| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-Finance | ₹6.5 L | L1 | Accepted-Finance |
| 2 | L2₹6.6 LAccepted-Finance | ₹6.6 L | L2 | Accepted-Finance |
| 3 | L3₹6.6 LAccepted-Finance | ₹6.6 L | L3 | Accepted-Finance |
| Sl No | Description | Qty | Unit | TWILIGHT ELECTRICALS L2 | SOURAJIT CHAKRABORTY L1 | GREENLITE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable OPC complied Multisensor Detector (VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 60 | Nos | 2,050 ₹1.2 L | 2,000 ₹1.2 L | 2,020 ₹1.2 L |
| 2.00 | Supply, Installation, Testing & Commisioning of OPC complied Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 6 | Nos | 2,550 ₹15,300 | 2,500 ₹15,000 | 2,520 ₹15,120 |
| 3.00 | Supply, Installation, Testing & Commissioning of Addressable OPC complied Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 6 | Nos | 2,550 ₹15,300 | 2,500 ₹15,000 | 2,520 ₹15,120 |
| 4.00 | Checking, Fault Rectification, Testing and Re-commissioning of installed Edwards Make 6 Loop Fire Alarm Panel (Model No. EST- 3X) Panel Installed at Alipurduar District Hospital. | 1 | Item | 20,100 ₹20,100 | 20,000 ₹20,000 | 20,050 ₹20,050 |
| 4.01 | Checking, Fault Rectification, Testing and Re-commissioning of installed Siemens Make 2 Loop Fire Alarm Panel (Model No.FC722) Panel Installed at Alipurduar District Hospital. | 2 | Item | 15,100 ₹30,200 | 15,000 ₹30,000 | 15,050 ₹30,100 |
| 5.00 | Checking, Fault Rectification, Testing and Re-commissioning of installed Siemens Make 4 Loop Fire Alarm Panel (Model No.FC724) Panel Installed at Alipurduar District Hospital. | 1 | Item | 15,100 ₹15,100 | 15,000 ₹15,000 | 15,050 ₹15,050 |
| 6.00 | Checking, Clening, Fault Rectification, Testing and Re-commissioning of necessary field devices (Detectors & Devices- 726 Nos) Edwards & Siemens make fire alarm system installed at Alipurduar District Hospital. | 726 | Each | 43 ₹31,218 | 40 ₹29,040 | 42 ₹30,492 |
| 6.01 | Checking & Testing of necessary cable and conduiting work for installed at Alipurduar District Dospital, Alipurduar as per latest Fire alarm guide line (IS2189/NBC/NFPA72). | 1 | Item | 2,100 ₹2,100 | 2,000 ₹2,000 | 2,050 ₹2,050 |
| 7.00 | Supply & Fixing 12 Volt, 7 AH SMF Battery (Make: Exide) | 8 | Nos | 3,100 ₹24,800 | 3,000 ₹24,000 | 3,050 ₹24,400 |
| 7.01 | Supply & Fixing of Manual Call Point Glass (Make: Siemens / Edwards) | 60 | Nos | 2,510 ₹1.5 L | 2,500 ₹1.5 L | 2,505 ₹1.5 L |
Tender Value
₹6.5 L
EMD Value
₹12,957
Closing Date
17 Feb 2026, 1:00 pmClosed
Executive Engineer Cooch Behar Electrical Division
Cooch Behar Electrical Division, Sunity Road, Circuit House Campus.A
Special Checking, Rectification, Testing and Re-Commissioning of Fire Detection Alarm System at Alipurduar DH.
2026_WBPWD_998137_1
WBPWD/EE/CED/eNIT-31/2025-2026
Open Tender
ELECTRICAL WORKS ORG
45 days
Alipurduar Hospital
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,957
Cooch Behar Electrical Division, Sunity Road, Circ
10 Mar 2026
3 Feb 2026
19 Feb 2026
3 Feb 2026
17 Feb 2026
10 Feb 2026
9 Feb 2026