Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.3 LAccepted-AOC RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹61.7 L+₹2.4 L (3.97%)Rejected-Finance | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹65.0 L+₹5.6 L (9.50%)Rejected-Finance C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹65.2 L+₹5.8 L (9.84%)Rejected-Finance C O SIMPLICITY LYNGDOH LOWER LUMPARING LABAN SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L4 | Rejected-Finance Other than L1 bidder | |
| 5 | L5₹77.4 L+₹18.0 L (30.3%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹72 L
EMD Value
₹1.3 L
Closing Date
8 Nov 2022, 6:00 pmClosed
CWE Shillong
CWE Shillong, SE Falls, Shillong - 793011
SPL REPAIR TO ELECTRIC WIRING, ROOF, LEAKAGE AND BATHROOM OF BLDG NO. P-37 (OTM) AT UMROI MIL STN UNDER GE UMROI
2022_MES_554261_1
8602/UMR/E8
Open Tender
Civil Works
Item Rate
180 days
GE Umroi
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Umroi
₹1.3 L
Yes
19 Dec 2022
27 Sept 2022
9 Nov 2022
27 Sept 2022
8 Nov 2022
18 Oct 2022
Amount
Dismantling AC/GI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including ridges and make good for aluminium earthing strips after fixing of sheets complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed.
Supply and fix pre- painted galvalume aluminum zinc coating PPGL based corrugated/Trapezoidal steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall eave board, fixed with self tapping screws complete all as specified and directed.
Supply and fix half round colour coated UPVC gutter/runner drop for rain water drain in bldgs of size not exceeding 150 mm with firmly attached downpout of suitable size discharging storm water into PVC SWR pipe of 110 mm dia and similar works etc complete all as specified and directed. Note: The rate shall be inclusive of down spout, drop outlet, elbows, end cap, straight connecter, brackets, downspout couple, splash block, out site corner, clamps as required at site as per standared engineering practice and directed.
Supply and fix 0.63 mm thick plain, galvanised, mild steel sheeting in valley gutter, crumple joint and similar work with grade of zinc coating @ 275 gm/sqm etc complete all as specified and directed.
Taking down eaves gutter and rain water pipe (any size or pattern), including all fittings, head, shoe, bend, swan neck, etc, including cleaning or refixing or removal to store complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed.
Demolition of reinforced cement concrete of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and directed.
Material and labour for 25mm thick (average thickness) PCC 1:2:4 type B-0, 12.5mm graded stone aggregate finishing cement concrete surface even and fair using extra cement all as specified and directed.
Supply and fix rotational moulded polyethene water storage tanks 1000 lit capacity with lid (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I, including dismantling water tanks and removing to store complete all as specified and directed.
Supply and fix in repair 20mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.
Supply and fix in repair 20 mm bore Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm?45gms /25mm- 6) complete all as specified and directed.
Supply and fix 20 mm bore ball brass valve, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed.
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
Material and labour for complete removal of loose/ cracked concrete including reinforcement if required from RCC roof projection, chajja, fins, facia etc and making good with PCC (1:1.5:3) type A0 using 12.5 mm graded aggregate) in any slab and in any position finsihed the surface even and smooth with out using extra cement including necesary formwork and weldign/binding of reinforcement (including reinforcement) if required complete all as specified and directed. Note: Reinforcement will be measured and paid seperately under respective items.
Material and labour for TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Material and labour for welded steel wire fabric n. exc. 4 Kg/Sqm supplied and fixed, complete to wood and steel member and over plastering in CM 1:4 average 20 mm thick including water proofing compound as per manufacturer instructions, finishied even and fair using extra cement to level the surface etc of over head tanks/UG Sumps where required complete all as specified and directed.
Supply and fix in repair 20mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in repair complete all as specified and as directed.
Taking up or down steel tubing and conncection 25 mm including cleaning for re-fixing or removal to store all specified and directed.
Supply and fix CPVC pipes outer diameter 20mm SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floor complete all as specified and directed.
Taking up or down steel tubing and conncection 20mm, including cleaning for re-fixing or removal to store complete all as specified and as directed.
Supplying and laying of CPVC pipes outer diameter 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Taking up or down steel tubing and conncection 15mm, including cleaning for re-fixing or removal to store complete all as specified and as directed.
Supplying and laying of CPVC pipes outer diameter 16 mm SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified and directed.
Supply and fix aluminium powder coated [Minimum 50 Micron thick] anodised aluminium sliding frame and shutter for windows/ventilation with 92 mm x 31.75 mm x 1.5 mm thick three track section for frames and 40 x 18 x 1.55 mm thick sliding section for shutters of both gauzed and glazed with 4 mm thick tinted glass, aluminium Deco Grill of Model / Design No. DG 104 and stainless steel wire cloth [0.63 mm nominal dia and avg width of aperture 1.40 mm] including necessary jointed, cleats powder coated glazzing clips, powder coated aluminium snap beadings, screw and aluminium fittings, suitable handle cum complete and as specified and directed.
Material and labour for preparing old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enemal paint complete all as specified and as directed.
Taking down cement plaster of any description including racking out joints for key scrubing with water etc. complete all as specified and directed.
Material and labour for 15mm thick rendering in CM (1:4) in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and directed.
Supply only integral WPC ( Integral waterproofing liquid admixture for plaster mortar) all as specified and directed.
Material and labour for rendering 10mm thick in cement mortar (1:6) on brick or concrete surface finished even and fair without using extra cement complete all as specified and directed
Material and labour for 5 mm thick rendering in cement mortar (1:3) on fair faces of concrete surfaces such as soffits of slabs, in patches n exc 1 sqm each finishing the surfaces fair and even complete all as specified and directed.
Material and Labour for complete removal of existing old treatment of wall and applying a layer of 1.5mm thick wall care putty and two coats of oil bound distemper over a coat of alkali resistant primer including preparation of surface complete all as specified and directed.
Material and labour for complete removal of existing old treatment of wall and applying 1.5mm thick wall care putty and two coat of weather proof exterior emulation (APEX of Asian paint or equivalent)including preparation of old decorative surfaces of walls, washing rubbing down and stopping of distempered and painted surfaces complete all as specified and directed. Note- 1) All painting will be done through mechanical process (Spray Painting) masking and cleaning of floor, door, window etc during spray painting. 2) The rate shall be inclusive of scaffolding
Material and labour for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over wall care putty minimum 1.5 mm thick and a coat of alkali resistant primer, complete all as specified and as directed.
Material and labour for applying two coats of exterior weather coat paint over coat of alkali resistant primer complete all as specified and directed.
Material and labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of new surafaces complete all as specified and directed.
Material and labour for preparation of old decorated plastered surfaces of ceiling surfaces complete all as specified and directed.
Dismantling and breaking up drain pipes AC /CI /PVC Pipes set in cement mortar 100mm/75mm bore complete.
Supply and fix PVC (SWR) pipes single socketed in any length with rubberring joints fixed to wall with clamp 110mm bore, complete all as specified and directed.
Supply and fix PVC (SWR) bend any radius 110mm bore, complete all as specified and directed.
Supply and fix PVC (SWR) single T equal or unequal with access door 110mm bore, complete all as specified and directed.
Dismantling wall and ceiling board any thickness including cover fillet complete all as directed.
Material and labour for false ceiling of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 2 mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 2 mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, complete all as specified and directed.
Material and labour for 20 mm thick second class soft wood boarding fixed with nails in any situation and planed one side as in eave board, on facia, barge, soffit etc complete all as specified and as directed.
Material and labour for preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enemal paint over one coat of pink primer complete all as specified and directed.
Material and labour for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 with suitable holdfasts/rawl plugs all as specified and directed.
Demolition of cement concrete above ground floor and pavings exc 15 cm thickness (below or above ground level ) unreinforced complete all as specified and directed.
Material and labour for sunken treatment of Toilet/Bathroom as in following steps: i) Top of RCC slab in sunken portion including peripheral beams shall be plastered with 15mm thick in cement mortar 1 : 3 using approved water proofing compound @ 3% by weight of cement finished even and smooth using extra cement, curved at the junctions. ii) Apply two coats of epoxy resin/polymer modified cementations coating like brush bond of FOSROK/SIKA/Pedilite or equivalent, both on floor & beams. iii) Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyond outer surface of wall shall be provided. iv) Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab. v) The sunken portion will be filled with lean concrete 1:4:8 type D2 using brick aggregates to required depth. Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings. The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE.
Removing demolished material upto a distance exceeding 250m but not exceeding 500m including loading/unloading and spreading if required and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Material and labour for coloured non skid ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and directed.
Material and labour for glazed ceramic coloured /printed tiles 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match on verticle surface of wall complete all as specified and as directed.
Material and labour for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.18 sqm but n exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Material and labour for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.18 sqm but n exc 0.38 sqm, in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed.
Material and labour for screed bed or bedding laying of cement mortar (1:4) 15 mm thick for as in floor finishes, complete all as specified and as directed.
Material and labour for backing coat of cement mortar 1:4 10 mm thick for as in vertical surfaces such as skirting , dados etc, complete all as specified and as directed.
Supply and fix in repair 15mm bore bib tap cast copper alloy chromium plated fancy type with crunch or butterfly handle screw down scrwed for iron piupe or for brass funnel and fixed, in repair complete all as specified and as directed.
Supply and fix in repair 15 mm Stop valve, fancy type,chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair, complete all as specified and as directed.
Supply and fix in repair shower rose CP fix to iron pipe 15mm all as specified and directed.
Material and labour for 75mm PVC (SWR) floor trap, with grating including jointing with solvent cement,complete all as specified and directed.
Supply and fix in repair brass chromium plated tubular towel rail , 20mm dia , 60cm long between flanges complete all as specified and as directed.
Supply and fix in repair PVC low level flushing cistern , white , 10 ltrs capacity with float valve and brackets complete including fixing low level flush pipe after dismantling of old unserviceable existing flushing cistern complete all as specified and directed.
Supply and fix vitreous china wash hand basin size 550x400mm (flat back or angle back type) including 32mm dia brass chromium plated waste fitting a pair if cast iron bracket duly painted /erecting stand including cutting and pinning in ends making good disturbed surfaces in CM 1:3 including taking down unserviceable wash hand basin and connected items of any description, complete all as specified and as directed.
Supply and fix in repair 15mm bore dia pillar tap, fancy type chromium plated with capstan heads chromium plated screwed down high pressure, with or without lettered 'hotor cold' with long screwed shank and fly nuts screw for iron pipe all as specified and directed.
Supply and fix 40 mm low density polyethylene (LDPE) pipes complete all as specified and directed.
Supply and fix in repair vitreous china urinal half stall type white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement fixing only flushing cistern with brackets including waste pipe etc. all as specified and directed.
Supply and fix PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Supply and fix in repair vitreous china 580x440 mm,"ORISSA PATTERN" with 'P' or 'S' trap size squatting pan (Exclusive flushing cistern and flush pipe) incl foot rest complete and provision of lime concrete bedding all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) but area n.exc. 1.5 Sqm each and removing from site all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.5 Sqm but n.exc.4 Sqm each all as specified and directed.
Taking down shutter of any description exceeding 1Sqm but not exceeding 2Sqm each and removing from site all as specified and directed.
Supply and fix factory made solid PVC moulded door shutter, with particle board core, 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm prelam PVC sheet on back face, fixing in frame at site as per specification & drawing, complete all as specified and directed.
Supply and fix factory made Solid PVC Double door frame of size 50mm x 95mm single side prelam PVC sheet used instead of Plain colour PVC sheet, reinforced with M.S. tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
Supply and fix extruded aluminium alloy handle, fabricated type, anodised, 150mm, complete all as specified and directed.
Supply and fix 150 mm long aluminium anodised barrel tower bolt complete all as specified and as directed.
Supply and fix butt hinge 100mm long (type C 21) extruded aluminium alloy, complete all as specified and directed.
Supply and fix in repair grating doom 100mm dia of PTMT (Minimum weight 25gms) all as specified and directed.
Supply and fix in repair stainless steel anodised curtain rod of approved colour and design, with fixing bracket, stop, roller (approved by Eng-in Charge) etc.complete all as specified and as directed.
Supply and fix pressed steel door frame 105 x 60mm with one or more rebated including necessary fixing lug hinge, lock strick , etc complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in filling of pressed steel frame complete all as specified and as directed.
Supply and fix 32 mm thick waterproofing and fire proofing flush door shutter, solid core construction, with particle board core and plywood face panel, commercial type on both sides both face is covered with decorative face veneer with lipping/frame to match all as specified and directed.
Supply and fix 100 mm long medium weight, cold rolled mild steel nutt hinge complete all as specified and directed.
Supply and fix 150mm aluminum anodised bow handle complete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast Aluminium alloy complete all as specified and directed.
Material and labour for painting to steel surfaces of any description, over 10cm in width or grith with two coat of synthetic enamel paint over a coat of red oxide, not otherwise described.
Taking down carefully old unserviceable copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switche, ceiling rose, pendant, regulator, socket, etc. to be measured separately) and removing materials to store for keeping in safe custody for re-use at site or for taking credit and making good to disturbed surface of wall, floor etc with its original specification complete all as specified and directed.
Taking down carefully MCB DBs SP/TP by unscrewing from main switch board /cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable end and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
Material and labour for point wiring for the followings with 1.5 Sqmm single core, PVC FRLS insulated unsheathed, multistranded copper conductor drawn through and including PVC concealed including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLS insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed as below :- Note:- Rate for uutting, chieseling and making good the existing surface for complete concealed wiring is deemed to be included in quoted rate all as specified & directed.
One light/fan point controlled by one,one way switch.
One 3 Pin 5 Amps socket out let point on independent board.
One 3 Pin 5 Amps socket out let point on same board alongwith other suitable switch.
One light point controlled by two, two way switch.
All as per item No 90.00 here-in-before but using 2.5 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board complete all as specified and directed.
Supply and fix of switch piano flush type 240 Volts 5 Amps, SP, one way with white colour complete all as specifed and directed.
Supply and fix of switch piano flush type 240 Volts 5 Amps, SP, two way complete all as specifed and directed.
Supply and fix of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) with white colour complete all as specified and directed.
Supply and fix of socket 3 pin 5 Amps 240 Volts flush type (non shuttered) with white colour complete all as specified and directed.
Supply and fix switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) with white colour complete all as specified and directed.
Supply and fix ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified and directed.
Supply and fix ceiling fan regulator electronic,Deluxe,rotary, step type, 120/280 V complete all as specified and directed.
Supply and fix of vertical TPN DB double door 08 way suitable for MCCB 140A as incomer conforms to IS 8623-1 & 3, IEC 61439-1 & 3, IP : 43 protection, powder coated CRCA sheet steel isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed. Note: MCCB incomer and MCB outgoing to be measured and paid in seperatelly item complete all as specified and directed.
Supply and fix of 140 A MCCB 4 pole 18KA incomer conforms to IS/IEC 60947-2 & IEC 60947-2,415 volts complete all as specified and directed.
Supply and fix of MCB SP 40 Amps 'B' Series 10 Ka,240 volts complete all as specified and directed.
Supply and fix in of MCB SPN DB 8 way double door,IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed.
Supply and fix of MCB SPN 32 Amps 'B' Series 10 KA, 240 volts complete all as specified and directed.
Supply and fix of MCB SP 6 to 20 Amps 'B' Series 10 KA, 240 volts complete all as specified and directed.
Supply and fix bulb holder angular PVC/Polycarbonate suitable for batten fittings complete all as specified and directed.
Supply and fix LED fitting 1x18 watt including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round/Squre block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded stone aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.
Taking down aluminium submain wire along with damaged casing caping /PVC conduit pipe from the wall roof or floor and making good distrubed surface complet all as specified and directed.
Material and labour for Sub main wiring with two runs of single core, FRLSH 6 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi-standed copper conductor cable LT 1100 volts grade drawn thorugh PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 Sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring two run of 6 Sqmm cable one run of casing capping and one run of 6 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.
Supply and fix PVC blanking plate, one model sutable for MCB DB complete all as specified and directed.
Supply and fix LED bulb of 9 Watt (Warm white) complete all as specified and directed.
Supply and fix LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years of capacity 30W complete all as specified and directed.
Supply and fix 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unsv / fully rusted existing unserviceable one complete all as specified and directed.
Taking down carefully and refixing of old existing any size/type of ceilng fan with complete accessories all as specified and directed.
Taking down carefully and refixing of old existing any size/type of exhaust fan with complete accessories all as specified and directed.
Supply and fix ceiling fan 1200 mm (minimum) sweep, BEE 5 star rated with BLDC technology, AC single phase 230 watt, including smart remote with long lasting battery to control speed, multipairing, timer and other intelligent memory functions, suspected from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling fan complete all as specified and directed. Note:- Old ceiling fans shall be deposited to MES store.
M/S N K associates
M/S UTTAM SAHA
Lyngdohs Construction Company And Associates
Ms N D Enterpise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .