Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance VILLAGE MANDRI P O CHALAHAL SUB TEHSIL DHAMI DISTT SHIMLA SHIMLA HIMACHAL PRADESH | Admitted-Finance |
| 5 | Admitted-Finance 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | Admitted-Finance |
Tender Value
₹48.8 L
EMD Value
₹80,630
Closing Date
15 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Director of Agriculture Chambaghat Solan
Deputy Director of Agriculture Chambaghat Solan
Construction of SMS Office cum residential accommodation Building at Village Kunihar, Tehsil Arki, Distt Solan, Himachal Pradesh
2021_DoA_44927_1
Construction of SMS residential accommodation
Open Tender
Civil Works
Item Rate
180 days
As per Tender Document
As per Tender Document
3 documents required · 3 mandatory
₹500
Deputy Director of Agriculture Chambaghat Solan
₹80,630
18 Mar 2021
1 Mar 2021
16 Mar 2021
1 Mar 2021
15 Mar 2021
2 Mar 2021
2 Mar 2021 - 14 Mar 2021
180 days
Amount
Excavation in foundations, trenches etc., in earth work, lift up to 1.50 Metres stacking the excavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres. P&J (50:50)%.
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in:
Foundation and plinth :-
Providing and laying cement concrete 1:1.5:3 (1cement :1.5 sand :3 graded stone aggregate 20mm. nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:
Foundation footings bases of columns and the like and mass concrete.
Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers up to floor two level.
Independent piers columns and pillars at Ground
Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers up to floor two level.
Providing and laying cement concrete work 1:2:4 (1 Cement:2 Sand:4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and cantilever up to floor two level Pantry in Ground Floor
Providing and laying cement concrete 1:1.5:3 (1cement :1.5 sand :3 graded stone aggregate 20mm. nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in: Stair cases (except spiral stair case) excluding landing but including preparing of the surface and finishing of nosing up to floor two level.
Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete up to floor two level : Tor Steel: i.e. 100kg/ CUM :- For Footing , Column & beams upto roof,80 kg/ CUM :- For Roof Slab & Slabs in pantry,100 kg/ CUM :- For Staircase Total quantity of steel to be used
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu- reinforced concrete & plain concrete work in:
Foundation, footings basis of columns etc. and mass concrete. Upto G.L.
Columns, pillars, posts and struts Square, rectangular or polygonal in plan (Ground & First Floor)
Beams, cantilever, girders and lintels. Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like.: Floors etc.upto 200mm in thickness.
Stair cases with sloping or stepped soffits excluding landing(4 flights upto third floor level) (DRAWING ATTACHED)
Edges of slabs and breaks in floors and walls: Under 20 cm. wide.:- For Slab @
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 Cement : 3 Sand : 6 Graded stone aggregated 20mm nominal size)
Filling in plinth with stone with approved quality under floors including watering, ramming, consolidating and dressing complete = Plinth Area- Area of the Beams =219.20-36.65=182.55
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work for floor at plinth level. [over 0.15m stone bed] = Plinth Area- Area of the Beams =219.20-36.65= 182.55
Brick work in :Super-structure above plinth level upto floor two level (First Class Bricks)
Half brick masonry in common burnt clay building bricks in : Cement Mortar 1:4 (1 cement : 4 sand) First Class Bricks
15mm Cement plaster in single coat on the rough side of brick / concrete / stone walls for interior plastering up to floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth, and as per specification, drawing and as directed by Engineer-in-Charge.in cement Mortar(1:4)
6mm Cement plaster to ceiling In Cement Mortar 1:4(1 Cement:4 Sand) : Ceiling
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
Applying priming coat on new concrete/masonry/asbestos cement/ plastered surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required with :- Ready mixed primer
Painting two coats (excluding priming coat on new concrete masonry/ plaster surfaces with ready mixed paint brushing for use on floors to give an even shade including cleaning the surface of all dirt, dust and other foreign matter and sand papering as required with:- Paint other than white
Providing and fixing 10mm thick anti skid water proof stain and impact resistant heavy duty vitrified tiles Nitco or equivalent 600x600mmx10mm manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete.
Kota stone slab 25 mm thick in risers of steps, skirting dado and pillars laid on 12 mm (average)thick cement mortar 1:3 (1 cement:3 sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete.
Providing and laying Duro stone vitrified tiles (300x 300mmx 8mm) in grey/coloured or of approved shade in flooring, treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1 cement : 3 sand) laid over and jointed with neat cement slurry finished with flush pointing in white cement mixed with pigment of required shade to match the shade of tiles complete.
Providing and laying Duro stone vitrified tiles (300x 300mmx 8mm) in grey/coloured of required shade in skirting risers of steps and dados on 12mm thick cement mortar 1:3 (1 cement : 3 sand) laid over and jointed with neat cement slurry finished with flush pointing in white cement mixed with pigment of required shade to match the shade of tiles complete.
White glazed tiles 6 mm thick in skirting risers of steps and dado 12 mm thick cement mortar 1:3 (1 cement :3 sand) and jointed with cement slurry, cleaning the surface complete, and as per specification, drawing and as directed by Engineer-in-Charge.
Providing and laying granite stone in flooring 20mm(average) thickness base of cement mortar 1:3(1cement:3 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of granite stone i/c rubbing and polishing complete. 20mm. thick
Providing and fixing moulded hand rail of M.S. hollow pipe 50mm dia welded in straight length over M.S. flat at top of vertical balusters including one coat of red oxide priming coat complete (M.S. flat & balusters of railings shall be measured & paid separately.
Providing and fixing M.S. grills of required patterns in Staircase railing, over Parapet wall upto 0.50m height @ 15.00 kg/sqm
Supplying and fixing rolling shutters of approved make made of80 mm X 1.25mm M.S laths interlocked together through their entire length and joined together at the end by end locks mounted on specially designed pipe shaft, with brackets side guides and arrangements for inside and outside locking with push pull operation complete but excluding the cost of the top cover and spring
Shutters having width below 3.5metres.
Providing and fixing ball bearing
Providing and fixing on wall face PVC (D-Plast) rain water pipes of working pressure not less than 4.5 kg/SQM including filling the joints with approved adhesive complete: 100mm dia pipes :- Height from the roof to GL =(4*3.75)+(2*7.05)
Constructing Course rubble hammer dressed 'U' shape open surface drain with side wall. 15x22 cm in cement mortar 1:6 (1 Cement : 6 Sand) and inside plastering with cement plaster 1:3 (1 Cement:3 Sand) including earth work and laying 10 cm cement concrete in 1:5:10 (1 Cement : 5 Sand : 10 graded stone aggregate) of 40 mm nominal size) and 7.5 cm cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Graded stone aggregate of 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.(Around the building at 1.20 offset)
Providing and fixing anodized aluminum work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodized transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically where ever required including cleat angle, aluminum, snap beading for glazing/ paneling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge. For doors windows and ventilators and glazed partitions frames
Aluminum Rectangular Tube 100x 50x 4mm= 3.067kg/m, =3.067*298.60 =915.8062kg
For shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provisions for fixing of fittings DOOR Aluminium Rectangular Tube 50X25X1.50MM = 0.583/m, =0.583*505.11
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer- In charge (cost of aluminium snap beading shall be paid in basic item., Note: Providing and fixing "wire mesh” in Alumiium door & windows shutters will be paid separately)
Glazing with glass panes of 4mm thickness (weight not less than 10.00 kg/sqm.
Providing and fixing aluminium handles anodized transparent or dyed to required color & shade with necessary screws etc. complete.
125 mm= 2*no of doors
100mm=2*no of shutters
Providing and fixing anodized aluminium sliding door bolt anodized colour and shade with bolts and nuts screws etc. complete.
300x16mm (In all Doors)
Providing and fixing aluminium tower bolts (berrel type) anodized trans parent or dyed to required shade and colour with screws etc. complete.
200x10mm (For all doors ) 2 nos. each door
150x10mm (For all windows & wire gauge shutters) 2 nos. each shutter
Providing and fixing bright finished hard drawn hooks and eyes.
200 mm (For all windows & wire gauge shutters)
Providing and fixing 100mm bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete @ 14 Nos.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture (conforming to IS 6315) for aluminium door including cost of cutting floor as required embedding in floors and cover plates etc. complete as per the direction of Engineer-In-Charge I/c making good the floors
20mm thick plain cement mortar bands in cement mortar 1:4 (1 cement :4 sand) above 300mm in width.
(c) Raised Band.
EXCAVATION FOR FOUNDATIONS OF RETAINING WALLS Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Metres stacking the excavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres.(P&J) 50 : 50
Providing & laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40 mm nominal size) excluding the cost of centering & shuttering in Foundation & plinth.
Prov. form work with steel plates 3.15 mm thick welded with angle iron in frame 30 x 30 x 5mm,so as to give a fair finish i/c centering shuttering, strutting & propping etc. with wooden battens & ballies, ht. of propping & centering below supporting floor to ceiling not exceeding 4.00 mts. & removal of the same for in situ-reinforced concrete& plain concrete work :-
Foundation, footings basis of columns etc. and mass concrete. Up to G.L.
Providing and laying cement concrete 1:5:10 ( 1 cement: 5 sand: 10 graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of from work in retaining walls/Breast walls, the size of plums shall usually be 150mm.To 300mm. as per H.P.P.W.D. Specification)
Brick work in :Super-structure above plinth level upto floor two level (First Class Bricks)
Providing and fixing M.S. grills of required patterns over Parapet BRICK wall upto 0.30m height @ 25 kg/sqm and 35kg/sqm for the gates
15mm Cement plaster in single coat on the rough side of brick / concrete / stone walls for interior plastering up to floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth, and as per specification, drawing and as directed by Engineer-in-Charge.
Providing and laying up to first floor two level reinforced cement concrete 1:2:4 (1 cement : 2 Sand : 4 graded stone aggregate 20mm nominal size) to give a smooth and even surface including centering and shuttering etc. but excluding cost of reinforcement in
String courses, copings bed plates anchor blocks, plain window sills and the like : COPING OVER BOUNDARY WALL
EXCAVATION FOR FOUNDATIONS, DRAINS, CHANNELS, PIPES & CABLES Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Metres stacking the excavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres. (P&J) 50: 50. (i) Excavation of septic tank. (2.96+0.1+.1)
(ii) excavation of soak pit (3.14*0.88*0.88)
(iii) excavation of pipes 100 mm dia. Upto 3 m
Providing and laying cement concrete 1:3:6 (1 cement:3 sand:6 graded stone aggregate 40mm nominal size) excluding cost of centering and shuttering in: Foundations and plinth:
Sloping floor (triangular portion x length) 1 in 20 (Height = 0.05 * 2.5)
Brick work using common burnt clay building bricks in foundation and plinth in : Cement Mortar 1:5 (1 Cement : 5 Sand) Second Class Bricks
Brick work without mortar in soak pit
Brick aggregate filling in soak pit behind 230 mm thick brickwork. (Second Class Bricks)
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. (Course Sand filling in outermost layer of soak pit)
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu- reinforced concrete & plain concrete work in: Flat surfaces such as soffits of suspended floors, roofs, landings and the like Floors etc. up to 200mm. in thickness
Providing and laying cement concrete 1:1.5:3 (1cement :1.5 sand :3 graded stone aggregate 20mm. nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in: Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers upto floor two level.- for slab
Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level Tor Steel
15mm cement plaster in single coat on fair side of brick/concrete/stone walls for interior plastering up to floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (i) Cement mortar (1:3) (1 cement: 3 sand).
Supplying cast iron cover without frame for manholes- (i) For frame of internal dimension 455mmx610mm rectangular C.I cover (light duty single seal pattern -1) the weight of cover to be not less than 23 kg.
Sanitary accessories like vent pipes, connections, iron steps etc.(details provided in drawing) L/S Extra
Providing and fixing stainless steel kitchen sink of approved standard ISI make with drain board and C.P. waste with C.I. or M.S. Brackets painted white including cutting holes and making good the same but excluding fitting. I) 610 x 510 mm with bowl depth 200 mm. With Tray.
Providing and fixing vitreous China wash down, water closet (European type. W.C. pan) with integral ‘P’ or ‘S’ trap including jointing the trap with soil pipe in cement mortar 1:1(1 cement : 1 sand) (Seat and over to be measured and paid for separately (ii) Angle Indian Universal closet Each
Providing and fixing Vitreous China wash basin with single hole for pillar tap with C.I or M.S Brackets painted white i/c. Cutting holes & making good the same but excluding fittings:- Complete. Flat Back. 630mm x 450mm
Providing and fixing Vitreous China pedestal for wash basin complete recessed at the back for the reception of pipes & fittings:-.
Providing and fixing C.P brass waste for wash basin or sink. 32mm dia.
Providing and fixing PVC waste pipe 32mm dia
Providing and fixing 600mmx450mm beveled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with C.P brass screws and washer.
Providing and fixing 600mmx120mm glass shelf with C.P brass bracket and guard rail complete fixed to wooden plugs with C.P brass screws. (AT SMS RESIDENCE)
Providing and fixing P.V.C connection with brass unions :- (a) 300/ 450mm length :- (i) 15mm nominal bore .
Providing and fixing C.P bib cock 15 mm nominal size of approved brand.
3.70.Providing and fixing C.P brass angle cock 15 mm dia.
Providing and fixing one hole basin mixing Faucet. (Pillar Cock) Jaguar
Providing and fixing Toilet paper holder C.P. Brass
Providing and fixing Chromium plated brass soap dish with C.P brass brackets fixed to wooden cleats with C.P brass screws.
Providing and fixing C.P Brass towel ring of approved make.1 at each wash basin +1 at each Bathing area)
Providing and fixing C.P Jet of approved make
Providing and fixing concealed stop cock of superior make.(At Bathing Areas)
Providing and fixing C.P grating of approved make (Square Type). 100 mm.17 nos in building+6 at terraces
Providing and fixing. to wall ceiling and floor galvanized mild steel tubes (heavy grade) tube fitting & clamps i/c. Making good the wall, ceiling and floor.15mm nominal size.(22 nos. Pipes of 6meter)=132 meter including connection from IPH line near by
Providing and fixing G.I/M.I Union of 15 mm size
Providing and fixing brass full way valve wheel 15 mm(2 in Tanks + 2 at Ground Floor)
Providing and fixing Brass ball valve (Horizontal plunger type) 15mm nominal bore(In Each Water Tank)
Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete. 110 mm dia(18 Nos. Pipe of 3meter)=54 meter
Providing and fixing PVC single equal branch with oval access door ISI marked insertion rubber washer 3 mm thick bolts and nuts complete including fixing with approved adhesive etc. complete 110 mm dia.
Providing and fixing PVC collar ISI mark including fixing with approved adhesive etc. complete 110 mm dia.
Providing and fixing PVC plain bend ISI marked complete including fixing with approved adhesive etc. complete 110mm dia.
Providing and fixing PVC P and S trap for water closet plain bend ISI marked complete including fixing with approved adhesive etc. complete 110mm dia.
Providing and fixing 15mm mixer for kitchen sink with top/bottom swinging spout
Providing and fixing PVC floor trap ISI marked of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. complete. Ii) 110 mm X 75 mm.
Providing and fixing PVC clamps ISI marked of approved design with steel screws and rawal plugs etc. complete.(i) 110mm dia
Providing and fixing vitreous china bowl pattern urinal i/c connection the urinal with waste pipe by means of white lead mixed with chopped hemp (waste pipe to be measured and paid separately )
Constructing Brick Masonry Road Gully Chamber 500x 450x 600mm in Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Including 500x450mm C.I Horizontal Grating With frame complete.
Supplying and fixing C.I. cover without frame for manholes 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Providing and fixing plastic seat (Solid / Hollow type) and cover for wash down water closet with C.P. Brass hinges and rubber buffers Solid type a white plastic seat and cover
Providing and fixing PVC water tanks 1000 ltr capacity
Providing and fixing G.I Nipple 4’’ (heavy duty)
Providing and fixing PTMT urinal cock of approved quality and colour 15 mm.
Providing and fixing PTMT urinal spreader of approved quality and colour
Providing and fixing water meter including connections complete
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Cable Make: PLAZA/ UNITECH/ BONTON/ KEI/ BIYANI/ GEMSCAB/ CMI Group c.=(76+17+4)
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required. Make: ESS/ KAY /COSMO/ANCHOR
Supplying and fixing brass batten/angle holder including connections etc. as required:- Make: SSK/ CONA/ ANCHOR
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and erection of 6 amps to 32 amps. rating, 10 KA breaking capacity,240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required :- (Make: L&T /Legrand/ Siemens/ Anchor) Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required :-(Make: L&T /Legrand/ Siemens/ Anchor) Double pole-40 Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 mili ampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: L&T /Legrand/ Siemens/ Anchor) 40 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (Make: L&T /Legrand/ Siemens/ Anchor)
(i) Double door-4 way
(i) Double door-12 way
(ii) Double door-16 way
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
(i) 2x1.5 Sq. mm.
(ii) 2x4.0 Sq. mm.
(iii 2x6.0 sq.mm.
( iv) 2x16 sq.mm.
( v) 4x16 sq.mm.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Cable Make: PLAZA/ UNITECH/ BONTON/ KEI/ BIYANI/ GEMSCAB/ CMI
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. Cable Make: PLAZA/ UNITECH/ BONTON/ KEI/ BIYANI/ GEMSCAB/ CMI 3x1.5 Sq. mm.
Earthing with copper earth plate 600 mmx600 mm x 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Supplying and laying 6 SWG Copper wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.(Make: Usha Ultimate/Bajaj Ultima / Anchor Panasonic) Ceiling fan 1200 mm sweep Category -A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.(Make: Usha Ultimate/Bajaj Ultima/Anchor Panasonic)
Supplying and fixing brass batten/angle holder including connections etc. as required:-
Providing & fixing indoor decorative LED with integrated LED Channel engineering plastic batten with white acrylic cover of bajaj make cat No. : BCLSB 18 WH Complete with connection testing and commissioning etc. (Make: Wipro/Bajaj/Twinkle/ Phillips/ Anchor)
Providing & fixing LED Bulb 9Watt as per great white make w.e.f. 03-2017 Cat NoLED-009001.B/LED-6500K/2700K complete with connection testing commissioning etc. as required complete in all respect.
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.
100 Amp. -16 KA
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mm x 400mm x150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:-(1.00 x 0.75m) = 0.75sqm
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Providing and fixing 25mm x 5mm copper strip in 40 mm dia. G.I. pipe from earth electrode etc. as required.
Supplying and Fixing of metal box 200mm x150mm x75mm size with phenolic laminated sheet cover in recess I/C P/F 3Nos 6pin socket outlet 3Nos 5/6 amp switch connection as required (COMPUTER POINT)
Supplying and erection of street light bracket made of G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:- 40 mm dia. G.I. pipe, heavy class
M/s A.K. Builders
Sushil Kumar Govt Contractor
CP Dharma Contractor
CHANDER MOHAN
suman kumar sharma
Sanjeev Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .