Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.0 L+₹8.6 L (103.7%)Rejected-Finance 204 208 GAURI COMPLEX ABOVE BANK OF BARODA VASAI EAST MUMBAI MAHARASHTRA 401210 | 401210 | L2 | Rejected-Finance L2 | |
| 3 | L3₹25.0 L+₹16.7 L (200.0%)Rejected-Finance NO 2 429 MOUNT POONAMALLEE ROAD AYYAPANTHANGAL CHENNAI AYYAPANTHANGAL KANCHIPURAM TAMIL NADU 600056 | THIRUVALLUR | TAMIL NADU | 600056 | L3 | Rejected-Finance L3 | |
| 4 | L4₹35.9 L+₹27.5 L (329.8%)Rejected-Finance 1 430 GARIAHAT ROAD SOUTH 3RD FLOOR KOLKATA KOLKATA WEST BENGAL 700068 | KOLKATA | WEST BENGAL | 700068 | L4 | Rejected-Finance L4 | |
| 5 | L5₹41.7 L+₹33.4 L (400.3%)Rejected-Finance PLOT NO 26 VIKASPURI POWERTEST ASIA PVT LTD 26 VIKASPURI S R NAGAR POST HYDERABAD 500 038 INDIA SR NAGAR POST | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹32,300
Closing Date
30 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM T
SRPL Chennai
Condition Monitoring Diagnostic Testing of Major Electrical Equipments at SRPL Manali, Asanur and Chittoor Station
2020_SRCHN_123478_1
SRP20TS023
Open Tender
Electrical Works
Works
60 days
Chennai
Refer NIT
6 documents required · 6 mandatory
₹32,300
Yes
8 Jan 2021
10 Sept 2020
1 Oct 2020
10 Sept 2020
30 Sept 2020
14 Sept 2020
120 days
Amount
Condition monitoring of CTMP Eqpt Manali
Diagnostic testing of 3 No's of M/s Ansaldo Make 800KW, 6.6KV, 81.3A, 50Hz motors. The test includes the following: Insulation Resistance/Polarization Index test,, Tan delta & Capacitance Test Partial Discharge Test Winding DC Resistance Test DC leakage measurement Surge comparison Test The following diagnostic test are proposed to be carried out during Condition Monitoring of Motors using Electrical Signature Analysis: Rotor Bars health Static and Dynamic Eccentricity Stator mechanical problems Loose Windings and Core Damages ,, Winding Inter-Turn Short Circuits ,, Rotor Misalignment and Imbalance ,, Resonance ,, Bearing conditions ,, Motor air gap problem ,, Motor mounting/foundation condition ,, Motor shaft condition etc as per the detailed scope of work of the Contract.
Condition monitoring of 6.6KV/415V, 500 KVA,50 Hz and 6.6KV/ 415V,1600KVA,50Hz Transformer which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, Transformer oil analysis as per IS1866:2000 and DGA, an analysis for Transformer Oil etc as per the detailed scope of work of the Contract.
Condition monitoring of 6.6KV/690V,1150KVA Dry Transformer, which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, as per the detailed scope of work of the Contract
Condition monitoring of CBPL Eqpt Manali
Diagnostic testing of 5 No's of M/s Ansaldo Make 390KW, 6.6KV, 40.7A, 50Hz motors. The test includes the following: Insulation Resistance/Polarization Index test,, Tan delta & Capacitance Test Partial Discharge Test Winding DC Resistance Test DC leakage measurement Surge comparison Test The following diagnostic test are proposed to be carried out during Condition Monitoring of Motors using Electrical Signature Analysis: Rotor Bars health Static and Dynamic Eccentricity Stator mechanical problems Loose Windings and Core Damages ,, Winding Inter-Turn Short Circuits ,, Rotor Misalignment and Imbalance ,, Resonance ,, Bearing conditions ,, Motor air gap problem ,, Motor mounting/foundation condition ,, Motor shaft condition etc as per the detailed scope of work of the Contract
Condition monitoring of 6.6KV/415V, 630 KVA,50 Hz Transformer which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, Transformer oil analysis as per IS1866:2000 and DGA, an analysis for Transformer Oil etc as per the detailed scope of work of the Contract.
Condition monitoring of 6.6KV/690V,570KVA Dry Transformer, which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, as per the detailed scope of work of the Contract
Condition monitoring of Eqpt at Asanur
Condition monitoring of 1 no. 6.6KV/415V,1000KVA,Transformer, 2 nos. 6.6KV/600V,710KVA,Transformer, 1 no. 6.6KV/415V,300KVA,Transformer which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, Transformer oil analysis as per IS1866:2000 and DGA, an analysis for Transformer Oil etc as per the detailed scope of work of the Contract.
Diagnostic testing of 3 Nos. of M/s Loher Make 6.6KV,52A, 510KW,50 Hz motors. The test includes the following: Insulation Resistance/Polarization Index test,, Tan delta & Capacitance Test Partial Discharge Test Winding DC Resistance Test DC leakage measurement Surge comparison Test The following diagnostic test are proposed to be carried out during Condition Monitoring of Motors using Electrical Signature Analysis: Rotor Bars health Static and Dynamic Eccentricity Stator mechanical problems Loose Windings and Core Damages ,, Winding Inter-Turn Short Circuits ,, Rotor Misalignment and Imbalance ,, Resonance ,, Bearing conditions ,, Motor air gap problem ,, Motor mounting/foundation condition ,, Motor shaft condition etc as per the detailed scope of work of the Contract.
Condition monitoring of 2 Nos. 33KV/6.6KV,8MVA,50Hz Transformer, which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, Transformer oil analysis as per IS1866:2000 and DGA, an analysis for Transformer Oil etc as per the detailed scope of work of the Contract.
Condition monitoring of Dry Transformers 1 No. 6.6KV/6.6KV, 700KVA Transformer, 2 Nos. 6.6KV/540 V, 710KVA Transformers which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, as per the detailed scope of work of the Contract.
Condition monitoring of Eqpt at Chittoor
Condition monitoring of 1 No. 6.6KV/415V,1500KVA,50Hz, Transformer, which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, Transformer oil analysis as per IS1866:2000 and DGA, an analysis for Transformer Oil etc as per the detailed scope of work of the Contract.
Diagnostic testing of 3 Nos. of M/s BHEL Make 6.6KV,870KW,50 Hz motors. The test includes the following: Insulation Resistance/Polarization Index test,, Tan delta & Capacitance Test Partial Discharge Test Winding DC Resistance Test DC leakage measurement Surge comparison Test The following diagnostic test are proposed to be carried out during Condition Monitoring of Motors using Electrical Signature Analysis: Rotor Bars health Static and Dynamic Eccentricity Stator mechanical problems Loose Windings and Core Damages ,, Winding Inter-Turn Short Circuits ,, Rotor Misalignment and Imbalance ,, Resonance ,, Bearing conditions ,, Motor air gap problem ,, Motor mounting/foundation condition ,, Motor shaft condition etc as per the detailed scope of work of the Contract.
Condition monitoring of 6.6KV/690V,1700 KVA Dry Transformer, which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, as per the detailed scope of work of the Contract
Condition monitoring of 2 Nos. 33KV/6.6KV,6MVA,50Hz Transformers which includes following tests: Insulation resistance Polarization Index test Winding DC resistance measurement Tan delta & Capacitance test, ,, Recovery voltage measurement, ,, Winding Resistance Test, ,, Sweep frequency response analysis, Transformer oil analysis as per IS1866:2000 and DGA, an analysis for Transformer Oil etc as per the detailed scope of work of the Contract
Fixed Charges including transportation,
Transportation, Insurance, Travel charges etc. including all taxes, as applicable for transportation of all Manpower, materials, Testing equipments, required for diagnostic testing at CTMPL Manali, Asanaur and CBPL Chittoor
Diagnostic Technologies India Pvt. Ltd.
M/s. Voltech Engineers Pvt Ltd
NAVITUS CONTROLS AND EQUIPMENT PVT LTD
Powertest Asia Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .