Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Inverter With Sine Wave Output ( 1 pieces ) ( Under PAC ) Make luminious Model luminouscruze7.5kvahomeandcommercialups- cruze7.5kva 1/4 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Inverter Governing specification Generally conforming to IS:13314 * Rating in KVA & Min. VAH Capacity of Battery 7.5 KVA/32400 VAH 7.5 KVA/32400 VAH Technology MOSFET-PWM MOSFET-PWM Energy Star Rating 3 Star 3 Star Trolley without trolley without trolley Type of Battery VRLA battery confirming to JISC:8702(Pt.I
RequiredII&III) VRLA battery confirming to JISC:8702(Pt.I
RequiredII&III) Backup time (Minutes) Minimum 180 Minutes * CONSTRUCTIONAL Thickness of sheet for trolley (in mm) minimum 1.2 * Trolley Material CRCA Steel * Type of enclosure CRCA Steel * Thickness of sheet for enclosure ( in mm) minimum 1.2 * Inverter shall have by pass facility Yes * FUNCTIONAL Total Harmonic distortion </=5% * Input Single Phase sine wave(120 to 260 V) * Output Single Phase sine wave 240 V * Inverter Efficiency (%) >/=87% * Overload Time (in Minutes) >/=10 * Overload of rated load (in %) >/=10 * PROTECTION Battery cut-off voltage to protect from overdischarge (in Volt) >10.5 * Degree of protection IP 21 * 2/4 METERING AND INDICATIONS The inverters shall be provided with output voltage and current meters conforming to IS 2419 : 1979 and of an accuracy class not inferior to 2.5 in accordance with IS 1248 : 1983 Yes * CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab Yes * Climatic test report as per clause 7.10.1 of IS 13314 yes * Type Test Certificate No. 1452 * Name of Lab LUMINIOUS LABS * Type Test Certificate date 12-12-2017 * Address of Lab MUMBAI INDIA * Inverter shall have valid BIS CRS certifications for </= 10 KVA Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents