| 1 | L1₹93.0 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹98.1 L+₹4.7 L (5.01%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L1 | ANIKET TRADERS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, fixing and erection in replacement of 4m MS ERW pipe decorative pole with base, aesthetically designed Jet black(RAL 9005) painted, galvaninsed (>35 microns)pole in different cross section with golden yellow colour decorative ring & joint reducer embellishment of aluminium die casting including base plate of size 200x200x10mm thick, (as per manufacture approved Drg) M16 x450mm foundation and nuts & bolts along with template. The external surface of the pole should be finished by single layer primer and double layer of anti-corrosive polyurethane paint (>=50 microns). The pole should be 3mm thick, min dia meters at the bottom is 114mm and 3mm thick at the top is 60mm suitable for 45-watt LED Post top light decorative circular design, accessories complete all as specified and directed. Flushed type Window/ door opening along with 6A MCB SP and 4-way 25sqmm cable connector block 32A with locking arrangement at 600 mm above base plate. Inspection will be done by Engr in Charge before dispatch along with test report. Before placing the order the sample piece to be approved by GE. Some Pole shall be laid at new place the credit of it will not be catered in Sch of Credit.
Make : Bajaj CAT Part No BJPL02 4m ECO POLE (TOP Dia 60mm) or equivalent in Philips/Havells/Wipro
Notes :-
(i) Foundation shall be made as per the manufacture design.
(ii) All provisions shall be made as per the drawings attached on serial Page No 80 (A).
(iii) Tolerance on thickness and dimension shall ne as per relevant standards.
(iv) Grade of pipe shall be YST-210.
(v) External surface of pole should be finished by primer and polyurethane paint. | 72 | Each | 18,500 ₹13,32,000 | 16,000 ₹11,52,000 Lowest |
| 2.00 | Supply & fixing in replacement of decorative Circular, aesthetically designed LED Post Top light, 45 watt 3000K, 50000 Burning hours of maintenance output & 4500 lumens output & CRI>80, IK 10 with optical grade PC diffuser,Pressure die cost aluminium single body and IP66 , anti corrosive epoxy powder coated, the dia of the light suitable for top of the pole dia 60mm complete all as specified and directed.Before placing the order the sample piece along with above quoted pole to be approved by GE. Some lights shall be laid at new place the credit of it will not be catered in Sch of Credit.
Make : Bajaj CAT Part No BL ARCHNER PRO NX 45W 3K C3 S / Havells CAT Part No.RINKPT45WLED757PSYMTOPC or equivalent in Philips/Wipro | 72 | Each | 4,500 ₹3,24,000 Lowest | 9,500 ₹6,84,000 |
| 3.00 | Supply, fixing and erection in replacement of 4m MS ERW pipe decorative Pole with decorative double Arm bracket suitable for 45W Post top as per attached drawing/image, aesthetically designed Jet black(RAL 9005) painted, galvaninsed (>35 microns)pole in different cross section with golden yellow colour decorative ring & joint reducer embellishment of aluminium die casting including base plate of size 250x250x10mm thick, (as per manufacture approved Drg) M16 x450mm foundation and nuts & bolts along with template. The external surface of the pole should be finished by single layer primer and double layer of anti-corrosive polyurethane paint (>=50 microns). The pole should be 3mm thick, min dia meters at the bottom is 114mm and3mm thick at the top is 60mm suitable for 45-watt LED Post top light decorative circular design, decorative 10 sqmm rod designed versatile brackets and Double Arm brackets and including all fixtures, accessories complete all as specified and directed. Flushed type Window/ door opening along with 6A MCB SP and 4-way 25sqmm cable connector block 32A with locking arrangement at 600 mm above base plate. Inspection will be done by Engr in Charge before dispatch along with test report. Before placing the order the sample piece to be approved by GE. Some Pole shall be laid at new place the credit of it will not be catered in Sch of Credit.
Make : Bajaj CAT Part No BJPL 06 4M ECO POLE WITH DA BRACKET (TOP Dia 60MM) or equivalent in Philips/Havells/Wipro
Notes :- (i) Foundation shall be made as per the manufacture design.
(ii) All provisions shall be made as per the drawings attached on serial page No 80 (B).
(iii) Tolerance on thickness and dimension shall ne as per relevant standards.
(iv) Grade of pipe shall be YST-210.
(v) External surface of pole should be finished by primer and polyurethane paint. | 78 | Each | 23,900 ₹18,64,200 Lowest | 25,000 ₹19,50,000 |
| 4.00 | Supply & fixing of decorative aesthetically designed LED luminaire Post Top light, 45 watt 3000K , With 50000 Hurning hours of maintenance output & 4950 lumens output & CRI>70, IK 08 with aluminium housing & Al heat sink and optical grade UV resistant PC diffuser,IP 66 with powder coated. The dia of the light suitable for top (48mm)of the double arm bracket as above complete all as specified and directed. Inspection will be done at the Factory premises before dispatch along with test report. Before placing the order the sample piece along with above quoted decorative double Arm bracket to be completed and approved by GE .
Make : Bajaj CAT Part No BOR NX 45W 30K DO C3 GG S PT or equivalent in Philips/Havells/Wipro make complete all as specified . | 156 | Each | 5,900 ₹9,20,400 Lowest | 9,900 ₹15,44,400 |
| 5.00 | Supply & fixing of LED TRI colour light 4mtr Column with die-cast aluminium top with cylindrical opal polycarbonate diffuser deigned for rugged outdoor usage & IP 65 protection, with inbuilt driver & surge protection (int 4kv & ext 10 kv) Polyurethane finish & maintenance output of 50000 burning hours , Lumin output of 5000 lumens complete with all nuts & bolts complete all as specified and directed by Engr-in-Charge.
Make : Bajaj CAT Part No KOLUX 50W TRI4.0M 100BN. | 10 | Each | 25,000 ₹2,50,000 | 1,000 ₹10,000 Lowest |
| 6.00 | Supply and fixing in replacement LT 3phase Junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 250 x 150 x 100mm (internal) comprising 10 Amps SP MCB, 3 Phase and Neutral incoming cable, 3 Phase and Neutral outgoing cable and single Phase & Neutral connection for light fitting 01 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs incl fixing arrangements including Wiring from junction box to Street Light fitting alongwith with 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC conduit complete all as specified and directed by Engr-in-Charge. | 72 | Each | 1,080 ₹77,760 | 600 ₹43,200 Lowest |
| 7.00 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- | 1 | Each | 1,35,000 ₹1,35,000 | 1,00,000 ₹1,00,000 Lowest |
| 7.01a) Aluminium bus bar 400 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set (b) Incoming MCCB 250A Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos. Location: Middle of the Polo ground(Near SMC) (c) Outgoing MCCB 160 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -1 Nos (d) Outgoing MCCB 100 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -2 Nos (e) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 16 KA, with double break contacts with spreader and phase barrier complete all as directed. - 2 Nos (f) Outgoing MCB 32 Amps 4 pole 415 Volts AC with thermal complete all as directed. -2 Nos (g) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. (h) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No (j) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder-01 set of three. (k) CT Coils of suitable ratio-01 Set. | |||||
| 7.02(l) Single dial time switch, 65A TP contactor for the automatic switching of luminaries, power tool control with 2 No. 65A contactors and raise lower push button, Incoming 35 sq. mm and out going 25 sq. mm 4 core terminals. - 02 Sets Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu. | |||||
| 8.00 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- | 4 | Each | 82,000 ₹3,28,000 | 65,000 ₹2,60,000 Lowest |
Tender Value
₹92.3 L
EMD Value
₹1.6 L
Closing Date
3 Jan 2026, 6:00 pmClosed
HQ CWE AF Jammu
HQ CWE (AF) Jammu Air Force Station Jammu
CA NO CWEAFJ-43/2025-26 SPECIAL REPAIRS TO CERTAIN EM INFRASTRUCTURE AT AF STATION JAMMU UNDER GE (AF) JAMMU
2025_MES_743367_1
CA NO CWEAFJ-43/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAMMU
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹1,000
GE AF Jammu
₹1.6 L
Yes
20 May 2026
6 Dec 2025
5 Jan 2026
6 Dec 2025
3 Jan 2026
27 Dec 2025
Supply & fixing in replacement of decorative Circular, aesthetically designed LED Post Top light, 45 watt 3000K, 50000 Burning hours of maintenance output & 4500 lumens output & CRI>80, IK 10 with optical grade PC diffuser,Pressure die cost aluminium single body and IP66 , anti corrosive epoxy powder coated, the dia of the light suitable for top of the pole dia 60mm complete all as specified and directed.Before placing the order the sample piece along with above quoted pole to be approved by GE. Some lights shall be laid at new place the credit of it will not be catered in Sch of Credit. Make : Bajaj CAT Part No BL ARCHNER PRO NX 45W 3K C3 S / Havells CAT Part No.RINKPT45WLED757PSYMTOPC or equivalent in Philips/Wipro
Supply, fixing and erection in replacement of 4 mtr decorative Pole with decorative double Arm bracket suitable for 45W Post top as per attached drawing/image, aesthetically designed Jet black(RAL 9005) painted, galvaninsed (>35 microns)pole in different cross section with golden yellow colour decorative ring & joint reducer embellishment of aluminium die casting including base plate of size 250x250x10mm thick, (as per manufacture approved Drg) M16 x450mm foundation and nuts & bolts along with template. The external surface of the pole should be finished by single layer primer and double layer of anti-corrosive polyurethane paint (>=50 microns). The pole should be 3mm thick, min dia meters at the bottom is 114mm and3mm thick at the top is 60mm suitable for 45-watt LED Post top light decorative circular design, decorative 10 sqmm rod designed versatile brackets and Double Arm brackets and including all fixtures, accessories complete all as specified and directed. Flushed type Window/ door opening along with 6A MCB SP and 4-way 25sqmm cable connector block 32A with locking arrangement at 600 mm above base plate. Inspection will be done by Engr in Charge before dispatch along with test report. Before placing the order the sample piece to be approved by GE. Some Pole shall be laid at new place the credit of it will not be catered in Sch of Credit. Make : Bajaj CAT Part No BJPL 06 4M ECO POLE WITH DA BRACKET (TOP Dia 60MM) or equivalent in Philips/Havells/Wipro
Supply & fixing of decorative aesthetically designed LED luminaire Post Top light, 45 watt 3000K , With 50000 Hurning hours of maintenance output & 4950 lumens output & CRI>70, IK 08 with aluminium housing & Al heat sink and optical grade UV resistant PC diffuser,IP 66 with powder coated. The dia of the light suitable for top (48mm)of the double arm bracket as above complete all as specified and directed. Inspection will be done at the Factory premises before dispatch along with test report. Before placing the order the sample piece along with above quoted decorative double Arm bracket to be completed and approved by GE . Make : Bajaj CAT Part No BOR NX 45W 30K DO C3 GG S PT or equivalent in Philips/Havells/Wipro make complete all as specified .
Supply & fixing of LED TRI colour light 4mtr Column with die-cast aluminium top with cylindrical opal polycarbonate diffuser deigned for rugged outdoor usage & IP 65 protection, with inbuilt driver & surge protection (int 4kv & ext 10 kv) Polyurethane finish & maintenance output of 50000 burning hours , Lumin output of 5000 lumens complete with all nuts & bolts complete all as specified and directed by Engr-in-Charge. Make : Bajaj CAT Part No BLSLC 50W LED TRI 4M or equivalent in CG/Philips.
Supply and fixing in replacement LT 3phase Junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 250 x 150 x 100mm (internal) comprising 10 Amps SP MCB, 3 Phase and Neutral incoming cable, 3 Phase and Neutral outgoing cable and single Phase & Neutral connection for light fitting 01 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs incl fixing arrangements including Wiring from junction box to Street Light fitting alongwith with 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC conduit complete all as specified and directed by Engr-in-Charge.
Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body
at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
(l) Single dial time switch, 65A TP contactor for the automatic switching of luminaries, power tool control with 2 No. 65A contactors and raise lower push button, Incoming 35 sq. mm and out going 25 sq. mm 4 core terminals. - 02 Sets Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu.
Supply & fixing GI tubing light grade 80 mm bore on poles, under floors, road crossing etc complete all as specified and directed by Eng-in-Charge
Supply & fixing GI tubing light grade 50 mm bore on poles, under floors, road crossing etc all as reqd at site complete all as specified and directed by Eng-in-Charge
(l) Single dial time switch, 65A TP contactor for the automatic switching of luminaries, power tool control with 2 No. 65A contactors and raise lower push button, Incoming 35 sq. mm and out going 25 sq. mm 4 core terminals. - 02 Sets Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu.
Supply & fixing Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistranded and one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cable and one run of PVC conduit shall be measured as one length.)
M & L in replacement of out door aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator weather and vermin proof with IP 54 protection, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer type ,both side openable, from front side & back having, locking arrangement on both sides,mounted over 50x50x6 mm angle iron stand at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground / floor mounted duly grouted in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) factory made duly powder coated including MCCB 200Amp 36KA four pole x 01 Nos as a Incomer all as directed by Engr-In-Charge.
Supply and fixing for earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to GI strip of size 32X6mm as earthing lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown on Electrical Plate No 3 of SSR Part-I 2009, connected to earthing test point all as specified or indicated including testing on completion. The quoted unit rate shall include the following elements as given below :- (a) Earth electrode as mentioned above (b) Main earthing lead of 32X6 mm GI strip from earth electrode to test point up to 7.5 mtrs. (c) Connecting earthing lead and electrode all as specified and testing complete. (d) Adequate quantity of charcoal and salt (e) GI protection pipe of 40 mm dia light grade of length not less than 5.00 mtrs. (f) Necessary excavation, earth work and PCC pit , angle iron 40x40x6mm frame including RCC cover.
Supply, installation, testing and commissioning of split type AC 1.5 ton capacity 5 star rating with Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart complete, suitable for operation on electric driven single phase 230 volt AC 50 c/s and as per I.S. specification complete all as specified and directed. (a) One no cooling unit of 1.5 ton capacity wall mounting type(Copper Tubes) complete. (b) One condensing unit (Copper Tubes) of 1.5 ton capacity complete. (c) PVC pipe for draining out the condensated water (Qty asper the Site requirement) shall be included as quoted rates (d) Additional quantities of refrigerant if required at site shall be charged by the contractor without any extra cost. (e) Quantity of copper tube as per site requirement coverd with cable tray for complete the job shall be included in the quoted rate. (f) Condensing unit shall be installed with stand suitable place of the building as per instrutions of Engr in charge. Old UNSV BER Acs should be removed from existing site and same handover to MES store.
Exacavation for cables loops near the poles LT Panels/transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleeves complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of on load change over 315 Amp 4 pole complete with with Sheet metal encloser incl operating handle and dismantling/connection of existing cables complete as specified and directed by Engineer-in-Charge.
S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 95 sqmm complete all as specified and directed by Engr-in-Charge.
S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to185 sqmm complete all as specified and directed and directed by Engr-in-Charge.
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
Supply & fixing in replacement outdoor type tiranga LED Rope light suitable for 9/11 mtr electric PCC/Steel Pole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction box complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of LT UG cables complete all as specified and directed by Engr-in-Charge. Note : The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil all as specified and directed by Engr-in-Charge .
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:4:8 type
D-2 using 40mm graded crushed stone aggregate as in mass concrete in foundation of poles complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:3:6 type C-1using 20mm graded crushed stone aggregate as in mass concrete in foundation of stays complete all as specified and directed by Engr-in-Charge.
Supply and laying GI steel tubing, 100 mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed by Engr-in-Charge.
Labour for drilling hole under the road with the help of drilling machine without damaging the road horizontally for road crossing in and including HDPE pipe 160mm dia,SDR 13.6 (8Kg/SQCM) 145.04 PSI pressure pipe for cable protection complete all as specified and directed by Engr-in-Charge. Note : Driling of hole under the road 2 to 3 mtr depth and Minimum one slot length 5mtr before drilling signal cable clearance should be received from signal Unit. During the drilling any type of cable damage, the same shall be repaired by contractor without any extra cost.
S&F for capacity luminaires 500 watt LED, CCT 5665±355K with suitable bracket and nut bolt of new Flood light IP 66, pressure die-cast aluminium housing, Luminare efficacy 120LPW, 50000 Burning Hrs, THD <10%, Input Voltage 140-270 Volts, PF ≥0.95,LED driver current > 850 mA (Potted Driver),10 KV external Surge Voltage Protection, Internal surge protection 4 Kv,toughned glass cover with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge.
Supply & fixing for single core PVC insulated unsheathed cable copper conductor of size 2.5 sqmm multistranded drawing in non-metalic PVC rigid conduit complete all as specified and directed by Engr-in-Charge. Note : PVC Conduit will be measured and paid seperatly as relevent item.
Supply and fixing for rigid non-metallic PVC conduit 25mm dia (Heavy duty) in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed by Engr-in-Charge.
Supply and Fixing for MCB SPN 40 Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed by Engr-in-Charge.
Supply and Fixing for MCB Single Pole Neutral 16/25 Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed by Engr-in-Charge.
Material & Labour for brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), including dismantling of unserviceable brick work complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth on walls in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge.
S&F for two core 2.5 Sqmm PVC Copper cable with an inner sheathing of PVC tape and over all PVC Sheathed insulated multi stranded conductor 1100 volts grade complete all as specified and directed by Engr-in-Charge.
S & F for cable route indicator made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggrregate) block of suitable size and neccessary earth work and excavation complete all as specified and directed by Engr-in-Charge.
Material and Labour for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work complete all as specified and directed by Engr-in-Charge.
Description all as per srl item No 39 above but except interlocking cement concrete tiles, (Any thickness/size) (old interlocking tiles obtained from srl items No 38, complete all as specified and directed by Engr-in-Charge.
Dismantling of interlocking cement concrete (any thickness/size), on floor fixed in cement mortar in single layer complete all as specified and directed by Engr-in-Charge.
M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 60mm thickness , M-35 grade, with grey cement and pigment complete all as specified and directed by Engr-in-Charge.
M & L for 25 mm thick sand fillimg under floor/interlocking tiles etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) and disposing the rubbish to a distance exceeding complete all as specified and directed by Engr-in-Charge.
Supply & Fixing for PVC insulated sheathed service wire twin core 10 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one.
Supply & Fixing for PVC insulated sheathed service wire twin core 16 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one.
Supply and Fixing for in replacement of MCCB 350 Amps 4 pole 36 KA with adjustable thermal and fixed magnetic setting, complete all as specified and directed.
Supply & fixing in replacement of integral decorative LED Bollards 9w 5700K in cylindrical shape unique design, with opal PC diffuser and IP66 protection min ht 1mtr complete with all fixing accessories complete all as specified and directed. Make : Bajaj CAT Part No BGBOL 1000 9w LED WH or equivalent in CG/Havells/Philips.
Supply and fixing for replacement thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Nutral outgoing cable and single Phase & nutral connection for light fitting with aluminiuam bus bar of 25 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified and directed by Engr-in-Charge.
M & L for industrial type metal socket enclosure with 240 volt MCB 20 Amps, with metal plug top complete all as specified by Engr-in-Charge, incl taking down old unserviceable one.
Supply and fixing OEM make 3phase Streetlight control panel max load capacity 12KW, incl all vital componants i.e 65A TP Contactor,63A MCB TPN and digital 24hrs switch etc. The panel should conforms to IS/IEC 60947-4-1 with Protection Degree IP- 54, making it suitable for outdoor installation. It should have extended wide band coil & FRLS (Fire retardant low smoke) internal wiring. In-built Short-Circuit Protection should be provided and complies with Class H Insulation complete all as specified and directed by Engr-in-Charge.
Supply , laying , testing & Commissioning UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm, 3.5 core, some cable shell be laid at new place with Suitable thimbles complete all as specified and directed by Engr-in-Charge
Description all as per serial item No 52 here-in-before but of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 95 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 16 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 here-in-before but of size 10 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 52 item No 50 here-in-before but of size 10 Sqmm 2 core complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 4 Sq mm FRLS (Nominal area) drawn through existing PVC conduit concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provi
sion of pressed steel terminal box powder coated of suitable size with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) for AC complete complete all as specified and directed by Engr-in-Charge. Note : Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-55 (11.0 mtr long) erecting in position all as specified and directed by Engr-in-Charge. Note : Excavation Earth work and foundation will be measured and paid seperately under relevent items.
Supply and test only Voltage stabilizer (Copper wound) for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 9% and of capacity 5 KVA wall mounted type having digital LED display and intelligent time delay relay, over load protection and high/low voltage cut off relay Make:-V Guard/Blue star/Microtek/Volina
Supply & fixing for replacement of SPN 4way DB double door complete with bracket and common earth terminal complete all as specified and directed by Engr-in-Charge.
Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i,e. all type of joints, sockets,elbows,bends and end caps etc, of size 50mm outer dia and 38mm inner dia complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of split type AC 2.0 ton capacity, 5 star rating with Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart complete, suitable for operation on electric driven single phase 230 volt AC 50 c/s and as per I.S. specification comprising the following complete all as specified and directed. (a) One no cooling unit of 1.5 ton capacity wall mounting type(Copper Tubes) complete. (b) One condensing unit (Copper Tubes) of 1.5 ton capacity complete. (c) PVC pipe for draining out the condensated water (Qty asper the Site requirement) shall be included as quoted rates (d) Additional quantities of refrigerant if required at site shall be charged by the contractor without any extra cost. (e) Quantity of copper tube as per site requirement coverd with cable tray for complete the job shall be included in the quoted rate. (f) Condensing unit shall be installed with stand suitable place of the building as per instrutions of Engr in charge. Old UNSV BER Acs should be removed from existing site and same handover to MES store.
Description all as per serial item No 62 but of size 77mm outer dia and 76mm inner dia complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 62 but of size 90mm outer dia and 63mm inner dia complete all as specified and directed by Engr-in-Charge.
Supply & fixing for multipurpose LED Spike light using COB LED as light source light, 5 watt die cost aluminium body and IP66 with corrosion-resistant finishes, powder coat paint ,suitable for Column lighting/Tree up lighting/Statue accentuation etc incl all fixing accessories complete all as specified and directed by Engr-in-Charge.
Supply and fixing for air conditioner drain cover kit size of 4x2" (full set) containing (AC socket,Basic duct pipe, connector,diversion elbow,wall hole cover,Flexible duct pipe, Vertical elbow T-Joint, wall cap,Bridge Joint, Exit cover, foldable pipe) complete all as specified and directed by Engr-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_832385.xls
BOQ • 16.12 MB
43TENDERDOC.pdf
Tender Documents • 1.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .