CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
REPAIRS / PERIODICAL MAINTENANCE OF STAND BY DG SETS AND CONNECTED WORKS AT AFA HYDERABAD
2022_MES_547963_1
86687/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AFA HYDERABAD
₹90,000
Yes
14 Oct 2022
26 Aug 2022
1 Oct 2022
26 Aug 2022
29 Sept 2022
15 Sept 2022
26 Aug 2022 - 10 Sept 2022
Amount
M&L for the following Periodical Maintenance/Servicing for diesel Gen set installed at AFA for trouble free operation of generator sets and ensuring the serviceability , carrying out minor spares (if any/ settings required for operation of the set shall be carried out without any extra cost for the following capacity Model/ Make by carry out the inspection /work by an authorized service centre including within Two months from the date of commencement and once in every three months subsequently. Engine Maintenance (i) Changing the lubricant oil (ii) Checking the oil level in complete DG sets (iii) Checking of alternator, checking/changing fan belt if required (iv) Checking of circuits of various controls of engine (v) Draining the water seperator bowels to remove water/sediments (vi) Checking and tightening of all external fasteners (vii) Checking and tightening of all lube and fuel/hose connections (viii)Changing of fuel filter, Lub oil filter and Air filter if required (ix) Arresting all water /lubricant/fuel leakages and topup (x) Checking of all engine parameters (xi) Checking of the electrical exitation system (xii) checking all the performance of AMF panel in all respect
Note :- (i) All repairs /periodical maintenance shall have to be carried out by the authorised service personnel (ii) M&L for spares, lubricant etc required for engine, alternator & AMF panel will be measured and paid separately under relevant items.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Above 62.5 KVA and upto 125 KVA Capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Above 125 KVA and upto 320 KVA Capacity DG Set of Make : -Kirloskar / Cummins / Greaves
Above 320 KVA and upto 625 KVA Capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Supply and fixing of Engine Oil seal and gasket for the DG Set of the following Capacity including removal of old unserviceable gasket and oil seal including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing in Repair of V belt for following Capacity DG sets including removal of old unserviceable V belt including connection up complete all as specified and as directed. Make :- Fenner, Finex , Supreme.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Ammeter suitable for following Capacity DG sets including removal of old unserviceable Ammeter including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of oil pressure guage for following Capacity DG sets including removal of old unserviceable oil pressure guage including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of speedometer cable for following Capacity DG sets including removal of old unserviceable speedometer cable including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of push button switch for stop/start of DG engine for following Capacity DG sets including removal of old unserviceable push button switch including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Ignition switch for following Capacity DG sets including removal of old unserviceable Ignition switch including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Lub Oil filter set for following Capacity DG sets including removal of old unserviceable Lubrication Oil filter set including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Diesel filter set (Primary and Secondary) for following Capacity DG sets including removal of old unserviceable Diesel filter set including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Air filter set (Inner and Outer) for following Capacity DG sets including removal of old unserviceable Air filter set including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Universal multi function relay in AMF panel of DG set for following Capacity including removal of old unserviceable relay including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Power contactor 4 pole of capacity 800 A with auxiliary contactors of 2 NO's and 2 NC's confirming to TC contactors of equivalent in ABB, L&T schneider, C&S suitable for AMF panel of 625 KVA DG set complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 600 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to TC contactors or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 320 KVA DG set complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 400 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to TC contactors or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 160/250 KVA DG set complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 200 to 250 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to MEC LS Model GMC-180/4 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 100 KVA DG set complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 150 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to MEC LS Model GMC-180/4 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 50/63 KVA DG set complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 63 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to L&T Model MCX11 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 15/30 KVA DG set complete all as specified and as directed.
M&L for filling / top up of distilled water for the batteries of the DG Sets complete all as specified and as directed.
Supply and fixing solenoid switch, including removing of unserviceable solinoid switch from Gen set including accessories like nuts, bolts washers etc complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing self starter 12/24 Volt DC, including removing of unserviceable self starter 12/24 volts DC from Gen set including accessories like nuts, bolts washers etc complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
M&L for remove the unserviceable winding of self starter 12/24 volts DC from Gen set of following capacity DG set including rewinding of unserviceable burnout winding with high conductivity best quality super enamelled copper winding, including replacement of insulated material, wires gushes etc complete all as specified and as directed. Note :- copper wire will be measure and paid seperately under relevent items
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repairs new armature with brushes and brush holder for dynamo of following DG set capacity including removing the burnout armature , clean the internal surfaces ,servicing, complete all as specified and as directed for following capacity DG Sets :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply and refilling Coolant suitable for Diesel generating sets of any capacity complete all as specified and as directed.
M&L for Painting of the following DG sets after preparing the external surfaces apply one coat of primer and spray painting by superior quality enamel paint connected panel etc including Engine, Alternator, canopy, base frame, radiator, battery stand, connected etc complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Removing the unserviceable Diesel level indicating plastic pipe of approx size 10 mm dia and both end clamps and replace with new Plastic pipe of same size to the required level and clamps on both the sides complete all as specified and as directed.
Remove the radiator from the gen set drain out the coolant servicing, arresting leakages by welding/brazing etc, supply and replacing the u/s mounting rubber, clean the internal surfaces and de-scale by using cleaning agents and fixing back in position complete all as specified and as directed. for the following capacities :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Material and labour for repairs to the following DG Set alternator and removing the same from engine of DG Set, transporting the same to the work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing complete all as specified and as directed. Note :- Copper winding material will be measured and paid seperately under relevent item
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Remove the fuel injection pump from the engine transport to an authorized service centre for servicing, calibration and to adjust by replacing the following U/S worn-out spares with new appropriate make spares and bringing and fixing to the engine and tune up for maximum efficiency complete all as specified and as directed.for following capacity of DG Sets :- Note :- Major spares required will be measured and paid seperately:
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply Only orifice for following capacity DG set :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply Only Barrel and Plunger for following capacity DG Sets :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
Supply Only FIP Bearing for following capacity DG Sets :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Neon type indicating lamp complete all as specified and as directed.
S&F in repair exhaust fan of metal body size 300 mm sweep 230 Volt, 1400 RPM, including fixing and connecting complete all as specified and as directed.
S&F in repair exhaust fan of metal body size 350 mm sweep 230 Volt, 1400 RPM, including fixing and connecting complete all as specified and as directed.
S&F in repair exhaust fan of metal body size 400 mm sweep 230 Volt, 1400 RPM, including fixing and connecting complete all as specified and as directed.
S&F in repair HRC Fuse unit 20Amp to 100 Amp Capacity for DG Sets complete all as specified and as directed.
S&F in repair HRC Fuse unit 120Amp to 165 Amp Capacity for DG Sets complete all as specified and as directed.
S&F in repair HRC Fuse unit 200Amp to 420 Capacity for DG Sets complete all as specified and as directed.
S&F in repair Generator Set controller unit of AMF Panel for following capacity DG Sets as per existing model and Make of Kirloskar / Cummins / Greaves complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Power Command of DG Sets AMF Panel as per existing model of DG Sets of capacity 160 KVA to 250 KVA icluding taking down existing complete all as specified and as directed.
S&F in repair Power Command of DG Sets AMF Panel as per existing model of DG Sets of capacity above 250 KVA up to 500 KVA icluding taking down existing complete all as specified and as directed.
S&F in repair MCCB 32 Amps 3 pole, model DU 100 suitable upto 62.5KVA DG set AMF Panel complete all as specified and as directed. Make : - L&T, Schneider, Havells, C&S, ABB, Legrand.
S&F in repair MCCB 125 Amps 4 pole, model DPX3 160 suitable to above 160KVA to 400 KVA DG set AMF Panel complete all as specified and as directed. Make :- L&T, C&S, Havells, C&S, ABB, Legrand.
Taking out existing outlived old engine oil, clean the engine oil sump and filling/ Top up engine oil 20 W 40 to DG Sets of capacity 15 to 625 KVA complete all as specified and as directed. Make :- Servo / Castrol / Valvoline
S/F in Repair water pump DG sets as per existing model of following capacity, including necessary dismantling to existing pump including necessory testing to the Entire satisfaction of Engineer - in - Charge.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
M & L for repairing door of DG set as per existing damaged doors including necessory items like Left & Right side Door hinges and door locks with keys of Make Kirloskar / Cummins / Greaves complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair of unserviceable IEVR - II ( industrial electronic voltage regulator) as per existing model making connection, including taking down existing IEVR of Make :- Kirloskar / Cummins / Greaves complete all as directed and as specified.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair of electronic control panel governor of following DG Sets as per existing model of Make: Kirloskar Kirloskar / Cummins / Greaves complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Sensor Unit for engine safety control unit (precol panel assembly) of DG sets as per existing model of capacity 15 KVA up to 100 KVA, including taking down old unserviceable complete all as directed and as specified.
S&F in repair Sensor Unit for engine safety control unit (precol panel assembly) of DG sets as per existing model of capacity above 100 KVA up to 320 KVA, including taking down old unserviceable complete all as directed and as specified.
S&F in repair Sensor Unit for engine safety control unit (precol panel assembly) of DG sets as per existing model of capacity above 320 KVA up to 500 KVA, including taking down old unserviceable complete all as directed and as specified.
Supply and fixing copper wire 10 Sqmm copper conductor unsheathed, multistranded, PVC insulated, 1100volts grade, single core cable to panel board/AMF Panel of DG set of any capacity complete with thimble, lugs and connector etc as required side complete all as specified and as directed.
Supply and fixing copper wire 16 Sqmm copper conductor unsheathed, multistranded, PVC insulated, 1100volts grade, single core cable to panel board/AMF Panel of DG set of any capacity complete with thimble, lugs and connector etc as required side complete all as specified and as directed.
S&F in repair Alternator AVR (automatic voltage Regulator) card of DG Sets of capacity 15 KVA upto 250 KVA DG set as per sample of Make :- kirloskar / Cummins / Stamford complete all as specified and as directed.
S&F in repair Alternator AVR (automatic voltage Regulator) card of DG Sets above 250 KVA upto 500 KVA DG set as per sample of Make :- kirloskar / Cummins / Stamford complete all as specified and as directed.
S&F in repair of AMF panel contactor coil as per existing model of capacity 15 KVA up to 250 KVA complete all as specified and as directed. Make : - L&T or equivalent approved make
S&F in repair of AMF panel contactor coil as per existing model of capacity above 250 KVA up to 500 KVA complete all as specified and as directed. Make : - L&T or equivalent approved make
Opening of tappet cover and carrying out necessary adjustments of the tappets, push rods, rocker arms etc, upto 625 KVA Kirloskar/Cummins engine, including S&F of set of Gasket set, minor spares including refixing and testing complete all as specified and as directed.
S&F in repair of Anti Vibration pad for 160/200 KVA DG Set including taking down anti Vibration existing padof DG Set complete all as specified and as directed.
S&F in repair Module Electronic Control as per existing, incuding taking down unserviceable existing Module Electronic Control of 160/200 KVA DG Set and connecting complete all as specified and as directed.
S&F in repair VMR 3 P ( Voltage Monitoring Relay Protection of 3 Phase) (REL ) as per existing model of following DG Sets and making connections, including taking down existing VMR complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Fuel water separator filter for DG Set as per existing model of following capacity including taking down existing complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Super bypass filter for DG Set as per existing model of following capacity including taking down existing complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair VSP D2 (Phase failure realy) for DG Set as per existing model of following capacity including taking down existing complete and all as directed and as specified.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Capacity above 62.5 KVA and upto 125 KVA Capacity DG Set
Capacity above 125 KVA and upto 320 KVA Capacity DG Set
Capacity above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair PCB assembly of DG Sets of capacity 15 KVA up to 250 KVA as per existing model of following capacity including taking down existing complete all as specified and as directed.
S&F in repair PCB assembly of DG Sets of capacity above 250 KVA up to 500 KVA as per existing model of following capacity including taking down existing complete all as specified and as directed.
Taking down Turbo charger assembly from the DG Sets of capacity 320 to 625 KVA make -Kirloskar/Cummins engine and carrying out for cleaning and overhawling including providing minor spare parts/ Repair kit and Refixing the same complete for optimum out put of the engine complete all as specified and as directed.
Taking out old unservciceable burnt out copper winding wire from for the Item No 22 and 28, and Rewinding with supper enameled copper wire as per existing guages and turn with necessary heats, varnishing to achieve insulation Resistance to required mega ohms complete all as specified and as directed.
Supply & Fixing battery terminal lead including terminals (Positive) and necessary lugs and applying silica gel complete all as specified and as directed.
Supply & Fixing battery terminal lead including terminals (Positive) and necessary lugs and applying silica gel complete all as specified and as directed.
M&L for draining out complete fuel from the tank and taking out the tank from the base for removing the rusted sludge by scrubbing the internal surface with wire brushes. After cleaning the tank re-install back in position and connection with other accessories complete all as specified and as directed.
M&L for steel tubing fuel pipe of above 250 up to 625 KVA DG set as per existing size from fuel tank to fuel filter of DG set alongwith all accessories for fitting and welding as required including taking down old unserviceble fuel pipe complete all as specified and as directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .