Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC LOWEST QUOTED HENCE ADMITTED | |
| 2 | L2₹20.7 L+₹1.8 L (9.61%)Rejected-AOC SAI VARENYA PARK VIEW FLAT NO 110 GROUND FLOOR 9TH MAIN 6TH CROSS TURAHALLI BANGALORE 560 061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L2 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 3 | L3₹24.8 L+₹5.9 L (31.4%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 4 | L4₹27.3 L+₹8.4 L (44.4%)Rejected-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L4 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹47,000
Closing Date
29 May 2023, 6:00 pmClosed
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
REPAIR MAINTENANCE OF DG SETS AT VARIOUS LOCATION UNDER GE (AF) MARATHAHALLI
2023_MES_581107_1
87515CWEAFNMAR
Open Tender
Civil Works
Item Rate
360 days
GE (AF) MARATHAHALLI
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (AF) MARATHAHALLI
₹47,000
Yes
16 Jun 2023
15 Feb 2023
5 Jun 2023
15 Feb 2023
29 May 2023
11 May 2023
16 Feb 2023 - 24 Feb 2023
Amount
Inspection, maintenance and servicing of 320KVA DG set including Alternator excluding AMF panel installed at ASTE MT Yard - for routine check up [once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge.
Inspection, maintenance and servicing 250/275 KVA DG set including Alternator excluding AMF panel installed at ASTE HANGER for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 200 KVA DG set including Alternator excluding AMF panel installed at ASTE TP SCHOOL for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions /OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 125 KVA DG set including Alternator excluding AMF panel installed at ASTE Power house for routine check up [once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions / OEM all as specified and directed by Engr-in-Charge. Make: Cummins
Inspection, maintenance and servicing of 750 KVA DG set including Alternator excluding AMF panel installed at SDI Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Cummins
Inspection, maintenance and servicing 320 KVA DG set including Alternator excluding AMF panel installed at SDI Power house - Set No.1 for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Cummins
Inspection, maintenance and servicing 320 KVA DG set including Alternator excluding AMF panel installed at SDI Power house - Set No.2 for routine check up [once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions OEM all as specified and directed by Engr-in-Charge.
Inspection, maintenance and servicing 40 KVA DG set including Alternator excluding AMF panel installed at SDI Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 400 KVA DG set including Alternator excluding AMF panel installed at IAM for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 250 KVA DG set including Alternator excluding AMF panel installed at IAM Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Cummins/ Kirloskar
Inspection, maintenance and servicing 62.5 KVA DG set including Alternator excluding AMF panel installed at IAM Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 43 KVA DG set including Alternator excluding AMF panel installed at IAM Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make: Delmot
Inspection, maintenance and servicing 62.5 KVA DG set including Alternator excluding AMF panel installed at 26 ED Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 63 KVA DG set includingAlternator excluding AMF panel installed at 26 ED Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions /OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 25 KVA DG set including Alternator excluding AMF panel installed at SMC MP CAMP for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by the Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 75 KVA DG set including Alternator excluding AMF panel installed at 26 ED Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions /OEM all as specified and directed by Engr-in-Charge. Make : Standard DG Set - 02 Nos
Inspection, maintenance and servicing 70 KVA DG se including Alternat excluding AMF panel installed at Vishwa Vihar Pump house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 10 KVA DG set including Alternator panels excluding AMF panel installed at STP Vishwa Vihar for routine check up [once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge.
Inspection, maintenance and servicing 125 KVA DG set including Alternator excluding AMF panel installed at Vishwa Vihar Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 25 KVA DG set including Alternator excluding AMF panel installed at SMC MP CAMP for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by the Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 40 KVA DG set including Alternator excluding AMF panel installed at M P camp for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 125 KVA DG set including Alternator excluding AMF panel installed at Akash Vihar Power house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 62.5 KVA DG set including Alternator excluding AMF panel installed at Akash Vihar for routine check up once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 62.5 KVA DG set including Alternator excluding AMF panel installed at Vayu vihar officers mess for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions /OEMall as specified and directed by Engr-in-Charge. Make : Kirloskar
Inspection, maintenance and servicing 82.5 KVA DG set including Alternator of connected excluding AMF panel installed at VayuVihar for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEMall as specified and directed by Engr-in-Charge. Make: Greaves
Inspection, maintenance and servicing 15 KVA DG set Including Alternator including AMF panel installed at VayuVihar Pump house for routine check up [ once in two months /A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturers instructions/OEM all as specified and directed by Engr-in-Charge. Make : Kirloskar
Note:- 'A'Check (Item Nos. 1 to 26). (i) Check Engine oil level and topping up as and when required [Engine oil will be measuered paid separately] (ii) Check Engine Coolant oil level if required topping up.[Coolant oil measured and paid separately] (iii) Check Belts if there is belt slippage adjust or replace. (iv) Check oil bath cleaner oil level. (v) Check Exhaust System for leakage and rectification. (vi) Drain sediment and cleaning from Fuel filter & Fuel Tank. (vii) Check dry type air filter element and clean or replace [ Air filter element shall be measuered paid seperately]. (viii) Check engine alternator coupling and mounting bolts. (ix) Tight all bolts and nuts in Alternator Terminal Box. (x) Check carbon brushes[Brush type] and connections in Alternator. (xi) Check and tight all Electric connections in DC control wiring. (xii) Check all Radiator rubber Hoses. Record oil pressure, water and oil Temp. (xiii) Record RPM, Voltage, AMPS and Hz. (xiv) Check Anti Vibrating Mountings. (xv) Check throttle linkages. (xvi) Check starting battery electrolyte level, specific gravity and topping up if required.
Inspection, maintenance and servicing of DG set 200 KVA installed at ASTE TP SCHOOL including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 125 KVA installed at ASTE POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 250/275 KVA installed at ASTE TP SCHOOL including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 320 KVA installed at ASTE MT AREA including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 750 KVA installed at SDI Power house including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers/OEM instructions including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 320 KVA installed at SDI Power house Set No. 1 including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 320 KVA installed at SDI Power house Set No. 2 including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 40 KVA installed at SDI POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 400 KVA installed at IAM including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 250 KVA installed at IAM POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 43 KVA installed at IAM POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 62.5 KVA installed at IAM POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 62.5 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 63 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 25 KVA installed at 26 ED including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 75 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 70 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions /OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 70 KVA installed at VISHWA VIHAR PUMP HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions /OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 125 KVA installed at VISHWA VIHAR POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions /OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 10 KVA installed at STP VISHWA VIHAR including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 25 KVA installed at SMC MP CAMP including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 40 KVA installed at M P camp including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 125 KVA installed at AKASH VIHAR POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 62.5 KVA installed at Akash Vihar including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 82.5 KVA installed at VAYU VIHAR POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 62.5 KVA installed at VAYU VIHAR OFFICER'S MESS including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions /OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Inspection, maintenance and servicing of DG set 15 KVA installed at VAYU VIHAR PUMP HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
Servicing & Maintenance of AMF panels (Once in two months) pertains to 320 KVA DG SET installed at ASTE MT Area for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 200 KVA DG SET installed at ASTE TP SCHOOL for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 125 KVA DG SET installed at ASTE POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 250/275KVA DG SET installed at ASTE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 750 KVA DG SET installed at SDI POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 320 KVA DG SET installed at SDI Power house Set No. 1 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 320 KVA DG SET installed at SDI Power house Set No. 2 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 40 KVA DG SET installed at SDI for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 400 KVA DG SET installed at IAM POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 250/ 275 KVA DG SET installed at IAM POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at IAM HPHCfor smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 40/43 KVA DG SET installed at M P camp for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 63 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 75 KVA DG SET installed at 26 ED Courier longe for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 70 KVA DG SET installed at 26 ED Storage yard for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. DG Set - 02 Nos Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 125 KVA DG SET installed at VISHWA VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 40/43 KVA DG SET installed at M P camp for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at Akash Vihar for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 125 KVA DG SET installed at AKASH VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 82.5 KVA DG SET installed at VAYU VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at VAYU VIHAR OFFICER'S MES for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
Servicing of Self Starter assembly of 24 volt DC suitable for 320 KVA to 750 KVA by disconnecting from engine and dismantling the same, cleaning all accessories, replace the wornout parts like brushes, bushes, contact plates, jumping leads and seals, rewinding/revarnishing the field coil, armature and reassembling the same, refitting to the engine and testing all as directed by Engr-in-Charge.
Servicing of Self Starter assembly of 24 volt DC suitable for 125 KVA to 250 KVA by disconnecting from engine and dismantling the same cleaning all accessories, replace the wornout parts like brushes, bushes, contact plates, jumping leads and seals, rewinding/revarnishing the field coil, armature and reassembling the same,refitting to the engine and testing all as directed by Engr-in-Charge.
Servicing of Self Starter assembly of 12 volt DC suitable for 10 KVA to 82.5 KVA by disconnecting from engine and dismantling the same cleaning all accessories, replace the wornout parts like brushes, bushes, contact plates, jumping leads and seals, rewinding/revarnishing the field coil, armature and reassembling the same,refitting to the engine and testing all as directed by Engr-in-Charge.
Removing the self starter 24 Volt DC from the engine of 125 KVA to 750 KVA DG sets and taking to work shop for rewinding of armature/field including replacement of brush and bush and refixing the same to the engine and testing all as directed by Engr-in-Charge.
Supply only engine oil XLD 20W40CF. (barrel 200ltrs)Make:Volvoline / IOC
Supply & filling radiator Koolant Classic, Make:Volvoline / IOC (barrel 200ltrs)
Supply only 12 V DC stopping solenoid suitable for 10 to 82.5 KVA DG sets.
Supply only 24 V DC energised Stopping solenoid for 125 to 750 KVA DG sets.
Supply only Water Temp gauge with adapter.
Supply only Oil Temp gauge with adapter.
Supply only Oil pressure guage with pipe.
Supply only Diaphragm Coupling for 40/43.5 KVA DG Sets.
Supply only Diaphragm Coupling for 62.5/63/70/75/82.5 KVA DG Sets.
Supply only Diaphragm Coupling for 125 KVA DG Sets.
Supply only Diaphragm Coupling for 250 to 750 KVA DG Sets.
Supply only AC / DC Timer.
Supply only PLA Relay with Base.
Supply only Volt meter DC.
Supply only Ammeter DC.
Supply only Battery 12 volts 180 AH , 36 months warranty
Supply only Battery 12 volts 150 AH , 36 months warranty
Supply only LED Volt meter
Supply only LED Ammeter
Taking out unserviceable power contactor and Supply and fixing power contactor MCX43 400 Amps 4P suitable for 750 KVA DG Set ,
Supply and fix in repairs Air filter element as per existing make for 750 KVA DG Set installed at SDI AF.
Supply and fix in repairs Air filter element as per existing make for 320/400 KVA DG Set installed at ASTE MT Area.
Supply and fix in repairs Air filter element as per existing make for 250/275 KVA DG Set installed at IAM power house set No. 1
Supply and fix in repairs Air filter element as per existing make for 200 KVA DG Set installed at ASTE TP SCHOOL
Supply and fix in repairs Air filter element as per existing make for 125 KVA DG Set installed at ASTE POWER HOUSE
Supply and fix in repairs Air filter element as per existing make for 82.5 KVA DG Set installed at VAYU VIHAR POWER HOUSE
Supply and fix in repairs Air filter element as per existing make for 75 KVA DG Set installed at 26ED POWER HOUSE
Supply and fix in repairs Air filter element as per existing make for 70 KVA DG Set installed at VISHWA VIHAR POWER HOUSE
Supply and fix in repairs Air filter element as per existing make for 62.5/63 KVA DG Set installed at Akash Vihar.
Supply and fix in repairs Air filter element as per existing make for 40/43 KVA DG Set installed at SDI POWER HOUSE
Supply and fix in repairs Air filter element as per existing make for 25/15/10 KVA DG Set installed at SMC MP CAMP
Supply and Fix Fly Wheel Ring suitable For 125KVA DG Work installed at Akash Vihar MES Pump House complete all as specified and as directed .
Supply and Fix MCCB 40A 4Pole 25Ka Make:HPL installed complete all as specified and as directed .
Supply and Fix Phase Failur Relay VMRD2 240V AC Minilec make installed at ASTE complete all as specified and as directed .
Supply and Fix Mini Contactor 220V installed at ASTE complete all as specified and as directed .
Supply and Fix Contactor 16A suitable for 320KVA DG Work installeda at SDI complete all as specified and as directed .
Servicing of radiator assembly of 750 KVA DG SET installed at SDI POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 320/400 KVA DG SET installed at SDI POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 250/275 KVA DG SET installed at IAM POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 200 KVA DG SET installed at ASTE TP SCHOOL complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 125 KVA DG SET installed at ASTE POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 125 KVA DG SET installed at VISHWA VIHAR POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 82.5 KVA DG SET installed at VAYU VIHAR POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 70/75 KVA DG SET installed at 26 ED POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 62.5/ 63 /40 KVA DG SET installed at 26ED POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Servicing of radiator assembly of 25 KVA DG SET installed at SMC MP CAMP complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.
Supply and fix Contactor MNX 95 3 pole 2NO + 2NC contactor 240V suitable for 750 KVA complete all as specified and as directed
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at SDI, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at IAM, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.
Comprehensive maintenance and servicing of gate barriers of span 7.2 metre installed at 26ED, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at 26ED VIP GATE, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.
Comprehensive maintenance and servicing of Sliding gate electrically operated including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc., installed at SDI (AF) complete for smooth functioning all as specified and as directed by Engr-in-Charge.
Supply and fix Automatic voltage regulator upto 125 KVA complete all as specified and as directed .
Supply and fix Automatic voltage regulator upto 200 KVA to 320 KVA complete all as specified and as directed. Note (For SI Item No. 1 to 134) :- The Contractor has to maintain a MAINTENANCE REGISTER throughout the contract period for every maintenance visits and shall be ensured entry of all the works carried out duly signed by Technician, JE E/M and Engineer-in-charge.
PRANATHI DEVELOPERS
UNIVERSAL ENGINEERING
Lucky Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .