Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.0 Cr+₹41.1 L (11.4%)Rejected-Finance | ₹4.0 Cr+₹41.1 L (11.4%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹4.1 Cr+₹50.6 L (14.0%)Rejected-Finance | ₹4.1 Cr+₹50.6 L (14.0%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹4.2 Cr+₹58.6 L (16.3%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹4.2 Cr+₹58.6 L (16.3%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹4.2 Cr+₹62.2 L (17.3%)Rejected-Finance 106 AGARWAL AND COMPANY PROFESSOR COLONY OPP OF WALL FORT CITY RING ROAD NO 01 RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | ₹4.2 Cr+₹62.2 L (17.3%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹3.7 Cr
EMD Value
₹4.5 L
Closing Date
4 Aug 2022, 6:00 pmClosed
Chief Engineer , Bhopal Zone, Bhopal
HQ , Chief Engineer , Bhopal Zone, Military Engineer Services ,Bhopal
ADDN/ALTN AND SPL REPAIR TO MD ACCN AT JHANSI CANTT
2022_MES_522583_2
CEBZ / JHA / TOKEN / 06 OF 2022-23
Open Tender
Civil Works
Item Rate
546 days
Jhansi
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Garrison Engineer Jhansi
₹4.5 L
Yes
12 Sept 2022
14 Jul 2022
6 Aug 2022
14 Jul 2022
4 Aug 2022
26 Jul 2022
Amount
Note: (i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
M&L for ATT, Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and as directed.
M&L for ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and as directed.
M&L for ATT of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
Dismantling of Bricks (laid flat or on edge) or brick tiles laid bedded and pointed in any mortar on roof slab etc (each layer) n. exc 15 cm thick complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust, etc. complete all as specified and as directed.
Brushing neat cement (Grey) slurry with 3.0kg of cement per Sq. metre complete all as specified and as directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for 40 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in padding levelling etc complete all as specified and as directed.
Rendering 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound as per manufacturers instructions, on concrete roof surface finished fair and even to maintain the proper slope of roof surface complete all as specified and as directed. (Note: Supply only water proofing compound shall be measured & paid separately)
Supply only integral liquid water proofing compound complete all as specified and as directed.
M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm weight not less than 3kg/Sqm as per manufacturer’s instructions with torch application complete all as specified and directed with following course of description:-
(a) After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repair the slab will be tested for water tightness again before proceeding with further treatment.
(b) the surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as fungus, moss, dust, etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.
(c) Bitumious based primer confiorming to IS: 3384 @ 0.3 kg/SM to be applied on prepared surface, till the surface is property impregnated.
(d) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer's instruction. The overlap while torching shall be 100mm in longitudinal direction and 100mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and seling it with the help of hot trowel. The overlap joints shall be made as a monolithic layer.
(e) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.
(f) Fourth course of Apply a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrane.
Demolition of Cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L of water proofing treatment to Sunken floor slabs of WC,Bath, Toilet & Kitchen with polymeric based chemicalas per manufacturer’s instructions over bottom & sides of sunken portion all as specified and directed by Engineer-in-Charge with following course of description below:- (a)Laying PCC 1:2:4 type B0 12.5 mm stone aggregate mixed with water proofing compound as per manufactures instruction of avg 25 mm thick on bottom portion of sunken with proper slope towards spout/spouts all as directed. (b) Vertical sides shall be plastered in CM 1:3, 15mm thick, mixed with water prrofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green ie PCC and plaster be carried out at the same time. (c) After laying all sewage/plumbing pipes with fixtures in position, apply 2 coat of polymeric based chemical as per maniufacturer instructions over bottom & sides of sunken portion. (Description of item continued on Ser item No 16.01)
(d) Test for water tightness by ponding for 72 hours and rectify defects if any till total elimination of defects. Note : 1. Work of water proofing treatment will be got executed by the contractor from the authorised applicator of the company form which the contractor sources the material. 2. All the material required for water proofing treatment will be procured by the contractor from same firm to ensure the quality of material. 3. Warranty for 10 years will be obtained from manufacturer by the contractor.
M&L PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in mass filling in two layer in sunken portion complete all as specified and as directed.
M&L, 50mm bore, G.I pipe as in spout to drain out water if any leakage occures in the sunken portion complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for Non - skid Ceramic tiles, 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Non - skid Ceramic tiles, 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting over and including 10mm thick backing coat in CM 1:4 on wall complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles 300x450x7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including including 10mm thick redering in CM 1:4 on wall complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars, etc complete all as specified and directed.
M&L, Brick work with sub class 'B' bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for two coats of rendering with 5 mm thick in CM 1:4 over and 10 mm thick in CM (1:6) on concrete/brick surfaces and finished surface even and smooth without using extra cement mixed with liquid water proofing compound complete all as specified and as directed. (Note: Supply only Water proofing compound shall be measured & paid separately)
M&L for rendering 5 mm thick in CM (1:3) on ceiling surface of chhajja, floor slab, balcony etc with treating exposed surfaces of steel and iron work, any descrption, width or girth, fixing with 12 mm wire netting of galvanised steel wire, 1.40 mm dia and grouted with cement slurry mixed with concrete bonding agent 200 ml in 50 Kg weight of cement and making good the surface even & fair including necessary staging and scaffolding complete all as specified and directed
S&F, in repair, Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling, 32 mm PVC Waste pipe 600mm long complete all as specified and directed.
S&F, in repair, Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests complete all as specified and as directed.
S&F, in repair, Vitreous China wash down water closet pan (pedestal pattern), EWC, coloured including jet system & matching coloured seat cover fixed complete all as specified and as directed.
S&F, in repair, 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, low level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long and PVC 32 mm dia flush pipe complete all as specified and as directed.
Taking down and refixing only on same or other location as directed, 10 Litres, PVC flushing Cistern low level and brackets including PTMT PVC connection 600mm long and PVC 32 mm dia flush pipe complete all as specified and as directed.
S&F, in replacement of PVC connection 600 x 15mm dia PTMT (PVC) complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed.
M&L for cutting chases, pinning in brick walls for concealed water tubing n.exc 10cm girth and making good facing where required and pointing in CM 1:3 complete all as specified and as directed.
S&F, 15 mm bore, Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F, 20 mm bore, Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Fixing only, 15 mm bore, Galvanized Steel tubes, medium grade including cleaning etc for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Fixing only, 20 mm bore, Galvanized Steel tubes, medium grade including cleaning etc for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F, in repair, 15 mm bore Bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Fixing only, in repair, 15mm bore Bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F, in repair, Pillar taps, 15 mm bore, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, complete all specified and directed.
Fixing only, in repair, Pillar taps, 15 mm bore, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, complete all specified and as directed.
S&F, in repair, 15 mm bore stop/angle cock, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all specified and as directed.
S&F, in repair, 15 mm bore conceald stop cock fancy type, chromium plated with long shank and cup screwed down, screwed for iron pipe or for brass ferrule complete all specified and as directed.
S&F, in repair, PTMT grating doom 100 mm dia and fixed with CM to floor/nahani traps etc, complete all specified and as directed.
S&F, PVC (SWR) pipe of 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all specified and as directed.
S&F, PVC (SWR) pipe of 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all specified and as directed.
S&F, PVC Nahani/ floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and as directed.
S&F, 110 mm bore PVC (SWR) bends with access door of any radius, complete all as specified and as directed.
S&F, 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
S&F, PVC (SWR) vent cowl 75mm bore, jointing to waste pipe, complete all as specified and directed.
S&F, PVC(SWR) vent cowl 110mm bore, jointing to waste pipe, complete all as specified and directed.
Demolition of cement concrete in ground floor including terrazo flooring and paving not exc 15cm thickness (below or above the ground level) built in cement mortar complete all as specified and directed.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern complete all as specified and as directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) complete all as specified and as directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame) complete all as specified and as directed.
Taking down shutters of any description exc 1.0 Sqm but not exceeding 2.00 Sqm each complete all as specified and as directed.
Demolition of reinforced cement concrete not exc 15cm thickness Roofs, floors (other than ground floors), beams staircases, landing, chajjas, Cover slab and similar suspended work complete all as specified and as directed.
Demolition of cement concrete of any description and in any position of WC’s/Bathroom etc in sunken portion area above ground floor, removing demolished material completely and old waste pipe from sunken portion and cleaning the side/bottom surface of sunken floor with wire brush, complete all as specified and directed.
Demolition existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime concrete etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed.
Dismantling for Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry and pointed in any mortar complete all as specified and as directed.
Dismantling water tank exc. 250 litres & not exc. 500 litres capacity of tanks, complete all as specified and directed.
Dismantling of wall / ceiling boards of any thickness including cover fillets etc complete all as specified and directed.
Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering, complete all as specified and directed.
Dismantling of Framed timber scantling 40sq cm and over in section in any position complete all as specified and directed.
Dismantling of Framed timber fillet, rails, post, rafters, purlin etc n. exc 40sq cm in section in any position complete all as specified and directed.
Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two layers (first coat 10 mm & second coat of 5 mm) mixed with WPC as per menufacturers intructions, finished even and smooth without using extra cement complete all as specified and as directed. ( Note: Supply only Water proofing compound shall be measured & paid separately)
Rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:4 surface finished even and smooth without using extra cement complete all as specified and as directed..
Preparing newly plastered surfaces of wall and applying two coats of oil bound distember over and including 1 mm thick cement putty and a coat of chalk whitening primer preparating to make the surface to be plain and smooth before primer complete all as sppecified and directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Complete removal of exisiting treatment, washing rubbing of old treatment and applying three coats of white wash on wall sufaces complete all as specified and as directed.
Complete removal of exisiting treatment, washing rubbing of old treatment and applying three coats of white wash on ceiling sufaces complete all as specified and as directed.
Complete removal of exisiting treatment, washing and rubbing of old distempered surfaces and applying two coats of oil bound distember over and including 1 mm thick cement putty and a coat of chalk whitening primer preparatory to distemering complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying a coat of Synthetic enamel paint (Ordinary tint) complete all as specified and as directed.
Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed.
Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for jointless Non - skid Ceramic tiles, 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for jointless Non - skid Ceramic tiles, 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting over and including 10mm thick backing coat in CM 1:4 on wall complete all as specified and directed.
M&L for jointless Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for jointless Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4 on wall complete all as specified and directed..
M&L for machine cut Kota stone slab flooring 20-25 mm thick and laid over and including 20 mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.
M&L for machine cut Kota stone slab, 20-25 mm thick and laid over and including 10 mm thick rendering in CM (1:4), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, on vertical surfaces such as skirting/dado etc with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.
M&L for Green marble 18/20 mm thick over and including 15mm thick screed bed in CM 1:6 as in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Granite stone slab, 20 mm thick over and including 10 mm thick CM 1:4 (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rubbing and polishing complete all as specified and as directed.
M&L for 75mm PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 finished even and smooth without using extra cement including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) (1 part bitumen 85/25 and 3 parts of sand ) complete all as specified and directed. {Note:-Bitumen mastic will measured and paid seperately}
M&L for forming construction joint 30 mm deep x 10 mm wide and filled with bitumen mastic Grade Á' all as specified and directed.
S&F, in repair, Aluminium Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed
S&F, rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as specified and directed.
S&F, rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as specified and directed.
S&F, in repair, 20 mm bore Ball valve, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed.
S&F, in repair, 20 mm bore Gun-metal, ISI, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F, in repair, 15 mm bore, Bib tap, long body, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F, Stainless Steel grating, square/round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and including fixing with cement mortar to floor/nahani traps complete all as specified and directed.
S&F, in repair, PVC connection 450 x 15mm dia, PTMT (PVC), complete all as specified and directed.
S&F, in repair, Chromium plated shower rose, 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F, in repair, SS Towel Rail, 600mm Long fixed with and including chromium plated brass screws complete all as specified and directed.
S&F, in repair, Brass CP connection 15mm dia and 45cm long with 2 Nos brass check nuts with washers for geyser, complete all as specified and directed.
S&F, PVC (SWR) pipe of 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all specified and as directed.
S&F, PVC (SWR) pipe of 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all specified and as directed.
S&F, 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F, 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
M&L for mild steel framed work section as in door or gates of angle or other section with gusset plates,rails braces etc /windows chowkhats/Shutter frame of steel gate of grade Fe-290 (Gde E-165) including all necessary machine wks i.e. cutting, welding, grinding etc, complete all as specified and directed.
M&L for mild steel hold fast and similar small articles conforming to Fe-290 Gde-165, complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 (12.5mm graded aggregate) for bed block for fixing of chowkhats, cills, pre-cast lintel n.exc 1.5mtr, coping, benching, etc complete all as specified.
S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc.
S&F, 30mm thick flush shutter doors, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&F, Solid PVC door frame of size 50mmx47 mm single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified in SSR Part-II 2010 section 8.
S&F, Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F, 18/19mm thick pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work for cupboard shutter complete all as specified and directed.
S&F, in repair, Block boards 18/19mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete as per the specifications and as directed.
S&F, Box type steel windows with 80x40x1.25mm RHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C (Ref TD No CEBZ/TD/14/ 2011) including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed.
S&F, Box type steel Ventilator with 80x40x1.25mm RHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C (Ref TD No CEBZ/TD/14/ 2011) including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed.
S&F, Continuous (piano) hinges, mild steel, 30 mm width of flap (when open), bright finish or electrogalvanised, complete all as specified and directed
S&F, magnetic catcher for fixing in cupboard, to hold the shutter in closed position, all as per sample complete all as specified and directed
S&F, 100mm butt hinges, medium weight, cold rolled mild steel and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.
S&F, 75mm butt hinges, medium weight, cold rolled mild steel and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.
S&F, 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed with screws, complete all as specified and directed.
S&F, 150mm long mild steel pressed handles, oval type, stove enamelled black and fixed with screws, complete all as specified and directed.
S&F, 300mm long mild steel, sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and incl minimum of 6 bolts and nuts, complete all as specified and directed.
S&F, 200 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F, 150mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F, 100mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F, 150mm aluminum handle cast type anodized complete all specified and directed.
S&F, 100mm aluminum handle cast type anodized complete all specified and directed.
S&F, mild steel ordinary rat tail rod pattern springs of size 300mm including roller and roller plate complete all as specified and directed
S&F, Door stopper 140 mm of aluminium alloy body anodised with tongue of rubber bush at one end fixed to door complete all as specified and directed.
S&F, Rubber bush of 25mm long as per sample, fixed to door complete all as specified and directed.
S&F, 125 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as directed.
S&F, 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S&F, 3mm thick sheet glass frosted/figured and pin headed glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S&F, stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
S&F, in repair, Aluminium anodised curtain rod 25mm dia with caps/lobs and wall mounting bracket, all as per sample, cutting in to length required at site complete all as specified and directed.
S&F, stainless steel kitchen plate rack size 750x 600x230 mm, thickness of sheet not lessthan 1mm, all as per sample, including fixing arrange ment to walls with rawel plug or wooden plugs complete all as specified and directed..
S&F, sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste cupling, wastepipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L, RCC, M-25 (Design Mix), using 20 mm graded stone aggregate as in beams and the like complete all as specified and directed.
M&L, RCC, M-25 (Design Mix), using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L, RCC, M-25 (Design Mix), using 20 mm graded stone aggregate as in chajjas and the like complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
Form work to flat soffits of suspended slabs such as roof slabs, floor slabs and lintels, landing and similar work n exc 200mm thick for fair finished surface of concrete complete all as specified and directed.
Form work to flat chullah hoods, chajjas, troughs and similar items including edges etc. for fair finished surface of concrete complete all as specified and directed.
Form work to sides and soffits of flat floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surface of concrete complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide for fair finished surface of concrete complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces mixed with liquid water proofing solution to vertical surface complete all as specified and directed. Note:- Liquid water proofing solution shall be provided 150ml in 50 Kg of Cement by weight and supply only liquid water proofing solution shall be measured and paid seperately.
M&L, 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in padding levelling etc and roof kerbs with liquid water proofing solution finished even and fair with proper slope as prepatory works to water proofing treatment complete all as specified and directed. Note:-Liquid water proofing solution shall be provided 150ml in 50 Kg of Cement by weight and supply only liquid water proofing solution shall be measured and paid seperately.
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm weight not less than 3kg/Sqm as per manufacturer’s instructions with torch applicationcomplete all as specified and directed by Engineer-in-Charge with following course of description below:- (a) After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repaireds the slab will be tested for water tightness again before proceeding with further treatment. (b) the surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) Description of item continued on Ser item No 156.01
around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners. (c) Bitumious based primer confiorming to IS: 3384 @ 0.3 kg/SM to be applied on prepared surface, till the surface is property. impregnated. (d) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer's instruction. The overlap while toching shall be 100mm in longitudinal direction and 100 mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and seling it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. (e) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. (f) Fourth course of Apply a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
S&F, exposed frame false ceiling system with GI powder coated grid consisting of interlocking arrangement of main T runner of 15mm size, suspended at 1200mm C/C and cross T runner of 15mm size suspended at 600mm C/C supported by 1.5mm dia GI wire from roof/Slab/truss including wall/perimeter runner/channel of 15 mm size with and including 4mm thick pre-painted non asbestos fiber reinforced cement board (E-board), designer type of size 595x595mm, duly fixed in ceiling frame work, complete all as specified and as directed.
S&F, pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed.
S&F, pre-painted Galvalume Aluminium Zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 MPa and AZ 150 grade as in ridge of roof covering, fixed with self tapping screws, complete all as specified and directed.
M&L, Structural steel Fe-410-W(Gde-E-250) quality B for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed.
BLANK
BLANK
S&F, 15mm bore, CP brass mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all specified and directed.
Preparing newly plastered surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of primer complete all as specified and directed.
Complete removal of exisiting treatment, washing and rubbing of old surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of exterior grade cement based primer complete all as specified and directed.
M&L for Kitchen cabinets, made of 18 to 20mm thick PVC solid sheet with one side of wooden texture decorative surface, including necessary cutting of sheet in to size, joining with screwes and adhesive fixing to wall with screws, with and including necessary fitting i.e. self closing type hydraulic hinges, SS handle, telescopic type ball bearing slide & runner suitable for drawers and megnetic lock for Kitchen cabinets, PVC bidding tape, complete cabinet(s) make in full width of plateform (max 600mm width), consist of min 05 Nos of kitchen cabinets complete all as specified and as directed with the followings :- (a) Minimum Two nos cabins, completely (all around) covered with PVC sheet with one door with one or two leaf shutter and one shelf in full depth made out of same materials. (b) One No cabin, completely (all around) covered with PVC sheet with three drawers in full depth made out of same materials, The size of drawers shall be decided accordingly to site dimension and requirement. (c) Two Nos cabin completely (all around) covered with PVC sheet with front door having one or two leaf shutter or only with front door. Note : (i) The size of cabins/drawers shall be decided according to site dimension and requirement. (ii) The complete work shall be carried out in line, level and proper finished manner and without any gap in joints and all as per sample displayed. (iii) Net Opening (L X H) shall be measured for payment purpose.
M&L for kitchen cabinets, wall hanging type, made of 18 to 20 mm thick PVC solid sheet with one side of wooden texture decorative surface, including necessary cutting of sheet in to size joining with screwes and adhesive fixing to wall with screws, with and including necessary fitting like self closing type hydraulic hinges, SS handle, PVC bidding tape, kitchen cabinets consists of No of cabins having depth of 350mm of required size, All cabins having door(s) with one or two leaf shutter of same materials, complete all as specified and as directed . Note : (i) The size of cabins/drawers shall be decided accordingly to site dimension and requirement. (ii) The complete work shall be carried out in line, level and proper finished manner and without any gap in joints and all as per sample displayed. (iii) Net Opening (L X H) shall be measured for payment purpose.
Surface dressing not exceeding 15 cm deep in hard / dense Soil complete all as specified and directed
M&L, 75 mm thick cement concrete type C-2 (1:3:6) using 40 mm graded stone aggregate as in sub base of flooring/ hard standing complete all as specified and directed.
M&L, factory made, PU coated, machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment made of PVC moulded (or rubber mould) with vibrating system, laid over sand cushioning complete all as specified and directed. Note : The cost of sand cushion is measured and paid separately.
M&L for sand filling under floor or in foundations including watering and consolidation, complete all as specified and directed
M&L for PCC Type B-0, 1:2:4 (using 12.5 mm Stone Aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, kerb stop rounded or chamfered in edges complete all as specified and directed
M&L, PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in in foundation, filling and mass concrete complete all as specified and directed
M&L for PCC Type B-1 (1:2:4) using 20mm Stone Aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, kerb stop rounded or chamfered in edges complete all as specified and directed
Excavation in trenches not exc 1.5m wide & not exc 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes etc and getting out in hard/dence soil complete all as specified and directed.
Excavation in trenches not exc 1.5m wide & exceeding 1.5m but not exceeding 3.0m depth for foundation etc or for shafts, wells, cesspits, manholes etc and getting out in hard/dence soil complete all as specified and directed.
Excavation over areas, n exc 1.5 m deep and getting out in hard dense soil complete all as specified and directed.
Excavation over areas, exceeding 1.5m and not exceeding 3.0m deep and getting out in hard dense soil complete all as specified and directed.
Demolition and breaking of drains pipe (Salt glazed stone were, AC or re-inforced concrete) set in cement mortar 150 mm internal dia pipe complete all as specified and directed
Demolition and breaking of drains pipe (Salt glazed stone were, AC or re-inforced concrete) set in cement mortar 200 mm internal dia pipe complete all as specified and directed.
M&L, 150mm bore, reinforced concrete pipes, class NP2, as per IS 458 (2003) code, laid and jointed with skeins of spun soaked in neat cement wash shall be inserted in the grooves at the ends of the pipes, the two adjoining pipes put against each other the collar is slipped over the joint covering equally both the pipes, more skiens of spun yarn soaked in cement wash shall be passed round the pipes and inserted in the joints by means of caulking tools after that cement mortar 1:2 slightly moistened shall be inserted in the joints finished in 45 degree slope complete. Note:- After curing 7 days to the joints the sewage pipe shall be tested as per procedure laid down for water test.
M&L, 200mm bore, reinforced concrete pipes, class NP2, as per IS 458 (2003) code, laid and jointed with skeins of spun soaked in neat cement wash shall be inserted in the grooves at the ends of the pipes, the two adjoining pipes put against each other the collar is slipped over the joint covering equally both the pipes, more skiens of spun yarn soaked in cement wash shall be passed round the pipes and inserted in the joints by means of caulking tools after that cement mortar 1:2 slightly moistened shall be inserted in the joints finished in 45 degree slope complete. Note:- After curing 7 days to the joints the sewage pipe shall be tested as per procedure laid down for water test.
M&L, concrete bed to drain pipe for 150 mm bore pipes, with PCC (1:4:8) type D2 using 40 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L, concrete bed to drain pipe for 200 mm bore pipes, with PCC (1:4:8) type D2 using 40 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Returning / filling in including spreading, levelling, watering and well ramming in layers not exceeding 250mm with excavated hard/dence soil complete all as specified and directed.
Removing excavated material (Soil) not exc 50 m and depositing where directed at a level not exeeding 1.5 m above the starting point complete all as specified and directed.
M&L, Precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slabs including necessary form work and set in cement mortar 1:6 complete all as specified and directed.
M & L cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm internal dia of pipe. complete all as specified and directed.
M & L cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200mm internal dia of pipe. complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in concrete, brick work, masonry etc. including taking out embedded portion and making good disturbed ground complete all as specifide and directed.
Dismantling fencing wire mesh, any type complete all as specifide and directed.
Excavation in post hole (similar hole) in any type of soil, each post hole not exceeding 0.5 Cum, getting out, returning filling in and ramming, complete all as specifide and directed.
M&L for mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths) and flat Iron for posts and struts and straining bars in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing fencing etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165, complete all as specifide and directed.
Supply only Chain link MS galvanisd fencing, of mesh size 63 x 63 mm and dia of wire 4mm, fixed to any type of standards, rails, straining bolts etc, including provision of binding wire, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Taking down carefully aluminum / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switches, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, 60 mm deep with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points:-
One light /bell point controlled by one switch
One ceiling fan point controlled by one switch and regulator
One exhaust fan point controlled by one switch
One ventilating fan point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per BOQ Srl item No. 197 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor including taking down old unserviceable sub main wiring of any description, complete all as specified and directed for the following sizes:- Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
(a) 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm (earth wire)
(b) 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
(c) 4runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
Supply and fixing switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fixing socket 6 Amps, 2-in-1, 5 pin flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fixing socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fixing Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and directed.
Supply and fixing bell push switch flush type 6 Amps, 240V, 50Hz complete all as specified and directed.
Supply and fixing call bell ding dong, AC, 240V, 50Hz complete all as specified and directed.
Supply and fixing ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.
Supply and fixing electronic fan regulator rotary type in 5 steps 240V, 50Hz complete all as specified and directed.
S&F, 7 W, LED lamp, retrofit type suitable for B-22 holder base with polycarbonate diffuser complete all as specified and directed.
Supply and fixing, LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing, LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F, LED light fitting 1x9W/1X10W, bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing, LED street light fitting, 35 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed.
Supply and fixing, electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Supply and fixing, exhaust fan, steel body, AC single Phase. 230V of size 300m sweep with blades, frame, louvers, etc complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Taking down existing old ceiling / exhaust fan of any size carefully and sealing cable end, dismantling blades and removing fan and blades and depositing to AGE E/M store yard complete all as specified and directed.
Taking down existing old geyser of any size carefully and deposited to AGE E/M store yard complete all as specified and directed.
Supply and fixing, MCCB / MCB distribution board, VTPN, 4 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCCBs / MCBs shall be measured and paid separately.
Supply and fixing, MCB distribution board, TPN, 4 way with in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface , including taking down old unserviceable TPN / DB of any description, all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fixing, MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface, including taking down old unserviceable SPN DB of any description all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fixing, MCB distribution board, SPN, 4 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fixing, MCCB, 125A, 16 KA, 4 Pole complete all as specified and directed.
Supply and fixing, MCB 40 - 100A, 10 KA, TPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Supply and fixing, MCB 40A - 63A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Supply and fixing, MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 35 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
M&L for High density polyethylene pipes (HDPE) 50mm bore, pressure rating 6 kgf/cm2 laid in trenches/floors/duct or fixed on walls /pole for cable protection complete all as specified and directed.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of cables / pipe and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 after laying of pipes, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing beyond 15Cm depth shall be measured and paid under relevant items.
M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.50mtrs below normal ground level connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth strip protection by 15 mm bore light grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover, reinforced with 8mm TMT bars 100mm C/C both ways with life hook made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. (Description of item continued on Ser item No 232.01)
including taking down old unserviceable earthing of any description Note. (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth wire and earh wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself
Supply and fixing, Hot Press Molded SMC meter box of size not less than 700mm X 480mm X 200mm, double door with transparent glass windows for viewing the meter reading without opening the door, minimum IP-43 degree of protection for indoor use for accommodating 04 Nos X 1 Phase 2 Wire energy meter including cutting the wall surfaces for flush mounting of meter box and making good with cement plaster, putty and paint to match with the existing surface etc as per site requirement, including taking down old unserviceable earthing of any description complete all as specified and directed.
Raja enterprises
M/S JAWAHAR LAL SHARMA
BHARAT MULTITECH INDUSTRIES PVT LTD
agarwal and company
HEMKUND STEEL INDUSTRY
m/s jethanand bhatia
NIHAL ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .