Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC VALID | |
| 2 | L2₹19.7 L+₹1.6 L (8.60%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹20.0 L
EMD Value
₹40,000
Closing Date
18 Dec 2021, 6:00 pmClosed
GE (AF) SURATGARH
GE (AF) SURATGARH
PROVN OF APPROACH ROAD SOAKAGE WELL ALONGWITH MANHOLES AT ANUPGARH AND CERTAIN MINOR WORKS AT AF STATION SURATGARH
2021_MES_488838_1
8916/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹40,000
Yes
4 Jan 2022
17 Nov 2021
20 Dec 2021
17 Nov 2021
18 Dec 2021
4 Dec 2021
Amount
BOQ (PROVN OF APPROACH ROAD, SOAKAGE WELL ALONGWITH MANHOLES AT ANUPGARH AND CERTAIN MINOR WORKS AT AF STATION SURATGARH)
M&L for Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specifed and directed
M&L for Soling (or sub base) of spread thickness 100 mm with broken boulders or quarried stone, interstices filled, surface formed rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller , complete all as specified and directed.
M&L for 50 mm thick sand filling , spreading , levelling in layers and ramming including watering required complete all as specified and directed.
M & L for Polythene film, black , 50 micron laid in floor including for all laps and narrow width, complete all as specified and directed.
Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars, complete all as specified and directed.
M& L for pavement quality concrete (PQC) in pavement/hardstanding/ramp/slab of flexural strength 40 kg/per square centimeter in field mixed with non circular fibre recron 3 S @ 1 kg per cubic meter & finish surface of concrete road, pavement by brooming and belting, thickness of concrete 25 cm or less including necessary formwork complete all as specified and directed by Engineer in charge.
M & L for forming 12 mm thick expansion joint filled with pre formed bituminous filler and top 30 mm primed and sealed with sealing compound grade B complete all as specified and directed by Engineer -in Charge.(Thickness of pavement=150 mm)
Removing excavated soils exceeding 250M but not exceeding 500M and depositing where directed by Engr-in-Charge.
Excavating over areas not exc 1.50 m deep and getting out in hard dense soil for soakage well complete all as specified and directed.
Excavating over areas exc 1.50 m & not exc 3.00 m deep and getting out in hard dense soil for soakage well complete all as specified and directed.
Excavating over areas exc 3.00 m & not exc 4.50 m deep and getting out in hard dense soil for soakage well complete all as specified and directed.
Excavating over areas exc 4.50 m & not exc 6.00 m deep and getting out in hard dense soil for soakage well complete all as specified and directed.
Excavating trenches not exc 1.5 m wide and not exc 1.5 m depth for soakage well and getting out in soft/ loose soil complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M & L for brick work with sub class 'B' bricks one brick thick honey comb built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class -B bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1.4 ) complete all as specified and directed.
M & L for broken brick aggregate for loose filling, of gauge 80 mm to 150mm graded complete all as specified and directed.
Use and waste of formwork to softits of suspended slab such as roof slabs not exc. 200 mm thick (horizontal / sloping ) complete all as specified and directed.
Use and waste of for formwork for Plinth band including supports, overhangs etc ,complete all as specified and directed.
M&L for Reinforcment cement concrete (design mix) M-25 (20 mm graded aggregates ) as in slabs supported on walls, beams and the like, complete all as specified and directed.
M & L for cement concrete type B1 (1:2:4) 20 mm graded aggregate for Plinth band or mud stops, rounded or chamfered on edges etc complete all as specified and directed.
M&L for Mild steel TMT bars of 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia or seemings with clips complete all as specified and directed.
Returning filling in including spreading, leveling,watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removal of excavated soil to a distance exc 500 m and n exc 1.50 km and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe 150mm dia & rendering,cutting out existing benching channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1,smooth finished & reforming benching as required, complete all as specified and directed.
M& L for Salt- glazed stoneware drain pipes grade ‘A’ 150 mm bore, ISI marked jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed.
M& L for concrete bed to 150 mm dia drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2, complete all as specified and directed.
M&L for 150 mm Bend any radius complete all as specified and directed.
M&L for providing pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded aggregate) as in manhole covers set in cement mortar 1:4, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with integral water proofing compound as per manufacture instruction finished even and smooth without extra cement including necessary scaffolding, complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
S&F framed work of rolled mild steel conforming to Fe-290 (GdeE165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing, complete all as specified and directed.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engr-in-Charge
S&F floor door stopper 150mm overall length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engr-in-Charge
S&F mild steel butt hinges of size 100mm, medium weight, cold rolled, complete all as specified and directed.
S&F 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed.
S&F mild steel barrel tower bolt 200mm long stove enamelled black with bright bolts, complete all as specified and directed.
S&F mild steel pressed steel handles 150mm long oval type, stove enamelled black, complete all as specified and directed.
M&L for two coats of synthetic enamel painting to wood and wood based surfaces of any description, not otherwise described over 10cm width or girth over one coat of pink primer including preparation of new surfaces, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1 : 6 complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement , complete all as specified and directed.
M&L for 01 to 1.5mm thick birla/JK wall care putty to receive smooth finishes complete all as specified and directed.
M&L for painting of treated surfaces to recieve two coats of distemper oil emulsion over alkali resistance primer on surfaces of walls and ceiling complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L PCC type B1 1:2:4 (using 20mm graded aggregate) 25 mm thick as in floor finished surfaces fair and even to receive tile, complete all as specified and as directed by Engr-in-Charge
M&L for PCC 1:3:6 type C2 (using 40 mm grade aggregate) 75 mm thick as in plinth protection / paving finished fair and even without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Demolition of RCC of any description in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition)
M&L for providing reinforced cement concrete Type B-1 1:2:4 (using 20mm graded stone aggt) as in slabs supported on walls, beams and column in floors balconies,canopies, deck slabs and the shelves and the like, complete all as specified and as directed by Engr-in-Charge.
S&F mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking bending and binding with mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and as directed by Engr-in-Charge.
S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - W(Gde-E-250) quality-A, complete all as specified and as directed by Engr-in-Charge.
S&F mild steel for framed structure like trusses, purlins, crane gantries,post rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, Flat sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A, complete all as specified and as directed by Engr-in-Charge.
M&L for designer type gypsum ceiling board / mineral fibre board of size 595 mm x 595 mm x 7-8 mm thick as in ceiling, fixed with screws on GI grid frame work of size 600mm x 600 mm, GI T-section of size 25mm x 25 mm x 1.25mm, GI L-section 25 mm x 25 mm x 1.25 mm, hanging arrangements with roof with GI wire not less than 4.00 mm dia, including applying two coats of distemper oil emulsion (of approve shade) after preparation of surface, complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in post hole (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, thick watering, and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soill, complete all as specified and directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 (Using 20mm graded stone agrregate ) as in foundation of posts, railing and similar work complete all as specified and directed by Engr-in-Charge
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F mild steel flat iron as in wind tie for roof including necessary drilling for securing bolts etc, complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide primer including preparation of new or previously untreated steel/iron surfaces of any description over 10 cm in width or girth, not otherwise described and as directed by Engr-in-Charge.
M&L for providing hardcore of broken stone or boulders of gauage not exceeding 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L providing cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate) , 100mm thick as in sub base in floor/paving etc, complete all as specified and directed.
M&L providing cement concrete 1:2:4 type B2 (Using 40mm graded stone agg) ,100mm thick as in sub base in floor/paving etc including finishing cement concrete surface even and smooth without using extra cement, complete all as specified and directed.
Forming contraction (Dummy) joints 65mm deep x 10mm wide filled with grade 'A' sealing compound all as specified and directed by Engr- in -Charge.
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key scrubbing down with water, complete all as specified and directed by Engr-in-Charge.
M&L for applying two coats of exterior acrylic emulsion (weather proof treatment), in camouflaging patterns , including preparation over new plastered surfaces complete all as specified and directed.
Supplying and laying of 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed..
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed..
M&L for cutting chases for concealed water tubing or pinning end etc and making good the facing /cutting in CM 1 : 3 width exc 10 cm but not exc 20 cm girth in brick walls etc complete all as specified and as directed.
S&F , CP brasss extention nipples of size 25mm to 50mm complete all as specified and as directed.
S&F white viterous china battery based infrared sensor operated urinal of approx size 480x300x740mm having pre & post flushing with water, including fixing to walls complete all as specified & directed. Make : Jaquar Cat No URS-WHT-13255 & SNR-CHR-51097 or Equivalent in GROHE/MARC.
S&F 12mm thick frosted toughened glass as urinal partition of Size 900X450mm fixed with stainless steel brackets & clamps complete all as specified and as directed Make : Jaquar Cat No JSE-CHR-810UC450X or Equivalent in GROHE/MARC.
S&F sensor based hand drier having Stainless steel finish fixed in position complete all as specified & directed. Make : Jaquar Cat No HDR-SAP-M99ACS or Equivalent in GROHE/MARC.
S&F , wall hung WC of size 360X540X405 mm with soft close seat cover complete all as specified & directed. Make : Jaquar Cat No.: FNS-WHT-40951 & FLV-1073C or Equivalent in GROHE/MARC.
S&F , viterous china Counter top wash hand basin of size 700X435X135 mm complete all as specified & directed. Make : Jaquar Cat No.: ARS-WH-39903 or Equivalent in GROHE/MARC.
S&F , CP brass 32 mm dia waste coupling of 130mm height for WHB complete all as specified & directed. Make : Jaquar Cat No.: ALD-WHM-709 or Equivalent in GROHE/MARC.
S&F CP brass 32mm bore bottle trap (with internal partition) with 300mm & 190mm long wall connection pipes & Wall flanges complete all as specified & directed. Make : Jaquar Cat No.: ALD-CHR-769L 300x190mm or Equivalent in GROHE/MARC.
S&F 600mm long braided hose with two 15mm nuts & O-ring rubber washer complete all as specified & directed. Make : Jaquar Cat No.: ALD-CHR-801B or Equivalent in GROHE/MARC.
S&F , CP brass hand shower (health faucet) with 8mm dia 1m long flexible tube & wall hook complete all as specified & directed. Make : Jaquar Cat No.: ALD -579 or Equivalent in GROHE/MARC.
S&F 15mm bore CP brass Bib Cock auto closing system with built in control cock with wall flange complete all as specified & directed. Make : Jaquar Cat No.: CON-047 or Equivalent in GROHE/MARC.
S&F stainless steel toilet paper holder with Flap recessed type complete all as specified & directed. Make : Jaquar Cat No.: CAN-CAN-1153S or Equivalent in GROHE/MARC.
S&F slim concealed cistern with floor mounting frame, installation kit and 'P' type drain pipe connection set for wall hung WC (without flushing plate) complete all as specified & directed. Make : Jaquar Cat No: JCS-WHT-2431FS or Equivalent in GROHE/MARC.
S&F control plate segment chrome plated flushing plate for concealed flushing cistern complete all as specified & directed. Make : Jaquar Cat No.: JCP-CHR-102425 or Equivalent in GROHE/MARC.
S&F soap dispenser with glass bottle complete all as specified & directed. Make : Jaquar Cat No.: SDR-WHT-DJ0010F or Equivalent in GROHE/MARC.
S&F soap dish complete all as specified & directed. Make : Jaquar Cat No.: CAN-BCH-1131N or Equivalent in GROHE/MARC.
S&F single towel RING complete all as specified & directed. Make : Jaquar Cat No.: CAN-CHR-1121N or Equivalent in GROHE/MARC.
S&F 15mm bore sensotronic sensor faucet for Wash basin with 175mm extension body complete all as specified & directed. Make : Jaquar Cat No.:SNR-CHR-51021A or Equivalent in GROHE/MARC.
S&F 15mm bore CP brass Angular stop cock with wall flange complete all as specified & directed. Make : Jaquar Cat No.: CON053KN or Equivalent in GROHE/MARC.
S&F SHOWER WITH ARM complete all as specified & directed. Make : Jaquar Cat No.: 35783KPM & OHS-CHR-1999 or Equivalent in GROHE/MARC.
M&L for 12mm thick Gypsum board as in ceiling/lining fixed with counter sunk screws on & including GI channels frame work of standard section as per manufacturers instruction , fixed @ 1.2m in one direction and 45cm in C/C in other direction with necessary fixing arrangement at their junction point at desired heights below roof slab and including two coats of plastic emulsion paint over a coat of primer on exposed surfaces, the frame work shall be fixed with the help of GI suspenders of suitable size with the help dash fasteners and along wall, making good disturbed surfaces smothening the gypsum board, POP lining at joints panning as required complete all as specified and as directed incl dismantling of existing false ceiling.
S&F powder coated aluminium window/ventilator using 63mm X 38mm X 1.6mm chowkhats with 45mm X 45mm X 1.6mm openable section as in shutter including 5.5mm thick glass panes of approved make with rubber for fixing glass and including builder hardware such as aluminium handles 100mm - 02 Nos, tower bolts 100mm 02 Nos, hooks and eye - 02 Nos 150mm, butt hinges 100mm 04 Nos etc complete all as directed by Engr-in-Charge.
S&F 0.65mm thick sunmica of the approved shade & pattern on the existing woodwork complete all as specified & directed.
S&F 3mm thick teak plyboard with teak face veeners on one face on the existing woodwork complete all as specified & directed.
Taking down eaves gutters, rain water or PVC sewage pipe (any size or pattern) including all fittings including cleaning for re-fixing or removal from site (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed.
S & F , PVC (SWR) floor traps 75mm dia of out let with CP grating including jointing to pipe with solvent cement or adhesive , complete all as specified and directed.
S & F PVC (SWR) pipe single socketed in any length with rubber ring jointing with solvent cement or adhesive laid in trenches or in floor 75mm bore pipe complete all as specified and directed.
S & F PVC (SWR) pipe single socketed in any length with rubber ring jointing with solvent cement or adhesive laid in trenches or in floor 110mm bore pipe complete all as specified and directed.
S & F PVC (SWR) pipe single socketed in any length with rubber ring jointing with solvent cement or adhesive fixed to wall and fixed with mild steel clamps 75mm bore pipe complete all as specified and directed.
S & F PVC (SWR) pipe single socketed in any length with rubber ring jointing with solvent cement or adhesive fixed to wall and fixed with mild steel clamps 110mm bore pipe complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius with oval access door including fixed to pipe with solvent cement or adhesive complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius with oval access door including fixed to pipe with solvent cement or adhesive complete all as specified and directed.
S&F 75 mm bore PVC (SWR) plain bends any radius with oval access door including fixed to pipe with solvent cement or adhesive complete all as specified and directed.
S&F 110 mm bore PVC (SWR) plain bends any radius with oval access door including fixed to pipe with solvent cement or adhesive complete all as specified and directed.
S & F 75 mm bore PVC (SWR) branch pieces single equal or unequal provided with oval access door and jointing to pipe with solvent cement or adhesive as directed
S & F 110 mm bore PVC (SWR) branch pieces single equal or unequal provided with oval access door and jointing to pipe with solvent cement or adhesive as directed
S & F 32 mm bore PVC (SWR) pipe single socketed in any length with rubber ring jointing with solvent cement or adhesive laid in floor or walls or in floor complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for applying 20mm thick plastering in CM 1:4 with the water proofing compound in sunken floors complete all as specified & directed.
Supply only liquid water waterproofing compound complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and as directed.
M & L for Digital printed wall tiles of size 300mm X 450mm x 7mm thick as in vertical surfaces set and jointed in neat cement slurry with spacers and pointed in epoxy tile grout to match the shade over and including 10 mm thick backing coat in cm 1:4 complete all as specified and directed.
M & L for coloured digital printed ceramic non-skid tiles area of tiles exceeding 0.11 sqm but not exceeding 0.18 sqm and 7-8 mm thick laid in floors with spacers, set and jointed in neat cement slurry and pointed in epoxy tile grout to match the shade over and including 15 mm thick screed bed in CM (1 : 6) complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding off/curving the edges of granite stone & polishing complete all as specified & directed
Fixing only ceiling fan 1200 mm sweep with copper winding, double ball bearing in white colour with ISI marking complete including provision of three copper wire of suitable size connected from ceiling rose to fan complete all as specified and directed.
S&F for Sub main wiring (concealed ) with two single core 4 sq mm (nominal area) FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. Note :- 2 run of 4 Sqmm, 1 run of PVC conduit & 1 run of 2.5 Sqmm cable shall be measured as single unit length.
M&L for point wiring with 2.5 sqmm (nominal area) in stove enamelled steel conduit insulated PVC single core unsheathed multistandred copper conductor cable in FRLS and including fittings and accessories with continues stove enamelled steel conduit insulated copper cable with copper conductor of same size as in phase/netural/earth cable connecting to common earth dolly including (enamelleed steel conduit/wooden box of suitable size with laminated sheet cover of 3mm thick mounting swiches, socket,regulator), complete all as specified and directed by Engr-in-Charge.
One light point controlled by on one switch
S&F for flame proof rotary type switch with termination box in LM-6 capacity 16 Amp 240 Volts 50 Hz, complete all as specified and directed by Engr-in-Charge.
S&F for LED light fitting 2x16 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engr-in-Charge.
S&F for MCB SP, 40 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and outgoing elctric connection with suitable size of copper lugs, complete all as specified and directed by Engr-in-Charge.
M&L for ceiling rose, 3 phase/PVC/polycarbonate, isolated body 65x50 mm, complete all as specified and directed by Engr-in-Charge.
Excavating over areas exc 1.5m deep and upto 3m deep getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge.
M&L for rainforced cement concrete beams, cantilevers, bressummers, lintels over 1.5m span in 1:2:4 type B1 (using 20mm graded aggregate), complete all as specified and directed by Engr-in-Charge.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilever, shelves including sup-ports, overhangs etc also splays between floors and beams etc complete flat in rough finished surfaces of concrete, complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore dia PVC (SWR) vent cowl, complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in copings, cills , steps, seismic and other similar bands , plinth courses , string courses and other similar articles , complete all as specified and directed by Engr-in-Charge.
M&L for loose filling with aggregate of broken stone or boulders of gauge 40 to 80mm in soakage pits, soakage wells, complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement , complete all as specified and directed by Engr-in-Charge.
M&L for applying two coats of cement base paint after preparation of newly plastered/concrete surfaces over alkali resistant primer on wall including preparation of surfaces, complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10 mm thick in CM 1:3 on fair faces of brick work or concrete ceiling surfaces, finishing even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
M&L for applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and directed by Engr-in-Charge.
M&L for moorum/ red bajri filling in floors or pavings, laid in layers n. exc 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B2 (using 40 mm grade aggregate) 100 mm thick as in sub base finished even and rough to receive top layer, complete all as specified and directed by Engr-in-Charge.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11 but n.exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
M&L for Glazed colour ceramic tiles in vertical surface 300mm x 200mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
M&L for forming construction joint 30mm deep x 10mm wide filled with grade 'A' sealing compound, complete all as specified and directed by Engr-in-Charge.
S&F PVC solid door frame of size 50mm X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, complete all as specified and directed by Engr-in-Charge.
S&F factory made solid panel PVC door shutter, 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails, MS frames shall be covered with heat moulded plain colour PVC `C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert or top & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed by Engr-in-Charge
S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engr-in-Charge.
S&F extruded aluminium alloy handle of size 100mm, fabricated type, anodised, complete all as specified and directed by Engr-in-Charge.
S&F steel ventilators with top hung shutter including hinges, steel peg stay, complete but without glazing bars, dovetailed or welded, complete all as specified and directed by Engr-in-Charge.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe 290, Gde-E-165, complete all as specified and directed by Engr-in-Charge.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed by Engr-in-Charge.
S&F 15mm bore GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed by Engr-in-Charge.
S&F 20mm GI bore tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed by Engr-in-Charge.
S&F rotational moulded polyethylene water storage tank of 500 litres capacity (Cylindrical vertical with closed top) in position all as specified in SSR Part-I, complete all as specified and directed by Engr-in-Charge.
S&F 20mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed by Engr-in-Charge.
S&F Gun-metal, globe or gate valves 20 mm, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed by Engr-in-Charge.
M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collars, 150mm dia, complete all as specified and directed by Engr-in-Charge.
M&L for providing concrete bed to drain pipe including packing under and hauching against the sides of pipes 150mm dia after they are laid and tested, in cement concrete 1:4:8 type D2 (Using 20mm graded stone aggregate), complete all as specified and directed by Engr-in-Charge.
S&F tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engr-in-Charge.
S&F chromium plated shower roses with or without swivel joints, 125mm dia suitable for 15mm pipe, complete all as specified and directed by Engr-in-Charge.
S&F PVC connection 15mm size, 450mm long with PTMT nuts both side, complete all as specified and directed by Engr-in-Charge.
S&F 15mm Stop valve fancy type, chromium plated with long shank and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union, complete all as specified and directed by Engr-in-Charge.
S&F 15mm Cast copper alloy, Chromium Plated Bib taps fancy type with crutch or butterfly handle, screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engr-in-Charge.
S&F10 ltrs capacity PVC valveless, syphonic action type, flushing cistern with PVC flush pipe 32mm dia, for low level cistern, white, with inlet ball valve, float and handle including brackets, complete all as specified and directed by Engr-in-Charge.
S&F vitreous china wash hand basin white flat back size 630x450mm, waste coupling etc, including cutting for and pinning in ends of brackets or ereting stand, complete all as specified and directed by Engr-in-Charge.
S&F PVC waste pipe 32mm dia 80cm long with socket, complete all as specified and directed by Engr-in-Charge.
S&F white viterous china battery based infrared sensor operated urinal of approx size320X300X525mm having pre and post flushing with water including fixing to walls complete all as specified and directed Make Cera CAT Part no-S4010102 or eqivalent in Grohe/Jaquar/Marc/Kohler.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 16 of tender documents.
M/s JUGAL KISHORE MISHRA AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .