Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.7 LAdmitted-Finance | -0.89% | ₹16.7 L | L1 | Admitted-Finance |
| 2 | L2₹16.7 L+₹6,551.88 (0.39%)Admitted-Finance | -0.50% | ₹16.7 L+₹6,551.88 (0.39%) | L2 | Admitted-Finance |
Tender Value
₹16.8 L
EMD Value
₹33,600
Closing Date
17 Aug 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
XEN PWD ELECT DIV ALWAR
SITC of Hot and Cold DC Inverter type split type Air Conditioners at Jodhpur House New Delhi.
2026_CEPWD_585282_5
727 NIT 12/2026-27 EE PWD ELECT DIV ALWAR
Open Tender
Electrical Works
Percentage
150 days
NEW DELHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
MD RISL / XEN PWD ELECT DIV ALWAR
₹33,600
Yes
XEN PWD ELECT DIV ALWAR
20 Aug 2026
10 Aug 2026
18 Aug 2026
10 Aug 2026
17 Aug 2026
10 Aug 2026
14 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Part A Non BSR | - | - | - | - |
| 2 | Approved By CE(Elect.)/NON-BSR/2026-27/D-388 dated 30.07.2026. | - | - | - | - |
| 3 | Supply, Installation, Testing & Commissioning of 1.5 TR High Wall Split Type Hot & Cold Inverter Air Conditioner complete with indoor unit, outdoor unit, wireless remote controller, factory charged refrigerant (R-32/R-410A), copper condenser and evaporator coils, inverter rotary/twin rotary compressor, suitable for cooling and heating operation, operating on 230V ±10%, 50Hz, Single Phase, minimum 4-Star BEE rating, ISEER not less than 4.5, nominal cooling capacity 5.2–5.3 kW (1.50 TR), nominal heating capacity 5.2–5.8 kW, cooling operating ambient temperature up to 55°C, heating operation up to -15°C, tropical compressor suitable for Indian climatic conditions, anti-corrosion blue fin/epoxy coated heat exchanger, washable anti-bacterial/anti-mould/PM2.5 air purification filter, auto restart, self-diagnosis, sleep mode, timer, turbo mode, dehumidification mode, automatic horizontal and vertical swing, minimum 5-speed indoor fan, low noise operation (maximum 45 dB(A)), indoor air flow not less than 1100 m³/hr, maximum piping length not less than 20 m, maximum level difference not less than 12 m. The unit shall include factory charged refrigerant for 3 m insulated copper refrigerant piping (liquid & gas line), condensate drain pipe, interconnecting power and control cable, outdoor mounting stand/wall bracket with anti-vibration pads, all accessories, nitrogen pressure testing, vacummisation, refrigerant topping wherever required, testing and commissioning complete as required. (Copper Piping with insulation, drain pipe paid separately). (Complete rate - 83359 including GST) | 5 | Each | 70,643.22 | ₹3,53,216.1 |
| 4 | Approved By CE(Elect.)/NON-BSR/2026-27/D-388 dated 30.07.2026. | - | - | - | - |
| 5 | Supply, Installation, Testing & Commissioning of 2.0 TR High Wall Split Type Hot & Cold Inverter Air Conditioner complete with indoor unit, outdoor unit, wireless remote controller, factory charged refrigerant (R-32/R-410A), copper condenser and evaporator coils, inverter rotary/twin rotary compressor, suitable for cooling and heating operation, operating on 230V ±10%, 50Hz, Single Phase, minimum 3-Star BEE rating, ISEER not less than 4.2, nominal cooling capacity 7.0–7.2 kW (2.0 TR), nominal heating capacity 7.0–8.2 kW, cooling operating ambient temperature up to 55°C, heating operation up to -15°C, tropical compressor suitable for Indian climatic conditions, anti-corrosion blue fin/epoxy coated heat exchanger, washable anti-bacterial/anti-mould/PM2.5 air purification filter, auto restart, self-diagnosis, sleep mode, timer, turbo mode, dehumidification mode, automatic horizontal and vertical swing, minimum 5-speed indoor fan, low noise operation (maximum 50 dB(A)), indoor air flow not less than 1500 m³/hr, maximum piping length not less than 30 m, maximum level difference not less than 12 m. The unit shall include factory charged refrigerant for 3 m insulated copper refrigerant piping (liquid & gas line), condensate drain pipe, interconnecting power and control cable, outdoor mounting stand/wall bracket with anti-vibration pads, all accessories, nitrogen pressure testing, vacummization, refrigerant topping wherever required, testing and commissioning complete as required. (Copper Piping with insulation, drain pipe paid separately). (Complete rate - 100434 including GST) | 11 | Each | 85,113.56 | ₹9,36,249.16 |
| 6 | Part B- BSR 2025 Items | - | - | - | - |
| 7 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. | - | - | - | - |
| 8 | Un Armoured | - | - | - | - |
| 9 | 4 core x 2.5 Sq.mm | 110 | mtr | 187 | ₹20,570 |
| 10 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
Tendernotice_2.pdf
PDF • 6.19 MB
Tendernotice_3.pdf
PDF • 1.59 MB
gencond12.pdf
Tender Documents • 0.37 MB
BOQ_1039835.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .