Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹52.7 L+₹2.3 L (4.50%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹53.1 L+₹2.7 L (5.37%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹53.3 L+₹2.9 L (5.67%)Rejected-Finance SAPTARAG APARTMENT RAGHUNATHPUR RAA 35 V I P ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹53.9 L+₹3.5 L (6.93%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹47.5 L
EMD Value
₹94,920
Closing Date
6 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO BLDG NO. MT-2 AND MT-5 INSIDE FORT WILLIAM AND PROVN OF SHED IN FRONT OF ALL STORES AND FOR MAIN ENTRANCE AT BLDG NO BI-1 UNDER GE(FW) KOLKATA
2022_MES_529841_4
GE(FW)/8853/E8
Open Tender
Civil Works
Item Rate
210 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹94,920
23 Sept 2022
18 Aug 2022
7 Sept 2022
18 Aug 2022
6 Sept 2022
18 Aug 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling of Asbestos cement corrugated, semi-corrugated sheet in roof covering complete all as a specified and as directed
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
S&F circulator/ventilator wind driven turbine with FRP base of size 32" x 24" to match roof sheet with polyster resin powder coated, top of ventilator turbine made out from aluminium with integrated and reinforced main bearing housing the shaft of stainless steel and varpitch from alumnium, rotation bearing will be twin ZZ ball bearing encased in single integrated bearing housing etc complete all as specified and directed. (MAKE : SVS, Model : Hurricane 600 or equivalent model in Shirjee / Golden Engineers / Airier)
S&F in repairs galvanized, plain mild steel sheeting 0.80 mm thick, with minimum zinc coating of 120 gram/Sq m, as in ridge, hips, valley gutters, drip and straight flashing, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for Mild steel hand rails, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 complete . (NOTE: Measurement shall be taken for the ms flat only. Quoted rate is deemed to include for the cost of securing bolts etc)
Dismantling of ceiling board incl snap grid frame of any thickness including cover fillets complete all as specified and directed.
M&L for snap grid system with powder coated aluminium main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and powder coated aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with supporting 6 mm dia. G.I hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
Re-fixing of aluminium snap grid sytem using serviceable grid sections obtained from taking down of false ceiling, fixed to ceiling with supporting 6 mm dia. G.I hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
S&F 'E' board "Classic", reinforced, designer series, ceiling board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid system complete all as specified and as directed.
Re-fixing of serviceable ceiling board/tiles, obtained from dismantling of ceiling grid, any thickness, fixed to aluminium frame work with screw as in ceiling complete all as specified and directed.
M&L for applying one coat of oil bound distemper on new ceiling boards complete all as specified and directed.
M&L for applying one coat of oil bound distemper on old ceiling boards complete all as specified and directed.
M&L for cutting holes in brick wall exceeding half brick but not exc one brick thick walls for inserting hold fasts for mild steel grills and making good dismantled portion in cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) including necessary formwork and making good surfaces as per existing finisjhes complete all as specified and directed.
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
S&F welded steel wire fabric n. exc 4 Kg/sqm, fixed to wood or steel members complete all as specified and directed.
S&F in repair fibre glass reinforcement translucent corrugated sheeting of 2mm thick with two corrugation side lap fixed with fixed with L type or J type or cranked hook bolts in roofs, walls etc complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all quaries, arches pillars etc and removing debris off the site complete all as specified and directed.
M&L for brickwork with fly-ash old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for dubbing out cement plaster (1:4), average 20 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortor (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per 50 kg bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only"
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed.
M&L for laying and fixing Machine cut kota stone slab flooring 18-20 mm thick over and including 20 mm thick screed base in cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for fixing Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillars etc, fixed over and including 10 mm thick screed bed in cement mortar 1:3, fixed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Taking down existing rolling shutter incl covering guide, channe etc, of area not exc 8.00 sqm each, replacing damaged parts such as guide channel; shaft, ball bearing, laths, locking system, hood incl necessary welding and greasing complete as required and refixing in position etc complete all as specified and directed. (Note : Spare parts required will be measured and paid separately under respective items)
Taking down existing rolling shutter incl covering guide, channe etc, of area exc 8.00 sqm but not exc 12sqm each, replacing damaged parts such as guide channel; shaft, ball bearing, laths, locking system, hood incl necessary welding and greasing complete as required and refixing in position etc complete all as specified and directed. (NOTE: Spare parts required will be measured and paid separately under respective items)
Supply only springs for rolling shutters complete all as specified and directed.
Supply only ball bearing for rolling shutters complete all as specified and directed.
Supply only guide channel complete all as specified and directed.
Supply only locking system for rolling shutter complete all as specified and directed.
Hacking out old broken glass (any thickness and size or quality) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
Hacking out old broken glass (any thickness and size or quality) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F sheet glass 3 mm thick, ordinary quality, glazing with oil putty in squares not exceeding 0.5 Sqm in each pane all as specified.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane all as specified.
M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces not exc. 10 cm width or girth including preparation of surfaces complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden surface of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted steel surface and providing two coats of synthetic enamelled paint of any description, over 10cm in width or girth, not otherwise described for complete all as specified and directed.
M&L for complete removal of existing treatment and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment on walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces on walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Demolition of concrete Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below groud level) complete all as specified and as directed.
M&L for 50 mm thick PCC type B1 using 20 mm graded stone aggregate as in floors, path, plinth protection etc, finished even and smooth without using extra cement complete all as specified and directed.
S&F PVC (SWR) pipes, type-A for use in ventilation pipe work and rain water and rain water harvesting, single socket, 110 mm bore in any length including rubber ring joints and fixed to wall with clips, other standard material, all as specified in IS 13592 for building height up to 4 storey complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed.
S&F Stack clamps for 100 mm dia bore pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earh around in layers not exceeding 25 cm for soft/loose soil complete all as specied and directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40 mm graded aggregates) in foundation filling and mass concrete complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
-ditto- but in posts complete all as specified and directed
M&L for Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc. n. exc 10 kg each brackets, conforming to Fe-290 Gde E-165 (brackets over 10 Kg each to be measured under 'structural steel') complete .
M&L for PCC, 25 mm thick, 1:2:4 type B0 using 12.5 mm graded aggregates as in flooring, sub base etc complete all as specified and directed.
M & L for pre-polished Chequred cement concrete tiles (coloured) of size 30cmx30cmx22-25mm thick, set, jointed and pointed in neat cement slurry in floor and pointed with grey cement & pigment to match the surface laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed .
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 63 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 63 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 63 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F socket outlet 6/16 Amps, 6 in 1, flush type complete all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 15/16 Amp one way complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in polycarbonate housing, 110 lumen/watt efficacy, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
S&F LED Highbay luminaire, circular shape, of 150 watt capacity, 130 lumen/watt efficacy, in high pressure die cast aluminium housing with lens and toughened glass cover with integrated constant current electronic driver, incl necessary electric connection with suitable copper wire complete all as specified and directed.
Taking down of existing exhaust fan, 300mm-380 mm sweep from any height, opening the fan, removing the damaged coil and rewinding the coil with suitable gauge of copper wire as per requirement including oiling, greasing and replacement of unserviceable accessories such as capacitor, connector, bearing etc, painting of fan with one coat of synthetic enamel paint by spray painting, re-assembling and fixing in existing location and testing complete all as specified and directed.
-ditto- but for exhaust fan of size 450mm -600 mm sweep
Taking down of existing air circulator fan, 450mm-600 mm sweep from any height, opening the fan, removing the damaged coil and rewinding the coil with suitable gauge of copper wire as per requirement including oiling, greasing and replacement of unserviceable accessories such as capacitor, connector, bearing etc, painting of fan with one coat of synthetic enamel paint by spray painting, re-assembling and fixing in existing location and testing complete all as specified and directed.
M&L for sub main wiring with 4 runs (P-N) of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm 1100 volts grade along with one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10 sqmm 1100 volts grade as earth continuity conductor drawn through and including adequate size PVC non-metallic concealed conduit incl taking down existing sub main wiring complete all as specified and as directed. (NOTE : Five runs of single core 10.0 sqmm cable and one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 78 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC conduit (NOTE : Three runs of single core 4.0 sqmm cable and one run of PVC conduit shall be measured as one unit)
S&F in repair TPN DB, IP 43 protection, double door, 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed.
S&F in repair SPN DB, IP 43 protection, double door, 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed.
S&F in repair Double Door, Sheet Metal Enclosure for DBs, for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F in repair MCB, 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
KWALITY CONSTRUCTION
M/S SRINIVASA CONSTRUCTION
B & R CONSTRUCTION
PRABIR TRADERS
MS AP CONSTRUTION AND CO
PEARL CORPORATION
MODERN AGENCY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .