Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹29.8 L+₹5.5 L (22.6%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹31.5 L+₹7.2 L (29.5%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹31.6 L+₹7.3 L (29.9%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected | |
| 5 | L5₹31.7 L+₹7.4 L (30.3%)Rejected-AOC | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Belgaum
Garrison Engineer, Belgaum Laxmi Tek Belgaum
WELCOME MAINTENANCE TO OFFICERS MD ACCN AND EXTERNAL FINISHES TO CERTAIN MD ACCN UNDER GE BELGAUM
2021_MES_470322_1
GE/BEL/ OF 2021-2022
Open Tender
Civil Works
Item Rate
Garrison Engineer, Belgaum
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Belgaum
₹80,000
Yes
30 Sept 2021
25 Aug 2021
17 Sept 2021
25 Aug 2021
15 Sept 2021
25 Aug 2021
60 days
Amount
Taking down cement or cement lime plaster on brick or stone walls, ceilings, etc. including raking out joints, hacking for key scrubbing down with water etc.
M&L for floor door stopper of aluminium body and tongue, anodised, with 140mm long cover plate and hard drawn steel spring, fixed in floor all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm fixed in panel of joinery with stainless steel wire staples all as specified and directed.
S&F in repairs Mild steel powder coated curtain rods with rounded fancy ends, 25mm dia including provision of suitable MS CP brackets and fixing the same with holding screws with necessary drilling and plugging all as specified and as directed. Make: MARVEL or equivalent
M&L for coloured vitrified tiles, square or rectangular, light shade, 9 to 10mm thick, area of each tile not exc 0.36 Sqm, as in floors/ skirtings, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of existing unserviceable tiling alongwith cement mortar bedding (but not backing) and removing rubbish off the premises all as specified and directed.
M&L for coloured glazed ceramic tiles 300mm x 450mm x 7 to 8mm thick on vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces including 10mm thick backing coat in CM 1:4 including dismantling of existing unserviceable tiling alongwith cement mortar bedding and backing and removing rubbish off the premises all as specified and directed.
M&L for coloured non skid ceramic tiles, 6 to 7mm thick area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling existing tiles of any desciption including cement mortar bedding (but not backing) removing, rubbish off the premises all as specified and directed.
M&L for 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finishing the surfaces even and smooth without using extra cement all as directed.
M&L for one coat of white wash on old decorated surfaces of walls, pillasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed.
M&L for one coat of white wash on old decorated surfaces of ceilings including necessary preparation of surfaces all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour, on old distempered surfaces of walls, pillasters, cornices, etc., including necessary preparation of surfaces by washing, rubbing down and stopping all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour over a coat of primer over 1mm thick layer of wall care putty on walls, pilasters, cornices, etc., including complete removal of existing treatment and necessary preparation of surfaces all as specified and as directed.
M&L for one coat of oil bound distemper (Acrylic distemper washable), any colour, on old distempered surfaces of walls, pillasters, cornices, etc., including necessary preparation of surfaces by washing, rubbing down and stopping all as specified and as directed.
M&L for one coat of oil bound distemper (Acrylic distemper washable), any colour, on old distempered ceilings including necessary preparation of surfaces by washing, rubbing down and stopping all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable), any colour, over a preparatory coat of chalk whiting on newly plastered surfaces of walls, pilasters, cornices, etc., including necessary preparation of surfaces all as specified and directed.
M&L for one coat of cement based paint on old cement painted walls, pillasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed.
M&L for one coat of synthetic enamel paint on old painted wooden surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
M&L for one coat of synthetic enamel paint on old painted steel surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
M&L for re-writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high with and including synthetic enamel paint all as specified and as directed.
S&F in repairs bib taps brass chromium plated with crutch or butterfly handle screwed for 15mm bore GI pipe all as specified and directed.
S&F in repairs 15 mm bore 2 way Bib tap, long body, brass chromium plated, fancy type, with crutch or butter-fly handle, screwed down, screwed for iron pipe or for brass ferrule etc all as specified and directed. Make: Cat No. FUS 29041 of JAQUAR or equivalent model in JOHNSON/ CERA
S&F in repairs health faucet, brass chromium plated with 1m long flexible PVC tube and wall hook all as specified and as directed. Make: Cat No. 563 of JAQUAR or equivalent model in JOHNSON/ CERA
S&F in repairs 3 way mixer tap for mixing hot and cold water, fancy type, brass chromium plated screwed down for 15mm bore GI pipe all as specified and directed. Make: JAQUAR/ JOHNSON/ CERA
S&F in repairs PVC connection 15mm size with PTMT nuts, 450mm long all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including 'P' or 'S' trap, plastic water closet seat, any colour as approved by GE, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, fixing bolts etc, (excluding flushing cistern and flush pipe) all as specified and as directed.
S&F in repairs plastic water closet seat for EWC, closed pattern any colour, with flat bottom and cover and mild steel chromium plated or aluminium hinging device all as specified and directed.
S&F in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float, handle complete all as specified and directed.
S&F in repairs Tubular Towel rail, 60 cm long, brass chromium plated, fixed with suitable CP screws etc. complete all as specified and directed. Make: Cat No. 1181 of JAQUAR or equivalent in ARK/ JOHNSON/ ESSESS
S&F in repairs corner glass shelf, 5mm thick, 9" wide, fixed with suitable MS CP brackets etc. complete all as specified and directed. Make: JAQUAR or equivalent in ARK/ JOHNSON/ ESSESS
S&F in repairs 750mm long PVC flexible pipe (waste pipe), suitable for 32 mm bore waste coupling of sink/ wash hand basin all as specified and directed. Make: Kohinoor or equivalent approved make.
S&F PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm dia outlet all as specified and directed.
M & L for elastomeric membrane treament with the folowing specifications all as specified and directed (for non accessible roof/chajjas)
Provide a layer of 5mm thick (1:3) with WPC over a coat of 10mm thick plaster in CM 1:3
Two coats of acrylic polymer based flexible cementations elastomeric ( Dr. Fixit New coat/ Conipur M800 of BASF/ Brush bond of Fosroc Brand/ equivalent of Sika/ Cico/ MC- bauchemie/ STP Ltd/Tiki tar) Membrane of about 1-1.5mm dry film thickness(dft) over a coat of primer as per manufacturer's instruction over roof slab and taken up to 300mm high in wall etc as per manufacturer's specifications.
Polyurethene based single component water proofing liquid water proofing membrane treatment, as per manufacturer's instruction, the make/ brand shall be of STP Ltd, FOSROC, BASF, Pidilite, Sika tiki tar and equivalent.
NOTE: Water proofing chemmicals shall be procured from approved manufacturer with prior written approval of GE. Full quatity of fresh chemicals required for incorporating in the work shall be brought to site with sealed containers. Water proffing treatment shall be carried carried out through authorised applicator of the manufacturer and the cantractor shall preodure necessary certificate of authentication to the Engineer-in-charge before commence of the work.
Supply and lay 16mm dia CPVC pipes SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed including taking up or down old damaged pipe.
Supply and lay 20mm dia CPVC pipes SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed including taking up or down old damaged pipe.
Supply and lay 25mm dia CPVC pipes SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed including taking up or down old damaged pipe.
M&L for Point wiring complete with 1.5 Sq mm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded cables drawn through and including ISI marked PVC casing capping of suitable size and all necessary fittings and provision of one run of PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including 2nd class HW board fixed on wall with sunmica top for mounting switches/ sockets etc. for one light point controlled by one switch 1 way including taking down existing unserviceable point wiring of any description and making good disturbed surfaces complete all as specified and directed. all as specified and directed.
All as described in item No. 38 but for one fan point controlled by one switch and regulator.
All as described in item No. 38 but for one call bell point controlled by one bell push
All as described in item No. 38 but for one 05 Amps socket outlet on independent board.
All as described in item No. 38 but for one 05 Amps socket outlet on the same board with other switches.
All as described in item No. 38 but for one light point controlled by two, two switch.
All as described in item No. 38 but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable and with one run of single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable of size 2.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15 Amps power socket point on independent board all as specified and directed.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4.0 sqmm drawn through and including PVC casing and capping of suitable size with all necessary fittings and provision of one run of 4.0 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, including taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces complete all as specified and directed. Note: Two runs of 4.0 sqmm cable, one run of 4.0 sqmm earth conductor cable and one run of PVC conduit accessories in concealed wiring shall be measured and paid together as one unit length.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm drawn through and including PVC casing and capping of suitable size with all necessary fittings and provision of one run of 6 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, including taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces complete all as specified and directed. Note: Two runs of 6 sqmm cable, one run of 6 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
M&L for sub main wiring with 4 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 10sqmm drawn through and including PVC casing and capping of suitable size with all necessary fittings and provision of two runs of 10 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, including taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces complete all as specified and directed. Note: Four runs of 10 sqmm cable, two run of 10 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
S&F in repairs switch, piano type, 5 Amps, flush button, 230 volts, AC, one way all as specified and directed.
S&F in repairs switch piano flush type 15 Amps 230 volts all as specified and directed.
S&F in repairs switch piano flush type 5 Amps, 230 Volts, AC, two way all as specified and directed.
S&F in repairs bell push, flush type, 5 Amps, 230 volts, AC, one way all as specified and directed.
S&F in repairs socket outlet 5 Amps 3 and 5 pin flush type multipurpose all as specified and directed.
S&F in repairs socket outlet 15 Amps 3 and 5 pin 5 and 15 Amps flush type multipurpose all as specified and directed.
S&F in repairs ceiling rose 3 terminal suitable for 230 volts AC supply all as specified and directed.
S&F in repairs fan regulator electronic step type suitable for 1200/1400 mm sweep ceiling fan all as specified and directed.
S&F in repairs call bell, ding dong, 230 volts AC supply all as specified and directed.
S&F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover of size 100mmx100mm and 50mm deep complete all as specified and directed.
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded cables drawn through and including PVC conduit pipes/ PVC casing and caping with all accessories and provision of one run of PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including provision of suitable GI modular box flush mounted flush with wall alongwith modular frame and white cover plate for mounting modular switches/ sockets etc. for one light point controlled by one switch 1 way complete all as specified and directed. all as specified and directed.
All as described in item No. 58 but for one fan point controlled by one switch and regulator.
All as described in item No. 58 but for one call bell point controlled by one bell push
All as described in item No. 58 but for one 05 Amps socket outlet on independent board.
All as described in item No. 58 but for one 05 Amps socket outlet on the same board with other switches.
All as described in item No. 58 but for one light point controlled by two, two switch.
All as described in item No. 58 but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable and with one run of single core PVC insulated FRLS unsheathed 1100 volt grade multi-stranded copper conductor cable of size 1.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15 Amps power socket point on independent board all as specified and directed. Note: Two runs of 2.50 sqmm cable, one run of 2.50 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
S&F in repairs modular switch, 1 module, 1 way, 6 Amps, 230 volts, AC, all as specified and directed.
S&F in repairs modular bell push, 1 module, 1 way, 6 Amps, 230 volts, AC, all as specified and directed.
S&F in repairs modular switch, 1 module, 1 way, 16 Amps 230 volts, AC, all as specified and directed.
S&F in repairs socket outlet, 2 module, 6 Amps 2 cum 3 pin multipurpose all as specified and directed.
S&F in repairs socket outlet, 2 module, 2 pin 6A/ 3 pin 16 Amps, multipurpose all as specified and directed.
S&F in repairs fan regulator electronic modular step type suitable for 1200/1400 mm sweep ceiling fan all as specified and directed.
S&F in repairs modular switch, 1 module, 2 way, 6 Amps, 230 volts, AC, all as specified and directed.
S&F in repairs modular cover plate with frame, white, 4 module all as specified and as directed.
S&F in repairs modular cover plate with frame, white, 6 module all as specified and as directed.
S&F in repairs modular cover plate with frame, white, 8 module all as specified and as directed.
S&F in repairs modular metal flush box with 3 module 230 Volts AC all as specified and as directed.
S&F in repairs modular metal flush box with 4 module 230 Volts AC all as specified and as directed.
S&F in repairs modular metal flush box with 6 module 230 Volts AC all as specified and as directed.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4.0 sqmm drawn through and including rigid PVC CONDUIT and capping of suitable size with all necessary fittings and provision of one run of 4.0 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 4.0 sqmm cable, one run of 4.0 sqmm earth conductor cable and one run of PVC CONDUIT and caping shall be measured and paid together as one unit length.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm drawn through and including PVC CONDUIT and capping of suitable size with all necessary fittings and provision of one run of 6 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 6 sqmm cable, one run of 6.0 sqmm earth conductor cable and one run of PVC CONDUIT and caping shall be measured and paid together as one unit length.
S&F in repairs MCB DB VTPN 4 Way with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs MCB DB TPN 4 Way with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs MCB DB SPN 12 Way with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs MCB DB SPN 8 Way with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs MCB DB SPN 4 Way with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F in repairs MCCB 4 Pole 100 Amps, 16 KA current rating confirming to IEC-609472 & IS-139473 to be fixed in distribution boardcomlete all as specified and directed.
S&F in repairs MCB TPN 40A 10KA 'C' series 50Hz 415 Volts AC supply all as specified and as directed.
S&F in repairs MCB DP 40-63A 10KA 'C' series 50Hz 240 Volts AC supply all as specified and as directed.
S&F MCB SP 5-32A 10KA 'C' series 50Hz 240 Volts AC supply all as specified and as directed.
S&F in repairs lamp holder, insulate body with back plate for batten fitting including LED lamp of 9 watt- 01 No complete all as specified and as directed.
S&F in repairs energy saving surface mounted, decorative oval bulk head edge-lit LED luminaire 10W, comprising of high brightness LEDs. comprising of high brightness LEDs complete with all accessories internally pre wired complete including provision of 10 Watts high brightness LEDs 6000K, suitable size wooden board with sunmica top and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block complete all as specified and directed. Make: Havells ENDURA RUGBY NEO N- IP65 or equivalent in CG/ Philips/ Wipro
S&F in repairs round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repairs round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair LED lights fitting 1 x 20W, 220V, AC decorative box type with driver, holer inclding LED tube liht connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S & F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver, holder and LED lamp including connecting up with three core flexible copper conductor calbe of suitable size complete all as specified and directed.
S & F in repair LED light fitting mirror type with high out put diffuser 1 feet, 5 watt 220 V AC decorative type with driver, holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexibble copper conductor cases of subtable size complete.
S&F in repair LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminum hosting and heat resistant complee with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple okptics complete with IP 65/66 protetion complete
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground vertically (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below normal ground level connected to GI wire 4mm dia (7.5m long) by means of GI bolts nuts washers and GI wire protected by 15mm dia light grade GI pipe (7.5m long) and watering arrangements with 20mm dia GI pipe medium grade and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule Part I including necessary excavation and earth work in any type of soil, charcoal, dust salt, PCC 1:2:4 type B1 in chamber, 40mm thick RCC 1:2:4 type B1 in cover slab with 8mm dia TMT bars at 100mm C/C both ways and with 8mm dia MS hook complete and testing all as specified and directed.
M/S MAHADEV M PATIL
SAMARTH ASSOCIATES
RAJENDRA KRISHNA SARAF
M/s. KIRAN M CHOUGULE
Vinod Enterprises
N K CONSTRUCTION
ASHOK M RAJGOLKAR
SAGAR ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .