Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.5 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC OK | |
| 2 | 2₹10.5 L+₹1.0 L (10.8%)Rejected-Finance | 2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | 3₹9.7 L+₹20,780 (2.20%)Rejected-Finance HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | 3 | Rejected-Finance Quoted rate more than L1 |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
21 Dec 2019, 6:00 pmClosed
GE AF BIHTA
GE AF BIHTA Pin-801103
Repair/Maint of AC, Water coolers, refrigerators, Voltage stabilizer, Geysers of various capacity and connected items at AF Stn Bihta under GE (AF) Bihta
2019_MES_290123_1
8923/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF BIHTA
₹22,000
Yes
17 Feb 2020
16 Oct 2019
23 Dec 2019
16 Oct 2019
21 Dec 2019
31 Oct 2019
Amount
Material and labour for taking down from foundation desert cooler, dismantling, opening the same for complete servicing and replacement of wornout MS nut bolt, washser etc, oiling, greasing of fan bearings, bushes etc replacing part of the coller , providing new GI/MS sheet including necessry cutting welding if required and scrapping of rusted/deposited materials from the desert cooler body internally and externally and preparation of steel surfaces of desert cooler and applying two coats of synthetic enamel paint internally & externally on whole body of the desert cooler of existing colour or as directed by Engineer-in-charge over a coat of red oxide primer made the desert cooler fully functional and re-installation and testing complete all as specified and directed by Engineer-in-charge. Note : (i) Items required in repairs shall be measured and paid separately under respective items.
Supply and fixing, tesing and commissioning submersible pump for desert cooler single phase 18 watt 220 volt 50 HZ of existing size & specification including taking out the old unserviceable one complete all as specified and directed .Make- Crompton Greaves/Bajaj/Usha/Khaitan
Supply and fixing ,tesing and commisiioning motor for desert cooler single phase 150 watt 220 volt 50 HZ of existing size and specification including taking out the unserviceable one complete all as specified and directed. Make- Crompton Greaves/Bajaj/Usha/Khaitan
Supply and fixing blade for exhaust fan 500 mm sweep ( three blade) of existing size & specification including taking out the unserviceable one complete all as specified and directed
Spply and fixing Cooling pad (Grass) set of three pads with wire mesh square shape fixing all the side of desert cooler including taking out the unserviceable one all as specified and directed
Supply and fixing PVC flexible pipe for water circulation on grass pads connected through Submersible pump to desert cooler top end for cooling the (Grass) pads including PVC elbow and Junction box of existing size and specifications complete including taking out the unserviceable one all as specified and directed
Supply and fixing stepped rotary switch of existing size & specification including taking out the unserviceable one complete all as specified and directed. Make:Havells/Plaza/ssk/ standard
Supply and fixingr switch plano flush button single pole one way 6 Amp, 240 Volts including taking out the unserviceable one complete all as specified and directed. Make:Havells/Plaza/ssk/ standard
Supply and fixing top plug 6 amps 3 pin , 240 volts complete with connecting PVC 3 core flexible copper wire minimum 2 m length of suitable capacity including taking out the unserviceable one complete all as specified and directed Make:Havells/Plaza/ssk/ standard
Supply and fixing side cover of the desert cooler of size 550 mm x 550 mm ( set of three) of existing specications and capacity including taking down userviceable one complete all as specified and directed.
Supply and fixing water storage tank for desert cooler of size 600 mm x600mm x150 mm of existing specifications, and capacity including taking down unserviceable one complete all as specified and directed
Material and labour for disconnect electric connection, taking down the air conditioner (Split/Window), Water Cooler and Refrigerator including stabilizer of any make and capacity. Servicing complete by cleaning inside, cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gas kit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works and replacement of rusted body with new MS/GI Sheets of existing specification and made the equipment fully functional and re-installation in position and testing complete all as specified and directed by Engineer-in-charge. Note: spare parts will be measured and paid separately under the respective items.
Material and labour for detection and rectification of leakages in gas line of 1.5 Ton/2.0 Ton window / split type AC of any model and make by necessary brazing and ensuring the complete systems leak proof including checking the system and replacement of required spare parts and charging with appropriate quantity of refrigerant gas R-134 A, testing for smooth functioning of AC complete all as specified and directed. Note: Spare parts, if required will be measured and paid separately under the supply of respective items.
Material and labour for taking down the window /Split type AC taking out the unserviceable/worn hermetically sealed unit compressor from window /Split type AC and replacement with new one compressor (company packed) suitable for existing model/make of capacity 1.5 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and charging appropriate qty of refrigerant gas R-134 A after making vacume complete system and testing the AC for proper functioning all as specified and directed.Make: Kirloskar / Techumesh / Carrier / Blue Star/LG/Sri-ram
All as per serial item no.14 here-in-before but for 2.0 TR capacity window / split type AC.
Supply and fixing the following spare parts required in repairs of equipments taken down for servicing vide item No 10 here in above including dismantling, opening the equipments, assembling and testing complete all as specified and directed by Engineer-in-charge.Note : All the repairs shall be carried out at AGE E/M store yard GE(AF) Bihta including transportation of equipment from site to yard and vice- versa and re-fixing at the same location at site. (a) Cooling coil complete with fins made of copper suitable for 2Ton/1.5 Ton capacity Window/Split type AC.ofr existing size and specification. Make : LG/Voltas.
(b) Condensing coil complete with fins made of copper suitable for 2Ton/1.5 Ton capacity Window/Split type AC.of existing size and specification all as directed.. Make : LG/Voltas.
(c) Fan motor upto 120 Ltr capacity water cooler all as directed. Make : CG/ Kirloskar.
(d) Fan blade for AC's blower/ water cooler motor and all as per sample approved by Engineer-in-charge..
(e) Copper condensing coil suitable for water cooler upto 120 Ltr capacity all as directed . Make : Voltas/Blue Star.
(f) Copper cooling coil suitable for water cooler upto 120 Ltr capacity all as directed. Make : Voltas/Blue Star.
(g)Brass chromium plated water outlet tap for water cooler upto 120 Ltr capacity all as directed. Make : Voltas/Blue Star.
(h) Front grill for window for 2Ton/1.5 Ton capacity AC all as directed.
(i) copper valve for Liquid line for ACs upto 2Ton capacity all as directed.
(j) Copper valve for refrigerant line for ACs upto 2Ton capacity all as directed.
(k)Insulation foam heavy duty for ACs refrigerant line all as directed..
(l) Capilary tube for water cooler/ refrigerator/AC of exiting specification and size all as directed.
(m)Vegitable tray upto 320 Ltr capacity refrigerator of existing specifications and size all as directed.
Material and labour for taking down of ceiling fan/ exhaust fan any make and type from ceiling/wall cleaning the fan,replacement of wornout, steel split pin, rubber reel, washer, screws, nut bolts etc. Greesing/ oiling the fan including replacing the connecting wire with existing specifications complete and made the fan functional ,testing and refixing in the same or other position complete all as specified and directed by Engineer-in-charge. Note : Spare partsrequired shall be measured and paid separately under respective items.
Supply and fixing the following items required while servicing/ repairs the ceiling fan/exhaust fans taken down vide serial item No 29 above complete all as specified and directed by Engineer-in-charge.(a) SS clamp for fans of existing specification and size complete all as directed.
(b) Fan capacitor 2.5MFD complete all as directed. Make: Philips/Bajaj/Crompton Greave
(c) Fan capacitor 4/3.15MFD complete all as directed.Make: Philips/Bajaj/Crompton
(d)Mild steel galvanised pipe 15 mm bore 300 mm long for hanging ceiling fan with two nos sutiablle size holes for passing the cable complete all as directed .
(e) Aluminium blades (set of three) for 1200/1400mm sweep ceiling fan complete all as directed. Make : Orient/Usha/Khaitan
(f) Mild steel clamps out of 40x5 mm flat for mounting exhaust fan with frame 300mm/450 mm sweep complete all as directed.
(g) SS blade ( set of three) fo 300 mm/450 mm sweep exhaust fan complete all as directed.
Material and labour for dismantling/ opening the fan taken down for servicing vide item No 29 here-in0before and reassembling and testing complete after the replacing the following spare parts :(a)Supply and fixing fan bearings Make : SKF or as approved by Engineer-in-charge.
(b) Supply and fixing gun metal from bushes all as per sample approved by Engineer-in-charge.
Material and labour for transportation of taken down fans vide item no.29 here-in-before from site to AGE E/M store yard dismantling,opening complete fan and rewinding the same with super enamel copper conductor of suitable size that match the original specifications. Using proper insulation and varnish, sleeves etc reassembling the fan and testeted for 8 hrs to achieve the required speed before refixing at same location at site complete all as specified and directed for the following sizes of fans :Note : (i) Rewinding/ repairs of fans shall be carried out at AGE E/M store yard (ii) Cost of transporation shall deemed to be included in the unit rate quoted by bidder. (iii) Spare part if any required whiler repairs shall be measured and paid separately vide item no. 31 to 34 here-in-before. (a) Ceiling fan 1200/1400 mm sweep.
(b) Exhaust fan 450mm/300 mm sweep
(c) Wall mounted/ Padestern fan 450 mm sweep
Material and labour for taking down of electric water heater 20/25 ltr capacity from walls , dismantling/opening the same,cleaning and servicing complete and replace the wornout MS nut ,bolts, washers, clamps etc with existing size and specifications and made it fully functional reassembling,tested and refixed in the same location complete all as specified and directed by Engineer-in-charge.Note: Spare parts if any reqquired shall be measured and paid separately under respective items.
Material and labour for replacement of the following items required for repairs of electric water heater taken down vide items No 42 here-in-before complete all as specified and directed by Engineer-in-charge. (a) Electric water heater element 2/1.5KW of existing size and specification and make all as directed.
(b) Apparatus (Syphon assembly) plate of existing size and specification and make all as directed.
©Thermostate switch 30-70ºC ranging.of existing size and specification and make all as directed.
(d)Copper vessal (inner tank) of weighting 3.5kg suitable for water heat 25 ltr capacity of existing specifications and make complete all as directed..
(e) SS vessal (inner tank) suitable for 25ltrs capacity water heater of existing specifications and make comlete all as directed.
(f) Copper vesal (inner tank) of weighting 4.5kg suitable for 50ltrs capacity water heater of existing specifications and make complete all as specified and directed.
(g) S vessal (inner tank) heavy duty suitable for 50ltrs capacity water heater.
(h) Indicator lamp neon type 230w of existing specifications and make complete all as specified and directed.
Supply and fixing running capacitor 80/100 mfd + / - 400 V AC, Suitable for 1.5/2.0 TR window / split type AC including taking down unserviceable one complete all as directed. Make : Asian /Bhel / GE / Crompton Greaves.
Supply and fixing starting capacitor 80/100 mfd +/-5% 400 V AC Suitable for 1.5/2.0TR window /split type AC including taking down unserviceable one complete all as directed. Make : Asian /Bhel / GE / Crompton Greaves..
Supply and fixing over load relay including taking down unserviceable one coplete all as directed,Make: - Indofoss/Shri-ram/Usha
Supply and fixing thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split /window type AC. including taking down unserviceable one complete all as directed. Make: - Indofoss/Shri-ram/Usha
Supply andfixing blower/Propeller fan motor single Phase 230 V AC, 50 Hz of existing capacity, specification for indoor unit including taking down unserviceable one complete all as directed.Make: Universal / Compton Greaves/Air Fresh.
Suppy and fixing blower/Propeller fan motor single Phase 230 V AC, 50 Hz of existing capacity,specifications for outdoor unit including taking down unserviceable one complete all as directed.Make: Universal / Compton Greaves/Air Fresh.
Supply and fixing copper stainer/filter suitable for window type 1.5/2.0 TR capacity AC of existing specification and make including taking out the unserviceable one complete all as directed.
Supply and fixing electronic circuit plate (PCB) for Split/Window A/C 1.5 TR/2 TR capacity including taking down unserviceable one complete all as directed . Make- LG/Carrier/Samsung.
Taking out unserviceable voltage stabilizer of capacity 5 KVA /4KVA of any type and make and repair the same to make it functional including the providing the items required to make it fully functional such as indicating meters,push button,cable connector of existing size,specifications ,relay etc complete all as specified and directed
Taking out the unserviceable sealed compressor unit from water cooler of 40/80 ltrs cacacity and providing the new one of same specifications and make( Sealed compressor unit shall be purchased from company and should be sealed packing) duly tested and checking the complete system for leak proof and charging with appropriate quantity of refrigerant gas R-134 A and testing for smooth functioning complete all as directed.
Material and labour for detection and rectification of leakage in gas line in water cooler of any capacity,any type and make and ensuring the system leak proof by necessary brazing /soldering and replacement of required spare parts Including charging of refrigerant R-134 A in appropriate quantity in the system and testing for smooth functioning of water cooler complete all as directed.
Supply and fixing running capacitor 25/30 mfd ± 5%,400 volt for Water Cooler having capacity 40/80/150 ltr iincluding taking down unserviceable one complete all as directed.Make : Usha/voltas/Asian
Supply and fixing over load relay for water cooler having capacity 40/80/150 ltr including taking down unserviceable one complete all as directed. Make : Usha/voltas/Asian
Supply and fixing float valve 15mm dia non-metallic for water cooler having capacity 40/80/150 ltr including taking down unserviceable one complete all as directed. Make : prayag /shakti
Supply and fixing PVC connection of size 15mm dia for water cooler having capacity 40/80 /150 ltrs ncluding taking down unserviceable one complete all as directed. Make : prayag /shakti
Supply and fixing PVC waste pipe of size 25 mm dia for Water Cooler having capacity 40/80 and 150 ltrs including taking down unserviceable one complete all as directed.Make : prayag /shakti
Material and labour for detection and rectification of leakage in gas line of refrigerator 300/310Ltr capacity of any model and make by necessary brazing and ensuring the complete systems leak proof including charging with appropriate quantity of refrigerant gas R-134 A including testing for smooth functioning and replacement of required spare parts complete all as specified and directed. Note: Spare parts like filter, capillary tube, cooling coiled, condensing coil if required will be measured and paid separately
Material and labour for replacement of relay, suitable for 300/310 Ltr refrigerator of any make/model including taking down unserviceable one complete all as directed.Make: Sri-ram/Usha /Renutrol /Indofos)
Material and Labour for transportation of split type/ Window type AC 1.5 TR / 2 TR capacity of any make/model from site to E/M store yard testinf/repair and from E/M store yard to site within AF complex after testing/repair.Installation of indoor and outdoor unit where as directed including, making hole through the wall for and passing the suction/discharge line and PVC coduit of 25 mm dia minimum.3.5 mtr long in concealed surface of wall for drainage of water occurs due to humidity and making good the disturbed surfaces with cement mortor 1:3 and finishing to match with the existing surface and testing complete all as directed.
Supply and fixing sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4.0 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and wall thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down unserviceable one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6.0 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and wall thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
Supply and fixing MCB’s single pole 6 Amp to 30 Amp, 240 Volts,repurting capacity 10 K A complete all as specified and directed. Make:Sheineder/Legrand /L& /C&S
Supply and fixing MCB’s single pole and neutal 32 Amp to 40 Amp, 240 Volts,repurting capacity 10 K A complete all as specified and directed. Make:Sheineder/Legrand /L&T/C&S
Supplyi and fixing sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one singlle pole MCB of "C" series of capacity 16-32 Amp including taking out the unserviceable one all as specified and directed Make - Legrand / C&S/ Havells/L&Tr
Supply and fixing non return valves cast copper alloy ISI marked 15 mm dia including taking out the unserviceable one complete all as specified and directed.Make : Theta/DassPass/Racold
Supply and fixing pressure release valve of brass, inner threaded 15 mm dia including taking out the unserviceable one complete all as directed.Make : Theta/Dass Pass/Racold
Supply and fixing pressure release valve of brass outer threaded of 15 mm dia including taking out the unserviceable one complete all as directed.Make : Theta/Dass Pass/Racold
Supply and fixing heavy duty steel bedded PVC polythene connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer 02 Nos on each ends for Hot water including taking out the old one complete all as specified and directed make : Prayag or Poly tuff or equivalent.
Supply and fixing heavy duty steel bedded PVC polythene connection 15mm dia 450mm long with CP brass nuts and PVC washer complete for cold water complete including taking out the unserviceable one all as specified and directed make : Prayag/ Poly tuff.
Supply and fixing metal clad Industrial plug top ISI marked 2 pin with earth 240 Volts including taking down unserviceable one complete as specified and directed. Make – Havels/ Legrand /L&T
Supply and fixing metal clad Industrial socket ISI marked with earth 240 Volts including taking down unserviceable one complete as specified and directed. Make – Havels/ Legrand/L&T
Supply and fixing PVC insulated copper cable 3 core 40/ 0.0076, AC 1100/660 volt including taking down unserviceable one complete as specified and directed. Make-RR cables/ Havells / Plaza)
Supply and fixing metallicc fastener screw 75mm long 6mm dia with bolt for hanging Geyser complete all as specified and directed.
Material and labour for prepration of external surface storage type geyser of capacity 25 to 50 litres by comlete removal existing damage paint and applying two coats of synthetic enameled paint over a coat of red oxide primer including writing MES No with black paint complete all as specified and directed.
Material and labour for Galvanised tubing 15 mm bore medium grade ISI Marked fixed to walls and ceiling or laid in trenches/floor with all fitting and accessories complete all as specified and directed. Make : Jindal/Tata/Bansal/Nidhi
Supply and fixing cast copper alloy multifunction safety valve 15 mm dia ISI marked including taking out the unserviceable one ne complete all as specified and directed,Make : Theta/Dass Pass/Racold
Supply and fixing rubber gasket flange 25/50 ltr geyser including taking out the unseviceable one complete all as directed.
Supply and fixing 15 mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed including taking out old unserviceable one all as specified and as directed. Make : Theta/Dass Pass/Racold
Supply and fixing top plug 15 amps 3 pin, 240 Volts including taking out the unserviceable one complete all as specified and directed. Make: Havells/Plaza/Kinjal/SSK/standard
Material and labour for cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in foundation,filling and mass concrete complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down unserviceable one complete all as specified and directed. Make: Havells/Plaza/Kinjal/SSK/standard
Supply and fixing socket outlet, 2 in 1, 6 pin 5 & 15 Amp flush type conforming to IS 1293 ISI marked complete all as directed. Make: Havells/Plaza/Kinjal/SSK/standard
Supply and fixing switch sockst combination 2 in 1, 6 pin 5 & 15 Amps flush type universal , 240 Volts complete all as directed. Make: Havells/Plaza/Kinjal/SSK/standard
Shri Atoshe Tuccu
M/S NANDA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .