Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.9 L+₹64,867 (6.33%)Rejected-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-AOC L2 | |
| 3 | L3₹11.5 L+₹1.2 L (12.0%)Rejected-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-AOC L3 | |
| 4 | L4₹12.6 L+₹2.4 L (23.4%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
30 Jul 2020, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
SPECIAL REPAIRS/ REPLACEMENT OF ALUMINIUM WIRING WITH COPPER WIRING AT SDI (AF) BANGALORE
2020_MES_356850_1
87560CWEAFNMAR
Open Tender
Miscellaneous Works
Item Rate
120 days
GE AF MARATHAHALLI
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF MARATHAHALLI
₹33,000
Yes
11 Aug 2020
29 Jun 2020
1 Aug 2020
29 Jun 2020
30 Jul 2020
18 Jul 2020
30 Jun 2020 - 9 Jul 2020
Amount
Taking down copper/aluminium point wiring (light, fan socket or power)complete fittings such as switches, sockets, ceiling rose, pendents, regulators etc in and including taking down existing all switch board sunken boxes along with laminated sheets and without taking down existing concealed conduit of any type/ size complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any size without taking down existing concealed conduit of any type/ size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC.
Material and Labour for point wiring One light point controlled by one Modular Switch complete 1.5 sqmm FRLS grade single core PVC insulated, unsheathed 1100 V grade copper multistranded conductor drawn through in the existing concealed conduit/ surface conduit as per site requirements with all accessories along with fixing arrangements in walls, roofs floors etc including PVC insulated copper cable FRLS earth continuity conductor 1.5 Sqmm cable connected to common earth dolly in and including supply & fixing factory made modular sunken boxes with modular plates, covers complete concealed in walls for housing modular switches, Sockets and regulators etc as per site requirements complete all as specified and directed for following:- Make:-Plazza/Finole/Anchor/Havells/Polycap/Nicco/RPG. Note for item Ser No 03& 08:- 1. Colour code shall be strictly followed for wiring Red/Yellow/Blue colour for Phase, black colour for neutral and green colour fo earthwire. 2. Copper lugs to be used wherever required in the wiring strictly. 3. Earth wire to be run independently from MCB's to switch boards and also switch board to lght points/Fan points/ socket points etc. 4. The contractor is responsible to repair/ replacement of defective portions of concealed conduits/ surface conduits if any during wiring and also making good surfaces to match with adjoining surfaces all as directed by Engineer-in-charge and the cost shall be inclusive in the quoted rate.
All as per item No 03 above but one ceiling Fan/exhaust fan point controlled by one modular switch.
All as per item No 03 above but One 3 pin 5 Amps socket point on same board with other modular switchs.
All as per item No 03 above but One 3 pin 5 Amps socket point on independent board.
All as per item No. 3 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board complete all as specified and directed. Make:-Plazza/Finole/Anchor/Havells/Polycap/Nicco/RPG.
Material and Labour for point wiring One light point controlled by one Modular Switch complete 1.5 sqmm FRLS grade single core PVC insulated, unsheathed 1100 V grade copper multistranded conductor drawn through in the existing concealed conduit/ surface conduit as per site requirements on walls, surface on roofs and beam etc including PVC insulated copper cable FRLS earth continuity conductor 1.5 Sqmm cable connected to common earth dolly in existing mild steel terminal boxes with new 3mm thick hylem sheet cover fixed with brass screws and cup washers etc for housing the switches, sockets regulators etc complete all as specified and directed. Make:-Plazza/Finole/Anchor/Havells/Polycap/Nicco/RPG.
All as per item No 08 above but One ceiling Fan/exhaust fan point controlled by one switch.
All as per item No 08 above but One 3 pin 5 Amps socket point on same board with other switch
All as per item No 08 above but One 5A 2pin/3pin switch socket out let multipurpose on independent board.
All as per item No. 08 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board complete all as specified and directed. Make:-Plazza/Finole/Anchor/Havells/Polycap/Nicco/RPG.
Material and Labour for switch modular type 6A, one module one way 230 volts complete all as specified and directed . Make:-Crabtree/Legrand/Anchor roma/Havells/HPL.
Material and Labour for modular socket outlet 3 pin, 6 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. Make:-Crabtree/Legrand/Anchor roma/Havells/HPL.
Material and Labour for modular socket outlet multipurpose 2-in-1 3 pin 6/16 Amps controlled by one switch complete all as specified and directed. Make:-Crabtree/Legrand/Anchor roma/Havells/HPL.
Material and Labour for modular switch 16A, one way complete complete all as specified and directed. Make:-Crabtree/Legrand/Anchor roma/Havells/HPL.
Material and Labour for modular fan regulator 120w-2 module complete all as specified & directed. Make:-Bajaj/Legrand/Anchor/Havells/Usha/Khaitan.
Material and Labour for switch piano flush type 5A, SP one way 230 volts complete all as specified and directed . Crabtree/Legrand/Anchor /Havells/HPL/Leader.
Material and Labour for socket outlet 3 pin, 5 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. Crabtree/Legrand/Anchor roma/Havells/HPL/Leader.
Material and Labour for switch socket outlet multipurpose 2-in-1,3 pin 15/5 Amps flush universal type controlled by one switch complete all as specified and directed. Crabtree/Legrand/Anchor roma/Havells/HPL/Leader.
Material and Labour for ceiling rose 3 terminals complete all as specified and directed. Crabtree/Legrand/Anchor roma/Havells/HPL/Leader.
Material and Labour for electronic fan regulator with 5 rotary step socket type suitable for ceiling fan complete all as specified and directed. Make:-Crabtree/Legrand/Anchor Havells/BajajOrient/Crompton.
S & F metal clad switch socket single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps C curve capacityand fixed concealed on walls including making good disturbed surfaces complete all as specified and directed by Engr-in-charge. Make:-L&T/Legrand/ABB/Siemens/Schneider/Havells/HPL.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through in and including PVC conduit of suitable size and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm FRLS single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note: 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre. Make:-Plzza/Finolex/Anchor/Polycap/Nicco/RPG/Havells. Note for Ser No 24 & 25 :- Colour code shall be strictly followed for sub main wiring Red/Yellow/Blue colour for phase, black colour for neutral and green colour for earthwire 2. Copper lugs to be used wherever reuired strictly.
M & L for sub main wiring complete with four runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through in and including PVC conduit of suitable size and accessories in surface of wall, roofs etc with two run of PVC insulated copper conductor 6 Sqmm FRLS single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note: 4 runs of PVC FRLS cable, two run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre. Make:-Plazza/Finolex/Anchor/Polycap/Nicco/RPG/Havells. Note :- 1. All items as applicable for BOQ item No 03 to 25 shall be purchased from original manufactures/ authorized distributor/ dealers as applicable and purchase GST vouchers along with warranty cert of manuracturers duly defaced/ signed by contractor, JE and Engineer-in-charge to be submitted along with payment claims for verification, scrutiny, passing of bill and future record purpose.
G K CONSTRUCTIONS
GKR and CO
SREE VARU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .