Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹26.7 L+₹3.4 L (14.7%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹27.0 L+₹3.7 L (15.9%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹33.0 L+₹9.7 L (41.7%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not found in order |
Tender Value
₹38.3 L
EMD Value
₹76,660
Closing Date
20 Dec 2022, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY EM EXTERNAL WATER SUPPLY AND ELECTRIALS COMPLAINTS AT TPT COY SP MARG SIGNAL COY RR COLONY NICHOLSON RANGE INCLUDING ATTENDING DAY TO DAY COMPLAINTS OF BORE WELLS AT RIDGE FOREST AND MISC WORKS IN AREA OF AGE U
2022_MES_565035_1
8222/GE/WS/Token-06/2022-23
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹76,660
Yes
6 Mar 2023
24 Nov 2022
22 Dec 2022
24 Nov 2022
20 Dec 2022
8 Dec 2022
Amount
Labour only for attending day to day external water supply complaints of all nature i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank,no water supply complaints received by users online/whatsaap through EIC/GE including noted down the complaints by rep/plumber/fitter appointed by contractor in writing in complaints register complete all as specified and as directed. (Any material required for attending complaints shall be measured and paid separately under respective item herein after) (Note :- (i) Quoted rates include notes mentioned at srl No 2.01 to 2.09) (ii) The suitable shift duties as deems fit shall be as per decision of the Engr-in-charge
Labour only for attending day to day electric supply complaints of day to day mantenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including nothing the complaints from Nodal Point No. I and allied areas in complaints register and distribution to the trademen complete all as directed (any meterial required for atteding complaints shall be measured & paid seperately under respective item here after) Note:- (i) The suitable shift duites as deems fit shall be as per decision of the Engr-in-charge (ii) Quoted rates include notes mentioned at srl No 2.01 to 2.09)
Notes for item No. 1.00 & 2.00 : (a) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate number of helpers complete all as specified and as directed
(b) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor repersentative shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complained
(c) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his repersentative. If Engineer -in-charge is satisfied with contractors view, no recovery will be made.
(d) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' . However no extra payments shall be made for dewatering/planking to trenches.
(e) Cutting of GI pipe in position and threading is also deemed to be included in the quoted unit rate of item No 1 & 2. (Fitting and fixtures will be measured and paid separetely under respective item of Sch A) as supply only.
(f) All T & P as well as dewatering motor single phase of 3HP with including 100 mtr cable, required for attending the complaints shall be provided by the contractor and provision to such aspects will deemed included under unit quoted rate.
(g) The pipe fitter shall always be in possession of die set complete with cutters , boring Tups , Pipe wrench, Chain wrench,Caulking tools, set of spanners and ladders,Vehicle/Ricksha etc Complete,all as required at site.
(h) The elecrician shall always be in possession of all Electrician tools, LT Megger, Earth tester, Multimeter, Crimping tool, insulation tape, Hand gloves etc complete all as required at site and directed by Engr-in-charge.
(j) Contractor shall be procured materials and deposited to concern JE/EIC store yard and after then all material as reqd at site for day to day maintenance shall be issued by Deptt under respective items(3,5,6,7,9,10,11,16&23) here in after:-
Supply only GI Socket Med Grade ,ISI marked of following Size:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply only GI Elbow Med Grade ,ISI marked of following Size:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply only GI Union Med Grade ,ISI marked of following Size:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply only GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply only PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and all as directed of following Size:-
Supply only GI Reducing socket medium grade ISI marked of following sizes
25 mmx15mm
20mmx15mm
25 mmx20 mm
50 mmx 40mm
Supply only GI solid plug heavy duty ISI marked of following sizes
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and laying tubing GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor including taking out existing as directed of following sizes :-
15mm bore
20mm bore
25mm bore
40 mm bore
50 mm bore
Materials required when work of pipe laying carried out at site following items in loose contents supplied by contractor:-
Supply only Lead pig bar
Supply only Spurn yarn
Supply only Lead wool
Supply only Nuts ,Bolts and Washers of 25 to 150 mm long of 6 to 20 mm dia complete.
Supply only PTMT Float valve with epoxy coated aluminium rod and high density HDPE ball of following sizes complete all as specified.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only gun metal gate/ball valve with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of following sizes complete all as specified.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Opening the existing Sluice Valve including opening of gland cover taking out with stem nut of brass or stainless steel & fitting the same after with & incluiding replacement of rubber packing, nut & bolts, glands doori, etc complete all as specified and directed of following sizes:- (Note :- Spare parts under relevant items shall be measured and paid separately under repsiective items)
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Supply only 'stem' made out from stainless steel of sluice valve of following sizes, complete all as specified and as directed.
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Supply only 'Stem Nut' made out from stainless steel suitable to match with existing sluice valve, sizes as under, complete all as specified and as directed..
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Supply only 'Gland Plate' made out from Cast iron suitable to match with existing sluice valve, sizes as under, complete all as specified and as directed.
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Taking up or down CI/DI Pipe of following sizes including all fittings) with spigot and socketed ends and lead tyton joints including burning out lead joints and recovering lead and including cleaning for refixing or removal complete all as specified and as directed:- Note:- Excavation & earth work shall be measured & paid separetely.
100 mm bore
150 mm bore
200 mm bore
Supplying, laying, jointing, testing and commmisioning DI Pipe of following sizes as per IS 8329-2000, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed:- (Note:- Joints shall be measured & paid separetely.)
100 mm bore
150 mm bore
200 mm bore
M&L rubber Gasket joint (Tyton joint) including jointing material for DI/CI pipe of following sizes, complete as specified:-
100 mm bore
150 mm bore
200 mm bore
Labour for cutting of existing CI / DI pipe for insertion of CI specials etc. all as required including dewatering of lekage water all as required of the following size complete all as specified and as directed .
100 mm bore
150 mm bore
200 mm bore
Supply only of DI/CI MJ collar required in fixed in repair of the following sizes:-
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
400 mm bore
Supply and fixing in replacement of GM ball valve of sizes 12 mm dia bore including coolling pipe with check nuts, suitable length of GI nipples etc complete for Centrifugal Pump Sets complete all as specified and directed.
Supply and fixing in replacement Pressure gauge of suitable pressure upto 14 Kgs/cum all as existing including necessary fitting, complete all as specified and directed.
Testing of drinking water being collected from local source (Pump House, bore wells /shallow wells of Nodal Point No.I pocket under AGE(U) W/S No.III and submission for detailed testing to the test lab and test report will be submitted to the office of Engr-in-Charge.
Testing of STP treated/untreated water being collected from local source of pocket under AGE(U) W/S No.III and submission for detailed testing to the test lab and test report will be submitted to the office of Engr-in-Charge.
Note for item 25 & 26 :- (a) Collection of water from[ different sources of water ie. Pump House, Sump, bore wells & shallow well/STP in a sterilized bottle and testing in GOVT Approved laboratory as mentioned in specification (b ) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, tubidity, PH valve TDS total hardness iron, chloride, fluride and residual free chlorine and Bacteriological total coil from organisms per 100 ml (MPN) and E coli in 100 ml) to this office with specific recommendation regarding suitability of water for drinking purpose & supply of water for domestic uses. (c) STP Water Parameters shall include of testing of PH, BOD, COD, Suspended Solids, Ammonical nitrogen, Total nitrogen, Fecal Coliform etc and test report will be submitted to EIC duly vetted by Govt approved Lab authority. (d) Rate Quoted shall be deemed to included for cost of sterilized bottle as required and transportation charges for collection of samples from source (sump, bore & shallow wells) and submission to Engineer-in-Charge in sealed container for signature of JE E/M & Engineer-in-Charge.
Electrical items :- Electrical items required during repair/ maintenance of installation/pump houses etc and labour element shall be deemed included under quoted unit rate under Ser Item No 2 above and accordingly measured and paid supply only as following:-
Switch Piano flush type 5 amps single pole one way 240 volt complete
Switch Piano flush type 15 amps single pole one way 240 volt complete
Socket 2 in 1 3/5 pin 5 amp 240 volt complete
Socket 2 in 1 3/5 pin 15 amp 240 volt complete
LED bulb 14/20 Watt 240 Volts complete
PVC insulation tape role of length 10 M (white) complete
PVC adhisive tape role of length 10 M (white) complete
PVC insulated multistranded copper conductor cable of size 1.5 sqmm, single core 1100 volt grade complete
PVC inslulated multistranded copper conductor cable of size 2.5 Sqmm, single core, 1100 volts grade complete
Lamp holder PVC/Polycarbonate type with back plate suitable batten fitting complete
Ceiling rose 3 terminal PVC/Polycarbonate of 50mm size isolated body 230 volt complete
Supply and fixing in repair copper terminals lugs (Thimbles) ring type medium duty for following sizes :-
Supply and fixing in repair Aluminium terminals lugs (Thimbles) ring type medium duty for following sizes :-
Supply & filling of sand free from dust and vegetations in cable ducts/ trenches with and including removing old sand to a distance not exceeding 50 mtr away and depositing where directed by Engineer-in-charge. (Note :- Punned depth shall be measured and paid).
Supply and fixing in repair connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 60 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed
Supply and fixing in replacement connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 45 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed
Supply and fixing in replacement of LED tube light fitting of 20/22/2 Watt complete with taking out and suitable length of flexible wire of suitable length complete all as specified and directed by Engr-in-charg.
M&L for repair overhauling of Water Level Indicator (mechanical type) installed at semi under ground water reserviors including providing greasing the pully, including adjustment of steel rope/float ball for its proper calibration and replacement of existing unserviceable nut and bolt, pully, float ball and steel rope making functional for its smooth effecient functioning complete all as specified and directed. (Note:- Float ball and steel rope shall be measured and paid for seperately).
Suply and fixing in replacement of Brass ball of size 300 mm bore complete with suitable size 'U' clamps for manual water level indicator coplete all as specified and as directed
Surface excavation not exceeding 30 cm deep averaging 15 cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installation/around the valve pit chamber/along the pipe line routes etc and getting out soft/loose soil complete all as specified and as directed.
Supplying and fixing three core poly tetra flouro ethylene teflon silcer plated copper wire shielded temp range 40 degree to 240 degree, size 0.25 Sqmm (24/7/32) after taking down/out as existing at site complete all as specified and as directed.
Supply, Installation, Testing, and Commissioning of a set of maintenance free earthing system consisting 2 nos. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper busbar of 150mm x 50mm x 6mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriters laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed, Resisitivity of the earth enhancing compond should be less than 0.05 ohm and required as per international standard for Earth Enhancement Compound approved by NABL accredited Lab including dismentling of existing earth pit complete all as specified & directed.
Notes: (i) Quoted unit rate for interconnection of earth set with Copper strip of size 20mm x 3mm of required length as per site and not less than 7.5Rm from test point and polycarbonate earth pit cover-02 Nos, shall be deemed included. (ii) Earth test report and maintenance gurantee of earthing and manufacturers test report shall be submitted by contractor alongwih approved drgsduly signed to EIC for approval.
M&L earth continuity conductor or main earthing lead on FRP/PVC/Ceramic insulator fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper strip 20mm x 3mm complete all as specified & directed
M&L test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed with and including 3 nos, 8mm dia, 25mm long hexagonal head screw, drilled with and including connecting of copper strip of both ends, and bronze/copper nuts, bolts and washers of suitable size complete all as specified & directed.
Supply and laying of rubber insulated mat of size 2.00 mtr x 1.00 mtr of 19 mm thick ISI marked complete all as specified and as directed by Engr-in-charage.
Supply and fixing rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tanks, cylindrical vertical with closed top, 1000 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed.
M&L of stainless steel works of gradese-304 any shape/sizes of angles irons/flat iron/MS sheet/circuler etc including necessary cutting and welding, works, and writing works (s.s. sheet) of suitable size of writting complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed by the Engineer-in-charge.
Removing excavated material from site to a distance not exc 50 away and depositing where directed not exc 1.5 meters from the starting point all as directed by Engineer-in-charge.
Supply and fixing steel rope stranded(flexible) 3 mm dia complete all as specified and directed(as per sample).
M&L for MS works of any sizes of angles irons/flat iron/MS sheet works for U/S Sumps for making grills and stair steps etc. complete
S&F of Wire mesh (expanded metal) jalli XPM metal weight not less than 4kg/sqm complete all as specified and directed.
M&L for painting of existing Steel/RCC surface with two coat of Black/Blue colour synthetic enamelled paint including preparation of surfaces complete.
M&L for writing letter or figures Block, Roman, Italic or Indian) exc 20cm but not exc 30cm high and width exc. 5cm but not exc. 10cm and letter shall be painted with 2mm thick synthetic enamel paint so that they stand out boldly and solidly without showing signs or brush mark complete all as specified and directed.
M&L for painting with two coats of supper enamelled paint with one coat of primer on Pump set including electric driven motor, coupling, base frame, sluice valve, NRV etc of capacity upto 75 HP complete with all as specified and as directed by Engineer-in-charge.
M&L for Painting with two coats of supper enamelled paint with of Pump set including electric driven motor, coupling, base frame, sluice valve, NRV etc of capacity 200 HP complete with all as specified and as directed by Engineer-in-charge.
M & L for painting of Sluice Vlave, NRV, upto 150 mm bore with two coats of supper enamelled paint over a coat of primer including preperation of old surface complete all as specified and as directed by Engineer-in-charge.
M & L for painting of Sluice Vlave, NRV, upto 450 mm bore with two coats of supper enamelled paint over one coat of primer including preperation of old surface complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of air vent pipe of size 150 mm bore UPVC pipe 10 kgs/cum pressure heavy duty of length 0.30 mtr long and 2 nos of UPVC bend of semi under ground reservoir any capacity including necessay PCC complete all as specified and as directed by Engineer-in-charge.
M & L Construction of valves pit chamber having intermal dimension 120 cm x 120 cm x 120 cm (internal height) using PCC (1:4:8) 40mm graded stone aggregate for foundation 15 cms, thick, 23 cm thick wall in CM (1:4), 10mm thick rendering all around the brick work in cm 1:6, PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm tick MS top sheet cover with locking arrangement including 50mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation & earth work in any type of soil, returning filling in and removal of surpuls soil to a distance not exceeding 50 mtrs all as specified and shwn on drg No CWE (U)/D-1/86 sheet No 1/1 and includung demolition/ dismentling of existing valve chamber complete all as specified and as directed.
M & L Construction of valves pit chamber having internal dismension 2.20 m x 1.80 m x1.50 m (internal height) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4), 10 mm thick rendering all around the brick work with cement mortar (1:6), PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm thick MS top sheet cover in 2 pieces with locking arrangement including 50 mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation & earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as specified and shown on drg No CWE (U)/D-1/86 sheet No 1/1 and including demolition/dismentling of existing vave chamber complete all as specified and as directed
Note:- Sch of credit amount of Rs. 112197.50/- shall be deducted from total quoted BOQ Amount when work acceptance letter issued.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .