Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 CrAdmitted-Finance PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARAHILLS HYDERABAD HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | ₹11.5 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | srico projects pvt ltd L1 |
|---|---|---|---|---|
| 1.00 | Schedule I | 1 | No | - |
| 2.00 | Schedule II | 1 | No | - |
| 3.00 | Schedule III | 1 | No | - |
| 4.00 | GST for bidders within TamilNadu
SGST in % | 1 | No | - |
| 5.00 | GST for bidders within TamilNadu
CGST in % | 1 | No | - |
| 6.00 | GST for bidders outside TamilNadu
(IGST) in % | 1 | No | - |
Tender Value
₹5.1 Cr
EMD Value
₹5.1 L
Closing Date
24 Feb 2020, 2:30 pmClosed
The Chief Engineer Civil Designs
The Chief Engineer Civil Designs IIIrd floor Eastern Wing NPKRR Maaligai No.144 Anna Salai Chennai 2
Construction of 2 Block of Q type quarters(12Nos)with Bore well elevated water tank sump tank septic tank car and two wheeler shed drainage formation of road and guard room at Bhavani Kattalai Barrage III Power House at Pasur Village Erode District
2020_EB_155362_1
CE/CD/SE/CD HP-04/2019-2020
Open Tender
Civil Works
365 days
Pasur Village
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹5.1 L
Yes
28 May 2020
23 Jan 2020
25 Feb 2020
23 Jan 2020
24 Feb 2020
29 Jan 2020
23 Jan 2020 - 21 Feb 2020
Amount
Schedule I
Schedule II
Schedule III
GST for bidders within TamilNadu SGST in %
GST for bidders within TamilNadu CGST in %
GST for bidders outside TamilNadu (IGST) in %
Description of Work / Item(s)
Amount
Providing 6Nos Bore holes for analysis of soil particulars by drilling 10mm dia bore holes with power boring machine in all classes of soils including sand, soft disintegrated rock, laterite deposite,medium rock,kankar including hard rock at specified locations including conducting SPT test at regular interval of 1.0m upto 10m depth at 1.5m regular interval beyond 10.0m depth and collection of disturbed and undistrubed samples, water tables and water analysis and submission of test results and foundation and recommendation in 6 copies. The boreholes may be terminated on obtaining three consecutive "N" values greater than 50 out of which third value must be greater than 100 and furnishing including design and preparation of construction drawings for foundation and super structure and all structural Reinforcement drawings for 2 Blocks 'Q' type Quarters - (12 Nos Tenements) in seismic Zone III as per the plan furnished by TANGEDCO for obtaining TANGEDCO approval for the same furnishing 10 hard copies and 2 soft copies of design and drawings to TANGEDCO before commencement of work at site.
Clearing Scrub and Light jungle and disposing off to a place at-least 1km away from the site as directed by the Engineer in charge including all Labour charges, Lead, Lift, T&Ps etc., complete.
Drilling 400mm dia hole for cast insitu pile foundation in soil up to a depth of 5m including transport of machinery, erection, removing and disposal of excavated soil, materials, lead, lift etc., complete as per specification and drawings.
Plain cement concrete 1:3:6 using 40mm size graded HBG stonebelow pile cap including cost of all materials, labour, curing charges, lead, lifts etc., complete.
RCC piles in M25 mix using 12mm to 20mm graded HBG stones including curing and labour charges, cost of all materials, lead, lifts etc., complete excluding cost of reinforcement.
RCC pile caps and grade beams in M25 using 12mm to 20mm graded HBG stones including formwork, curing and labour chargtes, cost of all materials, lead, lifts etc., complete but excluding cost of reinforcement.
Supplying and providing anti- termite protection (Pre-Construction) for the Foundation and Ground floor of the Building as per IS 6313 (Part II) including cost of all materials, Labour charges, Lead, Lift, T&Ps etc., complete.
Refilling with excavated earth well -watered and consolidated in layers of not more than 150mm thick in foundation and basement as directed by the Engineer in charge including all Labour charges, Lead, Lift, T&Ps etc., complete.
Supplying and filling river sand / M sand well- watered and consolidated in foundation and basement in layers complying with standard specification as directed by the Engineer in charge including cost of all materials, all Labour charges, Lead, Lift, T&Ps etc., complete.
Providing P.C.C. 1:4:8 using 40mm HBG metal for foundation and Basement as directed by the Engineer in charge including cost of all materials, labour charges, curing, T&P, leads, lifts etc., complete.
Providing RCC M25 mix for Footing and Plinth Beam using 12 to 20mm graded hard machine broken granite stone with minimum cement content of 300kg/M³ and maximum water cement ratio of 0.5 as directed by the Engineer in charge including form work, vibrating, centering, curing, cost of all materials, labour, lead, lift, etc. complete but excluding cost of steel reinforcement.
Providing R.C.C. Columns in M25 GRADE using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m³and maximum water-cement ratio of 0.5 as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Water Tank
Providing R.C.C. Lintels in M25 GRADE using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m³ and maximum water-cement ratio of 0.5 as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Providing R.C.C. Beams in M25 GRADE using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m³ and maximum water-cement ratio of 0.5 as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Water Tank
Providing R.C.C. Floor/Roof slab , Waist slab , Landing and steps in M25 GRADE using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m³ and maximum water-cement ratio of 0.5 as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Providing R.C.C. Sunshade, Loft and Cooking platform in M25 GRADE using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m³ and maximum water-cement ratio of 0.5 and using anti-corrosive admixture ‘CONCARE’ or equivalent as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Providing R.C.C. M25 GRADE for Base slab and walls of water tank using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m3 and maximum water-cement ratio of 0.5 and using water Proof admixture of approved make and quality as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Providing R.C.C. M25 GRADE Precast slab using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m3 and maximum water-cement ratio of 0.5 as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Providing and laying one layer of polythene sheet of 50microns over wall and below roof slab including cost of all materials, labour , lead, lift etc., complete.
Providing steel reinforcement for all RCC works including cutting, bending, binding, tying and placing in position including cost of steel, binding wire, lead, lift etc., complete as directed by the Engineer in charge
High strength deformed TMT Bars having characteristic strength of Fe 500 N/mm² of ‘TATA’ or ‘SAIL’ make or equivalent
Brick work in CM 1:6 using Chamber Burnt Bricks of size 23x11x7cm with minimum compressive strength of 75kg/cm² for basement and super structure as directed by the Engineer in charge including cost of all materials, scaffolding, labour charges, curing, Lead, Lift, T&P etc., complete.
Basement, ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
In Staircase Head room
Brick work in CM 1:4 using 115mmthick Chamber Burnt bricks of size 23 x 11 x 7 cm with compressive strength of 50kg/cm² for partition walls, side parapet walls of waist slab etc., as directed by the Engineer in charge including cost of providing 2 nos of 8mm dia MS/RTS rods at every 4th layer, cost of all materials, scaffolding, labour charges, curing, Lead, Lift, T&P etc., complete..
Ground floor up to Ist Floor slab
Above Ist floor slab up to IIFloor slab
Above IInd Floor slab up to Roof slab
Providing drops in Service verandah and staircase of 70mm thick with ferrocement in mix 1:1.5:3 using 6mm downgraded metal chips over chicken mesh of size 10mmx10mm of 20G as directed by the Engineer in charge including cost of all materials, Labour charges, curing, Lead, Lift, T&P etc., complete but excluding cost of reinforcement.
Providing waste duct of inner size 600x700mm in 115mm thick Brick work in CM 1:4 using chamber burnt Class II clay bricks of size 9”x41/2”x3” and plastering in CM 1:3, 12mm thick both inside and outside, providing MS flap Door of 10G thick of size 300x300mm with 1 No. aldrop as directed by the Engineer in charge including cost of providing 2 nos of 8mm dia MS/RTS rods at every 4th layer, cost of all materials, scaffolding labour charges, curing, Lead, Lift, T&P etc., complete.
Providing Garbage Collection pits of internal size 2000 X1200mm for an average depth of 1000mm in 115mm thick brick masonry in CM 1:4 using class II chamber burnt clay bricks over 100mmthick PCC 1:4:8 using 40mm HBG metal for foundation and plastered with CM 1:3, 12mm thick finished smooth inside and outside including cost of all materials, lead, lift, curing, back filling etc., complete.
Providing floor finish with vitrified ceramic tiles of approved make, colour and quality and of size 600x600x8mm over 10mm thick Cement mortar 1:3 bedding and pointing with same coloured cement in all floors including cutting chase in walls wherever required, cost of all materials labour charges lead, lift, curing T&P etc., complete.
Providing floor finish with vitrified ceramic anti-skid tiles of approved make, colour and quality and of size 200x200x7mm over 10mm thick Cement mortar 1:3 bedding and pointing with same coloured cement in all floors for Bath and Toilet cutting chase in walls wherever required, cost of all materials labour charges lead, lift, curing T&P etc., complete
Providing floor finish 25mm thick Granolithic floor finish in mix 1:1:2(one part of cement ,one part of sand & two part of chips) using chips of grade 10 mm and below for portico floor as directed by the Engineer in charge including cost of all materials labour charges lead, lift, curing T&P etc., complete using machine for finishing.
Dadooing the walls with ceramic glazed tiles of approved make , colour and quality and size 300x300x6mm over 10mm thick CM 1:3 bedding and pointing with same coloured cement in all floors for Bath, toilet and above kitchen platform including cutting chase in walls wherever required, finishing neat cost of all materials, labour, lead, lift, curing etc., complete
Plastering in CM 1:3, 10mm thick for all ceiling surfaces, Sunshades, Lofts, bottom of waist slab etc., including cost of all materials, scaffolding charges, Labour charges, curing, Lead, Lift, T&P etc., complete
Plastering in CM 1:5, 20mm thick for exterior surfaces of all walls including cost of all materials, scaffolding charges, Labour charges, curing, Lead, Lift, T&P etc., complete
Plastering in CM 1:5, 12mm thick for interior surfaces of all walls including cost of all materials, scaffolding charges, Labour charges, curing, Lead, Lift, T&P etc., complete
Floor finishing in CM 1:3, 12mm thick for top of waist slab, Steps and Service Verandah etc., including cost of all materials, labour charges, leads, lifts, curing, etc, complete.
Supplying and fixing in position Flush Doors of required size with pressed steel door frame of size 105x60mm, 18 gauge as per IS 4351-2003 with single leaf factory made flush type shutter of 30mm thick using particle board stamped IS 3087-1985/Type-I with ‘E’ type T.W. beading bonded with water resistant adhesive fixed to the pressed steel door frame with following fixtures, i) Hold fasts of size 35x35 x5mm, length 300mm-6Nos, ii)Steel aldrop 250mm long-1No. iii)Anodised Aluminium Handle 100mm long-2 Nos, iv)Anodised Aluminium towerbolts 200x12mm-2Nos, v)Door stopper-1No. vi)Oxidised iron Butt hinges-3Nos, vii)Rubber Bush-1No, viii)Safety chain-1No, ix)Metallic magic eye-1No, x)Auto Lock -1No including cost of transporting, lifting and fixing ,embedding the hold fasts in walls rigidly with concrete PCC 1:2:4 ,cost of all materials, labour charges, Lead, Lift, T&P etc., complete
For Entrance Door
For inner Doors-same as above but without safety chain, metallic magic eye and Auto Lock.
Supplying and fixing in position of partly paneled and partly glazed Mild Steel Windows of required size using 23x18x18x3mm ‘Z’ section for window main frame, 46x23x20x3mm ‘J’ section for Intermediate frame, 23x18x18x3mm ‘Z’ section for shutter frame with 4 / 6 leaves top leaves glazed with 4mm thick pin head glass, bottom leaves paneled with MS sheet of 16Gauge, with 10MM squqre bar grill arrangements at 100mm c/c with 4 Nos of hold fasts , handle pulleys, latches with locking arrangement including cost of fabrication , transporting , lifting and fixing ,embedding the hold fasts in walls rigidly with concrete PCC 1:2:4 ,cost of all materials, labour charges, Lead, Lift, T&P , one coat of red oxide primer etc., complete.
Supplying and fixing in position of mild steel grills for Service verandah and staircase landind with MS angle 25x25x3mm alround frame, 25x5mm MS flat intermediate frame using 10mm square bars at 100mm c/c as per approved design and as directed by the Engineer in charge with adequate nos of holdfasts to fix the grill inside the walls rigidly including cost of fabrication , transporting , lifting and fixing ,embedding the hold fasts in walls rigidly with concrete PCC 1:2:4 ,cost of all materials, labour charges, Lead, Lift, T&P , one coat of red oxide primer etc., complete
Supplying and fixing of Laminated PVC single leaf door ‘SINTEX’ make or equivalent of approved colour and quality with shutter and PVC frame of size 2100x750mm with 19x19mm for styles and 15x15mm for top and bottom rails and covered with PVC channel of size 50x30mmend caps with 5mm thick PVC sheet with 3 Nos 100mm Aluminium butt hinges, 2 Nos 150mm anodized Aluminium handles ,2 Nos Anodised Alumium 200x12mm tower bolt and 1 Nos. 200mm Aldrop, 6 Nos iron hold fasts of size 230x50x5mm etc., for Bath and toilet including cost of transporting, lifting and fixing, cost of all materials, labour charges including fixing, lead, lift etc., complete.
Supplying and fixing of Aluminum anodized Louvered ventilator of required size, the outer frame in Aluminum Box section 62x38x2mm @1.1kg/m, the louvers with moving arrangements in Alu channel of size 60x30x4mm @ 1.27kg/m with necessary pinhead glass pans of 4mm thick Louvers, Al. clips including chipping, dismantling/making holes in masonry/Concrete wherever necessary and make good the disturbed area to the original condition after fixing, cost of all materials labour charges, lead, lift, fixing charges, Transport T&P etc., complete . The Aluminum surface is to be anodized with matt finish of not less than 15microns thick anodic film and in accordance with IS 1868-1962.
Supplying and fixing fully panelled country wood Cup board of required size in bed and kitchen in all floors as directed by the Engineer in charge using factory made CW frame (75x32mm) and CW shutter using 12mm thick particle board of ISI stamped and providing 3 tiers of 25mm thick double side polished cuddappa slab for shelves including cost of all materials labour charges fixing charges, required fixtures and fittings to the cupboard such as padlock, tower bolt etc., lead, lift and, 2 coats of solignum for portions and wood work in contact with masonry etc., complete
Supplying and fixing partly panelled and partly glazed country wood Cup board of required size as directed by the Engineer in charge using factory made CW frame (75x32mm) and CW partly panelled and partly glazed shutters using 12mm thick particle board of ISI stamped and 4mm thick plain glass of good quality and providing 3 tiers of 25mm thick double side polished cuddappa slab thick for shelves including cost of all materials labour charges fixing charges, required fixtures and fittings to the cup board such as padlock, tower bolt etc., lead, lift and, 2 coats of solignum for portions and wood work in contact with masonry etc., complete..
Supplying and laying of cuddappa slab 25mm thick single side polished for kitchen platform over a bed of CM 1:3 20mm thick making chase in walls, finishing to the original condition including cost of all materials labour, lead, lift, curing etc., complete.
Supplying and providing 1 No cuddappa sink polished of size 600x600x450 mm adjacent to kitchen platform including cost of materials such as 32mm dia ‘B’ Class G.I. waste water pipe, 32mm dia C.P. waste coupling and Bottle trap labour, making chase in walls finishing to the original condition, led, lift and curing etc., complete.
Supplying and fixing Indian water closet of size 530x410mm Parry Ware make or Equivalent of approved quality and colour with ‘P’ or ‘S’ trap conforming to IS 2556-Part XII with 10 lit capacity PVC low level Cistern tank, packing the joints of the closet with the traps with asbestos rope using cement mixed with approved water proof compound, laying the closet over sand cushion and forming flooring around the closet using 40mm broken jelly in lime concrete 1:2:5(One part of Lime, two part of sand and five part of brick jelly) of 100mm thick and finishing the top to required slope, connecting to soil pipes by dismantling the brick masonry/RCC slab making good the disturbed portion to original condition and finished water tight without leakage complying with standard specification as directed by the Engineer in charge including cost of all materials, Transporting, all labour, lead, lift, , T&P etc., complete.
Supplying and fixing approved make light coloured glazed wash basin of make Parry ware or Equivalent of size 500x400mm mounted on wall supported over GI brackets screwed with walls rigidly, with necessary fixtures 1 No. CP Nose pillar tap, waste coupling, 32mm waste hose, 1No.gate valve, I/2” connecting hose and bottle trap etc.,., finishing the disturbed masonry neat including cost of all materials, transporting, labour, lead, lift, etc., complete.
White washing with two coats of white cement for ceiling surfaces including cost of all materials, scaffolding, Labour, Lead, Lift etc., complete
Colour washing with two coats of Oil Bound distemper over a coat of water based primer for interior surfaces including cost of all materials, scaffolding, Labour, Lead, Lift etc., complete
Colour washing with two coats of Cement paint over a coat of white cement for the exterior surfaces including cost of all materials, scaffolding, Labour, Lead, Lift etc., complete.
Providing one course of best pressed tiles of size 230x230x20mm as weathering course for roof slab embedded in 12mm thick Cement mortar 1:3 mixed with crude oil @ 10% by weight of cement over a bed of brick jelly in pure slacked lime in the ratio of 32:12.5 (32 parts of Brick jelly to 12.5 part of lime) to an average thickness of 80mm laid with required slope well beaten with wooden mallet and pointed with the same oiled mortar including cost of all materials, Labour, Lead, Lift etc., complete
Supplying and fixing in position of 110mm dia PVC pipe (4Kg/cm2) of FINOLEX or equivalent approved make and quality with ISI monogram as directed by the Engineer in charge for Downfall Pipes including cost of all materials, all specials such as Tees, Elbow, shoes, clamps , bends and screws ,gratings etc., making holes in masonry/concrete ,restoring the disturbed area to original condition, making water tight jointing with no leakage, Labour , scaffolding, Lead, Lift etc., complete
Supplying and fixing in position of 110mm dia PVC sewer pipe (6Kg/cm2) of approved make and quality with ISI monogram as directed by the Engineer in charge for sewer pipes including cost of all materials, all specials such as Tees, Elbow, shoes, U clamps , bends and screws ,gratings, wooden plugs etc., making holes in masonry/concrete ,restoring the disturbed area to original condition, making water tight jointing with no leakage, Labour , scaffolding, Lead, Lift etc., complete
Supplying and fixing in position of 90mm dia PVC pipe (6Kg/cm2) of FINOLEX make or equivalent approved make with ISI monogram and quality as directed by the Engineer in charge for waste water Pipes including cost of all materials, all specials such as Tees, Elbow, shoes, U clamps , bends and screws ,gratings etc., making holes in masonry/concrete ,restoring the disturbed area to original condition, making water tight jointing with no leakage, Labour , scaffolding, Lead, Lift etc., complete
Supplying and laying in position of UPVC pipe line of medium class ( B class) of ASTRAL make or equivalent conforming to IS 1239 as directed by the Engineer in charge for water supply arrangements including cost of all materials, specials such as Tees, bends, Couplings, screws cutting , threading, joining, specials, TW plugs, packing and wrapping the pipe laid underground with hessian cloth and tarring and fixing the pipe above ground to walls with galvanized iron clips lead, lift etc., complete.
50mm dia UPVC ‘B’ class pipe:
25mm dia UPVC ‘B’ class pipe:
20mm dia UPVC ‘B’ class pipe:
Supplying and fixing Gun Metal gatel valve of ISI make (Heavy duty)as approved by the Engineer in charge including cost of all materials labour charges for fixing etc., lead, lift etc., complete.
Gun Metal gate valve 50mm Dia.
Gun Metal gate valve 25mm Dia.
Gun Metal gate valve 20mm Dia.
Supplying and fixing of 20mm dia CP screw down bib cock of ISI make as directed by the Engineer in charge including cost of all materials, labour charges for fixing, lead, lift etc., complete.
Supplying and fixing in position of Brass CP shower of 100mm dia with CP gate valve (Heavy Duty) of size 20mm dia in bath rooms as directed by the Engineer in charge including cutting, threading, jointing etc., complying with standard specifications , cost of all materials, labour charges for fixing, all lead, lift etc., complete
Supplying and fixing PVC Nahini trap of size 75mmx50mm with stainless steel grating of approved brand and quality fixed over a bed of brick jelly lime concrete including dismantling masonry works and making good the damaged portions to the original condition with finishing in cement mortar including cost of all materials, labour charges, curing, all lead, lift etc., complete.
Supplying and fixing of best quality Aluminium anodized Towel rod of 20mm dia pipe, length 750mm with 2Nos CP brackets at corner in the bath room in all floors including cost of all materials, labour for fixing, lead, lift with necessary teak wooed plug, CP screws and dismantling masonry and rectifying the same to original condition etc., complete.
Painting the steel work with two coats of approved quality colour enamel paint over a coat of primer of red oxide including cost of all materials, brushes, lead, lift etc., complete.
Painting to the wood work with two coats of approved quality colour enamel paint over one coat of approved wood primer including cost of all materials, brushes, lead, lift etc., complete
Providing plinth protection alround the building for a width of 1m from the face of the basement wall by laying PCC 1:4:8 using 40mm HBG metal for an average thickness of 100mm and plastered over with CM 1:3, 12mm thick and the finished surface is to have a slope away from the plinth to drain water from down fall pipes with slope towards rain water harvesting structure as directed by the Engineer in charge including cost of all materials, labour charges, curing, lead, lift etc., complete.
Providing open brick masonry drain of inner width 150mm and average height 200mm around plinth protection using fly ash brick masonry, 115mm thick in CM 1:4 and plastered inside and outside and top with CM 1:3, 12mm thick over 75mm thick PCC 1:4:8 using 40mm HBG metal and to suit the gradient of the drain as directed by the Engineer in site including cost of all materials labour charges, curing charges, lead, lift etc., complete.
Providing inspection chamber (Manhole) of size 450 x 450mm internal size for an average depth of 900mm (150mm above G.L.) in brick masonry 230mm thick in CM 1:4 using chamber burnt bricks over 100mmthick PCC 1:4:8 using 40mm HBG metal for foundation and plastered with CM 1:3, 12mm thick both inside and outside the manhole and fixing C.I Manhole cover of size 600x600 mm with all-round frame, benching inside the chamber including cost of all materials, lead, lift, curing, back filling etc., complete.
Supplying and providing Rain water harvesting arrangement by providing peculation pit of size1.20 x 1.20 x 1.50M height including 1.20m depth of earthwork excavation , 900mm depth filling with 40mm metal , 230mm depth sand filling , all-round brick work 230mm thick ,450mm height in CM 1:4 using chamber burned bricks over PCC 1:4:8,100 thick as directed by the engineer at site. including cost of all materials, excavation of earth work, PCC , labour charges, lead, lift, curing and back filling etc., complete.
Supply and fixing of horizontal type 4 Way Triple Pole neutral MCB Distribution board in sheet steel enclosure with 40A FP Isolator (MCB), 40A FP ELCB 30MA as incoming and 12 Nos. 6A - 32A single pole MCB as out going in flush with wall and making good of the concealed portion with earth connection. The MCB DB, ELCB and MCBs should be with ISI mark (Legrand (MDS) / Hager (L&T) make) including cost of all materials such as cables, pipes, etc, complete
Supply and fixing of TANGEDCO meter Board suitable for 50A Three phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1”x1/8” Copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1”thick on either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 6Sq.mm PVC insulated copper wire from TANGEDCO meter to fuse unit including cost of all materials labour, lead, lift etc, complete.
Supply and fixing of 3 Phase 4 wire 4Way ICDB 32A per way with 100A TPN MC Switch with suitable trunking box MS cable entry boxes and internal connection on sutiable angle iron frame work withh earth connections including cost of all materials, labour, lead, lift etc, complete.
Supply and fixing of 16A DP Switch with metal clad (side handle) of 500V with fuse unit and neutral on suitable TW Box with earth connections including cost of all materials, labour, lead, lift etc, complete.
Earthing as per PWD standard with an earth electrode of 2M class B GI pipe of dia not less than 32mm complete with neceesary masonry work including cost of all materials, labour, lead, lift etc, complete.
Wiring with 2 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling for lights,fan and buzzers with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color of PVC concealed light point / Fan point / Buzzer switch should be at the main entrance of each flat with 5amps F.T. switch, ceiling rose, cable, pipe, labour, lead etc complete.
Wiring with 3 x 2.5 sq.mm (36/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch (Two way) with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color of PVC concealed stair case light point with 5amps F.T. switch, ceiling rose, cable, pipe, labour, lead etc complete.
Wiring with 2 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor of cable 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150x100x113mm TW switch box with 3mm thick hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color for concealed PVC plug point cable, pipe, labour, lead etc complete.
Wiring with 2 x 4 sqmm (56/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150x100x113mm TW switch box with 3mm thick hylum sheet cover for 15 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color for concealed PVC plug point including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supplying and run of 4 of 6 Sqmm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Cromton/ K.lite) suitable for CFL lamp with 15 W bulb including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of fancy glass shade and 15W CFL Lamp for BH point including cost of all materials such as cables, pipes, etc, labour, lead etc, complete.
Supply and fixing of 15W CFL Lamp for BH point including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of single box type 4' x 40W flu fitting complete with copper choke and condensor (Philips / Crompton / Wipro) with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of 1200mm (48") AC ceiling fan confirming to ISS 374 /1979 (Bajaj / Crompton / Usha) complete with stepped electronic 300W regulator with down rod on the existing clamp including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of AC/DC 76mm Buzzer/call bell suitable for 230 volts 50 C/S single phase AC supply on suitable TW Board with push switch including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing 300mm (12”) sweep (light duty) confirming to IS (Bajaj / Crompton / Almonad) AC Exhaust fan complete with necessary wall opening and making good of the wall including cost of all materials such as cables, pipes, labour, lead etc, complete.
Wiring for Telephone (intercom) line in suitable PVC rigid pipe concealed in wall and ceiling for intercom plug with PVC accessories in flush with wall with 100 x 150 x 113 mm TW / Metal box with sheet cover for intercom female plug including supplying and fixing of all materials making good of the concealed portion with suitable colour for concealed PVC plug point, PVC pipe, plugs, labour, lead etc, complete.
Description of Work / Item(s)
Amount
Clearing Scrub and Light jungle and disposing off to a place at-least 1km away from the site as directed by the Engineer in charge including all Labour charges, Lead, Lift, T&Ps etc., complete.
Providing and laying gravel for raising the ground level to the required line, grade and level compacted to 95% of modified proctomax only density using 8 - 10t Power roller and as per technical speciication etc., complete including all leads, lifts, labour etc., complete as directed by the departmental Engineer etc., complete.
Drilling 400mm dia hole for cast insitu pile foundation in soil up to a depth of 5m including transport of machinery, erection, removing and disposal of excavated soil, materials, lead, lift etc., complete as per specification and drawings.
Plain cement concrete 1:3:6 using 40mm size graded HBG stonebelow pile cap including cost of all materials, labour, curing charges, lead, lifts etc., complete.
RCC piles in M25 mix using 12mm to 20mm graded HBG stones including curing and labour charges, cost of all materials, lead, lifts etc., complete excluding cost of reinforcement.
RCC pile caps and grade beams in M25 using 12mm to 20mm graded HBG stones including formwork, curing and labour chargtes, cost of all materials, lead, lifts etc., complete but excluding cost of reinforcement.
Providing RCC M25 mix for Footing and Plinth Beam using 12 to 20mm graded hard machine broken granite stone with minimum cement content of 300kg/M³ and maximum water cement ratio of 0.5 as directed by the Engineer in charge including form work, vibrating, centering, curing, cost of all materials, labour, lead, lift, etc. complete but excluding cost of steel reinforcement.
Earth work excavation in all classes of soils for water line and sewer line for 'Q' type quarters in hard stiff clay, stiff block cotton hard red earth, shales, murram, gravel stoney earth, and earth mixed with samll size boulders and hard gravelly soil with an initial lead of 10m and lift of 2m including cost of all materials, lead and lift etc., complete and directed by Engineer at site.
Providing P.C.C. 1:4:8 using 40mm HBG metal for foundation and Basement as directed by the Engineer in charge including cost of all materials, labour charges, curing, T&P, leads, lifts etc., complete.
Providing Random Rubble masonry in CM 1:6 for foundation wall using quarry stone including cost of materials, leads, lifts, labour and curing charges etc., complete.
Refilling with excavated earth well -watered and consolidated in layers of not more than 150mm thick in foundation and basement as directed by the Engineer in charge including all Labour charges, Lead, Lift, T&Ps etc., complete.
Flush pointing in CM 1:5 including cost of all materials, labour, curing charges, all leads and lifts etc., complete and as directed by Engineer at site.
Plastering in CM 1:5, 20mm thick for interior surfaces of all walls including cost of all materials, scaffolding charges, Labour charges, curing, Lead, Lift, T&P etc., complete
Supplying and filling river sand / M sand well- watered and consolidated in foundation and basement in layers complying with standard specification as directed by the Engineer in charge including cost of all materials, all Labour charges, Lead, Lift, T&Ps etc., complete.
Brick work in CM 1:6 using Chamber Burnt Bricks of size 23x11x7cm with minimum compressive strength of 75kg/cm² for basement and super structure as directed by the Engineer in charge including cost of all materials, scaffolding, labour charges, curing, Lead, Lift, T&P etc., complete.
Providing R.C.C. Floor/Roof slab , Waist slab , Landing and steps in M25 GRADE using 12mm to 20mm graded HBG metal with minimum cement content of 300kg/m³ and maximum water-cement ratio of 0.5 as directed by the Engineer in charge including cost of form work, centering and shuttering, cost of all materials, labour charges, vibrating the concrete, curing , all T&P, lead, lift etc., complete but excluding cost of steel reinforcement
Providing steel reinforcement for all RCC works including cutting, bending, binding, tying and placing in position including cost of steel, binding wire, lead, lift etc., complete as directed by the Engineer in charge High strength deformed TMT Bars having characteristic strength of Fe 500 N/mm² of ‘TATA’ or ‘SAIL’ make or equivalent
Plastering in CM 1:3, 10mm thick for all ceiling surfaces, Sunshades, Lofts, bottom of waist slab etc., including cost of all materials, scaffolding charges, Labour charges, curing, Lead, Lift, T&P etc., complete
Floor finishing in CM 1:3, 12mm thick for top of waist slab, Steps and Service Verandah etc., including cost of all materials, labour charges, leads, lifts, curing, etc, complete.
White washing with two coats of white cement for ceiling surfaces including cost of all materials, scaffolding, Labour, Lead, Lift etc., complete
Colour washing with two coats of Cement paint over a coat of white cement for the exterior surfaces including cost of all materials, scaffolding, Labour, Lead, Lift etc., complete.
Supplying and fixing in positiion of MS gate of middle pad-lock provisions including two coats of enamel painting subject to approval of Engineers including cost of all materials, labour, lead, lift etc., complete.
Fabrication and erection of Roofing for Car Shed and two wheeler shed using PPGL sheet of 0.44mm thick powder coated roll forming and roof truss including cost of all materials required for frame work, all lead, lift, transporting, labour etc., complete.
PCC M20 design mix concrete using cement content of 300 Kg/m3 with 12-20mm down graded HBG stone, including cost of all materials labour, curing charges, lead, likfts etc., complete for foundation.
Construction of inspection chamber of size 600x 600 internal size for an average depth of 600mm (150mm above GL) in brick masonry in CM 1:5 using country bricks and plastered with CM 1:3, 12mm thick and finished smoth inside the manhole including cost of all materials, labour, scaffolding charges, curing charges, all leads and lifts etc., complete and as directed by Engineer at site.
Filling the dispersion trench using 40mm metal including cost of all materials, labour charges, all lead and lift etc., complete.
Filling the dispersion strench using 50% of the highest of the trench using sand including cost of all mateials, leads & lifts etc., complete and as directed by Engineer at site.
Conducting Geophysical survey by using water divining equipment for fixing the borewell point by ground water Geological sub division PWD.
Drilling of 150mm dia borewell including cost of all materials, labour charges for drilling etc., hire charges for plant & machinery including cost of all lead & lift transport charges, etc., complete.
Supply and errection of PVC casing pipe 150mm Kg/cm2 ISI make in the borewell including cost of pipe, erection charges, transporting charges etc., complete.
Supplying and laying in position of UPVC pipe line of medium class ( B class) of ASTRAL make or equivalent conforming to IS 1239 as directed by the Engineer in charge for water supply arrangements including cost of all materials, specials such as Tees, bends, Couplings, screws cutting, threading, joining, specials, TW plugs, packing and wrapping the pipe laid underground with hessian cloth and tarring and fixing the pipe above ground to walls with galvanized iron clips lead, lift etc., complete.
50mm dia UPVC ‘B’ class pipe:
65mm dia UPVC ‘B’ class pipe:
75mm dia UPVC ‘B’ class pipe:
Supplying and fixing in position of 110mm dia PVC sewer pipe (6Kg/cm2) of approved make and quality with ISI monogram as directed by the Engineer in charge for sewer pipes including cost of all materials, all specials such as Tees, Elbow, shoes, U clamps , bends and screws ,gratings, wooden plugs etc., making holes in masonry/concrete ,restoring the disturbed area to original condition, making water tight jointing with no leakage, Labour , scaffolding, Lead, Lift etc., complete
Supplying and fixing of 5 HP Texmo RF 15/37 submergible pump including erection charges, cost of control panel, electric cable and all other accessories etc., complete (For Borewell)
Supplying and erection of 5 HP Aquatech high speed Mono block motor (For sump) wityh starter including erection charges, cost of electric cable and all other accessories etc., complete.
Supplying and fixing Gun Metal ball valve of ISI make (Heavy duty)as approved by the Engineer in charge including cost of all materials labour charges for fixing etc., lead, lift etc., complete.
Gun Metal ball valve 50mm Dia.
Gun Metal ball valve 65mm Dia.
Gun Metal ball valve 75mm Dia.
Supply of NP2 RCC Hume pipes of each 2500mm length conforming to IS 458 and laying in of maximum depth of 2m to the required gradient and alignment as directed by the Engineer at site, Joining the pipes with cement using Spun yard, Jute thread etc. including cost of pipe and joining materials, cement loading, unloading at site all labour lead lift etc., complete.
600mmdia
300mmdia
Supply and fixing of horizontal type 4 Way Triple Pole neutral MCB Distribution board in sheet steel enclosure with 40A FP Isolator (MCB), 40A FP ELCB 30MA as incoming and 12 Nos. 6A - 32A single pole MCB as out going in flush with wall and making good of the concealed portion with earth connection. The MCB DB, ELCB and MCBs should be with ISI mark (Legrand (MDS) / Hager (L&T) make) including cost of all materials such as cables, pipes, etc, complete
Supply and fixing of TANGEDCO meter Board suitable for 50A Three phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1”x1/8” Copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1”thick on either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 6Sq.mm PVC insulated copper wire from TANGEDCO meter to fuse unit including cost of all materials labour, lead, lift etc, complete.
Supply and fixing of 3 Phase 4 wire 4Way ICDB 32A per way with 100A TPN MC Switch with suitable trunking box MS cable entry boxes and internal connection on sutiable angle iron frame work withh earth connections including cost of all materials, labour, lead, lift etc, complete.
Supply and fixing of 16A DP Switch with metal clad (side handle) of 500V with fuse unit and neutral on suitable TW Box with earth connections including cost of all materials, labour, lead, lift etc, complete.
Earthing as per PWD standard with an earth electrode of 2M class B GI pipe of dia not less than 32mm complete with neceesary masonry work including cost of all materials, labour, lead, lift etc, complete.
Wiring with 2 x 2.5 sq.mm (36/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling for light, fan & Buzzers with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color of PVC concealed light point /Fan point/ Buzzer switch should be at the main enterence of each flat with 5amps F.T. switch, ceiling rose, cable, pipe, labour, lead etc complete.
Wiring with 3 x 2.5 sq.mm (36/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch (Two way) with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color of PVC concealed stair case light point with 5amps F.T. switch, ceiling rose, cable, pipe, labour, lead etc complete.
Wiring with 2 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor of cable 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150x100x113mm TW switch box with 3mm thick hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color for concealed PVC plug point cable, pipe, labour, lead etc complete.
Wiring with 2 x 4 sqmm (56/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150x100x113mm TW switch box with 3mm thick hylum sheet cover for 15 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color for concealed PVC plug point including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supplying and run of 4 of 6 Sqmm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Cromton/ K.lite) suitable for CFL lamp with 15 W bulb including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of fancy glass shade and 15W CFL Lamp for BH point including cost of all materials such as cables, pipes, etc, labour, lead etc, complete.
Supply and fixing of 15W CFL Lamp for BH point including cost of all materials such as cables, pipes, labour, lead etc, complete.
Supply and fixing of single box type 4' x 40W flu fitting complete with copper choke and condensor (Philips / Crompton / Wipro) with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals including cost of all materials such as cables, pipes, labour, lead etc, complete.
Wiring for Telephone (intercom) line in suitable PVC rigid pipe concealed in wall and ceiling for intercom plug with PVC accessories in flush with wall with 100 x 150 x 113 mm TW / Metal box with sheet cover for intercom female plug including supplying and fixing of all materials making good of the concealed portion with suitable colour for concealed PVC plug point, PVC pipe, plugs, labour, lead etc, complete.
Description of Work / Item(s)
Amount
Providing and laying earth for raising the grade level to the required line , grade and level completed to 95% of modified proctmax dry density using a 10T power roller and as per technical specification etc,. Complete including cost of all lead & lift , labour etc,. complete and as directed by the departmental Engineer etc,. complete.
Providing and laying bottom layer of water bound machadam (WBM) 75mm compacted thickness using course aggregate of grade-II metal of 0.41m3 of 63mm metal , 0.39m3 of 53mm metal and 0.20m3 of 45mm metal with 0.24m3 of gravel for 10m2 for blindage including cost of conveyance of all materials and stacking them at the site of departmental guage or pre-measurement , labour charges for spreading metal and gravel mix , hand packing to chamber watering with all leads and compaction by 80-100 KN power roller water sprinkler and all tools and plants deployed , barricading etc,. complete.
Providing and laying second layer of water bound machadam (WBM) 75mm compacted thickness using course aggregate of grade -III metal of 0.36 m3 of 53mm metal 0.35m3 of 45mm metal and 0.29m3 of 22.40mm metal with 0.24m3 of gravel for 10m2 for blindage including cost of conveyance of all departmental guage for pre-measurement labour charges for spreading metal and gravel mix , hand packing to chamber , watering with all leads and compaction by 80-100 KN power roller water sprinkler and all tools and plants deployed , barricading etc,.complete,.
Providing and laying tack cost using bitumen emulsion of 4Kg for 10m2 over the WBM surface ,preparation to another cost of all materials , labour charges , all leads & lift etc,. Complete .
Providing and laying bitumen macaadam of 50mm thickness which consisth of construction in a single course of compacted crushed aggregates premixed with bitumen binding 60/70 grade at the rate of 3.5% by weight of total mix to serve as base for binder course in accordance with the requirem,ent of the specification and in conformity as directed by the Engineer incharge.
Providing and laying tack coat using bitumen emulsion of 3kg for 10m2 over the BT surface , preparation to another bitumen construction over it , including bitumen construction over it , including cost of all materials , labour charges , all leads & lifits etc,.complete,.
Providing and laying 25mm thick compascted semidense bitumen mix with seal coat which shall consists of construction of a single course binder wearing course on a previous prepared bitumen base to the required specification .
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_186521.xls
BOQ • 0.52 MB
SpecnVol-I.pdf
Tender Documents • 3.44 MB
Download all tender documents and submit your bid