Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹40.1 L+₹1.3 L (3.27%)Rejected-AOC E 30 RAJIV NAGAR BEGAMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORK OF B/R E/M TO CERTAIN BUILDINGS NPC P-32 OF SANJAY VIHAR MD ACCN OF SIGNAL ENCLAVE AND CERTAIN BLDGS OF OFFRS MESS PROVOSIT UNIT AND DAPS UNDER AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI
2021_MES_410196_1
GE/C-75/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹92,000
Yes
6 Mar 2021
6 Jan 2021
3 Feb 2021
6 Jan 2021
1 Feb 2021
20 Jan 2021
6 Jan 2021 - 20 Jan 2021
60 days
Amount
Demolition of cement concrete(reinforced) of any description and in any position not otherwise specifically provided for and including reinforced removal of debris rubbish outside MoD land demolition) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) as in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed by Engineer-in-Charge.
M & L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors finished, surface even and smooth using extra cement, complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar in any description and position, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 05 here-in-before but except bricks complete all as specified and directed by Engineer-in-Charge.
M&L for chipping out, roughening and cleaning spoiled/ loose concrete as in RCC columns, beams, slabs, chajjas, parapets, fins and the like members upto 25 mm avarage thickness, washing with water and allowed to dry including derusting existing reinforcement with approved chemical. Supply and fix Mild Steel square wire mesh 65x65x2mm as strengthening reinforcement, applying anti-rust chemical on new wire mesh and guninting chipped surfaces upto 25mm (average) thick with pressure of 2.5 to 3.00 kg/Sqcm, using one part of OPC 43 grade cement and two parts of Ghaggar sand mixed with approved admixture and achieving an even surface including rendering 15mm thick in CM 1:4 finished even smooth without using extra cement. Work to be carried out in patches for buildings upto 18 meter height. Anti-rusting, adhesive, admixure chemical shall be of apporved make and incorporated as per instruction of the manufacturer for specific application. Note:- The work shall be carried out using scafolding, padding, netting complete all as directed at site including all safety provisions. Cost of the above aspects shall deemed to be included in the quoted rates.
S&F Steel work in tubular trusses including special shape washer etc. complete using ERW or induction butt welded tubes including painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication conforming to IS 1161-1979 grade St-240 complete all as specified and directed by Engineer-in-Charge.
S & F MS framed work such as grills, gratings etc with ends of bars shouldered and or riveted, framed guard bars, barred iron doors, ladders, frame work of water trough, railings,cooler stand and similar work to conforming to Fe -290-0 including making hole in base plate fastner complete all as specified upto double storey height complete all as specified and directed by Engineer-in-Charge..
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe -290 Gde E-165 (Brackets over 10 kg each to be measured under ‘Structural Steel') complete all as specified and directed by Engineer-in-Charge.
S&F Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe -290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
M&L Preparing new or previously untreated steel and iron surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge..
M & L rendering 15 mm thick on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L two coats of cement base paint over a coat of cement primer incl preparation of new plaster surface all as specified Note : Contractor will make his own arrangement for use of scaffolding, trestles, cradles, ladders etc necessary for execution of works upto any height; no extra payment for use of scaffolding, trestles, cradles, ladders etc will be made and colour should match with existing colour of bldg complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of newly plastered surfaces of walls and applying two coats of weather proofing exterior acrylic emulsion paint premier quality on wall surface over one coat of primer from the same manufacturer complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of wall by complete removal of external treatment and applying two coat of cement base paint including scaffolding if required complete all as specified and directed. Note : Contractor will make his own arrangement for use of scaffolding, trestles, cradles, ladders etc necessary for execution of works upto any height; no extra payment for use of scaffolding, trestles, cradles, ladders etc will be made and colour should match with existing colour of bldg complete all as specified and directed by Engineer-in-Charge.
M&L Complete removal of exising old surfaces of wall / ceiling by scrubbing with hard brushing ,brooming down or steel wire brushing scraping down smoke root mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water and applying cement based wall care putty of approved make 1mm thick (average thickness) uniformly whereever required and applying two coats of weather proofing exterior acrylic emulsion paint (applied @ 1.67 litre/10sqm ) of DULUXWeather shield Max or APEX ULTIMA complete all as specified and directed by Engineer-in-Charge.
M & L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement and applying three coats of white lime wash on newly plastered ceiling surfaces including taking down old plaster on ceiling complete all as specified and directed by Engineer-in-Charge.
Dismantling of 100 mm dia Rain water pipes with fittings etc fixed to walls,ceiling, if required including taking out any type of joints complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge.
M&L Mild steel rag or lewis bolts of 12 mm neck dia , screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, not exc 15cm long complete all as specified and directed by Engineer-in-Charge.
M&L for Expanded metal, cut to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised supplied and fixed complete steel staples to steel members complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6, type C2, 75 mm thick,(using 40mm graded agg) finished even and fair laid in alternate bays including filling with bitumastic as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M & L for providing, cement concrete type B1 (1:2:4 using 20 mm graded aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge.
M & L for providing, cement concrete type B1 (1:2:4 using 20 mm graded aggregates) as in copings complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron drain pipes 100 mm dia jointed in cement mortar complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron drain pipes 75 mm dia jointed in cement mortar complete all as specified and directed by Engineer-in-Charge.
M & L for non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white/coloured cement to match with the existing and including cement screeding 15mm thick in cement mortar 1:6 including demolition of old damaged tiles complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia GI tubing and connections including cleaning for re-fixing or new pipes, complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
Taking up or down 20 mm dia GI tubing and connections including cleaning for re-fixing or new pipes, complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each GI 20 mm line should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F 15mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc incl scaffolding, cutting chases in wall where ever required etc and then making the surface smooth by plastering wall with CM 1:4 complete all as specified and directed by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F 20 mm dia GI tubing medium grade with all fitting and fixed to wall using clamps and securing and fixing 15 cm away from wall and ceiling or laid in floors etc incl scaffolding, cutting chases in wall where ever required etc and then making the surface smooth by plastering wall with CM 1:4 whereever required complete, all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each GI 20 mm line should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
M&L for rendering 15 mm thick in CM 1:4 on exterior faces of concrete or brick surfaces of walls or chajjas or pillars finished even and smooth without using extra cement including scaffolding and necessary formwork if required complete all as specified and directed by Engr-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
M & L for preparation of newly plastered surfaces of walls and applying two coats of weather proofing exterior acrylic emulsion paint premier quality on wall surface over one coat of primer oveor 2 mm thick wall care putty from the same manufacturer complete all as specified and directed by Engr-in- Charge Note :- Primer cost included in this item only and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
Complete removal exising old surfaces of wall / ceiling of chajjas by scrubbing with hard brushing ,brooming down or steel wire brushing scraping down smook root mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water and applying cement based wall care putty of approved make 1mm thick (average thickness) unifomly and applying Two coats of weather proofing exterior acrylic emulsion paint of DULUXWeather shield Max or APEX ULTIMA from Asian paint over one coat of primer from the same manufacturer complete all as specified and directed.
S&F 100 mm dia bore sand cast iron soil waste and vent pipes in any length with or without ears, with cement joints fixed to walls or laid in trenches complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two CI pipes should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each CI pipe should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F 75 mm dia bore sand cast iron soil waste and vent pipes in any length with or without ears, with cement joints fixed to walls or laid in trenches complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two CI pipes should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps) and each CI pipe should be minimum 10 cm apart from wall and fixed by using GI clamps placed at 2 m apart throughout the height of bldg (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F in repairs 75 mm dia bore sand cast iron bends diminishing pieces or traps as directed by Engr-in charge
S&F in repairs 100 mm bore cast iron bends,diminishing pieces or traps as directed by Engr-in-charge
M&L for sealing/grouting around pipe penetration of toilets/kitchen/bathrooms by chipping and exposing sides of pipes and grouting with 1:4 cement plaster mixed with integral waterproofing compound complete all as specified and as directed by Engineer-in-Charge.
M & L for protection screed 1:2:4 in 30-40 mm thickness laid to be admixed with integral waterproofing compound confirming to IS 2645 at the rate of 0.10 kg per bag of cement. Note : Integral waterproofing compound to be paid separately under appropriate item
Supply only integral waterproofing compound confirming to IS 2645 complete all as specified and as directed
S & F in repairs Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded with glazing bars incl preparation of steel surfaces and applying one coat of red oxide primer and 02 coats of enemal paint complete all as specified and directed by Engineer-in-Charge.
S & F stainless steel wire cloth.0.36mm nominal dia of wireand average width of aperture1.40mm and fixed withstainless steel wire staples Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
S & F 4 mm sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
M & L for Glazed ceramic coloured tiles 200x300x 7 to 10 mm or 300x600 x 7 to 8 mm thick in dado, set and jointed in neat cement slurry and pointed in colour cement to match including rendering 10mm thick in cement mortar 1:4 including demolition of old damaged tilescomplete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster from brick or stone walls or ceiling incl racking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed by Enginer in Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
M&L for 5mm thick rendering in cement mortar 1:3 on any ceiling concrete surface finished even and smooth surface without using extra cement complete all as specified and directed. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
Preparation of old decorated surface (plastered or unplastered) of ceilings incl cornices pillar etc by brooming down or steel wire brushing, scraping down smoke root mould moss and efforesceent salts and treating oil and greasy spots as applicable and applying two coata of white lime wash on ceiling surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of newly plastered surfaces of ceilings and applying two coats of white lime wash premier quality on wall surface over one coat of primer from the same manufacturer complete all as specified and directed by Engr-in- Charge Note :- Primer cost included in this item only and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
M&L for rendering 15 mm thick in CM 1:6 on interior faces of concrete or brick surfaces of walls or chajjas or pillars finished even and smooth without using extra cement including scaffolding and necessary formwork if required complete all as specified and directed by Engr-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4
M& L for preparing newly plastered surfaces and applying two coats of Oil Bound Distemper using roller brush to give an even and smooth surface having no sign of brush marks complete all as specified and directed by Engineer-in-Charge.
S&F Cast iron floor trap 75 to 100mm dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP grating 75 to 100 mm dia, complete all as specified and directed by Engineer-in-Charge.
M&L switch piano type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
M&L for ceiling rose, surface polycarbonate isolated body three terminals complete all as specified and directed by Engineer-in-Charge..
S&f exhaust fans metal body, AC single phase 230/240 V of size 300 mm sweep with louver shutter for fixing of exhaust fan including provn. of 3 core of size 1.5 Sqmm complete all as directed by Engr-in-Charge.
S&F fresh air fan/ventilating fan PVC body AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed. Make:- Legrand Cat Part No. 607841 or equivalent of L&T/ABB/Seimens.
S & F water heater storage type Geyser vertical type with suitable size of fastner and including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity, should be glass line coated, capacity 25 Ltrs, having heating element 1.5 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed .
Supply & Fixing of ceiling fan 1200mm sweep, 230 Volt, white colour, 5 star rated, complete with all accessories, nuts bolts, clamps, down rod including electronic fan regulator switch type complete all as specified and directed by Engr-in-charge.
S & F electronic fan regulator 5 step,360 degree rotation complete all as specified and directed by engr-in charge.
Supply and fixing ceiling fans Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, AC single phase 230/240 V of size 1200 mm sweep including remote and fan regulator including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as specified and directed by Engineer-in-Charge.
Supply and fix GI Pipe 32 mm dia Medium grade galvanised with all fittings and fixed complete to existing walls, for hanging of ceiling fan 1200 mm sweep, of including clamps, nut & bolts complete all as directed
M&L for breaking old existing wall and making a provn for fixing of 300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified.
M & L for Point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia ) 1100 volts drawing concealed in wall & including non metalic rigid PVC conduuit mediium grade, ISI marked not less than 20 mm dia MS steel terminal boxes not less than 1.6 mm thick of required size (factory made) terminal boxes and with top cover of 3 mm thick hylam sheet of white colour including one run of 1.5 SQMM FRLS 1100 Volts copper conductor cable (green colour) as earth continuity connected to common earth for one light point complete all as specified and directed by Engr-in-Charge for the followings:- Note :- (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
One light /Ceiling fan/exhaust fan/ bell point controlled by one switch.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on Ind board
All as per item No.69 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed by Engineer-in-Charge.
M&L socket outlet 5 Amps 5 pin flush type complete all as specified and directed by Engineer-in-Charge.
M& L Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed by Engineer-in-Charge.
S & F switch piano, flush type, single pole, one way 15 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge..
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20-22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 105 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engr-in-charge.
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed by engr-in-charge.
S&F in replacement of LED 9 to 10 watts bulkhead fitting with poly carbonate aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed complete all as specified and directed by Engr-in-charge.
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engr-in-charge.
S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV complete as specified and directed by engr-in-charge.
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 25mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers complete all as specified and directed by engr-in-charge.
S&F wall mounted fan 400 MM , 3 blade white colour, 230 Volts, 50 Hz 1420 RPM with 90 degree oscillation and having speed control and oscillation by pull cord system all as specified and directed.
Supply and fixing heavy duty exhuast Fan 450 mm sweep, 1400 RPM, metallic body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 1.5 sqmm complete all as specified and as directed.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specifiedby Engr-in-charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB DB SPN 8 way, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB DB SPN 12 way, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB SPN 40 to 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S&F in repair MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed / surface of walls complete all as specified and directed. Note:- Three runs of cable shall be measured as one lenth
S&F in repair Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed /surface of walls complete all as specified and directed. Note:- Three runs of cable shall be measured as one lenth
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron steel wire of 4mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified.
Note: Total amount of Sch of credit is Rs. 18680.00 as per sch of credit. Net contract sum shalls be total quoted amount of bidder (-) amount of Sch of credit.
GIAN ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .