| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹14.3 L
EMD Value
₹28,508
Closing Date
1 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, UWD, GGSIPU
SE, UWD, GGSIPU
Replacement and Upgradation of telephone cable network in GGSIPU Dwarka Campus
2020_GGSIP_193662_1
12/SE/UWD/Elect/2020-21
Open Tender
Electrical Works
Works
45 days
SE, UWD GGSIPU Sector 16C, Dwarka
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹28,508
3 Sept 2020
20 Aug 2020
1 Sept 2020
20 Aug 2020
1 Sept 2020
20 Aug 2020
90 days
Amount
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 160 mm dia (OD-160 mm & ID-135 mm nominal)
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix ( i/c equivalent design mix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 ( 1 Cement: 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size)
Making trench less under ground hole across the roads/cement concrete pathway at a depth of about 1 mtr. by means of manual augor and connecting pipes to suit the pipe/cable of size up to 180 mm dia. i/c making excavation on both side of road/pathway for making trenchless hole and refilling the same with excavated soil after laying pipe & cable through trenchless hole. watering. dressing complete as required as per instruction of Engineer-incharge. (Cost of laying of cable & pipe is not included in this item)
Supply of following pair, 0.5 mm size copper conductor, jelly filled PVC insulated and PVC sheathed telecommunication cable with G.I.Wire/strip armouring generally confirming to ITD specifications/WS-113 C & S/WS-114 armouring and outer sheath confirming to IS: 1554 (Part -I) as required. 200 pair armoured
Supply of following pair, 0.5 mm size copper conductor, jelly filled PVC insulated and PVC sheathed telecommunication cable with G.I.Wire/strip armouring generally confirming to ITD specifications/WS-113 C & S/WS-114 armouring and outer sheath confirming to IS: 1554 (Part -I) as required. 100 pair armoured
Supply of following pair, 0.5 mm size copper conductor, jelly filled PVC insulated and PVC sheathed telecommunication cable with G.I.Wire/strip armouring generally confirming to ITD specifications/WS-113 C & S/WS-114 armouring and outer sheath confirming to IS: 1554 (Part -I) as required. 50 pair armoured
Supplying and fixing of following sizes of telephone tag block including krone for termination of paired wires in 2 mm thick MS Box of suitable size designed to include the tag blocks with sufficient space and with hinged lockable metal cover duly painted as required and as per direction of engineer-in-charge 200 Pair
Supplying and fixing of following sizes of telephone tag block including krone for termination of paired wires in 2 mm thick MS Box of suitable size designed to include the tag blocks with sufficient space and with hinged lockable metal cover duly painted as required and as per direction of engineer-in-charge 100 Pair
Supplying and fixing of following sizes of telephone tag block including krone for termination of paired wires in 2 mm thick MS Box of suitable size designed to include the tag blocks with sufficient space and with hinged lockable metal cover duly painted as required and as per direction of engineer-in-charge 50 Pair
Supplying and end termination/punching duly crimping with brass comprasion gland and ferruls for following pairs telephone cables etc as required and as per direction of engineer-in-charge 200 pair
Supplying and end termination/punching duly crimping with brass comprasion gland and ferruls for following pairs telephone cables etc as required and as per direction of engineer-in-charge 100 pair
Supplying and end termination/punching duly crimping with brass comprasion gland and ferruls for following pairs telephone cables etc as required and as per direction of engineer-in-charge 50 pair
AKOUSTIK COMMUNICATIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .