Tender Value
Refer Docs
EMD Value
₹53,900
Closing Date
7 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Allahabad
HQ CWE New Cantt Allahabad
REPAIR/ MAINTENANCE OF HT DISTRIBUTION SYSTEM AND VACCUM CIRCUIT BREAKER AT OLD CANTT ALLAHABAD UNDER GE (EAST) ALLAHABAD
2020_MES_373585_1
81551/E/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (East) Allahabad
₹53,900
Yes
2 Dec 2020
31 Aug 2020
10 Oct 2020
1 Sept 2020
7 Oct 2020
23 Sept 2020
60 days
Amount
Excavation in trenches/ pits in soil (soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out complete all as specified and directed.
Returning, filling in with the earth obtained from item No.01 here-in-before including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and laying Sub class 'B' bricks(old size) laid flat in trenches as cable covers complete all as specified & directed.
M&L for clean and dry sand (unwashed) in trenches around the cable for cushioning complete all as specified & directed. Note :- Sand cushioning 8cm before laying the cable and 15cm after laying the cable & punned down 18cm,and punned thickness shall be measured and paid.
Supply,laying,testing and commissioning in pipes/ ducts/ poles/ trenches/ under floor/ under road XLPE insulated steel strip or wire armoured cable screened PVC heavy duty with aluminium conductor,11000 Volt grade(earthed) of cross section area 95 Sqmm,3 core complete all as specified and directed.
Supply, laying, testing and commissioning in pipes/ ducts /poles/ trenches/ under floor/under road XLPE insulated steel strip or wire armoured cable screened PVC heavy duty with aluminium conductor,11000 Volt grade(earthed) of cross section area 120 Sqmm,3 core complete all as specified & directed.
Supply and laying 80mm bore GI pipe 'light grade' in trenches,under floors,roads,along poles for protection of cables,including sealing ends complete all as specified & directed.(MS Clamps to be measured and p[aid under appropriate item)
M&L for painting of 11m steel pole with cross arms, claim of any length and shape for HT overhead line with one coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30cm by fluorescent paint, from bottom of pole above coping to 1.5 mtr height complete all as specified and directed.
M & L painting of two pole structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with one coat of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30cm by fluorescent paint, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed.
M & L painting of four structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with one coat of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30cm by fluoroscent paint, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed.
Taking down carefully switch air break, gang operated, triple pole complete and supply, installing, connection and commissioning switch air break gang operated, triple pole, outdoor type of 12 insulators, mechanically operated, mounted of insulators and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe worked from ground leel, with locking arrangements, for current rating 400 Amp at 11 KV, complete all as specified and directed.
Supply and fixing in replacement of lightning arrestor suitable for 11 KV grade, non Iinear resistance type, complete with all fitting transmission class for outdoor discharge capacity 65KA complete all as specified and directed.
S&F in replacement disc type insulator,porcelain,vitreous,white brown or green,145 mm high and 225mm dia ball and socket type single disc assembly for tension with tension clamps for conductors,working pressure 11000 volts grade complete all as specified and directed. Make - Southern insulator/Reychem/Birla 3M/Jaipuria
S&F in replacement pin type insulator,porcelain,vitreous,white brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,150 mm height and 150mm dia suitable for working pressure 11000 volts grade complete all as specified and directed. Make - Southern insulator/Reychem/Birla 3M/Jaipuria
Restringing tightening of HT/LT overhead line conductor of any size ACSR conductor four to six wire after opening from insulators,including replacement of all warnout jumper connections/nuts/bolts/washers and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
Restringing tightening of GI earth continue conductor of size 4mm dia HT over head line after opening from insulators,including replacement of all warnout jumper connections/nuts/bolts/washers and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
M/L for cutting, pruning, triming and vending tree branches along HT/LT over head lines at places within a radius of 2 metre from fasted conductor of span 40 to 55 mtr length and removing from site after arranging electrical shut down, including taking all precautions while working on lines using own T&P by the contractor complete all as specified and directed.
M&L for cross arms,bracing,supports,clamps and back plate,fabricated from structural electrical shut down,including nuts,bolts,washers,welding,bending cold or hot,drilling holes for bolts,in any shape or size including two coats synthetic enamel paint over a coat of red oxide primer complete all as directed. Dismantling and taking out damaged/ruste cross arms,bracings,supports,clamps and back plates from existing poles/dismantled poles/pole structures complete all as specified and directed.
M&L for stringing ACSR conductor of required size for O/H lines,on HT/LT poles,including binding wire, including dismantling existing conductor complete all as specified and directed.
M&L stringing,galvanised steel wire 4mm dia for earth coductor,on HT/LT poles including binding wire etc including dismantling existing GI wire complete all as specified and directed.
S&F stay assembly (in replacement) consisting of galvanised stay wire 7/10 SWG stay bow of 14 mm dia, stay rod 20mm dia 180cm long with loop insulators stay plate 230 x 230mm x6mm with PCC foundation 1:3:6 type C2 complete with stay clamps,bolts and nuts all as specified and directed by Engr-in-Charge including the following :- (a) Excavation and earth work for stay foundation in soft/loose soil,disposal of surplus soil to a distance n. exc. 50 metres & depositing where directed at a level n. exc. 1.5mtr from the starting point as directed. (b) PCC 1:3:6,type C-2(using 40mm graded stone aggregate) as in embedding blocks all as specified.
M&L danger notice plate for HT 25 cmx20cm x 1.5mm thick mild steel sheet,vitreous enameled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts complete all as specified and directed.
Supply and fixing cold shrinkable,straight through joint box for XLPE HT U/G cable,11KV grade suitable for cross sectional area 95Sqmm 3 core XLPE out door type XLPE cables complete all as specified and directed. Make : M Seal/ Reychem/Cabseal. (Note :- The rates quoted shall deemed to be included the charges of fault locator machine/eqpt fromUPPCL or any other elect agency as available.
Supply and fixing cold shrinkable,straight through joint box for XLPE HT U/G cable,11KV grade suitable for cross sectional area 120 Sqmm 3 core XLPE out door type XLPE cables complete all as specified and directed. Make : M Seal/ Reychem/Cabseal. (Note :- The rates quoted shall deemed to be included the charges of fault locator machine/eqpt fromUPPCL or any other elect agency as available.
Supply and fixing in replacement cable end termination cold shrinkable type 11KV grade suitable for sizes of XLPE cable 95 Sqmm 3 core indoor type complete all as specified and directed. Make : M Seal/ Reychem/Cabseal.
Supply and fixing in replacement cable end termination cold shrinkable type11 KV suitable for sizes XLPE cable 95 Sqmm 3 core outdoor type complete all as specified and directed. Make : M Seal/ Reychem/Cabseal.
M&L for Calibration of VCB CHECKING (All connections and mechanism) cleaning servicing overhauling,testing complete of 3 phase 11 KV vaccum circuit breakers any make/type as mentioned below :-
(a) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking CTs 03 Nos of each VCB for insulation and saturation calibrating with the help of primary injection & testing kit for primary triping system in presence of Engr-in-Charge/rep of Engr-in-Charge and reconnecting the incoming and outgoing HT cables ,complete all as specified and directed. (b) Inspecting, servicing and testing all connections of control wiring availability of proper D.C. supply,incoming and outgoing connections and tightening them,cleaning the contacts and terminal with CTC solution and using the blower for dusting incl replacement of faulty control fuses,indication lamp & testing for satisfactory operation raising and lowering mechanism in presense of Engr-in-Charge, complete all as specified and directed. (c) Taking out IDMT over current relay 01 Nos and earth fault relay 01 No from the 11KV VCB (2 Nos In each) and calibrating the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge complete all as specified and directed.
(d) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking PT 11 KV/110V of each VCB for insulation and accuracy and calibrating the same in presence of Engr-in-Charge/rep of Engr-in-Charge and reconnecting the incoming and outgoing HT cables complete all as specified and directed. (e) Taking out trolly mechanism of VCB 11 KV for checking all mechanical parts,dismantling and replacing defective parts,checking and readjustment of all moving parts,springs,bearings,greasing all moving parts complete all as specified and directed. NOTE : (i) All the instruments,primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost shall deemed to be included in the quoted rates. (ii) All the test record shall be mentained and signed by the testing engineer,contractor and Engineer-in-Charge . (iii) The above work shall be performed by authorised representative i.e. HT expert/ engineer of manufacturere. (iv) Calibration of VCB's will be carriout through OEM only and all the test records duly signed by Engineer in Charge will be maint.
Taking out trolly from VCB , opening of trolly to clean the parts, cleaning of tank, dismentling of existing unserviceable vacuume interrupter and supply, install testing of vacuume interrupter matching to existing one suitable for 11 KV 400 amps HT VCB.
Dismantling of existing unserviceable bus bar spout after disconnecting all incoming and outgoing connections and S/F new bus bar spout of 11 KV 400 Amps VCB matching to existing one including all incoming and outgoing connection complete all as specified and directed.
M&L for checking (All connections and mechanism) cleaning servicing overhauling,testing complete of 3 phase 11 KV Ring main unit any type/make outdoor type respectively as mentioned below :-
(a) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking CTs 03 Nos of each breaker for insulation and saturation calibrating with the help of primary injection & testing kit for primary triping system in presence of Engr-in-Charge and reconnecting the incoming and outgoing HT cables complete of panels ,complete all as specified and directed. (b) Inspecting, servicing and testing all mechanical & electrical parts and the connections of control wiring availability of proper DC supply and AC supply,incoming and outgoing connections and tightening them,cleaning the contacts and terminal with CTC solution and using the blower for dusting testing it for satisfactory operation raising and lowering mechanism in presense of Engr-in-Charge complete all as specified and directed.
(c) Taking out existing over current relay 02 Nos and earth fault relay 01 No from the 11KV breaker B (3 Nos In each) and calibrating the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge complete all as specified and directed. NOTE : (i) All the instruments,primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost shall deemed to be included in the quoted rates. (ii) All the test record shall be mentioned and signed by the testing engineer and contractor and Engineer-in-Charge. (iii) The above work shall be performed by authorised representative i.e. HT expert/ engineer of manufacturere.
Disconnection & taking out old/defective current transformer (CT) from 11 KV VCB panel and supply ,fixing,intallation & testing of current tranformer ,indoor comprising of 3 Nos single phase resin cast CTs of 300-150/5+5 amps ratio ,PS class with 10 V A burden and accuracy suitable for protection & material incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Note:- (i) All the instruments and T & P required for the above jobs shall be arranged by the contractor at site and cost shall deemed to be included in the quoted rates. (ii) The above work shall be performed by authorised representative i.e. HT expert/ engineer of manufacturere.
M&L for replacement of multi function panel meter of VCB with new digital LCD display meter make : secure, model Premier 100 with accuracy 0.5 to measure 3 phase current, voltage, frequency, PF, KWHKVA phase wise and total with provision of RS232/RS485 alongwith optical metering complete with connection and testing complete all as specified and directed.
M&L for filteration and centrifuging of transformer oil complete all as specified and directed. Note :- Centrifuging machine to be arranged by contractor. BDV of test to be noted before and after centrifuging. Centrifuging and cleaning will be carried on until BDV of 50KV with 2.5mm gap . Heaters not less than 5KW should be used. Centrifuging will be done while running of transformer.
M&L for replacement of transformer oil in transformer. Note : Sealed container only will be brought at site with minimum BDV 45 KV complete all as specified and directed. Make : Transol, Power, Savita.
S&F in replacement of silica gel breather of transformer 11/0.433 KV of capacity 63-160KVA complete all as specified and directed.
S&F in replacement of silica gel breather of transformer 11/0.433 KV of capacity 250-315KVA complete all as specified and directed.
S&F in replacement of silica gel breather of transformer of transformer 11/.433 KV of capacity 415 -750 kVA complete all as specified and directed.
S&F in replacement of silica gel only in transformers etc of any capacity complete all as specified and directed.
S&F in replacement of LT bushing of transformer 11/0.433 KV of capacity 63-160KVA complete all as specified and directed.
S&F in replacement of LT bushing of transformer 11/0.433 KV of capacity 200-500KVA complete all as specified and directed.
M&L for steel tubular swaged pole complete with mild steel base plate 30 x30cm x6mm thick,finial taper plug,bolts,nuts,screws as per IS-2713 (Part-II) 1980 made out of mild steel tubing complete type 410SP-55(11.0 m long) including painting with two coats of aluminium paint over one coat of red oxide primer on exposed portion and with two coats of bituminous paint on embedded portion in concrete including marking number on pole including dismantling existing pole and the following :- (a) Excavation in soft/loose soil including returning filling and removal of surplus soil to a distance not exceeding 50m. (b) PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of size 600x600x1800mm. (c) Poviding PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) for plinth block/collar above GL,300mm high and 450mmdia complete all as specified and directed.
M&L for cleaning the area around all the sub station of electrical installation all by cutting/removing unwanted grass and grass bushes complete all as specified and directed. Note : Tools will be provided by Contractor.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galavanised earth lead strip 25mm x 4 mm (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point, supply and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing & taking down of old/ ineffective earthing complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode)
M&L for maintenance/servecing of earth pits at substation and of lightining protection by cleaning in and around the chamber,repair /replacement of MS chamber cover /PCC cover slabs ,removing wild growth needs from the area around earth chamber ,provn of salt water in to earth pits ,repair /replacement of funnel ,checking of earth contunity connecting checking and recording of earth results and painting the results and date of testing etc on the chamber ,all as specified and as directed.
M&L for replacing of phase indicator light LED type for panel in three colours ( R,Y,B) complete all as specified and directed.
Taking down the defective unserviceable transformer from existing site from pole and Sub Stn with the help of man power & chain pully block or by crane etc including dieconnecting all electrical and mechanical connections from the site and carrying to workshop for repair and replacement of old burnt u/s item including transporting of capacity 63 KVA to 250 KVA(including 250 KVA).
All as per srl item No. 47 here in before but 315 KVA to 415 KVA (including 415 KVA)..
Opening Dismantling the transformer of capacity 100 KVA upto and including 250 KVA by lifting the top cover taking out the HV leg coil and LV leg coil and draining out the transformer oil in barral including cleaning the transformer chamber (body) inside and out side throughly with emery paper and cloth than checked the winding and other worn-out parts such as HV/LV coils and other connected items as Tap-changer, breather assembly, bush etc and replacement of new spares i.e. tap changer, bush etc, HV/LV coil rewinding with DPC enamelled copper wire/ strip of adequate size, guage and number of turn complete and connected to existing serviceable strip by jointing with soldring and reinsulation with cotton tape over strip including using insulating material like varnish to limb coil fire proof type and sleeves etc by drying and baking of Insulating material in heating chamber in adequate temprature reassembling the transformer HV/LV connection with help of soldering.Testing of transformer after reassembly complete on No load at workshop and ON load at site incl painting to the transformer with super enameled Heat resistant paint all as specified anddirected. Note -(i) Tap changer, bush will be measured and paid separately as supply only under respective item of Sch 'A'. (ii) M&L for winding of HT/LV coil with DPC enamelled copper/aluminium wire of existing size & guage including insulation, drying baking shall be measured and paid separately under respective item of Sch 'A'. (ii) Distribution transformer shall be got repaired from authorised work shop of Manufacturers or any other works shop which have authoristaion from UPPCL for repair of such capacity transformer. (iii) Following test shall be conducted before installation & commissioning on site. (iii) Following test shall be conducted before installation & commissioning on site. (a) Insulation Resistance Test (by 5000 V megger) (b) Ratio Test (c) Double voltage & double frequency Test (d) Transformer oil value BDV test (e) Tap changing test off load for all tap position
All as per srl item No.49 here in before but transformer of capacity 315 KVA upto and including 415 KVA.
M&L for painting of transformer 65 KVA to 100 KVA externally with one coat heat resistant grey colour paint with spray gun incl surface preparation complete all as specified and directed.
All as per srl item No.51 but capacity 160 KVA to 250 KVA.
All as per srl item No.51 but capacity 315 KVA to 630 KVA.
M&L for rewinding of burnt HV/LV coil of transformer with DPC enamelled copper wire/strip of existing size & guage incl insulating material complete all as specified and directed .
M&L for rewinding of burnt HV/LV coil of transformer with DPC enamelled aluminium wire/strip of existing size & guage incl insulating material complete all as specified and directed .
Supply only HT bush Insulator complete with rod as per existing material & size and nut suitable for indoor/outdoor type transformer 63 KVA.
All as per srl item No. 56 here in before but transformer of capacity 100 KVA to 250 KVA.
All as per srl item No. 56 here in before but transformer of capacity 315 KVA to 415 KVA.
Supply only tap changer for adjusting the voltage with brass parts as per sample of existing for indoor/ outdoor type transformer 63 KVA all as specified and directed.
All as per srl item No. 59 here in before but transformer of capacity 100 KVA to 250 KVA.
All as per srl item No. 59 here in before but transformer of capacity 315 KVA to 415 KVA.
M&L for maintainance /servecing of battery bank system by replacing unservicable batteries ( 2 volts 40Ah , 15 Nos) ,including checking and replacement of electrical acessories of battery charger unit, cleaning the servicable battery terminals by applying petrolium jelly ,checking of electrolyte ,distilled water to make the entire system in good servicable condition all as specified and as directed
Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96 Sqmm with adopter complete with button including taking out old unserviceable Volt Meter all as specified and directed. Make: ENERCON/AE. Note :- The rate quoted shall be deemed to be include the following:- (i) Control wiring for auxiliary supply 440/230 Volts AC if required. (ii) Cutting the sheet of the panel suitable for fixing the voltmeter. (iii) Calibration and testing the meter.
S&F synthetic line separators of HT OH lines with nut ,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for three phase 3 wire HT lines all as directed by Engr-in-Charge.
Minakshi constuction co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .