Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹28.5 L+₹64,327.50 (2.31%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹29.4 L+₹1.5 L (5.52%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹29.8 L+₹1.9 L (6.71%)Rejected-AOC 00 00 BAIRIYA NEAR KALI MAA MANDIR BALLIA UTTAR PRADESH 277502 | BALLIA | UTTAR PRADESH | 277502 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹31.9 L+₹4.0 L (14.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repairs to roof of permanent and temp Building at AOR AGE B/R II under GE(N) Ahmednagar
2023_MES_591783_1
8742 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer North Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer(North) Ahmednagar
₹70,000
Yes
16 Jun 2023
28 Apr 2023
27 May 2023
28 Apr 2023
25 May 2023
11 May 2023
Amount
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided etc complete all as specified and directed by Engineer-in-Charge.
M&L for providing water proofing treatment on roofs, as per manufacturer's instructions and as specified after taking down/out as existing tar felt at site :- (a) Cleaning the newly plastered surfaces with wire brushes and applying a coat of bituminous primer @ 0.30 ltrs/sqm and allow to dry. (b) Applying and laying torch APP polymer modified bituminous membrane 3 mm thick with non woven polyester mat as reinforced weighing not less than 3 kg/sqm by thermo fusion process as per manufacturers specification including applying one coat of aluminum paint. Note:- Removed thar felt shall be removed out of MD Land and spilled over bitumin if any on any surface shall be made good to the satisfaction of Enginer in Charge, no extra payment shall be claimed by the contractor in this account
M&L Rendering 10 mm thick in cement and sand mortar (1:3) by using 100% coarse sand on roof mixed with & including WPC @ 3% by weight of cement and finished the surfaces even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge. includning taking down existing plaster
M&L Rendering 15 mm thick in cement and sand mortar (1:6) on fair faces of brick work or concrete wall surfaces and finished the surfaces even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
Rendering 5 mm thick in cement and sand mortar (1:6) on fair faces concrete ceiling surfaces and finished the surfaces even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
M&L for providing, cement concrete in roof as padding concrete Type B0 (1:2:4) using (12.5mm aggregate) for leveling etc complete all as specified and directed by Engineer-in-Charge.
M & L 6mm thick asbestos cement, corrugated or semi corrugated sheets in roof walls fixed with 'L' type or 'J' type or cranked hook bolts, washer etc including dismantling etc complete all as specified and directed by Engineer-in-Charge.
Fixing only 6mm thick asbestos cement, corrugated or semi corrugated sheets in roof walls fixed with 'L' type or 'J' type or cranked hook bolts, washer etc including dismantling etc complete all as specified and directed by Engineer-in-Charge.
Dismantling single layer manglore tiles or similar in roofs at any height etc complete all as specified and directed by Engineer-in-Charge.
M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry including dismantling etc complete all as specified and directed by Engineer-in-Charge.
Fixing only old roof tiles,Mangalore pattern, interlocking at side joints, laid dry etc complete all as specified and directed by Engineer-in-Charge.
S&F Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class hard wood for clean swan battens at 25 cm centre to centre of size exc 5 & n exc 15 sqcm etc including dismantling etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of timber scantlings 40 Sqcm and over in section, in any position as in framed work etc complete all as specified and directed by Engineer-in-Charge.
M&L for second class wrought hard-wood in scantlings etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for false ceiling with Vinyl faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metalized polyester foil backing with Vinyl covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturer's instructions / specification and all as directed including taking down/ out existing etc complete all as specified and directed by Engineer-in-Charge. Make : Armstrong or equivalent in Saint Gobian / Lafarge
All as per item No16 (here-in-before) but fixing only old ceiling boards of any description
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws including dismantling corrugated steel sheeting, any gauge, thickness etc complete all as specified and directed by Engineer-in-Charge.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof fixed with self tapping screws complete all as specified, colour and design as approved by GE including dismantling of plain steel sheeting, any gauge, thickness etc complete all as specified and directed by Engineer-in-Charge.
S&F steel work in tubular trusses including special shaped washer conforming to IS 1161-1979 grade St.-240 etc complete all as specified and directed by Engineer-in-Charge.
S&F of steel work in post, Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. as per Fe 410 -W (Gde- E- 250) quality- A etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of surface of tiles or slate battens, any size and spacing and treated all over measured overall on one side only(spaces not deducted) and apply Creosote oil etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of walls and applying one coat of cement base paint etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of walls and applying two coats of cement base paint etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparing old plastered surfaces of walls and apply one coat of OBD, finished with roller finish on plastered surfaces of wall etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered treated surfaces of walls/ roof by brooming down and applying one coat of weather proof 100 % acrylic exterior emulsion apex ultima paint of any tint as approved by GE after cleaning the surfaces etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide etc complete all as specified and directed by Engineer-in-Charge.
M&L for aplying one coat of 'Tile guard' of approved shade over any type of roof surfaces including preparations at any height including scaffholding and safety measures etc complete all as specified and directed by Engineer-in-charge.
M&L for cleaning of service tank up to 500 ltrs by removing all scales, dirt, silt, mud etc from tank and mouth of outgoing pipe including washing of tank internally with blEACHing powder after removing scale, dirt, silt, mud etc from tank and removing algae from outside of tank from below bottom of tank and disinfecting tank by spraying sodium hypo chloride solution in tank and writing date of cleaning on tank with synthetic enamel paint size of alphabet / numerical shall be minimum 7 cm etc complete all as specified and directed by Engineer-in-Charge. Note:- The quoted rate shall include dismantling and refixing of water tank as etc complete all as specified and directed by Engineer-in-Charge
All as per item No 29 (here-in-before) but 501 to 1000 ltrs
All as per item No 29 (here-in-before) but 1001 to 2000 ltrs
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 500 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 32 (here-in-before) but 1000 ltr capacity
Disconnecting existing 500 ltr capacity water tanks, setting aside (or lowering if required) for repairs, cleaning, etc and re-fixing in position etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 34 (here-in-before) but 1000 ltr capacity
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 36 (here-in-before) but 110 mm bore
S&Fof 75 mm bore PVC (SWR) bends etc complete all as specified and directed by Engineer-in-Charge.
S&F of 110 mm bore PVC (SWR) bends etc complete all as specified and directed by Engineer-in-Charge.
M&L in repairs spouts of 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 using graded stone aggregate including removing old souts etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 40 (here-in-before) but 110mm bore
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 42 (here-in-before) but 20 mm bore tubing
All as per Sl item No 42 (here-in-before) but 25 mm bore tubing
Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 45 (here-in-before) but 20 mm bore tubing
All as per Sl item No 45 (here-in-before) but 25 mm bore tubing
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor all as directed.
Demolition of plain cement concrete (unreinforced) in ground floor not exceeding 15 cm thick all as directed.
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base all as directed.
Material and labour for joint free / rectified non skid ceramic coloured tiles non skid, 8-10 mm thick of size 395mmx395mm as approved by GE (square / rectangular) as in floor etc laid over and including screed bed 20 mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match complete all as specified and as directed.
An amount of Rs 43,292.50 shall be deducted from BOQ on account of schedule of credit
M/S. YADAV ENTERPRISES
M/S-B.R.SONAWANE
Neha Enterprises
Manak landmarks
M/s. N D Karande
MS. G.A. CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .