Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹93.4 LAccepted-AOC | L-1 | Accepted-AOC Lowest Amount Quoted | |
| 2 | L-2₹94.4 L+₹50,516.22 (0.54%)Rejected-Finance | L-2 | Rejected-Finance Not being L-1 | |
| 3 | L-3₹94.4 L+₹55,371.03 (0.59%)Rejected-Finance | L-3 | Rejected-Finance Not being L-1 | |
| 4 | L-4₹94.6 L+₹71,111.46 (0.76%)Rejected-Finance | L-4 | Rejected-Finance Not being L-1 |
Tender Value
₹93.9 L
EMD Value
₹1.9 L
Closing Date
17 Dec 2021, 2:30 pmClosed
Er Pardeep Singh Kataria
Executive Engineer, BC and Township Division, BBMB, Nangal Township
Renovation of Bhakra Beas Design office at Nangal Township
2021_BBMB_76579_1
685/21/TS
Open Tender
Civil Works
Tender cum Auction
540 days
Nangal Township
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
₹1.9 L
17 Oct 2022
15 Nov 2021
17 Dec 2021
15 Nov 2021
17 Dec 2021
15 Nov 2021
Amount
Civil Work - Schedule Items
Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50m lead (The cost of new tiles or bricks excluded) (CSR item No. : 31.11)
10mm thick cement plaster 1:3 (CSR item No. : 15.5)
Extra for providing and mixing water proofing material in cement plaster work @ 1 kg per 50 kg of cement. (CSR item No. : 15.47)
Applying bitumen on roofs including heating and carriage to roof. (CSR item No. : 13.53)
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR item No. : 13.55)
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (CSR item No. : 13.45)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./ sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (CSR item No. : 13.74)
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a) UPVC 110 mm bend (CSR item No. : 13.75 (a))
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. a) Doors of area 3 sqm and below (L/R). (CSR item No. : 8.26 (a))
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. b) Windows of area 3 sqm and below (L/R) (CSR item No. : 8.26 (b))
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. c) Clerestory windows of area 3 sqm and below (L/R) (CSR item No. : 8.26 (c))
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections conforming to Is:733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and panelling to be paid for separately) a) For fixed portion and chaukhats (CSR item No. : 17.45 (a))
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections conforming to Is:733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and panelling to be paid for separately) b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required (CSR item No. : 17.45 (b))
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic items) ii) Float glass panes of 5mm thickness (CSR item No. : 17.47(i))
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. (CSR item No. : 17.46 (ii))
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete a) 250mm x 16mm (CSR item No. : 17.49-B)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless, Stopper and screw etc. for these fittings (Excluding sliding bolt) (ii) For shutter area above 0.50 sqm (CSR item No. : 17.23 (ii))
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete a) I.S.I Designation No. III (size of door 851mm to 1000mm) (CSR item No. : 17.43 (c))
12.5 mm thick cement plaster 1:6 (CSR item No. : 15.11)
20mm thick cement plaster 1:6 in two coats work (CSR item No. : 15.28)
Plastering on under side of ceiling 6mm thick cement plaster 1:4 (CSR item No. : 15.42)
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ) b) Size 800x800 mm (CSR item No. : 14.113 (b))
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ) a) Size 600x600 mm (CSR item No. : 14.113 (a))
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (CSR item No. : 14.127)
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete white cement slurry in joints including corners angles and beading. (CSR item No. : 14.72)
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (CSR item No. : 14.89 (b))
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material (CSR item No. : 14.3)
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material (CSR item No. : 14.6)
Floating coat of 1.5mm thick neat cement laid in one operation to the topping. (CSR item No. : 14.4)
Providing & fixing glass strips 4mm thick in floors. (a) 40 mm wide (CSR item No. : 14.105 (b))
Scraping :- Cement Plaster (L/R) (CSR item No. : 8.31 (c))
115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure (CSR item No. : 11.36)
Dismantling brick work tile masonary or tile lining. L/R (B) in cement (CSR item No. : 8.5 (b))
Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position :- (a) R.S. Joists (CSR item No. : 18.1 (a))
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or molded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. (CSR item No. : 18.4)
Providing & Fixing of 10 guage welded mesh of 25mm x 25mm size fixed on steel glazing with M S flat 20mm x 6mm beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming coat. (CSR item No. : 18.31)
Applying priming coat with metal primer on new steel or iron work including preparation of surface. (CSR item No. : 16.20)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. (CSR item No. : 16.17)
Cement Concrete 1:2:4 with stone ballast or shingle mixing by machanical means using concrete mixer volumetric type. (CSR item No. : 10.13 (a) (ii))
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. (CSR item No. : 18.39)
Providing & fixing 16 gauge stainless steel pipe gate of grade 304 duly fixed at site with the help of M.S pivot & hinges grouted in cement concrete complete in all respect as per any kind of drawing & design (CSR item No. : 18.47)
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. (CSR item No. : 9.6)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (CSR item No. : 9.8)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (CSR item No. : 10.20)
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (CSR item No. : 18.18)
Earth work excavation in ordinary soil, exclusive of compensation of earth :--(a) Kassi work undressed involving an average horizontal throw upto 2.0 metres and an average vertical lift upto 0.5 metre including breaking of clods. (CSR item No. : 6.2 (a))
Cement concrete 1:8:16 with stone aggregate 40 mm gauge mixing by mechanical means using concrete mixer volumetric type. (CSR item No. : 10.6 (b) ii)
Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. (CSR item No. : 14.138)
Dismantling concrete reinforced cement concrete. (CSR item No. : 8.6 (e))
Scraping of bricks dismantled from bricks works in lime or cement (CSR item No. : 8.31 (e))
Carriage of Bricks lead 1 km including loading & unloading. (CSR item No. : 5.2 (vi) & 4.3)
Carriage of Bricks Bats lead 1 km including loading & unloading (CSR item No. : 5.2 (i) & 4.1 A)
Loading of Stone (building or pitching) Sand, Earth, Fly Ash, Bajri, Shingle, Spalls, Brick bats, Brick ballast and Stone metal. (By Manual Means) (CSR item No. : 4.2 (A))
Carrage of Earth, Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth. (Lead 0.5 to 1.0 km) (CSR item No. : 5.2 (i) )
CIVIL WORK - Non-Schedule Items
S.S jali (NS)
S.S jali with aluminum (fixed) (NS)
Cement concrete 1:6:12 with brick aggregate40mm gauge mixing by mechanical means using concrete mixer volumetric type. (AOR)
Providing and fixing vitrified floor tiles 9.5 mm thick 300x300mm (vitrified) in flooring skirting ;and dado in 12.5mm thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners angles and beading (NS)
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. (Bricks supply to the contractor free of cost) (NS)
Providing & fixing of PVC ceiling with parameter channel, runner, hanging strips & PVC panel with metal rawl plug and screw for fixing parameter with & G.I nuts &bolts 25x5mm&G.I connecting clips complete in all respect as per instructions/Approval of the Engineer –in charge. (AOR)
Labour for broken of brick aggregate as required size (AOR)
Water Supply - Schedule Items
Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineering- charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects. For Ordinary gravel soil having gravel upto 40% (CSR item No. : 29.1 A (ii))
Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type (CSR item No. : 10.9 (b) (ii))
Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS: 651-2007 class 5p-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the supporting benching, hunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun jute yarn as per IS:1887, finishing and trowelling of each joint at an angle of 45 degree with the longitudinal axes of pipe watering, keeping the joint covered and wetted till the same are curd testing the sewerage line of leakage and defects good as laid in the contract specification and chipping and finish the cut surface to uniform finish to the entire b) 150mm i/d pipe (CSR item No. : 29.41 (b))
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket TypeB b)110mm o/d SWR UPVC pipe lines laid complete (CSR item No. : 30.74 (iii) B (b))
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket TypeB c) 90mm o/d SWR UPVC pipe lines laid complete (CSR item No. : 30.74 (iii) B (c))
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. A) or 110mm O/D pipe iv) vent cowel (CSR item No. : 30.81 (iii) (B) (vi))
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. A) or 110mm O/D pipe iii) Coupler (CSR item No. : 30.81 (iii) (B) (viii))
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. A) or 110mm O/D pipe i) Elbow 90 Degree (all side socketed ) (CSR item No. : 30.81 (iii) (B) (v))
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. A) or 110mm O/D pipe ii) Single Tee (CSR item No. : 30.81 (iii) (B) (iii))
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. A) or 110mm O/D pipe V) P Trap/Floor Trap 110mm x 75mm (CSR item No. : 30.81 (iii) B (X))
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. B) or 90mm O/D pipe i) Coupler ( description changed) (CSR item No. : 30.81 (iii) (C) (viii))
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) b) 110mm o/d (CSR item No. : 30.77 C (b))
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) c) 90mm O/D (CSR item No. : 30.77 (c))
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (b)100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm (CSR item No. : 30.99 (b))
Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete. a) 15 mm i/d (CSR item No. : 28.35 (a))
Providing, fixing and jointing G.I. Union couplings (of approval make with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. a) 15 mm i/d G.I Union (CSR item No. : 28.40 (a))
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to its original condition. a) Size 75mmx75mm (CSR item No. : 30.85 (A))
Cutting holes upto 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.(L/R) b) Through wall 22.86 cm thick (CSR item No. : 28.56 (b) )
Providing & fixing in position 15mm i/dia bib cock of approved make to the approval of the EIC complete in all respect. i) CP Brass bib cock long nose/long body foam flow without flange (CSR item No. : 30.65 A (i))
Providing and fixing in position stop cock/ Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. b) C.P. brass 15mm angle valve without flange (CSR item No. : 30.66 (c))
Providing and fixing in position stop cock/ Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. b) C.P. brass 15mm Concealed stop cock with flange (CSR item No. : 30.66 ( b))
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P brass waste 32mm die with one C.P brass pillar tap including rack bolt screw pair 115mm long complete in all respect. ii) Size 550mmx400mmx815mm (CSR item No. : 30.32 (ii))
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin. (CSR item No. : 30.43 (i))
Providing and fixing PVC waste pipe 32mm complete in all respect. (CSR item No. : 30.20)
Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect. (CSR item No. : 30.15)
Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer -in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. a) Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. (CSR item No. : 30.3 (a))
Providing and fixing in position chinaware European type water closet with P trap or S trap size of approved make (to the approval of the Engineer-in-charge) consisting of 10 Letter. PVC flushing cistern, PVC short bend 32mm die including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (CSR item No. : 30.4)
Providing and fixing stainless steel health faucet complete in all respect. (CSR item No. : 30.24)
Providing and fixing jet spray with 2’-6” long PVC pipe. a) With C.P brass nut (CSR item No. : 30.8(a))
Providing and fixing in position 5mm thick beveled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with crawl plugs 50mm, C.P. brass screws and washer and S/S studs on top complete in all respect (as required by the Engineer-in-charge) (a) Size 600mmx450mm (CSR item No. : 30.61(a))
Providing and fixing in position towel rail/ ring of approved make (to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. (b) C.P. towel ring (CSR item No. : 30.58(b))
Providing and fixing in position PVC flexible tube connection of approved make ( to the approval of Engineer-in-charge) complete in all resprct. ( a) PVC tube connection of size 15mm x 600 mm with C.P. Brass nut. (CSR item No. : 30.72(f))
Providing and fixing in position S.S. grating with frame of approved make ( to the approval of Engineer-in-charge) complete in all respect. (CSR item No. : 30.80)
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. a) Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal (CSR item No. : 29.60 (a))
Making connection with the existing G.I. branch main up to 40 mm size pipe including cutting of existing pipe threading of pipe lines from both ends and fixing of G.I. etc. in the pipe line (including cost of G.I. Tee) complete in all respect. (CSR item No. : 28.45)
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floor with cement concrete 1:2:4 mix (1 cement :2 concrete sand : 4 : graded stone aggregate 20mm nominal size) cement plastered on both side with cement mortar 1:2 (1cement : 2 coarse sand ) finished with a floating coat of neat cement and making necessary channals for the drain etc. complete. (a) For pipes 100 to 250mm Diameter (CSR item No. : 29.65 (a))
Water Supply - Non Schedule Items
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat iron not less than 5mm (MR )
Electrical - Schedule Items
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- a) Wiring fan point (Without fan box) (CSR item No. : 34.02 (i) (a) )
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- b) Wiring light point (CSR item No. : 34.02(ii) )
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- c) Wiring call-bell point (CSR item No. : 34.02 (iii) )
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- d) Wiring 6 Amp. plug control comprising wall socket point (CSR item No. : 34.02 (v) )
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- f) Wiring 16/20 amp. power plug control point. (CSR item No. : 34.02(vi) )
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4sq.mm (Un-sheathed) (CSR item No. : 34.09 (iv))
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- (iii) SP&N Double Door Distribution Board 12 way each (CSR item No. : 34.17 (iii))
MINIATURE CIRCUIT BREAKERS Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- i) MCB Single Pole 6-32amp. (10kA, Curve-C) (CSR item No. : 34.16 A (ii))
MINIATURE CIRCUIT BREAKERS Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- ii) MCB Double Pole 6-32amp. (10kA, Curve- C) (CSR item No. : 34.16 A (vi))
MINIATURE CIRCUIT BREAKERS Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- iii) MCB Double Pole 50, 63amp. (10kA, Curve- C) (CSR item No. : 34.16 A (viii))
Electrical - Non Schedule Items
Providing & Fixing Exaust Fan 10'' Heavy duty complete in all respect as per instructions/ Approval of the Engineer –in charge. (NS)
Providing & Fixing wall fan complete in all respect as per instructions/ Approval of the Engineer –in charge. (NS)
Providing & Fixing LED tube set 36 watt complete in all respect as per instructions/Approval of the Engineer –in charge. (NS)
Providing & Fixing LED Light 9 watt complete in all respect as per instructions/Approval of the Engineer –in charge. (NS)
Bidder Name
Amount in Words
ANMOL KATYAL CONTRACTOR
VINOD KUMAR SHARMA
SUBASH CHAND
SUDHIR ANAND
VINOD KUMAR SHARMA
SUBASH CHAND
SUDHIR ANAND
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .