Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.8 L+₹1.1 L (6.81%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance L2 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ MAINT AND DAY TO DAY MISC ELECT WORKS AT MH AREA AND AMC UNITS UNDER GE (EAST) JALANDHAR CANTT
2023_MES_605532_1
GE/JULL/ET-25/2023-24
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹54,000
Yes
9 Aug 2023
24 Jun 2023
31 Jul 2023
24 Jun 2023
22 Jul 2023
10 Jul 2023
Amount
Attending day to day complaints of no power supply of internal electric system in light circuit or power circuit due to burning/disconnecting of any wire i.e. neutral/ phase, loose connection at switch, socket, MCB and tripping of MCB complete incl diagnosing, rectification of fault, any petty repair required to restore the electric supply for checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws in switches, sockets, switch board, ceiling fans/ exhaust fans etc., required to make the circuit functional during 0900 Hrs to 1700 Hrs by deploying electrician alongwith helper including necessary tools complete all as specified and directed. Notes:- (a) Repairs/ faults in any two circuit upto 8 points/ one DB shall be considered as one complaint (one measuring unit) even if repair is involved in more than one light point or fitting. (b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed electrician & helper will carry all T&P, functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor. (e) Contractor shall be responsible for collection of all ON LINE, off line/ telephonic complaints in morning at 0900 Hrs and handing over the same to complaint cell after rectification duly signed by user with details of stores fixed after attending/ completion of the job on the same day.
Supply and fixing constant current LED driver suitable for surface/recess mounted LED panel 2 ft x 2 ft, any wattage, any make including taking down existing driver complete all as specified and directed
Supply and fixing constant current LED driver suitable for surface/recess mounted post top lantern upto 25/40 watt including taking down existing driver complete all as specified and directed
Supply and fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, one way including taking down existing switch complete all as specified and directed.
Supply and fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified and directed.
Supply and fixing switch piano flush type, 15 Amps, 240 Volt AC single pole, one way including taking down existing switch complete all as specified and directed.
Supply and fixing socket out let 5 Amp, 5 pin flush type including taking down existing socket complete all as specified and directed.
Supply and fixing socket outlet multipurpose 2 in 1, 3 pin, 5 & 15 Amps, flush type including taking down existing socket complete all as specified and directed.
Supply and fixing bell push switch flush type 5 Amps, SP, 240 volts including taking down existing switch complete all as specified and directed.
Supply and fixing lamp holder insulated body with back plate suitable for batten fittings including taking down existing holder complete all as specified and directed.
Supply and fixing ceiling rose surface type bakelite 65 x 50mm three terminal including taking down existing ceiling rose complete all as specified and directed.
Supply and fixing electronic step type 5 speed ceiling fan regulator, single phase, 1 module including taking down existing regulator complete all as specified and directed.
Supply and fixing electronic step type 5 speed ceiling fan regulator, single phase, 2 module including taking down existing regulator complete all as specified and directed.
Supply and fixing bell electric AC (Ding Dong) 240 volts SP including taking down existing bell complete all as specified and directed.
Supply and fixing white modular switch 1 way 6 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed.
Supply and fixing white modular switch two way 6 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed.
Supply and fixing in replacement white modular switch 1 way 16 Amp, 250 volt 1 module complete all as specified and directed.
Supply and fixing white modular bell push switch 6 Amp, 250 volt 1 module including taking down existing bell push complete all as specified and directed.
Supply and fixing white modular socket 6 Amp, 250 V AC 2 in1 socket with shutter combined two module including taking down existing socket complete all as specified and directed.
Supply and fixing white modular socket 6/16 Amp, 250 V AC twin socket combined two module including taking down existing socket complete all as specified and directed.
Supply and fixing white modular fan regulator , 250 V AC step type 5 steps two module including taking down existing regulator complete all as specified and directed.
Supply and fixing white modular blanking plate one module including taking down existing blanking plate complete all as specified and directed.
Supply and fixing mini MCB SP 20 Amps, 240V with rupturing capacity 10 KA, C-Curve including taking down existing MCB SP complete all as specified and directed.
Supply and fixing MCB SP 6 Amps to 32 Amps, 240V with rupturing capacity 10 KA, C-Curve including taking down existing MCB SP complete all as specified and directed.
Supply and fixing MCB SPN 6 Amp to 32 Amps, 240V with rupturing capacity 10 KA, C-Curve including taking down existing MCB SPN complete all as specified and directed.
Supply and fixing MCB SPN 40 Amps, 240V with rupturing capacity 10 KA, C-Curve including taking down existing MCB SPN complete all as specified and directed.
Supply and fixing 415V, 10KA, C-Curve miniature circuit breaker (MCB) of triple poles and current carrying capacity 32Amps in the DB including taking down complete all as specified and directed.
Supply and fixing 415V, 10KA, C-Curve miniature circuit breaker (MCB) of triple poles neutral and current carrying capacity 32Amps in the DB including taking down complete all as specified and directed.
Supply and fixing 415V, 10KA, C-Curve miniature circuit breaker (MCB) of triple poles neutral and current carrying capacity 63Amps in the DB including taking down existing MCB complete all as specified and directed.
Supply and fixing in existing DB/panel MCCB 63 Amps, 3 pole 16 KA with extended terminals, phase separators with spacers including taking down existing MCCB complete all as specified and directed.
Supply and fixing in existing DB/panel MCCB 100 Amps, 3 pole 16 KA with extended terminals, phase separators with spacers including taking down existing MCCB complete all as specified and directed.
Supply and fixing in existing DB/panel MCCB 160 Amps, 4 pole 25 KA with extended terminals, phase separators with spacers including taking down existing MCCB complete all as specified and directed.
Supply and fixing in existing DB/panel MCCB 200 Amps, 4 pole 25 KA with extended terminals, phase separators with spacers including taking down existing MCCB complete all as specified and directed.
Supply and fixing fan capacitor 2.5/ 3.15 MFD including taking down existing complete all as specified and directed.
Supply and fixing fan mounting clamp with rubber reel for ceiling fan including nut & bolt and cotter pin including taking down out unserviceable clamp complete all as specified and directed
Supply and fixing flexible cord of size 1 sqmm two core including taking down existing cable complete all as specified and directed.
Supply and fixing flexible cord of size 0.75 sqmm two core including taking down existing cable complete all as specified and directed.
Supply and fixing flexible cord of size 1.5 sqmm three core including taking down existing cable complete all as specified and directed.
Supply and fixing copper wire FRLS PVC insulated unsheathed 1.5 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing copper wire FRLS PVC insulated unsheathed 2.5 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing copper wire FRLS PVC insulated unsheathed 4.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing copper wire FRLS PVC insulated unsheathed 6.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing copper wire FRLS PVC insulated unsheathed 10.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing copper wire FRLS PVC insulated unsheathed 16.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed. Note for Srl item No. 36.00 to 44.00 : Rate of conduit and cutting chases if required, will be paid separately under respective item as per site requirement.
Supply and fixing of metal clad industrial plug 20 Amps, 250 V, 2 pole with earth and metal top plug suitable for geyser/ AC including taking down existing plug complete all as specified & directed.
Supply and fixing plastic surface mounting box of 3 module including taking down existing mounting box complete all as specified and directed.
Supply and fixing plastic surface mounting box of 6 module including taking down existing mounting box complete all as specified and directed.
Supply and fixing modular cover plate (WHITE) with frame 3 module including taking down existing cover plate complete all as specified and directed.
Supply and fixing modular cover plate (WHITE) with frame 6 module including taking down existing cover plate complete all as specified and directed.
Supply and fixing B-22 energy saving LED bulb 12 watt, 230V, 6500K including taking down existing LED bulg complete all as specified and directed.
Supply and fixing in repairs energy saving ultra bright LED polycarbonate tube rod 20W suited for installation in existing T8 fitting with G13 lamp holders, lumen efficacy 110 lumen/ watt, complete all as specified and directed.
Supply and fixing in replacement wall mounted LED light fitting 4', 20W, lumen efficacy > 120 lumen/watt (min), THD<15%, power factor>0.95 in extruded aluminium housing with polycarbonate diffuser and integrated electronic driver with short circuit and surge protection complete all as specified and directed.
Supply and fixing in replacement wall mounted LED light fitting 2', 10W, lumen efficacy > 100 lumen/watt (min), THD<15%, power factor>0.95 in extruded aluminium housing with polycarbonate diffuser and integrated electronic driver with short circuit and surge protection complete all as specified and directed.
Supply and fixing in replacement energy saving recess mounting LED luminaire, suitable for false ceiling of size 60cm x 60xm with CRCA housing, 34/36W, IP-20, lumen efficacy > 100 lumen/watt (min), THD<15%, power factor>0.95 with high efficiency LED electronic driver with short circuit and surge protection, operative on 140-270V, AC supply, complete all as specified and directed
Supply and fixing in replacement energy saving surface mounting LED luminaire of size 60cm x 60xm with CRCA housing, 34/36W, IP-20, lumen efficacy > 100 lumen/watt (min), THD<15%, power factor>0.95 with high efficiency LED electronic driver with short circuit and surge protection, operative on 140-270V, AC supply, complete all as specified and directed. Notes for Srl item No. 2.00 to 55.00 (a) The above mentioned items will be replaced based on day to day complaints and no extra cost will payable for attending complaints. Contractor will quote the rate accordingly. (b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed electrician & helper will carry all T&P, live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor. (e) Contractor shall be responsible for collection of all On-line, Off-line/ Telephonic complaints and handing over the same to complaint cell after rectification duly signed by user with details of stores fixed after attending/ completion of the job on the same day. (f) Contractor shall handover these items within 15 days to concerned JE-in-Charge which will be issued for fixing on the basis of day to day complaints. The recovery of Rs 1500 per day shall be levied in case of default.
Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawl plug, screw etc including removing unserviceable material fromsite for taking credit and serviceable material to store for re-fixing at site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm, FRLS PVC insulated but unsheathed, multi stranded copper conductor single core FRLS cable, IS-694 marked, drawn through new surface/concealed conduit with and including replacement of suitable module modular metal flush mounting box with white cover plate with frame, brass screws and cup washers including 1.5 Sqmm multi stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for one light point/fan/bell controlled by one switch SP one way.
All as per srl item No. 57.00 above but for one socket outlet 5 Amps on independent board.
All as per srl item No. 57.00 above but for one socket outlet 5 Amps on same board with other switches.
All as per srl item No. 57.00 here in before but with 2.5 Sqmm (nominal area) FRLS cable for one 3 pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.
Supply and fixing PVC conduit medium grade 20mm dia ISI marked including saddles/ clamps and junction boxs including taking down existing conduit complete all as specified and directed.
Supply and fixing PVC conduit medium grade 25mm dia ISI marked including saddles/ clamps and junction boxs including taking down existing conduit complete all as specified and directed.
Supply and fixing PVC casing caping 20/12mm ISI marked including taking down existing conduit complete all as specified and directed.
Supply and fixing PVC casing caping 25/16mm ISI marked including taking down existing conduit complete all as specified and directed.
Material and labour for cutting chases, cement/ concrete/ brick/ tile surface, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sun shades, shelves, lintels etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc 10cm girth in brick walls complete all as specified and directed.
Material and labour for submain wiring with PVC insulated cable copper conductor FRLS two single core 2.5 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 2.5 Sqmm, one run of cable 2.5 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour for submain wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 4 Sqmm, one run of cable 4 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour for submain wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 6 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 6 Sqmm, one run of cable 6 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour for submain wiring with PVC insulated cable copper conductor FRLS two single core 10 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 10 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 10 Sqmm, one run of cable 10 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour for submain wiring with PVC insulated cable copper conductor FRLS two single core 16 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 16 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 16 Sqmm, one run of cable 16 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Taking down carefully geyser of capacity 25 ltrs and remove outer cover complete with insulation, supply and fix outer cover complete as per existing pattern along with suitable type insulation complete all as specified and directed
Taking down carefully geyser of capacity 25 ltrs and remove inner tank with assembly, thermostat and heating element, supply and fix SS inner tank along with suitable type thermostat and heating element 2 KW complete all as specified and directed
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, SPN 12 ways 240 V, with copper bus bar, double door, epoxy/ powder coated inside and outside with neutral and earth connection bar prewired including taking down complete all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, SPN 8 ways 240 V, with copper bus bar, double door, epoxy/ powder coated inside and outside with neutral and earth connection bar prewired including taking down complete all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, SPN 4 ways 240 V, with copper bus bar, double door, epoxy/ powder coated inside and outside with neutral and earth connection bar prewired including taking down complete all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, SPN 2 ways 240 V, with copper bus bar, double door, epoxy/ powder coated inside and outside with neutral and earth connection bar prewired including taking down complete all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, TPN 4 ways 415 V, with 200 Amps rated bus bar, double door, epoxy/ powder coated inside and outside with neutral and earth connection bar prewired including taking down complete all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, TPN 8 ways 415 V, with 200 Amps rated bus bar, double door, epoxy/ powder coated inside and outside with neutral and earth connection bar prewired including taking down complete all as specified and directed.
Supply and fixing distribution board iron clad vertical type, double door with IP-43 IK -09 Protection suitable for MCCB TP as incomer and MCB SP/ TP as outgoing 415 volts 3 phase 50 C/s 4 way , complete with appropriate size copper bus bar and neutral and earth link complete with one MCCB TP 415 volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface including taking down all as specified and directed. Note : Rates of MCCB is deemed to be included in quoted rate.
Supply and fixing distribution board iron clad, vertical type double door with IP-43 IK -09 Protection suitable for MCCB TP as incomer and MCB SP as outgoing 415 volts 3 phase 50 C/s 8 way , complete with appropriate size copper bus bar and neutral and earth link complete with one MCCB TP 415 volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface including taking down all as specified and directed. Note : Rates of MCCB is deemed to be included in quoted rate
Supply and fixing rod for hanging ceiling fan 45 cm long including 02 Nos nuts bolts and washers with lock pins including taking down complete all as specified and directed.
Supply and fixing rod for hanging ceiling fan 60 cm long including 02 Nos nuts bolts and washers with lock pins including taking down complete all as specified and directed.
Material and labour in replacement for earthing complete with & including copper earth plate of size 600 x 600 x 3.15mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to copper earth wire 20x3mm dia connected soldered and riveted to earth plate by means of nuts, bolts , check nuts & washers of galvanized iron or steel all as Shown in electrical plate No. 3 of MES Schedule (Part- I) and connected to panel board, all as specified and testing on completion including provision of earth wire protected by 25mm dia light grade GI pipe upto 7.5 meter from electrode to earth terminal point feeder pillar box including provision of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate GI light grade watering pipe of 20mm dia with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC (1:3:6) type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete 1:2:4 type B-0 reinforced with & including 8mm dia mild steel TMT bar @ 100mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified & shown on drawings & directed. Notes: - (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Material and labour in replacement for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire 4mm dia connected soldered and riveted to earth plate by means of nuts, bolts , check nuts & washers of galvanized iron or steel all as Shown in electrical plate No. 3 of MES Schedule (Part- I) and connected to panel board, all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe upto 7.5 meter from electrode to test point and aluminium strip 25 x 3.15mm from test point to equipment including provision of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate GI light grade watering pipe of 20mm dia with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC (1:3:6) type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete 1:2:4 type B-0 reinforced with & including 8mm dia mild steel TMT bar @ 100mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified & shown on drawings & directed. Notes: - (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Material and labour in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Dismantling of ceiling fan upto 1200/1400mm sweep of any make/ model/ sweep, removing the burnt out winding wires, rewinding with copper winding wire of superior quality and insulation materials overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, capacitor, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed
Dismantling of exhaust fan upto 250-300mm sweep of any make/ model/ sweep, removing the burnt out winding wires, rewinding with copper winding wire of superior quality and insulation materials overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, capacitor, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed
Dismantling of exhaust fan upto 380-450mm sweep of any make/ model/ sweep, removing the burnt out winding wires, rewinding with copper winding wire of superior quality and insulation materials overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, capacitor, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed
Material and labour for painting of ceiling fans/ exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed
Supply, laying, testing and commissioning in replacement of service wire PVC insulated, electric cables, (heavy duty) 1100 volts grade with aluminium conductor of size 2.5 Sqmm 2 Core complete all as specified and directed
All as per Srl Item No. 90.00 above here-in-before but 4.0 Sqmm 2 Core
SUNRISE ENGINEERS AND CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .