Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹27.8 L+₹17,507 (0.63%)Rejected-Finance RENUKA BUNGLOW BELA DSOUZA ROAD JAIL ROAD NASIK ROAD NASHIK MAHARASHTRA 422101 | NASHIK | MAHARASHTRA | 422101 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹28.7 L+₹1.2 L (4.18%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹29.4 L+₹1.8 L (6.41%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹29.6 L+₹2.0 L (7.19%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
18 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
PROVISION OF GEYSER EHHAUST FANS IN CERTAIN SMQs PH IV AND AUGMENTATION IMPROVEMENT OF STREEET LIGHTS SECURITY LIGHTS OF DOMESTIC AREA AT AF STATION OJHAR
2022_MES_542187_1
8904/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹72,000
Yes
24 Sept 2022
30 Jul 2022
20 Aug 2022
1 Aug 2022
18 Aug 2022
12 Aug 2022
Amount
Dismantling old/unserviceable LT PCC /Steel pole 9 mtr height including all fittings, any type and size and removing the dismantled mtrl from site complete all as specified and directed by Engr -in-charge.
Taking down old / unserviceable LT cable, cleaning the same and repair the faulty portion of the cable up to 25 sqmm of size and relaying the same at another location at domestic area including all electrical connection complete all as specified and directed by Engr -in-charge.
Taking down of old /serviceable street light fitting with bracket any type, refixing the same on another location domestic area including all electrical connection complete all as specified and directed by Engr -in-charge.
Shifting of LT Steel tubelar pole 9 mtr long from one place to another place at entier location of GE AF Ojar including all earth work and PCC (1:4:8) for foundation of work complete all as specified and as directed by engr in charge.
S&F Hot Dip Galvanised Octagonal GI Pole 7 mtr long with dome, top dia 70 mm and bottom dia 130 mm, 3 mm thickness of sheet , fixing on base plae 200X200X12 mm with foundation nut & bolt of size 4XM20X700. including all earth work and fondation as recommeded by OEM design with 63 mm Flexible pipe for cable entry complete all as as directed by Engr-in-charge.Make Surya Cat Pt No- SRL-OP-703 or equvalent in Bajaj and Crompton.
S&F Octagonal GI Pole bracket single arm 1.50 mtr long, single arm fixing withsuitable nut bolt and washer as described in OEM manual complete all as as directed by Engr-in-charge.Make Surya cat pt No SBA-02 or equivalent in Bajaj, CG.
S&F Octagonal GI Pole bracket Double arms 1.50 mtr long, fixing withsuitable nut bolt and washer as described in OEM manual complete all as as directed by Engr-in-charge.Make Surya cat pt No SBA-02 or equivalent in Bajaj, CG.
Supply and Installation, LED street light fittings 70 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, input voltage 140-270V, PF >0.95 Make Crompton CAT No TRP-409-70-570-SL-GL-NSG or equivalent in BajaJ/Surya. complete all as specified and directed by Engineer- in-charge..
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable multistanded with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm all as specified and directed.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 38mm
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
Supply, installation, commissioning and testing of storage type electric water heater of capacity 25 Ltrs, AC ,240 Volt, 50 Hz, 5 star rating vertical/ Horizental type duly fixed to existingposition where directed including suitable mounting bolts, nuts and washer duly grouted including necessary accessories such as saftey valve, thermostste, NRV, inlet / out water connection piece etc incl writing MES No, on Geyser with white synthetic enamelled paint , all as specified and as directed by Engr-in-Charge. Make Bajaj Cat pt MONTAGE 25 L , Crompton ARNO NEO, Havells MONZA 25L , USHA Misty digital .
S&F Exhaust fan 300 mm sweep, 4 blade ( Mettallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the existing wall, plastering, white washing or colour washing to the disturbed surface of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector including writing MES No. on Exhaust fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Bajaj Cat pt MAXX AIR , Crompton Transair, Havells Venil Air -DB NEO , USHA Turbo DBB.
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
Modular switch one way 6 Amp,1 Module , Make Legrand Mylinc Cat No 675501 or equivalent in Anchor Roma/Crabetree .
Supply & Fix Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm two to three terminals. Make : Anchor/Leader.
M&L for Sub main wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run on wall with PVC cassing capping not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches etc for each geyser point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supplying and fixing Modular switch , one way, 16 amps, one Module of Make:- Ancher Roma/Legrand/ Crabetree.
Supplying and fixing Modular socket 16 amps-6 pin multipin, 2 Module of Make:- Ancher Roma/Legrand/ Crabetree.
Supply and fix 15mm dia bore galvanized iron tubing, medium grade including all fitting for cable protection etc laid in floor or fixed to Wall with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
Supply and fix 15mm dia bor plug type bib taps C P brass , screwed for iron pipe and fixed.etc all as specified and directed.Make- Jileto, Seiko etc
Supply and fix 15mm dia bor stop/angle valve , C P Brass, screwed for iron pipe and fixed.etc all as specified and directed.Make- Make- Jileto, Seiko etc
LOKMANYA ENTERPRISES
Sutej Electricals
MAHIMA CONSTRUCTION
sapana enterprises
SHRI SULAI ELECTRICALS
Datar Electrical and Engg Services
DIAMOND ENTERPRISES
Takshashila electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .