IS: 14862
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasterners of required dia & length ( hold fast lugs or dash fasterner shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertyical frains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary Screws
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat Iron diagonals 20x5 mm size, with top and bottom rail of T- iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m 18.7.3 25 mm nominal dia Pipes
15 mm nominal dia Pipes
40 mm nominal dia Pipes
65 mm nominal dia Pipes
100 mm nominal dia Pipes
Providing and fixing wash basin with C. I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets… (a) White Vitreous China Wash basin size 550×400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestral for wash basin completely recessed at the back for the reception of pipies and fittings
Supplying of readymade iron removal verval including G.S.T
Labour charges for fitting and fixing of iron removal veral
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 :- 1:1.5:3 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
Steel reinorcemet for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar 10 mm Dia
12 mm Dia
8 mm Dia
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 :- 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five 5.2.2:- 1:1.5:3 (1 cement : 1.5 coarse sand ( zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1:- Foundation ,footings, bases of columns, etc for mass concrete
5.9.5:-Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.13:- Vertical and horizontal fins individually or forming box louvers band, facias and caves boards
5.9.3:- Suspended floors, roofs, landings, balconies and access platform
15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix: 13.8.2 1:4 (1 cement : 4 fine sand)
Supplying fitting and fixing of water supply motor pump set mono block type complete with all accessories C.C. foundations with M.S nuts & bolts including D.O. starter and making necessary complete etc. Complete
Wiring for light point/fan point/ exhaust fan point call bell point with 105 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate , suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2×4 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for laptop earthing as required.
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor ,. Single core cable in surface /recessed medium class PVC conduit as reqd. core cable in surface /recessed medium class PVC conduit as read. 2×1.5 sq. mm + 1 × 1.5 sq. mm earth wire
2×2.5 sq. mm + 1 × 2.5 sq. mm earth wire
2×4 sq. mm + 1 × 4 sq. mm earth wire
2×6 sq. mm + 1 ×6 sq. mm earth wire
4×10 sq. mm + 2 × 6 sq. mm earth wire
4×16 sq. mm + 2 × 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Bell puch
Supplying and fixing following two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch , connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch , connections etc. as required.
Supplying and fixing 3 pin , 5 A ceiling rose on the existing junction box/ wooden block including conections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC installed, copper conductor, single core cable
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicale panel, making connections, etc. as required. 200 A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel , making ,connections., etc. as required. 100 A, 16 KA, TPMCCB
100 A , 30 KA , FPMCCB
200 A, 36KA, FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar, earth bar , din bar, interconnections, powder painted including earthing etc. as required. ( But without MCB /RCCB/ isolator) 6 way, Double door
8 way Double door
Supplying and fixing following way surface/recess mlounting, vertical type, 415 V, TPN MCB fdistribution board of sleet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : vertical type MCB TPDB is normally used where 3 phase outlets are required) 4 way (4+12), Double door
Supplying fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Triple pole and neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole,15 volts,insolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 100 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc 40 A
Supplying and fixing TP sheet steel enclosure on surface/recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C"curve, TPMCB. in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc.as required
Earthing with copper earth plate 600 mm × 600 mm × 3 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection as required.
Supplying and Laying 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connections/ termination with G.I thimble etc. as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supply, Installation , Testing and Commissioning of 1200 mm sweep , BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor ,complete as required.
Supplying and fitting and fixing of LED 18/20 W T-5 luminaries complete with all accessories such as ballast, starter etc directly on wall /Ceiling with making necessary connection as required.
Supplying and fitting of 9/12 watt LED lamp in the existing batten holder / Angle holder/ bracket/ pendent holder etc as directed by the department.
Supplying inciuding instailation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical Outdoor type foor mounting compartmentalize panel board of size 1200 (w)x 1250 (H) + 400 (D) mm made of 16 SWG1.66m thick C.R sheet and 35 mm: x 35 mm x 5 mm size angle having nos.of leg at the bottom and C.R. sheet roofing on the top. The paneL board is to be erected in 1:3:6 PCC foundation including excavation of one no. 200 A4 pole MCCB or Switch Fuse as incomer and provision for 2 nos. DP or TPN out going as specified and directed by the deptt. Confirming to IP 65 protection. 1. 30 mm x 5 mm 4 strip copper bus-bar 0.5 M length each.
Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hoie on the wail of following sweeps with making necessary connection as approved by the Deptt... Domestic upto 300 mm sweep
Supplying with fitting and fixing of High performance LED Each Street light luminaries,80 watt, with Single Die Ceramic base high power LED light source, IP 66 protection, PDC housing & aesthetic finless design and toughened glass cover and Street light optics (Wipro Make) complete as required and as directed by the department
Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt.1.00 HP, Single Phase,230v, MINI MASTER PLUS I (Crompton Make).
Supply and laying of following size PVC / XLPE insulated and PVC sheathed 1.1 KV Grade solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated , armoured U. G. cable . U.G. Cable laid in ground / partially in air (as required for termination over ground including excavation of cable trench up to depth of 75 cm , refilling , protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. 6.00 Sq. mm . 2 Core armoured U.G. cable.
25.00 Sq. mm 4 Core armored U.G cable.
Mattress for Hostel Bed
Manuj Bhuyan
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .