Loading…
Loading…
Tender Value
₹9.1 L
EMD Value
₹45,267
Closing Date
26 Jun 2026, 6:00 pm
Director RGCA
Rajiv Gandhi Centre for Aquaculture, (MPEDA, Ministry of Commerce and Industry, Govt. of India), 3/197, Poompuhar Road, Karaimedu Village, Sattanathapuram Post, Sirkali Taluk, Mayiladuthurai District, Tamil Nadu Pincode - 609109
Additional Repair and Renovation works for Broodstock section and Overhead Tank at RGCA Seabass and Mudcrab Hatchery Project Koozhaiyar Road Thoduvai Village, Thirumullaivasal Sirkali (Taluk), Mayiladuthurai (District), Tamil Nadu
2026_RGCA_911766_1
26629
Open Tender
Civil Works - Buildings
Koozhaiyar Road Thoduvai Village
Please refer Tender documents
5 documents required · 5 mandatory
₹1,180
Yes
Rajiv Gandhi Centre for Aquaculture (RGCA)
₹45,267
Yes
5 Jun 2026
5 Jun 2026
29 Jun 2026
6 Jun 2026
26 Jun 2026
6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1PAINTING WORKS DSR 13.44.1 - Finishing walls with water proofing cement paint of required shade | ||||||
| 1.01 | New work (Two or more coats applied @ 3.84 kg/10 sqm) | 2,700 | Sq.mt | - | - | 1.01 |
| 2DSR 13.52 - Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. | ||||||
| 2.01 | DSR 13.52.1 - On Steel work | 600 | Sq.mt | - | - | 2.01 |
| 3DSR 13.52 - Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. | ||||||
| 3.01 | DSR 13.52.1 - On Concrete work | 450 | Sq.mt | - | - | 3.01 |
| 4UPVC DOORS DSR 9.147 - Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, lastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all orners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. | ||||||
| 4.02 | DSR 9.417.A1.3 - using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height above 1.8m). | 10 | Sq.mt | - | - | 4.02 |
| 5 | CONCRETE WORKS DSR 5.3 - Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 8 | Cu. Mt | - | - | 5 |
| 6DSR 14.1 - Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge | ||||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
TenderDocument.pdf
Tender Documents • 1.49 MB
TenderForms.pdf
Additional Documents • 0.40 MB
BOQ_958244.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid