Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.2 L+₹34,577 (1.12%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹33.3 L+₹2.4 L (7.83%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹33.9 L+₹3.0 L (9.84%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹35.5 L+₹4.6 L (14.8%)Rejected-Finance 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin - 305601
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY INSTALLATION, PANEL MCCB, FEEDER PILLER AND CABLE AT NASIRABAD MIL STATION AND REPAIR/MAINT AND UPKEEPING OF ALL E/M ELECTRIC AND WATER SUPPLY INSTALLATIONS AT AJMER AND NASIRABAD MIL STN UNDER GE NASIRABAD
2024_MES_641167_1
8427/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category b(i) having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹80,000
Yes
12 Mar 2024
7 Feb 2024
11 Mar 2024
7 Feb 2024
9 Mar 2024
21 Feb 2024
7 Feb 2024 - 21 Feb 2024
Amount
Dismantling cable protection pipe 40/50/80 mm dia complete all as specified and directed.
Taking out old unserviceable UG cable of any size and core complete all as specified and directed.
Disconnecting and taking out old existing unserviceable LT under ground cable of any description, cross sectional area and in any position from trenches/ under floor,roads,paths or from walls / from poles/ from ducts etc. complete all as specified and directed
Taking out old unserviceble pipe 80/ 100 mm dia complete all as specified and directed.
Supply, Laying, testing of XLPE cable armoured, in trenches or fixed to wall/pole or passing through pipe cable LT, electric power cable(heavy duty) 1100 volts grade with multistandard stranded aluminium conductor of size of following, complete all as specified and directed by Engr-in Charge :-
All as per the item No 5.00 above but size 6 Sqmm 2 core
All as per the item No 5.00 above but size 400 Sqmm 3.5 core
All as per the item No 5.00 above but size 240 Sqmm 3.5 core
All as per the item No 5.00 above but size 120 Sqmm 3.5 core
All as per the item No 5.00 above but size 70 Sqmm 3.5 core
All as per the item No 5.00 above but size 50 Sqmm 3.5 core
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard and dense soil and getting out all as specified and directed at site by Engr-in Charge.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed.
Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge.
Supply and lay in trenches, un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed by Engineer-in-charge Note:-Punned thickness only shall be measured and paid.
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-charge.
M & L for carryout boring under the black top road by mechanical boring machine and providing hole of 80/100 mm dia (min) for suitable to fix the GI pipe 80/100 mm under the road complete all as specified and directed.
Supplying and fixing light grade , Galvanised mild steel pipe / tubing, complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete for cable proction all as specified and directed of following sizes:-. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ):-
All as per the item No 13.00 above but 100 mm bore
All as per the item No 13.00 above but 80 mm bore
M&L for horizontal holes under roads/ pavements/ hard standing etc. at a depth as directed but not less than 1.00 m below existing Ground level, of suitable dia to accomodate pipes upto 100 mm dia , by any means for horizontal boring for passing of cable etc. complete all as specified & directed.
S&F light grade 40mm GI pipe fix complete to Wall, ceiling, Poles etc with suitable clamp for protection of cable complete all as specified and directed
All as per item No 15.00 above but size 80mm GI pipe
M&L in repair for earthing complete with galvanised steel earth plate electrode Chemical earthing using copper plate 60×60cm ×3.15mm thick electrode, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed
M&L in repair for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed
S&F cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type straight through joint kitcomplete with jointing material and accessories suitable for 4 core XLPE armoured Aluminium conductor cable of size 25-50 sqmm complete all as specified and directed. Make: L&T
S&F cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type straight through joint kitcomplete with jointing material and accessories suitable for 4 core XLPE armoured Aluminium conductor cable of size 70-120 sqmm complete all as specified and directed. Make: L&T
S&F in repairs of contactor MNX 95, 2 NO + 2 NC for panel complete all as specified and directed. Make: L&T
S&F in repairs of contactor MNX 70, 2 NO + 2 NC for panel complete all as specified and directed. Make: L&T
S&F in repairs of contactor MNX A1 4 Poles for panel complete all as specified and directed. Make: L&T
S&F in repairs of Cylindrical fuse links HRC Type HF of capacity 40Amp for panel complete all as specified and directed. Make: L&T
S&F in repairs of Cylindrical fuse links HRC Bolted fuse links Type A3 capacity 63Amp for panel complete all as specified and directed. Make: L&T
Taking down old unsv post top lantern and Supply & fixing 20 watt with IP 65 Protection decorative LED Post top lantern after taking down old one complete all as specified and directed.
Taking down existing flood light fitting any type and Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.with all fixing arangement, nuts, bolts and washer connecting to electric system with 1.5 sqmm PVC copper stranded conductor 2/3 core as required length from light fitting to street light control box /control Switch on pole/Panel/Timer, testing on completion, complete all as specified and directed. MAKE: Havells Cat Part No JETAIRISFL120WLED757ARWBLTG or equivalent Crompton Pluto Neo 120W Warm White Flood Lighting, LFLN-120-CDL/60-M
Notes: for The Item No 27.00 to 33.00 below should be comprises with thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range as per manufacture capacity, Amp including spreader terminals and phase barriers including all as specified and directed.
S&F for MCCB, 415 Volts, 4 pole, adjustable type, 400 Amp, breaking capacity 36 KA as per site requirement on existing LT panel board complete all as specified and as directed . Make :- Havells/L & T/LEGRAND
S&F for MCCB, 415 Volts, 4 pole, adjustable type, 200 Amp, breaking capacity 36 KA as per site requirement on existing LT panel board complete all as specified and as directed . Make :- Havells/L & T/LEGRAND
S&F for MCCB, AC, 415 Volts, 4 pole adjustable type, 250 Amps, breaking capacity 36 KA as per site requirement on existing LT panel board complete all as specified and as directed . Make :- Havells/L & T/LEGRAND
S&F for MCCB, 415 Volts, 4 pole, adjustable type, 160 Amp, breaking capacity 36 KA on existing LT panel board complete all as specified and as directed. Make :- Havells/L & T/LEGRAND
S&F for MCCB, AC, 415 Volts, 4 pole, adjustable type, 100 Amp, breaking capacity 16 KA on existing LT panel board complete all as specified and as directed. Make :- Havells/L & T/LEGRAND
S&F for MCCB, AC, 415 Volts, 4 pole, adjustable type, 63 Amp, breaking capacity 16 KA on existing LT panel board complete all as specified and as directed. Make :- Havells/L & T/LEGRAND
S&F for MCCB, AC, 415 Volts, 4 pole, adjustable type, 25 Amp, breaking capacity 16 KA on existing LT panel board complete all as specified and as directed. Make :- Havells/L & T/LEGRAND
S & F in replacement of 1100 Volts grade Cable with 25 sqmm single core copper conductor PVC round sheathed (flexible) industrial cable complete all as specified & directed.
S & F in Aluminium lugs thimple/bottle type of following size including taking down old one complete all as specified & directed :-
All as per item No 36.00 above but size 240 sqmm
All as per item No 36.00 above but size 70 sqmm
All as per item No 36.00 above but size 95 sqmm
All as per item No 36.00 above but size 50 sqmm
All as per item No 36.00 above but size 25 sqmm
S&F in replacement of damaged LT panel section of front/back/side /top and bottom portion of any size MS sheet with new of required size or thickness and fixing on existing LT panel board including necessary bracing/welding work and drilling works including necessary hinges and two coat of synthetic thick enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in Charge.
S & F framed work as in doors or gates of angle made out of Fe 410-W Gde E-250 quality -A or other section with gusset plates, rails, hooks, hinges for sliding arrangement, etc., complete all as specified and as directed by Engr-in Charge.
Cleaning and upkeeping of sub station area, surrounding area of LT Panel/Bus Bar/Feeder pillar box and clearing away all grass vegetation, sapplings,shrubs,bushes under growth roots and trees not exc 30 cm girth ( Measured 1 mtr above the ground level) and removing of rubbish to a distance of 50 mtr out side periphary complete all as specified and directed by Engr-in Charge.
M&L for painting feeder pillar box/LT panels of inside, outside and all six sides including all angle iron legs after preparation of old painted surfaces with one coat of synthetic enamel paint of existing colour complete all as specified & directed by Engr-in Charge.
Supply, install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer complete all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories
Cleaning and upkeeping of sub station area,all power houses ,water supply installations including in Ajmer surrounding area of LT Panel/Bus Bar/Feeder pillar box and clearing away all grass vegetation, sapplings,shrubs,bushes under growth roots and trees not exc 30 cm girth ( Measured 1 mtr above the ground level) and removing of rubbish to a distance of 50 mtr out side periphary complete all as specified and directed by Engr-in Charge.
M & L for taking out sludge /foreign material/silt/vegetation /mud from the clear water underground sump of following capacity dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfection material after repairing cracks/depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/best quality putty after applying cement slurry mixed with liquid water proofing admixture to entire satisfaction of Engr-in-Charge preparation of old surface and applying one coat of lime wash in inner surface including removing the sludge/slit/foreign material by using suitable T&P/man power to a distance 50 to 100 meters and depositing where directed as and when required basis and writing date of cleaning with paint capital letter of 80mm stencil alongwith the capacity of the tank.complete all as specified and directed by Engr-in-Charge
All as per item No 43.00 above but Under Ground Sump Capacity 4,37,000 Gallons
All as per item No 43.00 above but Under Ground Sump Capacity 3,00,000 Gallons
All as per item No 43.00 above but Under Ground Sump Capacity 20,000 Gallons
S&F of AFO Fireball-Fire Extinguisher Plastic Ball Oval Shaped ,Quick Fire off, 1.5 kg dimensions 22 x 22 x 22 cm complete all as specified and directed by Engr-in-Charge
S&F in repairs installation, connecting, commissioning and testing of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 600 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel, Make of CT - AE, CT Ratio:250/5 Amp
S&F in repairs installation, connecting, commissioning and testing of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 600 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel, Make of CT - AE, CT Ratio:600/5 Amp
Notes:(For item No 45.00 to 46.00):- (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (ii) Make of MCCB :-HPL/HAVELLS (iii) Make :-Universal (iv) Make of Voltmeter, Ammeter:- L&T (v) Danger notice plate (02 Nos)in Hindi and English of size 20cmx 15cm shall be fixed on the panel (vi) Contractor provided power coated finish paint on panel and test certificate /CPRI Approval certificate.
KAVYA ENTERPRISES
Nvimal Engineers and Contractor
M/s SUNIL ENTERPRISES
SHREE BALAJI TRADING CORPORATION
PD GUPTA AND COMPANY
DEMROT ELECTRICAL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .