Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹32.6 LAdmitted-Finance SB 12 BHAWANI SINGH ROAD BAPU NAGAR JAIPUR RAJASTHAN 302015 | JAIPUR | RAJASTHAN | 302015 | L1 | Admitted-Finance | ||
| 2 | L2₹36.8 L+₹4.2 L (12.9%)Admitted-Finance 1 B 8 MARWA HOUSE M I ROAD NEW COLONY JAIPUR RAJASTHAN 302001 | JAIPUR | RAJASTHAN | 302001 | L2 | Admitted-Finance |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
12 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
PWD Electrical Division I Jaipur
Electrical upgradation and Strengthening work at Court Campus Jaipur District Court, Jaipur.
2026_CEPWD_605214_9
NIT NO 18 of 2026-27 EE PWD E-I Jaipur
Open Tender
Electrical Works
Percentage
120 days
Court Campus Jaipur District Court
Please refer tender documents
2 documents required · 2 mandatory
₹500
Through Egras Challan in Office ID 4222
₹62,000
Yes
In the Chamber of Executive Engineer
16 Nov 2026
2 Nov 2026
13 Nov 2026
2 Nov 2026
12 Nov 2026
2 Nov 2026
4 Nov 2026
70 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Providing & Fixing of on load change over switch, front handle operated, four pole 415 V confirming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Open execution type .400 A | 2 | Each | 24,559 | ₹49,118 |
| 1.02 | Providing & Fixing of on load change over switch, front handle operated, four pole 415 V confirming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Open execution type .800 A | 1 | Each | 41,884 | ₹41,884 |
| 1.03 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.400.0 Sq. mm.3.5 core | 140 | Mtr | 2,372 | ₹3,32,080 |
| 1.04 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.50.0 Sq. mm.3.5 core | 60 | Mtr | 435 | ₹26,100 |
| 1.05 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.70.0 Sq. mm.3.5 core | 50 | Mtr | 581 | ₹29,050 |
| 1.06 | Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth. | 80 | Mtr | 145 | ₹11,600 |
| 1.07 | Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same | 80 | Mtr | 44 | ₹3,520 |
| 1.08 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).120 mm | 20 | Mtr | 246 | ₹4,920 |
| 1.09 | Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.600mm x 62.5mm x 2.0mm | 6 | Mtr | 1,839 | ₹11,034 |
| 1.1 | Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.300mm x 62.5mm x 2.0mm | 10 | Mtr | 1,078 | ₹10,780 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Tendernotice_2.pdf
PDF • 2.29 MB
Tendernotice_3.pdf
PDF • 0.22 MB
BOQ_1073279.xls
BOQ • 0.37 MB
Cover9.pdf
Tender Documents • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .