Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | ₹17.1 L | L1 | Accepted-AOC AOC |
| 2 | L2₹17.1 LSame as L1Rejected-Finance | ₹17.1 LSame as L1 | L2 | Rejected-Finance Selected through transparancy lottery |
| 3 | L2₹17.1 LSame as L1Rejected-Finance AT PO PS KHANDAPADA DIST NAYAGARH | ₹17.1 LSame as L1 | L2 | Rejected-Finance Selected through transparancy lottery |
| 4 | L2₹17.1 LSame as L1Rejected-Finance AT PLOT NO 2047 SABARASAHI LANE KALPANA SQUARE BHUBANESWAR KHORDHA ODISHA | BHUBANESWAR | KHORDHA | ODISHA | ₹17.1 LSame as L1 | L2 | Rejected-Finance Selected through transparancy lottery |
| 5 | L2₹17.1 LSame as L1Rejected-Finance AT RAMPAS LAXMINAGAR PO FC PROJECT JAJPUR ROAD JAJPUR | JAJAPUR | ODISHA | 755019 | ₹17.1 LSame as L1 | L2 | Rejected-Finance Selected through transparancy lottery |
Tender Value
₹20.1 L
EMD Value
₹20,083
Closing Date
29 Dec 2025, 5:00 pmClosed
Superintending Engineer
O/o the S.E, Nayagarh RandB Division
Construction of 11 KV line with installation of 250 KVA 11/0.4 KV S/S towards electrification of JMFC, Khandapada in the district of Nayagarh.
2025_EICCL_123541_7
eTCN09 of 2025-2026
Open Tender
Electrical Works
Percentage
120 days
Nayagarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹20,083
Yes
7 Aug 2026
22 Dec 2025
30 Dec 2025
22 Dec 2025
29 Dec 2025
22 Dec 2025
Supply and Installation of 3 Ph Smart Meter at 250 KVA DSS 3Ph Smart Meter
MATERIALS FOR 11 KV Cut Point with 90 Degree Angle 11 KV pin insulator polymer
H W fitting(B&S) 70KN, 3Bolt
Disc insulator (B&S) 70 KN polymer
WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
POLYCARBONATE BIRD GUARD
MATERIALS FOR 11 KV Pin Points With WPB 55 sq.mm AAA conductor
MATERIALS FOR PLINTH MOUNTED DSS(250 KVA) WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP (Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
LT Cable raising Channel(GI) 75x40x4.8 mm GI Channel(GI) (1000 mm long)(7.14Kg./Mtr., 6 No's.) (Each 6x1.000x7.14= 42.84 Kg)
Top Channel(GI) GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)
AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required =( 9.56x2x0.35)
Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1)
HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
Double Pole Belting Channel(GI) 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 3.0 Mtr., 2 no's Channel(GI) required =( 7.14x3x2)
50x50x6mm.GI Bracing Angle(GI), 4.5Kg./mtr., each Angle(GI) length 3.512 mtr., 2 nos Angle(GI) required = (4.5x3.512x2)
50x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)
250 KVA , 11/ 0.4 KV (Cu) Transformer with Tap Changer BIS Energy Loss level II, Ammendment-4
LT Distribution Box with MCCB, Aluminium Busbar for 3 Bay with kit kat fuse for 250 KVA S/S
55 SQ.MM. AAAC XLPE Covered Conductor
1 Cx 630 mm2 LT XLPE Cable(Un-Armoured)
LT Cable Supporting Channel(GI) 100 X 50 X 6 MM GI Channel(GI) (2000 mm long)(9.56 Kg./Mtr., 2 No's.) (Each 2x2x9.56= 28.56 Kg)
LT Cable Supproting Angle(GI), 50x50x6mm.GI 4.5Kg./mtr., each Angle(GI) length 2 mtr., 4 nos Angle(GI) required = (4.5x4x2)
AB Switch(11KV,200A.3pole,50Hz)
DO Suse
20Amp Fuse Link
WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
POLYCARBONATE BIRD GUARD
Disc insulator (B&S)70 KN polymer
H W fitting (B&S)70KN(3bolted)
Lightning Arrester(12KV,10KA) Station Class 2
11KV pin insulator polymer
HT stay set complete
HT stay Clamp (1.9Kg/pair)
HT stay insulator TYPE-C
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
GI Barbed wire/Anticlimbing device (3Kg /Pole)
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510)
Danger plate 11kv
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510)
Name plate
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
Civil and Services Works Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) (For WPB Pole)
Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole)
PCC ratio 1:3:6(M-10 Grade) For DSS Area (3.5X2.5X0.1)= 0.875 Cu. mtr.
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
LTDB Plinth
DTR Plinth
Laying of 1.1kV cable from 400 to 1000sqmm
SITC and Erection of GI Fencing with Gate
Supply of AL Lugs suitable for 400 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
Supply and erection of double Compression Flameproof Type Glanding for armored Cable 1C 300-1000 sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells.
MATERIALS FOR LT AB Cable Line WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP (Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
LT Stay set Complete
7/12 SWG GI stay wire, Grade -2
LT stay Clamp ( 1.40Kg/pair)
LT Stay insulator
Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
EYE hook for XLPE Aerial bunched Cable
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
Suspension Clamp with EYE hook for ABC
4C×35 mm² (P)+1C×35 mm² + 1CX16 MM2 (M) ( Street Light) (LT AB Cable)
Insulated piercing connector.Type-B-main 25 to 150 sq.mm & Tap-6 to 35 sq.mm
GI Pipe Earthing (each 5th pole to earth)
Coil Earthing
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
Danger plate (LT)
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg. Per support
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)
Black Paint(GIS Numbering & Zebra Stripping)
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
Civil & Services Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole)
Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole)
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
UG Cable Supply Portion Supply of 1.1Kv, 4Core, 70 Sqmm, XLPE insulation armoured Aluminium UG Cable
Erection Portion Laying, Commissioning, Testing of 1.1Kv, Aluminium, XLPE insulation armoured UG cable by open trench method Laying of 1.1kV, 4Core, 70 sqmm, XLPE insulation armoured -Aluminium UG cable
Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 50-95sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells.
Civil Portion Earth work of excavation normal soil Trench Dimension: (1.6 mtr W X 1.275 mtr D)
Earth work of excavation hard rock Trench Dimension: (1.6 mtr W X 1.275 mtr D)
Backfilling with excavated soil outside and above the trench
PCC (1:3:6(M-10 Grade)) below trench (width 1500mm, thickness 75mm throughout)
Supply and erection of materil for RCC partition slab 750mmX100mm (M-25 grade)
Supply and erection of material for RCC trench, 150mm thick (M-25 grade)
Supply and erection of rod, bending, cutting and binding of RCC trench (65.23 KG/cum)
Supply and erection of rod, bending, cutting and binding of RCC slabs (67.8 KG/cum)
Centring & shuttering for mass concrete
Structural steel work riveted (Channel(GI)- 75mmX40mmX4.8mm), (Flat(GI)- 75mmX6mm)
Inspection Charges
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.30 MB
DTCN0909.pdf
Tender Documents • 1.12 MB
BOQ_572502.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .