| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L1 | Accepted-AOC TENDER FOUND LOWEST AND REASONABLE HENCE ACCEPTED | |
| 2 | L2₹26.7 L+₹1.7 L (6.93%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹28.7 L+₹3.7 L (14.9%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹31.4 L+₹6.4 L (25.5%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹33.9 L+₹8.9 L (35.8%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Feb 2024, 6:00 pmClosed
MASUD ALI, EE, IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
REPAIRS/REPLACEMENT OF INTERNAL ELECTRIFICATION AND ITS CONNECTED WORKS AT DAD,CDA AND THEIR SUBUNITS, HANUMAN TEMPLE AREA UNDER AGE E/M (S) OF GE (S) SCUNDERABAD
2023_MES_631380_2
GE(S)/SEC/TOKEN-55 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SECUNDERABAD
For Enlisted contractors class D and above category b (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
6 documents required · 6 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹70,000
Yes
11 Mar 2024
29 Jan 2024
21 Feb 2024
29 Jan 2024
19 Feb 2024
6 Feb 2024
29 Jan 2024 - 5 Feb 2024
Amount
Taking down existing unserviceable point wiring of any type/ size of light/fan/power/two way/bell etc on TW batten/conduit and removal of unserviceable material out of site area complete all as specified and as directed.
Taking down existing unserviceable light fittings,security light fittings,bulk head fittings,fall ceiling light fittings etc. from any height of building complete all as specified and as directed .
Taking down existing unserviceable MCB's/MCCB's/Distribution boards any capacity complete all as specified and as directed .
Material and Labour for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches, sockets, fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch. Note :- (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (2) The cost of cutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor.
All as per Sl item No 3 above but for One ceiling fan/exhaust fan point controlled by one switch through regulator complete all as specified and as directed .
All as per Sl item No 3 above, but for One 5 Amps socket outlet point on the independent board complete all as specified and as directed .
All as per Sl item No 3 above, but for One 5 Amps socket outlet point on the same board complete all as specified and as directed .
All as per Sl item No. 3 here in before, but for One Bell point controlled by one, bell push complete all as specified and as directed .
All as per Sl item No 3 above but for One light point controlled by two way switch complete all as specified and as directed .
Material and Labour for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new PVC casing caping, ISI marked, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches, sockets, fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch. Note: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth.
All as per Sl item No.10 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No.10 here in before, but for One 3 pin 5 Amps switch socket outlet same board complete all as specified and as directed .
All as per Sl item No.10 here in before, but for One Bell point controlled by one, bell push complete all as specified and as directed .
All as per Sl item No.10 here in before, but for One light point controlled by two 2 - w a y s w i t c h 5 amps, SP complete all as specified and as directed .
All as per Sl item No .10 Above but point wiring of 2.5 Sqmm complete all as specified and as directed .
Material and Labour for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for concealed wiring mount on wall or fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness including back plate and cover plate for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point/fan point controlled by one switch. Note: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth
All as per Sl item No. 16 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed .
All as per Sl item No. 16 here in before, but for One Bell point controlled by one, one way switch 5 amps, SP complete all as specified and as directed .
All as per Sl item No. 16 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No. 16 here in before, but for One light point controlled by two 2 - w a y s w i t c h 5 amps, SP complete all as specified and as directed .
Supply and fix switch piano single pole flush type 5 amps, 230 volts. complete all as specified and as directed
Supply and fix switch piano single pole flush type 15 amps, 230 volts.complete all as specified and as directed
Supply and fix Switch piano two way flush type 5 Amps capacity 230 volts complete all as specified and as directed
Supply and fix Socket flush type multipurpose 2 in 1, 3 Pin, 5 amps, 230 volts complete all as specified and as directed
Supply and fix Socket flush type multipurpose 2 in 1, 3/6 Pin, 5/15 amps, 230 volts complete all as specified and as directed
Supply and fix Switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and as directed.
Supply and fix Switch socket combination 5 in 1 multipurpose 3/5 pin 5/15 amps flush typewith complete all as specified and as directed.
Supply and fix bell push 5 A flush type complete all as specified and as directed
Supply and fix single pole Modular switch 1 way 6 Amps, 1 Module complete all as specified and as directed
Supply and fix single pole Modular switch 1 way 16 Amps, 1 Module complete all as specified and as directed
Supply and fix Modular switch 2 way 6 Amps, 1 Module complete all as specified and as directed
Supply and fix Socket modular type multipurpose 2/3 Pin, 6 amps, 230 volts 2 Module complete all as specified and as directed
Supply and fix Socket modular type multipurpose 3/6 Pin, 6/16 amps, 230 volts 2 Module complete all as specified and as directed.
Supply and fix Modular Bell Push 6A, 1 Module complete all as specified and as directed
Supply and fix in replacement of modular white cover flush box 2 module complete all as specified and as directed
Supply and fix in replacement of modular white cover plate 3 module complete all as specified and as directed
Supply and fix in replacement of modular white cover plates box 4 module complete all as specified and as directed
Supply and fix in replacement of modular white cover plate 6 module complete all as specified and as directed
Supply and fix in replacement of modular white cover plate 8 module complete all as specified and as directed
Supply and fix in replacement of modular metal flush box 1/2 module complete all as specified and as directed
Supply and fix in replacement of modular metal flush box 3 module complete all as specified and as directed
Supply and fix in replacement of modular metal flush box 4 module complete all as specified and as directed
Supply and fix in replacement of modular metal flush box 6 module complete all as specified and as directed
Supply and fix in replacement of modular metal flush box 8 module complete all as specified and as directed Note for item No. 35 to 43: Rate for Cutting the wall ,PCC work & making good the surface is deemed to be included in the quoted rate, complete all as specified and as directed.
Supply and replace PVC rectangular box (Gang box) with 5 Amps switch socket complete all as specified and as directed
Supply and replace PVC rectangular box (Gang box) with 5/15 Amps switch socket complete all as specified and as directed
Supply and replace Plug top 5 Amps 3 pin 250 Volts complete all as specified and as directed
Supply and fix Modular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified and as directed
Supply and fix Electronic type fan regulator stepped switch/socket type, suitable to work on 230 volts complete all as specified and as directed
Supply and fix bell (buzzer/ding dong) working on 230 volts AC Supply complete all as specified and as directed.
Supply and fix ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed
Supply and replace PVC Dummy sheets circular type of 4" complete all as specified and as directed
Supply and replace PVC Dummy sheets circular type of 6" complete all as specified and as directed
Supply and fix lamp holder suitable for B-22 base lamps insulated body surface bakelite with back plate suitable for angle / batten fittings complete including LED Bulb 12 watts, B-22 base complete all as specified and as directed
Supply and fix in replacement LED Bulb 12 Watt suitable for B22 base holder complete all as specified and as directed.
Supply and fix In replacement of old unserviceable light fittings LED tube light fitting Integral 9/10watts LED Tube light fitting internally prewired and incl connecting up with two core wire od suitable size complete as per. Make as per Havells Cat No.-LUMILINEBS9WLED865SPCWH, Wipro Cat No- D571065, Crompton Cat No. LCTLN-10-CDL complete all as specified and as directed .
Supply and fix In replacement of old unserviceable light fittings LED tube light fitting 1x20 Watt industrial batten patti type with bipin holders connector block complete with all accessories internally prewired and incl connecting up two core wire incl 01 no. 20 watt retrofit LED tube rod T8 polycabonate to be fixed at any height of wall/ceiling complete as per. Make : Havells Cat No.-LUMILINEBS20WLED865SPCWH, Wipro Cat No- D562065, Crompton Cat No. LCTLN-20-CDL complete all as specified and as directed .
Supply and fix In replacement of old unserviceable light fittings with new LED tube light fitting box type including 20watts LED Tube rod, polycarbonate, prewired and incl connecting up with two core wire of suitable size complete as per, Make as per Crompton Cat No-IGP161LT8-16 and LT8-20-865-(2), Bajaj Cat No. BLRB-DB 118 and BLRB 20 CW LED., Havells Cat No-REGALBATTENT8UPTO1X22W SSBSWH and PHOTONULTRAE2.01213 T8SSTL20W LED865SPC complete all as specified and as directed .
Supply and fix in replacement Retrofit T8 tube Polycarbonate 4 feet 20 W LED Rod , 240 volt complete as per, Make : Havells Cat No.PHOTONULTRAE2.01213T8SSTL20W LED865SPC, Crompton Cat No.LTT8-20, Bajaj Cat No. BLRB 20 CW LED complete all as specified and as directed .
Supply and fix In replacement of old unserviceable bulk head light fittings with new LED bulk head ip 65 with prismatic diffuser 1x10 Watt white complete with all accessories internally prewired and incl connecting up three core single wire complete as per. Make : Bajaj cat part No. BIBWP 10W LED, Crompto Cat No-LBHP-10-CDL, Havells Cat No-EXAFT10WLED857SSYMBOPC all as specified and as directed .
Supply and fix In replacement of old unserviceable Building security light fitting versatile pressure die-cast aluminium with high power LED 25 W as light source complete with LED 25 W 5000K including brackets made out of GI pipe 25 mm dia light grade pipe bent to shape incl 02 Nos MS flate clamps incl nut bolts connection complete as per Make : Bajaj cat part No. ENXT P 24L WH CR PC SD, Crompto Cat No-LSTS-25-CDL-M, Havells Cat No-ENDURASUNDOWNSL25WLED 765PASYBOPCIHD all as specified and as directed .
Supply and fix in replacement LED bed side lamp 6 watt fixed on existing wall including making electrical connection, complete as per Syska cat No. SSK-TRS-6W or any equivalent model in C&S/Philips/Wipro./Havells complete all as specified and as directed .
Supply and fix in replacement of old unserviceable recess mounting round light fitting of capacity 15 Watts powder coated white CRCA full glow suitable for ceiling including making electrical connection from ceiling rose to light fitting complete as per Crompton Cat No- LSCRM-15W-CDL, Syska Cat No-SSK-TPL-15W, Havells Cat No-EDGEPRONEORDDLR15WLED865S all as specified and as directed .
Supply and fix in replacement of old unserviceable recesss mounting light fitting 1' x 1' of capacity 18 Watts powder coated white CRCA full glow suitable for 300 300 mm POP false ceiling including making electrical connection from ceiling rose to light fitting complete as per Crompton Cat No- LCTLRNE-18-CDL(1X1), Syska Cat No-SSK-PPL-22W, Havells Cat No-BOCR1X1R18W LED857SPCMS complete all as specified and as directed .
Supply and fix in replacement of old unserviceable surface mounting light fitting 1' x 1' of capacity 18 Watts powder coated white CRCA full glow suitable for ceiling including making electrical connection from ceiling rose to light fitting complete as per Crompton Cat No- LCTLSNE-18-FO-CDL, Syska Cat No-SSK-PSP-22W, Havells Cat No-BOCR1X1R18WLED857SPCSS all as specified and as directed .
Supply and fix in replacement of old unserviceable recesss mounting light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for 600 x600 mm POP false ceiling including making electrical connection from ceiling rose to light fittinf complete as per Crompton Cat No- LCTLRNE-36-FO-CDL, Havells Cat No. PLANO2X2PLR36WLED865S, Bajaj Cat No-BCTBLR 36W LED FP CW all as specified and as directed .
Supply and fix in replacement of old unserviceable surface mounting light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for ceiling including making electrical connection from ceiling rose to light fitting complete as per Crompton Cat No- LCTLSNE-36-FO-CDL, Havells Cat Np. PLUTONEO2X2PLR34WLED857S, Bajaj Cat No-BZSSQL 36W LEDWH i all as specified and as directed .
Supply and fix in replacement of old unserviceable LED Flood light fitting 50 watt capacity with SMD LED pressure die-cast aluminium housing with reflactor including making electrical connection from ceiling rose to light fitting complete all as specified and as directed as per Crompton Cat No-CFS-504-50-57-60D-SL-GL-NSG, Eveready Cat No-LEDFL05015-04, Wipro Cat No-D915065. Note :- The Quoted rate is deemed to be included for installation of light fitting at any height including necessary T & P and safety equipments.
Supply and fix LED PLL of capacity 18 watts, 4 pin in replacement of existing 2'x2' CFL light fitting from false ceiling at any height including making necessary electric connection in existing CFL lighting complete all as specified and as directed as per Surya Cat No. SLE 18W PLL. or equivalent in Syska/Bajaj/Havells/Philips
Supply and replace Electronic Driver for downlight of capacity 15/18 Watt as per site requirement complete all as specified and as directed.
Supply and replace Electronic Driver for LED Light of 2X2 fitting of any capacity 36/42 Watt as per site requirement complete all as specified and as directed.
Material and Labour for removing repairing any kind of LED building security light of any wattage by replacing the defective parts,complete replacement of all LED chips,correction of LED PCB circuits in any means including soldering to make it functional and refixing it complete all as specified and as directed
Supply and fix MCB SP 6 to 32 Amps 240 volts C- type complete all as specified and as directed
Supply and fix MCB SPN 40 to 63 Amps 240 volts C- type complete all as specified and as directed
Supply and fix MCB TPN, 415 volts suitable for fixing in MCB DB of capacity 63 Amps,10 KA complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure MCB DB SPN 4 way with 100 amps rated bus bar 240 volts double door with locking system complete all as specified and as directed. Make :- Havells, Legrand, ABB
All as per Sl item No 76 here in before, but SPN 8 way DB complete all as specified and as directed.
All as per Sl item No 76, here in before but SPN 12 way DB complete all as specified and as directed.
Supply and fix in replacement of TPN DB 4 way double door made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed. Make :- Havells, Legrand, ABB
Supply and fix Vertical loadline type TPN DB 4 way double door with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed. Make :- Havells, Legrand, ABB
Supply and fix Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and as directed. Make :- Havells, Legrand, ABB
Supply and fix MCCBs 415V, 25KA, 100 amps 4 Pole suitable for DB complete all as specified and as directed. Make :- Havells, Legrand, ABB
All as per Sl item No 82 here in before, but 63 Amps, 10 KA complete all as specified and as directed
Material and Labour Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
All as per Item Sl No-84 above but using 3 runs of single core 6 sqmm complete all as specified and as directed .
All as per Item Sl No-84 above but using 5 runs of single core 6 sqmm complete all as specified and as directed .
All as per Item Sl No-84 above but using 5 runs of single core 10 sqmm using 32 mm dia PVC conduit complete all as specified and as directed .
Material and Labour Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including PVC Casing & Caping and its accessories including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
All as per Item Sl No-88 above but using 3 runs of single core 6 sqmm complete all as specified and as directed .
All as per Item Sl No-88 above but using 5 runs of single core 6 sqmm complete all as specified and as directed .
All as per Item Sl No-88 above but using 5 runs of single core 10 sqmm using 32 mm dia PVC casing caping. Note for item No 84 to item No.90 :- (1) The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth (2) The cost of cutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(for item 84 to 87) (3) The corresponding runs of copper wire and one run of suitable size of PVC conduit / casing caping shall be measured as one running meter.
Supply and fix Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections , one twin core cable flat or circular multi stranded Aluminium conductor of size 6 Sqmm complete all as specified and as directed
Supply and fix twin core flexible twisted copper conductor wire 1.1 KV for Phase(Red) and neutral(Black) of size 0.5Sqmm for connecting light/switch /socket etc. as per site requirement including taking down old unserviceable one complete all as specified and as directed
Taking down carefully geysers from site of any make and capacity, transporting to MES complaint cell for dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of tank thoroughly with washing compound or liquid solution, applying one coat of milky white synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint and re-fixing of geysers at its original position complete all as specified and directed. Note : (a) Spare part shall be measured and paid separately under respective item of this schedule, however minor items which are not catered in this schedule, the cost of the same shall be deemed to be included in the unit rate of these items. (b) Repair works will be carried out at workshop E&M complaint cell. (c) Repair of geyser shall be completed and re-fixed the same with in 72 Hrs after receipt of complaint slip. (d) The cost of transportation to workshop and back is deemed to be included in the quoted rate of this item.
Material and Labour for repairs to copper inner tank, like denting, soldering, brazing, leak testing and reassembling of any Ltrs capacity water heater (Geyser) complete all as specified and as directed
Supply and replace Geyser element 2000 watts /1500watts of any type (Circular OR tringular) or as per site requirement all as directed.
Supply and replace Thermostat suitable for existing geyser of any make complete all as specified and as directed
Supply and replace Indicator bulb 230 V suitable for any make and colour complete all as specified and as directed.
Supply and replace PVC Cold/Hot water connection pipe 45 cms long 15 mm dia complete all as specified and as directed
Supply and fix Bib taps chromium plated with crutch or butter fly handle 15 mm dia screwed for iron pipe or for brass ferrule and fixed including cutting of GI pipeall complete all as specified and as directed
Supply & fixing Brass Head Assembly having 8 to 9 holes suitable for 25 litres capacity geyser of make – Bajaj, Venus, Recold complete all as specified and directed.
Supply and fixing in replacement inner tank, ISI marked made of stainless steel suitable for 25 Litters capacity geyser complete all as specified and directed.
Supply and fixing PVC insulated round copper wire 3 core 2.5 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire complete all as specified and as directed
Supply and fix Plug Top 3 pin 15 Amps for storage geyser including removal of existing plug top complete all as specified and directed. Make- Anchor, Havells, cona.
Supply and fix Industrial type Plug top 3 pin, 20 Amps suitable for industrial socket for storage geyser including taking down old UNSV / rusted complete all as specified and as directed of Make :- Havells, Legrand, ABB
Disconnection and taking down unserviceable ceiling fan of 1200mm/1400mm sweep from any height of the building and transporting to the work shop,opening the body and rewinding of burnt ceiling fan of 1200 / 1400mm sweep motor with supper enameled copper wire of suitable size including spray repainting it white , fixing of new sealed bearing,capacitor,rubber bushes,canopy,fan clamps and shaft of any make, type, model incl testing after refixing it back at the site complete all as specified and as directed .
Disconnection and taking down unserviceable Exhaust fan upto sweep from any height of the building and transporting to the work shop,opening the body and rewinding of burnt Exhaust fan upto 450mm sweep motor with supper enameled copper wire of suitable size including spray repainting as per site requirement,fixing of new capacitor, sealed bearing ,rubber bushesof any make, type, model incl testing after refixing it back at the site complete all as specified and as directed.
Supply and fix in replacement of ceiling fan downrod of required height including drilling of holes and threads of dia 15 mm as per the site requirement as directed at site complete all as specified and as directed
Supply and replace Fan condenser 2.5 mfd complete all as specified and as directed.
Supply and replace fan condenser of 4.00 Mfd complete all as specified and as directed.
Supply and replace split pins/lock pins for ceiling fans complete all as specified and as directed.
Supply and replace MS Clamp with rubber bushes, bolts & nuts for ceiling fan along with lock pin complete all as specified and as directed.
Supply and replace Canopy as approved suitable for Ceiling Fan of any sweep and make complete all as specified and as directed.
Material and Labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., making good and matching with the existing colour, cutting not exc 10 cm girth complete all as specified and as directed
Supply and fix in replacement of flush galvanised iron sunken box, not less than 1.6 mm thick of size 8" x 10"x 2" (inch) with 3 mm thick bakelite / hylam sheet top cover of white colour ISI marked including machine screw & washer with complete electric connection to existing switch/socket/fan regulators complete with civil work and making good to surrounding surface with white/colour wash or any type OBD as per existing colour of building complete all as specified and as directed
All as per Item No- 115 above but of size 6" x 4"x 2" (inch) complete all as specified and as directed
All as per Item No- 115 above but of size 4" x 4"x 2" (inch) complete all as specified and as directed
Disconnection and removing the existing unserviceable earthing and Material and Labour of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on complete all as specified and as directed. (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).
Material and Labour for replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
Supply and fix/lay GI pipe 15 mm dia med grade for protection of earth continuity conductor complete all as specified and as directed .
vvcenterprises
SUN LIGHT HOUSE
Chandana Enterprises
M Shyam Sunder
Srinivasa Consructions
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .