Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
28 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
SPL REPAIR TO BLDG NO P-77, P-78, P-254 AND P-255 AT HAFT CHINAR UNDER GE 970 EWS
2023_MES_579333_1
GE 970 EWS-71/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹42,000
Yes
3 Mar 2023
6 Feb 2023
2 Mar 2023
6 Feb 2023
28 Feb 2023
21 Feb 2023
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/blankets, any thickness any type, complete all as specified and directed.
M&L 4 mm thick Veneered plywood, grade 1 (with BWR resin) with decorative face veneers on only one face fixed with nails to timber frame work as in wall and ceiling complete all as specified.
Hollow PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
M&L in repairs for 25mm thick 2nd class hardwood Boarding in Floors and Skirting, Planed one side, with butt joints and fixed with nails supplied and fixed complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles, complete all as specified and directed.
Material & labour for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Rendring 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of alkali resistant primer complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plaster surface of wall and applying 2mm thick wall care putty complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coat of cement base paint complete all as specified and directed.
M& L for applying two coat of Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) as specified and directed.
Rendering 5mm thick in cement plaster 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Taking down chowkats or frames not exc 1.5 Sqm each with shutters (without taking off shutters from the frames). complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
Taking down Shutters of any description n exc 1 sqm each complete all as specified and directed
Taking down Shutters of any description exc 1.0 sqm and n.exc 2 sqm each complete all as specified and directed
S&F factory made 2nd class hardwood, 30mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S&F 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, cut or mitred beads for screwing glass etc. Sizes of members of shutters as specified in SSR Part - I, Section 8, Clause 8.20(b) complete all as specified and directed.
Supply and fixing solid PVC door frame of size 50mm x47mm made out of 5mm plain clour PVC sheet reinforced with MS square tube, in opening as per specification and drawing, complete all as specified and directed.
Factory made solid panel PVC moulded door shutter with particle board core 28 to 30 mm thick (stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on front face and 2 mm thick plain color PVC sheet on back face supply and fixing in frame at site as per specification and drawing, complete all as specified and directed.
S&F butt hinges med weight cold rolled MS, size 100 mm complete all as specified and directed.
M&L in repair for Framed work of Fe 410-W (Gde E- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for PCC 1:3:6 type C-0 using 12.5 mm graded crushed stone aggregate as in back filling, coping, hold fasts, complete all as specified.
Preparation of new wooden surfaces and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preparation of old wooden or wooden based surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material & labour Aluminium handles, D type, anodized 150 mm long ISI Marked, complete all as specified and directed.
150mm long aluminum anodised barrel tower bolts of extruded section ISI Marked, complete all as specified and directed.
Aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 300mm long dia 16 mm complete.ISI Marked, complete all as specified and directed.
Mild Steel 300mm, ordinary rat tail rod pattern springs,incl roller and roller plate complete. ISI Marked,complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sq.m in each pane, complete all as specified and directed.
S& F Galvanished MS wire cloth 0.56mm nominal dia or wire and average width of aperture 1.18 fixed with tinned tacks or galvanished wire staples complete all as specified and directed.
S& F in repair Galvanished MS wire cloth 0.56mm nominal dia or wire and average width of aperture 1.18 fixed with tinned tacks or galvanished wire staples complete all as specified and directed.
M&L for 25mm thick Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub-floors, sub-bases, and pavings etc complete all as specified and directed
Dismantling of floor, hearth or wall tiling including cement mortar bedding/backing etc, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material & labour for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6, complete all as specified and directed.
Material & labour for coloured non skid ceramic tiles 7 to 8 mm thick, jointless, area of each tile exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match shade of tile complete all as specified and directed.
M&L Non-Skid ceramic coloured tiles 7 to 8 mm thick (square/reactangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in floor finishes set and joineted in neat cement slurry and pointed in white or colured cement to match shade of tiles complete all as specified and directed. complete all as specified.
Rendering 10mm thick in CM 1:4 on stone masonary surfaces, other than fair faces of brick work finished even and fair to receive tiles complete all as specified and directed.
Material & labour for Glazed ceramic tiles in vertical surface 350mmx 250mmx 7mm/ 450mmX 350mmX 7mm thick such as skirting, dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match pattern and shade complete all as specified and directed.
Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 25mm dia ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball etc complete including taking out existing water tanks of any description complete all as specified & directed.
Supply and fixing in repair vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rest including trap, PVC flushing pipe and anti-syphonage pipe including PVC valveless, syphonic action, flushing cistern 10 ltr capacity, low level, white, with inlet ball valve, float and handle including brackets, complete all as specified and directed.
Supply and fixing in repairs vitreous china wash basin (Padestal pattern), white, flat back, size 600 x 480 mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste coupling, complete all as specified and directed.
Supply and fix in repair PVC connection with brass ferrules, 60 cm long for wash basins and flush tanks complete all as specified and directed.
Supply and fixing in repair Low density polythylene (LDPE) Waste pipe 32mm bore, 900mm long, complete all as specified and directed.
Supply and fixing in repair 15mm bore bib tap long nose/long body cast copper alloy CP fancy type with capstan head handle,screwed down, screwed for brass, weight n ot less than 450 gms ferrule and fixed, complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete of bore 15mm complete all as specified and directed.
S&F galvanised mild steel water tubes,15 mm bore with all fittings, 'medium grade', ISI marked, galvanised, fixed to walls and ceiling or laid in floors complete all as specified.
Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete of bore20 mm complete all as specified.
S&F galvanised mild steel water tubes,20mm bore with all fittings, 'medium grade', ISI marked, galvanised, fixed to walls and ceiling or laid in floors complete all as specified.
Supply and fix in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement, diameter of outlet 75mm complete all as specified and directed.
M&L for Lagging to 15mm GI pipes used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed with puff insulation chicken wire mesh wire netting 25 gauge, 20mm mesh complete all as specified and directed.
M&L for Lagging to 20mm GI pipes used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed with puff insulation chicken wire mesh wire netting 25 gauge, 20mm mesh complete all as specified and directed.
Supply and fixing in repair 15mm bore stop/angle cock, cast copper alloy CP, fency type high presure with capstan head handle,wt n less than 450 gms screwed both ends for iron pipe of for unions complete all as specified and directed.
Supply and fixing in repair 110mm PVC, SWR pipes, single socketed in any length with rubber ring joint lead in trenches or in floor, complete all as specified and directed.
All as per item no.60 above but 75mm bore pipe ---ditto---
Supply and fixing in repair PVC, SWR bends (any radius) of 110mm dia complete all as specified and directed.
Supply and fixing in repair PVC, SWR bends (any radius) of 75mm dia complete all as specified and directed.
Supply and fixing in repair Brass chromium plated tubular towel rail 20mm dia `D' type 60 cm long between flanges, complete all as specified and directed.
Supply and fixing in repair 25 mm dia mild Steel powder coated curtain rods including fixing arrangements, bracekts and finane cap complete all as specified and directed.
M&L for Second class hard-wood in scantlings, clean sawn, timber fixed, incl dismantling scantling 40 Sqcm and above complete all as specified and directed
Taking down carefully unsv/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
Point wiring using FRLS-H PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS-H PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Switch/bell push/fan regulator etc shall be measured and paid separately)
All as per Srl item No. 68 above but for 3 Pin 5 Amp socket outlet point controlled by one switch 5 Amps one way on same board complete all as specified and directed.
All as per Srl item No. 68 above but for 5 Pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per Srl item No. 68 above but for one 15Amp switch socket outlet point concealed using 2.5Sqmm FR-LSH PVC insulated multi-strand copper conductor wire including 1.5Sqmm FR-LSH PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes etc complete all as specified and directed.
Socket outlet, 2 in 1, 3 pin, 6 Amp, flush type, AC 230 volts etc complete all as specified and directed.
Switch socket combination, 5 Amp, 2 in 1, flush type, ISI marked, complete all as specified and directed.
Switch socket combination, 3 pin, 16 amp, ISI marked complete all as specified and directed.
Supply and fixing in repair 1x20 W LED 6000k (4 ft long) decorative ultra slim square prfile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded aluminium body heat shrink, provided for efficient dissipation and itegrated electronic driver complete with lamp complete all as specified and directed.
Supply and fixing in repair 1x10 W LED 6000k (2 ft long) decorative ultra slim square prfile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded aluminium body heat shrink, provided for efficient dissipation and itegrated electronic driver complete with lamp complete all as specified and directed.
Lamp holder(in replacement) insulated body with back plate suitable for batten fitting including LED lamp of capacity 9 watts complete all as specified and directed..
Switch piano flush type, single pole, 6 Amp, one way, AC 230 volts etc complete, all as specified and directed.
Electronic fan regulator, stepped type, hum free socket type suitable to control speed of fan 0-100%, 230 V etc complete all as specified and directed.
Ceiling rose polycarbonate isolated body surface Bakelite, not less than 50x20mm, three terminals, AC 230 volts etc complete all as specified and directed.
Supply and Fixing in repair Street/Security light LED , 60 Watt energy savings and environmental friendly long life versatile pressure die cast aluminium fittings including necessary brackets and clamps complete connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Make : Bajaj/Philips/Crompton/ Wipro Note : CA No shall be written on each fitting before installation.
Supply and Fixing in repair MCB DB TPN 4 way, 415 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
Supply and Fixing in repair MCB single pole neutral (SPN) 240 volts, 40amp, 10KA (C-series) of approved make and cat part etc complete all as specified and directed.
Supply and Fixing in repair MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) of approved make and cat part etc complete all as specified and directed.
Material and labour in repair for sub main wiring with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 4 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 2.5 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed by Engineer in charge. Note : (i) Two run of cable 4 sqmm and one run of 2.5 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking up or laying of cables including getting out in any kind of soil complete all as specified and directed..
Returning, filling in, including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick , complete all as specified and directed..
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed..
Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed.. Note :- For payment purpose punned thickness shall be measured.
Brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
1100 volt grade XLPE insulated heavy duty cable, 25 sqmm 3.5 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable etc complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Material and labour in repair for Earthing complete with galvanised steel earth plate electrode 600mm x 600 mm x 6mm burried directly in ground (earth pit not less that 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanised iron strip 32x6mm by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment / substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granit/Basalt stone aggregate) for earth pit with 40 x 40 x6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed..
M/S BASHIR AND SONS
M/S B A Traders
M/S SHOWKAT AHMAD WANI AND SONS
SOFI CONSTRUCTIONS
M/S B S CONSTRUCTIONS
M/S Gh Qadir
Alishan Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .