Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.0 LAccepted-AOC | 1 | Accepted-AOC BEING L-1 | |
| 2 | 2₹18.9 L+₹2.9 L (18.0%)Rejected-Finance SHASTRI NAGAR DINOD ROAD NEAR SAINI STUDIO BRIJWASI COLONY BHIWANI HARYANA | BHIWANI | BHIWANI | HARYANA | 2 | Rejected-Finance BEING L-2 | |
| 3 | Rejected-Technical | - | Rejected-Technical inadequate |
Tender Value
₹16.5 L
EMD Value
₹32,980
Closing Date
8 May 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Registrar
Indira Gandhi University, Meerpur, Rewari
Maintenance of S.V.P. Block at IGU, Meerpur, Rewari
2023_HRY_261597_1
IGU/Engg/2023/002
Open Tender
Civil Works
Tender
120 days
Indira Gandhi University, Meerpur, Rewari
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹32,980
Yes
24 Jul 2023
28 Feb 2023
10 May 2023
28 Feb 2023
8 May 2023
28 Feb 2023
Amount
Pointing on tile brick work with cement mortar 1:3. 11.26.1 Flush ruled/Struck or weathered pointing.
Waterproofing Treatment of Terrace with fiber reinforced elastomeric liquid applied waterproofing membrane: a) Preparation of Surface, filling of cracks with Smart Care Hybrid PU Sealant wherever required. b) Providing and applying Smart Care Damp proof, a fiber reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 liter/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. When the 2nd coat is wet, the Smart Care EPDM tape (at corners and edges) shall be inserted between second and third coat, let the material out from the tapes corner. Same treatment of Smart Care Damp proof shall be continued to the parapet walls to better envelope the whole area. The coating shall be terminated carefully to the other side of the parapet wall. Make: Asian Paints Smart Care
Dismantling tile work in floors and roofs laid in cement mortar i/c stacking material within 50 mtrs. lead 5.43.1 For thickness of tiles 10mm to 25mm
Dismantling old plaster or scrubbing racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
Providing & fixing 1st class ceramic glazed wall tiles confirming to IS:15622 (Thickness to be specified by the manufacturer) of approved make, in all colors, shades except burgundy bottle green, black of any size as approved by E-I-C, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 and jointing with cement slurry @ 3.3 Kg/ per Sqm, i/c pointing in white cement mixed with pigment of matching shade.
Repair to plaster of thickness 12-20mm in patches of area 2.5 Sqm and under, i/c cutting the patch in proper shape, racking out the joints and preparing and plastering the surface of walls complete, i/c disposal of rubbish to the dumping ground, all complete as per the direction of E-I-C. 30.16.2 With cement mortar 1:4 (1 Cement, 4 coarse sand)
P&F granite stone in all shades 15-18mm thickness in skirting/dados, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointing with white cement slurry mixed with pigment to match the shade of Granite i/c labour for fixing cramp pins and dowels etc.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 13.3.1 Profile B 13.3.1.1 Fixing with adjustable lugs with split and tail to each jamb.
Renewing glass panes, with putty and nails wherever necessary i/c racking out the old putty. 30.54.2 Float Glass panes of nominal thickness 5.00mm
Finishing walls with Premium Acrylic Smooth exterior paint with Silicon additives of required shade. 30.38.1 Old work (Two or more coats)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth i/c necessary repairs to scratches etc. complete
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:- 30.28.1 One or more coat on old work
Distempering with 1st quality acrylic distemper (Ready mixed) having VOC content less than 50 grams per liter of approved brand and manufacture to give even shade. 30.25.1 Old work (One or more coat)
10cm thick (Average) mud phuska of damped brick earth on roofs laid to slope consolidated and plastered with 25mm thick mud mortar mixed with bhusa @ 35/- kg. per cum of earth and covered with flat tile bricks, grouted with cement mortar 1:3 mixed with 2% of integral water proofing compound by weight of cement and finished neat:- 9.11.1 With common brunt clay non-modular brick tiles of class designation-10.
Pawan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .