SAPLESHWAR MANDAL
SUPERINTENDENT ENGINEER
PATNA
SAPLESHWAR MANDAL
SUPERINTENDENT ENGINEER
CONSTRUCTION OF VISITOR COMPLEX AT SUBJAIL SHERGHATI IN THE DISTRICT OF GAYA WITH ELECTRIFICATION
124895
NIT 26/2025-26/GR-04
Open Tender
GENERAL
Patna
• Legal Status of Bidder
• Place of Registration
• Litigation History
• Registration No
• PAN No.
• GSTIN
• Character Certificate (with Letter No. Letter Date, Issuing Office)
• Electrical License Validity upto (in case of sub-contractors affedevit of both the parties)
• NOC for Debar (if required)
GENERAL
PERCENTAGE
L1
1
21 documents required · 21 mandatory
₹5,000
Processing Fee: 590
₹92,810
CE,BPBCC
12 Feb 2026
12 Feb 2026
23 Feb 2026
13 Feb 2026
21 Feb 2026
13 Feb 2026
17 Feb 2026
Cause of Dispute
Owned/Leased / to be procured
Year of Experience (General)
Owned / leased / to be procured
Sub-contractor( Name and Address)
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Per 50 kg. cement
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Stairs,(excluding landings) except spiral-staircaces.
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab up to 0.50 sqm.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing steel glazed doors, windows and ventilatrs of standard rolled steel sections,joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with steel beading of approved shape and section with screw insted of glazing clips and special metal-sash putty of approved make complete including applying a priming coat of approved steel primer: including the cost of metal beading and other fitting except necessary hinges or pivots as required: Steel windows
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying a priming coat of approved steel primer:G.I. Pipes 40 mm nominal bore (class - B)
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size stone aggregate
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4: 20 to 25 mm thick.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps,laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately):Size of Tile 600 x 600 mm.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats) Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: Old steel work (one or more coats)
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete,including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap): 300 mm dia piles.
Extra over item No. 23.3 for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid).: 400 mm dia piles.
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 75mm dia clip
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
DESCRIPTION
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 20 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing brass bib cock of approved quality :15 mm nominal bore
Providing and fixing brass stop cock of approved quality :15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Horizontal
Per Litre
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of allequipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level:All type of soil:300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:150 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 150 mm dia
Per Set
Per Set
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required. (a) Group C
Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4 X 6 sq, mm + 1 X 6 sq. mm earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x10 mm2 + 1x10 mm2)
Supplying and fixing stepped type electronic fan regulatoron th existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following Modular base and cover plate on existing modular metal boxes etc. as required. 12 module Supplying and fixing following size/modules G.I. box along with modular base & cover plate for modular switches in recess etc. as required. 12 modular (200mm X 150mm) Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection bu excluding modular plate etc. as required. 3 pin , 5/6 amps socket outlet Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection but excluding modular plate etc. as required. 5/6 amps switch Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection bu excluding modular plate etc. as required. 16/20 amps, 6 pin socket outlet Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection but excluding modular plate etc. as required. 15/16 amps switch Pilot lamP for indicator, RYB Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supplying and fixing suitable size Gl box with modular plate cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required.
Supplying and fixing 2 Pin, 6 amps ceilling rose on the existing Junction box / wooden block including connection etc. as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Providing and fixing following rating & breaking capacity MCCB in existing cubicle panel board, including drilling holes in cubicle panel, making connections, etc. as required. 25/100 amps, 10 KA
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 100 Amps.
Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required. 63A
Suppling and fixing following way horizontal type three pole and neatrel, sheet steel, M.C.B., distribution board, 415 Volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnection, powder painted including eathing, etc. as required (But without MCB/RECB./ Isolator) 4 way (4+12) single door horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 40 A to 63 A, TP&N
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 2O0 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and laying earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and rifilling etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc.as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required.
Supplying and fixing 70112 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and upto 95 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Supplying and embedding following dia G.t. pipe (medium class) in pole collar/ foundatlon (during casting) for cable entry including bending the pipe to the required shape complete as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
TOTAL Rs P
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Per 50 kg. cement
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Stairs,(excluding landings) except spiral-staircaces.
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab up to 0.50 sqm.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing steel glazed doors, windows and ventilatrs of standard rolled steel sections,joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with steel beading of approved shape and section with screw insted of glazing clips and special metal-sash putty of approved make complete including applying a priming coat of approved steel primer: including the cost of metal beading and other fitting except necessary hinges or pivots as required: Steel windows
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying a priming coat of approved steel primer:G.I. Pipes 40 mm nominal bore (class - B)
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size stone aggregate
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4: 20 to 25 mm thick.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps,laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately):Size of Tile 600 x 600 mm.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats) Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: Old steel work (one or more coats)
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete,including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap): 300 mm dia piles.
Extra over item No. 23.3 for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid).: 400 mm dia piles.
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 75mm dia clip
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
DESCRIPTION
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 20 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing brass bib cock of approved quality :15 mm nominal bore
Providing and fixing brass stop cock of approved quality :15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Horizontal
Per Litre
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of allequipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level:All type of soil:300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:150 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 150 mm dia
Per Set
Per Set
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required. (a) Group C
Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4 X 6 sq, mm + 1 X 6 sq. mm earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x10 mm2 + 1x10 mm2)
Supplying and fixing stepped type electronic fan regulatoron th existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following Modular base and cover plate on existing modular metal boxes etc. as required. 12 module Supplying and fixing following size/modules G.I. box along with modular base & cover plate for modular switches in recess etc. as required. 12 modular (200mm X 150mm) Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection bu excluding modular plate etc. as required. 3 pin , 5/6 amps socket outlet Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection but excluding modular plate etc. as required. 5/6 amps switch Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection bu excluding modular plate etc. as required. 16/20 amps, 6 pin socket outlet Supplying and fixing following modular type switch/socket o the existing modular plate and switch box including connection but excluding modular plate etc. as required. 15/16 amps switch Pilot lamP for indicator, RYB Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supplying and fixing suitable size Gl box with modular plate cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required.
Supplying and fixing 2 Pin, 6 amps ceilling rose on the existing Junction box / wooden block including connection etc. as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Providing and fixing following rating & breaking capacity MCCB in existing cubicle panel board, including drilling holes in cubicle panel, making connections, etc. as required. 25/100 amps, 10 KA
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 100 Amps.
Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required. 63A
Suppling and fixing following way horizontal type three pole and neatrel, sheet steel, M.C.B., distribution board, 415 Volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnection, powder painted including eathing, etc. as required (But without MCB/RECB./ Isolator) 4 way (4+12) single door horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 40 A to 63 A, TP&N
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 2O0 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and laying earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and rifilling etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc.as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required.
Supplying and fixing 70112 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and upto 95 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Supplying and embedding following dia G.t. pipe (medium class) in pole collar/ foundatlon (during casting) for cable entry including bending the pipe to the required shape complete as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
TOTAL Rs P
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
SPECIALCONDITION.doc
NIT • 0.07 MB
e NIT 26 2025-26.pdf
NIT • 0.69 MB
1st Corrigendum e NIT 26 2025-26.pdf
NIT • 0.16 MB
GR-04 TECH 26 2025-26.xls
NIT • 0.04 MB
GR-04 BOQ 26 2025-26.xls
NIT • 0.14 MB
GR-04 BOQ 26 2025-26.xls
NIT • 0.14 MB
Download all tender documents and submit your bid