Maintenance of Electrical installations in Residential and Non-residential buildings.
2024_GSO_837260_1
GSO/CTC/ESD/129/2024
Open Tender
Electrical Works
Item Rate
365 days
DAE Township, Anupuram
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹98,000
20 May 2025
29 Nov 2024
30 Dec 2024
29 Nov 2024
28 Dec 2024
17 Dec 2024
30 Nov 2024 - 13 Dec 2024
Amount
Supply, replacement and testing of the following MCB / RCCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
6-32 Amps SP MCB (Type-C)
6-32 Amps DP MCB (TYPE-C)
40-63Amps, FP MCB (TYPE-C)
125 Amps FP MCB (Type-C)
RCCB DP 25A sensitivity 30mA, TYPE Hpi
RCCB DP 40A sensitivity 30mA, TYPE Hpi
RCCB FP 40A sensitivity 30mA, TYPE AC
RCCB FP 63A, 300 mA sensitivity Type AC
Supply, replacement and testing of following Switches /Bell push / Sockets / Plug top etc. as per the detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.5).
1 No 10A One Way Switch on modular plate and termination of wires to the switches.
1 No 10A Two Way Switch on modular plate and termination of wires to the switches
1 No 10A Bell Push Switch on modular plate and termination of wires to the switches
1 No 16A One Way Switch on modular plate and termination of wires to the switches.
1 No 16A Two Way Switch on modular plate and termination of wires to the switches.
1 No 6A 3 Pin Shuttered Type Socket heavy duty on modular plate and termination of wires to the switches.
1 No 6/16A 3 Pin combined shuttered type Socket heavy duty on modular plate and termination of wires to the switches
1 No 20 Amp Motor starter Switch on modular plate and termination of wires to the switches.
1 No 16A 3Pin heavy duty plug top with indicator and termination of wires to the switches
1 Modular dummy plate
One/Two module Modular front cover plate
3 Module Modular front cover plate
4 Module Modular front cover plate
6 Module Modular front cover plate
8 Module Modular front cover plate
12 Module Modular front cover plate
1No Geyser Indicator and termination of wires to the switches.
1No 20 Amps SP C MINI MCB suitable in modular plate and termination of wires to the MCB.
1No 30 Amps Electronic Key Tag + Key card in modular plate and termination of wires to the key control tag.
Supply, replacement and testing of following Lamp holders suitable for various type of luminaries as per the detailed specification and as directed by Engineer-in-charge
Fancy Type Angle / Batten Holder
Supply, replacement and testing of the following electrical accessories / control gears as per the detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.12).
Bi-Pin Twist Lock Lamp Holder suitable for 28/36/40 Watts Fluorescent Lamps.
Universal Starter for 20/40 Watts Fluorescent Lamp as per Cat. No.S-10.
Electronic ballast Suitable for 1 X 36 Watts Fluorescent fitting.
Electronic ballast Suitable for 1 X 18 Watts Fluorescent fitting.
Supply, replacement and testing of 18 W Ultra violet lamp (ACTINIC) suitable for flying insect controller equipment and working voltage is 240V AC as per the detailed specification and as directed by Engineer-in-charge.
Supply and replacement of following Calling bells as per the detailed specification and as directed by Engineer-in-charge.
Calling bell - Ding Dong type
calling bel - Musical chime type
Supply, replacement and testing of 9 inches Gong Bell as per the detailed specification and as directed by Engineer-in-charge.
Supply, replacement and testing of 63 Amps, 3 Pole MCCB as per the detailed specification and as directed by Engineer-in-charge.
Supply and Embedment of 50mm Deep, Square/Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification. (Refer Sec VI, Clause No.15.12).
ONE/TWO Module
THREE Module
FOUR Module
SIX Module
Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6).
Surface Mounting Plastic Boxes 1/2 Module
Surface Mounting Plastic Boxes 3 Module
Surface Mounting Plastic Boxes 4 Module
Surface Mounting Plastic Boxes 6 Module
Surface Mounting Plastic Boxes 12 Module
Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
Wiring with 1 Run of 1.5 Sq.mm Copper wire
Wiring with 1 Run of 2.5 Sq.mm Copper wire
Wiring with 1 Run of 4 Sq.mm Copper wire
Wiring with 1 Run of 6 Sq.mm Copper wire
Supply, transportation, replacement, testing and commissioning of the following LED Luminaires of suitable wattage as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.16.0).
6W (Max), 700 lm output, 6500K, IP 66 Protection LED Bulkhead with Aluminium die cast housing and polycarbonate diffused cover suitable for surface mounting.
12W (Max), 1200 lm output, 6500 K, 600 mm long, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting.
18W (Max), 2000 Im output, 6500K, 150mm dia size, recess mounting LED Luminaires with aluminium dia cast housing.
15W (Max), 1600 lumen output, 6500K, square /round type, LED Luminaires with polycarbonate material housing, suitable for surface mounting.
36W (Max), 3600 lm output, 6500 K, 600mm x 600mm Recessed mounting type LED Light with CRCA housing suitable for 2 x 2 grid false ceiling.
31W (Max), 3200 lm output, 6500 K, 600mm x 600mm surface mounting type LED Light with CRCA housingsurface mounting.
29W (Max), 4000 lm output, 6500 K, 1200 mm long, LED batten with CRCA housing, suitable for Ceiling, Wall and Downrod mounting.
17W (Max), 2000 lm output, 6500 K, 1200 mm long, LED Battern with CRCA housing, suitable for ceiling, wall and downrod mounting.
20W (Max), 2000 lm output, 6500 K, 1200 mm long, LED Battern with Polycarbonate housing, suitable for ceiling and wall mounting.
Replacement of fluorescent lamps with LED Lamps including supply of 20W, 4 feet, 25mm dia, LED tube with built-in ballast (CG) or Equivalent and required rewiring inside the luminaires as per the detailed specification enclosed. (Refer Sec VI (MNC), Clause No.12.0).
Tracing and rectification of defects in the Electrical installation in residential and public buildings as per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.4.0).
Replacement, testing and commissioning of electrical components such as switch /socket / Ballast / Holder / Modular plates and Lamps etc, as per the detailed specification and as directed by Engineer-in-charge. Note:- Required Electrical component will be issued at free of cost cited above as applicable by the Department.
Preventive Maintenance of Bus bar trunking systems as per the detailed specification and as directed by Engineer-in-charge.
Preventive Maintenance of G+2 Stair case / Tower building Energy Meter Distribution Board (EMDB) as per the detailed specification and as directed by Engineer-in-charge.
Preventive Maintenance of 3 Phase Energy Meter Distribution Board (EMDB) in Residential building (Type V E) as per the detailed specification and as directed by Engineer-in-charge.
Preventive Maintenance of 8/12 Way 16/32/63 Amps MCB Power and Lighting Distribution Boards located in various public buildings as per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.17.3).
Carrying out healthiness check of RCCB, MCB in TPN/SPN 12/8/6 way DB including checking of earth continuity of the distribution system at following type of residential quarters as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.17.3).
Type B / C / SA type Residential Quarters
Type D / E Residential Quarters
Carrying out Full House Maintenance in various types of Residential buildings as per the detailed specification and as directed by Engineer-in-charge.
Full House Maintenance of Type B / C / SA type Residential Quarters (Entire House)
Full House Maintenance of Type D / E Residential Quarters (Entire House)
Cleaning of Stair Case/Tower Panel (EMDB) as per the specification in the scope of work and as directed by the Engineer-in-charge.
Cleaning of 3 Phase EMDB in Residential building (Type VE) as per the specification in the scope of work and as directed by the Engineer-in-charge.
Cleaning of ceiling mounted, fluorescent fittings, CFL and LED luminaries in Residential and Public Buildings like Office rooms, class rooms, Lobbys, Rest rooms etc. as per detailed specification and as directed by Engineer-in-charge.
Identification and rectification of shunt or series fault in lighting or power circuit wiring in building as per scope of work (Refer Sec VI (MNC), Clause No.4).
Minor fault
Major fault
Supply and Installation of 25 X 12 mm size of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29)
Supply, installation, testing and commissioning of 4 module plate with 20 A starter, 16 A socket heavy duty and 16 A plug top with indicator on already embedded metal box as per detailed specification and as directed by Engineer-in-charge.
Wiring for AC point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits or Trunking as per the detailed scope of work, including supply of 2 Runs of 4Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
Painting of 415V Switchboards, Cubicle switch boards having number of vertical sections up to 3, with One coat of synthetic enamel Paint including supply of paints and required consumables as per detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.3).
Supply and Installation of laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification.
Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)
Supply and Installation of 6 levers long shackle brass lock with master key as per detailed specification and as directed by Engineer-in-charge.
Supply and replacement of following heater coils / thermostat as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.13).
230V, 1/2 kW, Single phase Heater coil suitable for BAIN MARIE/Geyser.
230V, 3kW, Single phase, Heater coil suitable for DOSA TAWA / IDLI BOILER / Instant water heater etc.
240 Volts, 16 Amps, 50 Hz. Thermostat with adjustable Temperature Range 20 - 80 degree Centigrade.
Maintenance and Servicing of Rice/Idly boiler, Bain maries and Hot Plates, including contacts installed in kitchen as per the detailed scope of work and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.13).
Supply and fixing of DO's & DONT's display board at side wall of lift car. The board made up of 2mm thick, A3 (11.7'' X 16.5'') size Acrylic sheet with colour print and affixing white background sheet including 6 Nos. of stainless steel screws for fixing as directed by Engineer-in-Charge.
Bidder Name
SAS ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .