Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC DUDH LINE NAYAGAON VILL SHADIPUR POST SRI VIJAYA PURAM TEHSIL SOUTH ANDAMAN 744106 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744106 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.3 L+₹1.9 L (4.86%)Rejected-AOC C O VM UMMER STEWARTGUNJ BAMBOOFLAT SOUTH ANDAMAN PORT BLAIR 744107 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744107 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹41.5 L+₹2.2 L (5.49%)Rejected-AOC | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹41.8 L+₹2.4 L (6.21%)Rejected-AOC | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹42.0 L+₹2.7 L (6.79%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
27 Mar 2021, 6:00 pmClosed
GE Brichgunj
age contract
SPL REP TO BASKET BALL COURT AT 108 MTN BDE AND CERTAIN BR WORKS SERVICES AT HQ AFC AT CHAKKARGAON, PROVISION OF 5 HP WATER PUMP SET AND FRESH WATER CONNECTION FOR WASH ROOM AT TRAINING AREA BRICHGUNJ MILITARY STATION PORT BLAIR
2021_MES_426129_1
GEBG8106A
Open Tender
Civil Works
Item Rate
180 days
portblair
as per tender documents
9 documents required · 9 mandatory
₹500
BRICHGUNJ
₹62,000
Yes
1 Apr 2021
26 Feb 2021
29 Mar 2021
26 Feb 2021
27 Mar 2021
15 Mar 2021
Amount
Material and labour for applying evenly a priming/tack coat with bituminous primer (VG-30) at 10Kg per 10 Square metre complete all as specified and as directed
Material and labour for Bituminous premix asphaltic dense concrete 40mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and as directed
Material and labour for providing liquid seal coat applying evenly binder at 9.8Kg per 10 Sqm blending with 6.3mm sized stone chipping @ 0.09 cum per 10Sqm and rolled to a uniform smooth surface complete all as specified and as directed by Engg-in-Charge.
Material and labour for 09 (nine) layered ITF classified cushion system of all-weather synthetic acrylic cushion surface, for outdoor type basketball court. The synthetic flooring shall be fungal resistant, anti-microbial & UV resistant all weather type of total thickness minimum 3mm, including laying and spreading of material uniformly without any undulation and without any variation in colour during laying all as per manufacturer's instruction including line marking with two coats of all weather synthetic acrylic paint over a coat of primer as per international standards complete all as specified and directed with following specification:-
(a) 01 (One) layer of priming (for AC surface) (b) 02 (Two) layers of filler course (Resurfacer) (c) 02 (Two) layers of heavy rubber courses. (d) 01 (one) layers of fine rubber courses (e) 01 (one) layer of base coat (f) 01 (one) layer of texture course (g) 01 (one) layer of finish course Note :- The rate quoted is deemed to be including the following:- (i) providing maintenance accessories as per manufactures instructions and shall be handed over to Engg-in-Charge. (ii) Complete removal of unserviceable existing layers of any description in basketball court. (iii) The work shall be carried out by authorised applicator of company only. (iv) Contractor shall provide seven year warranty for synthetic floor work of the court i.e for workmanship and quality of material used. Name of Company: Purple sea sports technology Pvt Ltd/ Costa Sports Systems Pvt Ltd/ Sport master sprot surfaces/Baxter International/ Sunflex sports infrastructure Pvt Ltd/ National sports infrastructure agency.
Supply and erection of basketball poles, made of double channel of size 200x75 mm to box of size 200x150mm with 3.2 meter projection of square pipe on all four corners of the board transparent acrylic back board 1800 x 1050 mm, 30mm thick, frame as per International standards double die frame of aluminum anodised/steel powder coated with built in brackets for mounting and minor adjustments solid steel ring 20mm thick with dia of 459mm at height of 3.05 m from ground hour glass white net of 12 loops 53 cm length back boards and poles shall be of approved/recommended specification of IBF complete all as specified and al directed Note:- The quoted rate deemed to include for the following:- (i) Taking down existing posts with boards - 02 Nos Completely (ii) Earth work PCC foundation as per manufactures instruction RFR and removal etc
Surface dressing not exceeding 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out soft/ loose soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc., and getting out in hard/dense Soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type soil complete all as specified and as directed.
Material and labour for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
Material and labour for treating the bottom & sides of excavation @ the rate of 5 Lit of emulsion per sqm of surface area
Material and labour for ATT on top of earth filling @ 5 lits/sqm
Material & Labour for Moorum/Red Bajri Filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering and complete
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified and directed. Note : Thickness of stone dust will be paid after cushioning after punning.
Demolition of cement Concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
Demolition of PCC Block walling built in cement concrete complete all as specified and as directed
Dismantling for corrugated steel sheeting, any gauge, thickness, Including Removing L-type or J-type bolts in Roof Covering complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets Including frame of any description and any thickness, fixed in any position complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Taking down chowkat with shutter without taking off shutters from the frame exc 1.5 Sqm but n exc 4 sqm complete all as specified and as directed
Taking down chowkat with shutter without taking off shutters from the frame n.exc 1.5 Sqm complete all as specified and as directed
Material and labour for 75mm thick Cement concrete in C1 type (1:3:6) using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement complete all as specified and as directed.
Material and labour for 75mm thick PCC(1:2:4) type B2 using 20mm graded stone aggregate as in flooring finished even and smooth using extra cement complete all as specified and as directed.
Material and labour 100mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sub base of floor complete all as specified.
Material and labour for 75mm thick PCC 1:4:8 type D2 (40mm graded aggregate) as sub base complete all as specified and as directed.
Material and labour for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for Cement concrete 1:3:6 type C-2 (using 40mm grade stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 110mm bore PVC (SWR) drain pipes complete all as specified and as directed.
Material and labour for precast cement concrete solid block masonry with solid blocks using PCC 1:3:6 type C1 using 20mm graded stone aggregate n.exc 10cm in width and setting in cement mortar (1:4) etc complete all as specified and as directed.
Material and labour precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed.
Material and labour for Reinforced cement concrete M30 (design mix) in Beams, cantilevers, bressumers, lintels over 1.5m span, complete all as specified.
Material and labour for Reinforced cement concrete M30 (design mix) in columns, pillars, piers, posts and struts etc complete all as specified.
Material and labour for Reinforced cement concrete M30 (design mix) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified.
Material and labour for Reinforced cement concrete M30 (design mix) in Slab supported on walls, beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the like complete all as specified.
Use and waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 10cm wide and n.exc 20cm wide with rough finished surfaces complete all as specified and as directed..
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) complete all as specified and as directed.
Use and waste form work to sides and soffits of rough finished floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc along splays between floors, and beams, etc complete all as specified and as directed by Engineer in Charge.
Use and waste form work to sides of Pillars, posts, struts, piers, columns and sanctions complete all as specified and as directed by Engineer in Charge.
Use and waste form work to sides of rough finished concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and similar work vertical or to batter complete all as specified and as directed by Engineer in Charge.
Material and labour for TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing clips
All as per item No 42 here in before but 6 mm to 8mm dia.
Material and labour for TMT bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers, and binders in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire.
Material and labour 10mm thick cement plaster in cm (1:3) on top of roof slab complete all as specified and as directed
Material and labour for 15mm thick external rendering in two layers of 5mm thick in CM (1:4) mixed with water proofing compound (water proofing compound shall be @3% weight of cement) over and including a coat of 10mm thick in CM (1:6) over brick or concrete surfaces finished even and fair. Note: Supply only WPC will be measured and paid separately
Material and labour for rendering to ceiling in 5mm thick on fair faces concrete surface in CM (1:3) finished even and smooth without using extra cement.
Material and labour for rendering 10 mm thick in CM 1:6 finished even and smooth without using extra cement etc complete all as specified and as directed.
Supply only water proofing compound Make - Scott No 1 conforming to IS-2645 1975.
Material and labour for oil bound distempering two coats including complete removal of old decorated, plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
Material and labour for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
All as per item No 51 here in before but on ceiling
Material and labour for preparation of new steel surface exc 10cm width or girth and applying one coat of red oxide primer and two coat of synthetic enamel glossy paint.
Material and labour for two coat of weather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer on newly plastered wall surfaces including preparation of surfaces etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for two coat of weather proof exterior acrylic emulsion paint with anti-fungal property over a coat of primer and a coat of external wall putty on newly plastered wall surfaces including preparation of surfaces etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for two coat of weather proof exterior acrylic emulsion paint with anti-fungal property over a coat of primer including complete removal of old decorated, plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
Material and labour for Plates (Plain or Chequered) channels, square or notched (Ordinary and counter sunk) forming holes, without any attachment of Fe 290 (Gde E-165) completely all as specified and as directed by Engineer in Charge.
Supply and fix MS Flat iron wind ties for roof including securing bolts, cutting tops at shape as directed, drilling holes, notching for wire etc and similar work conforming to Fe-290 Gde E-165
Supply and fix steel work in tubular for columns, roof truss, purlins, rafters and battens etc incl special shaped washer etc complete using ERW or induction but welded tube conforming to IS : 1161-1979 Gde St-240 completely providing in any curvature and as of any shape etc complete all as specified and as directed by Engineer in Charge
Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated/semi-corrugated sheet 0.50mm thick as per approved profile, coloured, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self-tapping screws all as specified
Supply and fix Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in ridges to wall, fixed with self-tapping screws as specified
Material and Labour for applying water proofing treatment with the following specifications complete all as specified and as per manufacturer’s instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. Note:- Water proofing compound shall be measured and paid separately)
Material and Labour for taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises and apply water proofing treatment with the following specifications complete all as specified and as per manufacturer’s instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. Note:- Water proofing compound shall be measured and paid separately)
Material and labour for false ceiling with aluminum grid work (Size of grid 600x600 mm) with 35 x 25 x 1.5 mm main tee and 25 x 25 x 1.4 mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600 x 600 x 4 mm thick finished with two coats of oil bound distemper over a coat of primer on exposed surfaces all as specified and directed by Engineer-in-Charge.
Material and labour Glazed ceramic tiles coloured 300x 200x5 to 6mm thick on vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick in CM 1:3 as backing coat for fixing dado tiles all as specified.
Material and labour for coloured glazed ceramic tiles, (450 x 300mm) x 7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match as skirting /dados etc over backing coat 10mm thick in CM 1:3 complete all as specified and directed.
Material and labour Non-skid ceramic tiles each tile area (sqr/rectangle) exc 0.06Sqm but not exceeding 0.11Sqm tile thickness 7 to 8 mm, in floors etc set and joined in neat cement slurry and pointed in white or coloured cement to match incl Screed bed or bedding layer with CM 1:4 15mm thick for laying floor finishes all as specified .
Material and labour for coloured non-skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm n.exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles over and including screed bed or bedding layer of mortar 10mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
Material and labour for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 20mm screed bed CM 1:4.
Material and labour granite 16 to 18 mm thick machine cutting including grinding and polishing and bull-nosing the extruded edging and chamfering and nosing of inner edges incl cutting to accommodate the WHB complete all as specified,
Material and labour for Chequerred cement concrete tiles, with grey cement and pigment 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM (1:4)
Supply and fix Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangement etc, complete with standard aluminium sections, all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply and fix Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Supply and fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
Supply only aluminium fly proof mesh 0.45mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium straps complete all as specified and as directed.
Supply and fix aluminium fly proof mesh 0.45mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium straps complete incl taking down complete all as specified and as directed.
Supply only 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice lamination fixed with aluminium beading as in door panel complete all as specified and as directed.
Supply and fix 4 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed.
Supply only 4.0mm thick Sheet glass ordinary quality and glazing with oil putty in Square exc 0.5sqm in each pane complete all as specified and as directed
Supply only 4.0mm thick Sheet glass ordinary quality and glazing with oil putty in Square n.exc 0.5sqm in each pane complete all as specified and as directed
Supply and fix Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips of sheet cast or extruded sections and fixing bolt or cast aluminium alloy& fixed complete all as specified and as directed.
Supply and fix Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete all as specified and as directed
Supply and fix 150mm long extruded aluminium alloy anodised handles fabricated type, anodised complete all as specified and as directed.
Supply and fix Butt hinges, 100mm length extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21, complete all as specified and directed by Engineer-in-Charge.
Supply and fix Aluminium Die cast Body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and as directed
Supply and fix fancy type 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
Supply and fix in repairs Aluminium anodised chromium plated tubular towel rail, 20mm dia, D type, 60cm long, between flanges including suitable bracket complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs coloured Toilet paper holder, vitreous China, box type fixed to wall with chromium plated brass screws.
Supply and fix in repairs stainless steel, towel rack, 600mm long with 10mm dia four rods and 20mm dia four hooks complete all as specified and as directed
Supply and fix Angular Stop Cock with Wall Flange brass CP 15mm dia bore with cup and washer complete all as specified and as directed. Make: Jaquar cat Part No.CON-059KN or equivalent as approved by GE
Supply and fix in repairs Angle Cock, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as per Jaquar Catalogue No. CON-053 or its equivalent in Marc or Plumber complete all as specified.
Supply and fix 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, minimum weight 142 gms, complete all as specified and directed by Engineer-in-Charge
Supply and fix vitreous China urinal, half stall type complete including waste pipe, flush pipe & providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc, and including connection to flushing pipe and outgoing pipes fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement
Supply and fix in repairs wash hand basin oval type, vitreous china, of size 550x400mm fixed complete incl fixing the same in to granite slab complete including CP waist coupling , waste pipe, PVC Connection of twice on each WHB for Hot & cold all as specified and directed, cost of granite slab will be separately in respective item of sch.
Supply and fix of Bib tap cast copper alloy chromium plated 15mm dia with fancy type screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed by Engineer-in-Charge
Supply and fix of PTMT gratings 125mm dia, complete all as specified and as directed by Engineer-in-Charge
Supply and fix in Repair Stainless Steel Soap Dish Tray. Make - Jaquar Cat NO AQN 7731
Supply and fix in repairs Bib tap cast copper alloy chromium plated 15mm dia with fancy type screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs chromium plated hand shower (health faucet) 1 meter, with PVC tube with wall hook , complete all as specified and as directed by Engineer-in-Charge. (Make : Jaquar cat No ALD-CHR-593)
Supply and fix in repairs glass corner shelf, Cat No.1173 of Jaquar or equivalent, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs PTMT towel rings fixed with and including plated brass screws and wooden/plastic cleats (minimum weight 90 gms) complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs vitreous China urinal, half stall type complete including waste pipe, flush pipe & providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc, and including connection to flushing pipe and outgoing pipes fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs, 10 ltr capacity, PVC flushing cistern, white, syphonic action type, low level, with inlet, ball valve float and handle, PVC flush pipe, brackets etc including taking down unserviceable flushing cistern etc, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs wash hand basin of size 375X475X130mm including all fittings and bracket etc of Jaquar Cat No. JDS-WHT-25907 complete all as specified.
Supply and fix brass CP 15mm dia bore Central hole basin mixer with regular spout without popup waste system with 450mm long braided hoses, 20mm cartridge size also available complete all as specified and as directed . Make: Jaquar cat Part No.FLR-CHR-5167NB or equivalent as approved by GE
Supply and fix in repairs water closet pan (pedestal pattern) white, os size 650X360X800mm of Jaquar Cat. No. OPS-WHT-15751 and with flushing Cistern & fittings of Jaquar Cat.No. ZPS-WHT-15201 complete all as specified
Supply and fix PVC suction hose/ pipe green nominal dia 100 mm, ultra-light and flexible with PVC spiral ribbed for extra strength complete all as directed
Supply and fix Towel rail 600mm long & including Chromium plated brass screws & wooden / plastic cleats (Minimum weight 190gms)
Supply and fix in repairs stainless steel gratings 125mm dia, complete all as specified and as directed
Supply and fix 20 mm bore Gun metal gate valve with iron wheel head ISI Marked, screwed both ends suitable for GI tubing including taking down unserviceable water tubing complete all as specified and directed.
Supply and fix gun metal Valve, globe conforming to IS 9338, 50 mm all as specified and as directed.
Material and labour for CI foot valve conforming to IS:4038, of size 100mm dia with brass strainer complete all as specified and as directed
Cutting chases, pinning in, making good to facings for concealed water tubing and pointing in CM 1:3, cutting not exc 10 cm girth.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store complete of 15mm bore pipe all as specified and directed.
All as per item No 118 above but 20mm bore of pipe.
Taking up or down, 25mm dia bore, GI tubing, medium grade, including cleaning for refixing or removing from site, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 15 mm bore GI tubing medium grade fixed complete to walls and ceiling or laid in floor complete all as specified and directed..
Supply and fix 25 mm bore GI tubing medium grade laid in trenches / floor or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete all as specified and directed
Supply and fix 20 mm bore GI tubing medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, Washing out including taking down unserviceable water tubing complete all as specified and directed.
Material and labour for 15 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed.
Material and labour for 20 mm bore uPVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed.
Material and labour for 25 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed.
Material and Lobour for 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors
Material and Lobour for 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors
Supply and fix repairs PVC connection 15mm size with CP brass Nuts of length 450mm complete all as specified and as directed by Engineer-in-Charge
Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked,IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 25 mm ,including fittings
Supply and Lay GI Steel tubes light grade of ISI Marked as per IS-1239 part-I 2004 with all fittings and fixed complete to wall and ceilings, on pole or laid in floor or in trenches etc. for protection of underground cables complete all as specified and directed for 40 mm outer dia
Supply and fix rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical or vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge
Material and labour for cutting existing 50mm GI line and making branch connection of 40 mm dia GI line complete all as specified and directed
Material and labour PVC (SWR) bends any radius 75mm bore complete all as specified and as directed
Material and labour PVC (SWR) bends any radius 110mm bore complete all as specified and as directed
Material and labour PVC (SWR) vent cowl 110mm bore complete all as specified and as directed
Supply and fix PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
Supply and fix PPR Gate Valves (Brass Insert) of 25 mm bore all as specified and as directed by Engineer -in -Charge.
Material and labour for Providing 15mm thick superior quality chemical pressure treated edged glued finger jointed rubber wood boarding tongued grooved fixed over rubber wood frame work with rubber wood runner of size 50mm x 15mm fixed at 1200mm c/c horizontally by secret nailing with brass screws duly fixed to wall including provision of designed rubber wood beading on top and bottom termination of wood boarding and finished with two coats of melamine polish over a coat of honey/natural colour wood filler putty etc, including preparation and applying sand paper and finishing to a glossy/mat finish complete including dismantling boarding of any description all as specified and as directed. Make : RUBCO or Equivalent
Material and labour for Soakage well of size 1.2m dia and 3m depth with ring foundation in PCC 1:3:6, walls of honeycombed brick bat masonry with top ring of M-25 concrete including RCC cover slab in M-25, Interconnecting pipes of any types complete filled with brick bats including excavation, in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully, copper / aluminium point wiring (light, fan, socket or power ) complete, including fittings and fixtures such as switches, ceiling roses, regulators sockets etc and making good disturbed surfaces of walls floors, etc complete all as specified and directed by Engineer-in-charge.
Material and labour for point wiring complete with proper colour coding using 1100 volt grade 1.5 sqmm, PVC insulated FRLS, unsheathed wire with multi-stranded copper conductor confirming to IS-694 Part-II, ISI marked and including PVC non-metallic, rigid conduit with ISI marked with all accessories concealed in wall/ ceiling/ floor/roof etc, sunk pressed steel not less than 2mm thick, 50mm deep terminal boxes with 3mm thick ISI marked plastic laminated sheet top cover fastened with chromium plated brass screws including 1.5 sq.mm, PVC insulated, FRLS, unsheathed 1100 volts multistrand copper conductor green colour as continuous earth wire connected to common earth dully all as specified and directed for the following:-
(a) One light point / Bell point controlled by one switch
(b) One fan point controlled by one switch and one regulator
(b) One Exhaust fan point controlled by one switch.
(c) One 3 pin switch socket outlet point 5 amps on same board with other switches.
(d) One light point controlled by two way switch
(e) One 3 pin switch socket outlet point 5 amps on independent board.
All as per item No. 142 here in before but with copper conductor cable for 3 pin socket outlet 15 Amp socket outlet on independent board with cable 4 Sqmm size and 4 sqmm earth continuity conductor, complete all as specified and as directed by Engineer-in-Charge.
Material and labour Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: -
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch piano flush type single pole two way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface Bakelite 65 x 50mm 3 terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch socket outlet 3&2 pin (multipin) 5 amps flush / box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch socket outlet 2 in 1, 3/5 pin 15 and 5 amps, controlled by one switch flush / box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz, 100 watts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs bell Ding Dong 240 volts, 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs modular type switches, 6 Amps 240 volts, 50 Hz, complete all as specified and as directed by Engineer-in-Charge. Make : Philips / Legrand /Havells/Anchor
Supply and fix in repairs modular type switches, 16 Amps 240 volts, 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs modular type socket, 6 Amps 2/3 pin 240 volts, 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs modular type socket, 6/16 Amps 3 pin combined 240 volts, 50 Hz, complete all as specified and as directed by Engineer-in-Charge. Make : Philips/ Legrand/ Havells/ Anchor
Supply and fix in repairs modular type fan step regulator, 120W- 1/2 module, 240 volts AC, 50 Hz, complete all as specified and as directed by Engineer-in-Charge. Make : Philips/ Legrand/ Havells/ Anchor
Supply and fix in repairs metal enclosure distribution board SPN 8 way 240 volts with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/C&S/ L&T Note : Incoming & Outgoing connections from the DB shall be provided with proper lugs / thimbles etc.
Supply and fix in repairs MCB distribution board, 4 ways, triple pole and neutral 415 volts vertical mounting, load line distribution board fitted with bus bars, neutral links and blanking plates, double door suitable for TP/FP G frame MCCB, 415 volts, AC including taking down existing unserviceable complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ C&S/ L&T Note : Incoming & Outgoing connections from the DB shall be provided with proper lugs / thimbles etc.
Supply and fix metal enclosure distribution board SPN, 2 way 240 volts, with 100 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, Complete all as as specified and as directed by Engineer-in-Charge Make :Legrand/ C&S/ L&T Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair MCB single pole 240 volts, 0.5 to 32 amps complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ C&S/ L&T.
Supply and fix in repair MCB single pole and neutral, 240 volts, 6 to 32 amps C series complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ C&S/ L&T.
All as per item No. 162 here in above but 40 Amps.
Supply and fix in repairs MCB triple pole 63 amps complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ C&S/ L&T.
Supply and fix in repairs load line MCCB four pole, 415 volts, AC 100 amps with 16 KA breaking capacity at 415 volts and fixed thermal and magnetic setting complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ C&S/ L&T.
Supply and fix in single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP 20 Amps, 240 Volts fixed on flat iron 32x6mm or 2nd class hard wood wooden board complete all as specified and as directed.
Removing of existing DB doors, MCB and MCCB of all capacity including submain / circuit wires and cleaning the vermin/dust and painting the same if necessary, reconnect the wires with thimbles and refixing / dressing the MCBs in DB.
Supply, install & testing exhaust fan plastic body with louvers white 200 mm sweep 1300 RPM complete fixed to wall by making suitable dia for fixing fan with suitable MS bolts, grouted to wall and connecting up including provision of cable from connector to fan with three core flexible cable of size 24/0.2mm with copper conductor from ceiling rose to exhaust fan complete all as directed. Note: Rate deemed to be inclusive of making of hole.
Supply and fix ventilating fan Celso suitable for on working of AC 230 V ,50 Hz 200 mm sweep ,incl louvers complete all as specified Make:Havells HSN code 8414/Crompton/Orient
Supply and fix surface and wall mounted LED batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser &integrated electronic driver 22 W with LED tube all as specified and as directed by Engineer-in- Charge.
Supply and fix energy efficient LED smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core sheathed cable from fitting to ceiling rose including taking down old tube light fittings complete all as specified and as directed. Make: Philips Cat No BN021C LED20S PSU CDL GR or eqvt in make of GE / Wipro.
Supply and fix in repair LED holder type non dimmable bulb 10 watt complete all as specified and as directed by Engineer-in-Charge. Make: Philips / Wipro / C&S / Bajaj.
Supply and fix in repairs 9 watt pin type CFL lamp two pin Non-Retrofit complete all as specified and as directed.
Supply and fix in repair 18 watt pin type CFL lamp four pin Non-Retrofit complete all as specified and as directed.
Supply, fix, install and testing of high speed Monobloc pump set suitable for 415 V, 3 phase , 68 M head ,2.7 LPS including foundation as per manufacturer recommendations and shed for pumpset with suitable rated Starter complete all as specified and as directed by Engineer-in- Charge. Note:- 1. Rate deemed to be inclusive of fittings like tapper/reducer/bends required to connect suction line to pumpset 2. Rate deemed to be inclusive of GI pipe line of suitable dia (length appr. 6m) including connected fittings like tappers/reducer/bends etc required to taken out connection from delivery side of pumpset 3.Rate deemed to be inclusive of foundation and shed.
Supply and lay un-reinforced precast concrete cable cover, class , LV , Type 1 flat size 250 x 150 x 40 mm laid dry in treches over underground cables, embossed with "ELECTRIC" on the top surface complete all as specified and as directed
Supply and lay cable XLPE Insulated screened ,PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 4 core 16 Sqmm 1100 Volts grade with stranded aluminium conductors all as per IS -7098(Part-1 1977) and Part 2- 1985 of following sizes in trench / wall / floor as specified by Eng-In-Charge :-
Supply and fixing ,connecting and testing MCB three pole and neutral (MCB TPN) 440 volts, of capacity 32 Amps, 10 kA in the existing LT panel all as specified and as directed by Engineer-In-Charge :- Note : Rate deemed to be included of any aleration works required to fit the MCB in the panel
Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 140x140x100mm internal comprising of 4 Nos bus bar of capacity 20 Amps one No. earthing terminal including nuts and bolts and connecting up complete MS clamps fabricated from 25x3mm MS flat iron , space & provision for fitting TPN MCB 01 Nos including necessary arrangement for holding sintex box on ground all as specified and directed.
Supply and fix Outdoor type LT sheet metal enclosure for accommodating starter of 5 HP pumpset including necessary arrangement for holding box on ground all as specified and directed.. Note : Rate deemed to be inclusive of any civil works like PCC required at site to hold the box on ground
Material and labour cutting existing 25 mm pipe line and taking connection by inserting Tee 25x25x25 all as specified and as directed
Material and labour for road cutting not exceeding 50 cm width and 50cm depth and making good surface by concreting all as specified and as directed
Material and labour Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead GI strip 32x6 mm and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI medium grade watering pipe, earth test point, commissioning & testing complete. (Note: Main earth lead beyond 7.5 metre measured and paid for separately.)
Material and labour in repairs for sub main wiring complete with two runs of 6sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall / roof / floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories, complete all as specified and as directed by Engineer-in-Charge. Note: (1) Two runs of cable, one run of conduit and one run of earth continuity conductor shall be measured as one running metre.
Material and labour in repairs for sub main wiring complete with two runs of 4sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall / roof / floors etc with one run of 4 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories, complete all as specified and as directed by Engineer-in-Charge. Note: (1) Two runs of cable, one run of conduit and one run of earth continuity conductor shall be measured as one running metre.
Supply and fix 1100 Volt grade heavy duty twin core 10 Sq mm of size,(2 core) flat or circular cable PVC tape and over all PVC sheathed as in service connections suspended by insulated hangers not more than 1.00 meter apart including 4 mm dia GI suspension wire and taking down old unserviceable wire of any type and any size complete all as specified.
M/S AMK CONSTRUCTIONS
SK CONSTRUCTION
Narendran Enterprises
P Babu
NAVJEEVAN ENTERPRISES
T.THIYAGARAJAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .