Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.2 LAccepted-Finance | ₹3.2 L | L-1 | Accepted-Finance accepted |
| 2 | L-2₹3.3 L+₹14,559 (4.57%)Rejected-Finance | ₹3.3 L+₹14,559 (4.57%) | L-2 | Rejected-Finance Rejected |
| 3 | L-3₹3.7 L+₹50,339 (15.8%)Rejected-Finance VILL SOBLI P O DEVNAGAR TEHSIL RAMPUR DISTT SHIMLA H P | SHIMLA | SHIMLA | HIMACHAL PRADESH | ₹3.7 L+₹50,339 (15.8%) | L-3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | RANA MADHVINDER SINGH L1 | M/S Satya Dev L2 | M/S KEDAR BHALUNI L3 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point /fan point/exhaust fan/call bell point with 1.5sq. Mm. PVC insulated heat resident flam redardant (HRFR)and low smoke single core flexible copper conductor cable in PVC Casing & Caping and earthing the light point with 1.5sq mm. HRLRFRLS / PVC insulated single core cooper condutor cable as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge ( Group-B) | 65 | Point | 1,300 ₹84,500 Lowest | 1,310 ₹85,150 | 1,450 ₹94,250 |
| 2.00 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. | 120 | Mtr | 400 ₹48,000 Lowest | 410 ₹49,200 | 500 ₹60,000 |
| 3.00 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. | 160 | Mtr | 510 ₹81,600 Lowest | 520 ₹83,200 | 600 ₹96,000 |
| 4.00Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. | ||||||
| 4.01 | 2x1.5 Sq. mm. | 70 | Mtr | 300 ₹21,000 Lowest | 360 ₹25,200 | 400 ₹28,000 |
| 4.02 | 2x10 Sq. mm. | 9 | Mtr | 750 ₹6,750 Lowest | 800 ₹7,200 | 800 ₹7,200 |
| 5.00 | Supplying and fixing metal box of size 100mmx100mmx60mm deep on surface /ressed suitable size phenolic laminated sheet cover in the front including provinding and fixing 5 pin 5/6 Amps socket outlet and 5/6 amps , piano type switch, connection, painting etc as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge.. | 16 | Nos. | 330 ₹5,280 Lowest | 340 ₹5,440 | 400 ₹6,400 |
| 6.00 | Supplying and fixing metal box of size 180mmx100mmx60mm deep on surface /ressed suitable size phenolic laminated sheet cover in the front including provinding and fixing 6 pin 15/16 amps socket outlet and 15/16 amps , piano type switch, connection, painting etc as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. | 12 | Nos. | 539 ₹6,468 Lowest | 600 ₹7,200 | 600 ₹7,200 |
| 7.00Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- | ||||||
| 7.01 | Single pole. Cat-A. | 19 | Nos. | 235 ₹4,465 Lowest | 300 ₹5,700 | 280 ₹5,320 |
Tender Value
₹3.5 L
EMD Value
₹7,005
Closing Date
19 Mar 2026, 5:00 pmClosed
EE Rampur
JSD Rampur
Providing LWSS to various Habitation of GP Jahoo and Khunni Panoli in Tehsil Nankhari Distt. Shimla HP
2026_HPIPH_131421_1
EE-JSD-RMP-E-ten/25-15678-728 dt 10.3.26
Open Tender
Civil Works
Item Rate
90 days
Nankhari
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹7,005
4 Jul 2026
12 Mar 2026
20 Mar 2026
12 Mar 2026
19 Mar 2026
12 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point /fan point/exhaust fan/call bell point with 1.5sq. Mm. PVC insulated heat resident flam redardant (HRFR)and low smoke single core flexible copper conductor cable in PVC Casing & Caping and earthing the light point with 1.5sq mm. HRLRFRLS / PVC insulated single core cooper condutor cable as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge ( Group-B) | 65 | Point | - | - |
| 2 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. | 120 | Mtr | - | - |
| 3 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. | 160 | Mtr | - | - |
| 4Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. | |||||
| 4.01 | 2x1.5 Sq. mm. | 70 | Mtr | - | - |
| 4.02 | 2x10 Sq. mm. | 9 | Mtr | - | - |
| 5 | Supplying and fixing metal box of size 100mmx100mmx60mm deep on surface /ressed suitable size phenolic laminated sheet cover in the front including provinding and fixing 5 pin 5/6 Amps socket outlet and 5/6 amps , piano type switch, connection, painting etc as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge.. | 16 | Nos. | - | - |
| 6 | Supplying and fixing metal box of size 180mmx100mmx60mm deep on surface /ressed suitable size phenolic laminated sheet cover in the front including provinding and fixing 6 pin 15/16 amps socket outlet and 15/16 amps , piano type switch, connection, painting etc as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. | 12 | Nos. | - | - |
| 7Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- | |||||
| 7.01 | Single pole. Cat-A. | 19 | Nos. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_194285.xls
BOQ • 0.28 MB
F6.pdf
Tender Documents • 0.66 MB
F8.pdf
Tender Documents • 1.07 MB
TC.pdf
Tender Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .