GE (AF) Mohanbari
GE (AF) Mohanbari
REPAIR AND MAINTENANCE OF INTERNAL WIRING AND ALLIED WORK IN CERTAIN OMQ, SMQs AND SINGLE LIVING ACCOMODATIONS AND TECH BUILDING AT AF STN DINJAN UNDER GE (AF) MOHANBARI.
2020_MES_376053_1
NIT No . 8001/231/01/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AFS Dinjan
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹28,000
Yes
23 Oct 2020
9 Sept 2020
10 Oct 2020
9 Sept 2020
7 Oct 2020
24 Sept 2020
Amount
Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring for light point/ fan/bell point, one light/fan/bell point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FR cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
All as per item No.2 above but One 3 pin 5 Amps socket out let points on independent board
Material and labour wiring for socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FR cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FR cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring for light point/ fan/bell point one light/fan/bell point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FR cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
All as per item No. 5 above but One 3 pin 5 Amps socket out let points on independent board
Material and labour point wiring for one socket outlet on independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated Unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes,3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Supply and fixing socket 3 pin , 5 Amps, 230/240 V complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch socket combination 2 in 1 multipurpose 5 pin , (5/6 Amps ) flush type controlled by one switch complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch socket combination 2 in 1 , 3 pin , (15/16 Amps ) flush type controlled by one switch complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed by Engineer-in-charge.
Supply and fixing ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed by Engineer-in-charge.
Supply and fixing stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing Bell push , flush type , 5 amp complete all as specified and directed by Engineer-in-charge.
Supply and fixing Buzzer, Ding dong, AC 230 Volts, single pole 230 volts complete all as specified and directed by Engineer-in-charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified and directed by Engineer-in-charge.
Taking down existing unservicebale service main / sub main wiring complete all as specified from electric poles to service brackets, wall etc. including removing of unserviceable wiring complete all as specified and directed by Engineer-in-charge.
Supplying and fixing two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed by Engineer-in-charge. Note :- Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item).
Supplying and fixing two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed by Engineer-in-charge. Note :- Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item).
Supplying and fixing two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs recessed mounted 2' x 2 ' LED luminaire 42 watt for Grid ceiling minimumm lumen output 3300 lumen, pre-treated CRCA frame powder coated with high quality diffuser replacable electronic driver and including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 10200 lumen, system wattage 25 Watt, Ingress protection IP-66 with all acessories. complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair GI bracket for street light made out of 40 mm dia GI pipe medium grade 1.5 metre in length bend in shape as required, fixed to pole with two coats of aluminium paint over a coat of red oxide primer including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repair recessed mounted round 12 watts LED downlight (round type) , aesthetically designed aliminium die-cast enclousers, with seperate replaceable constant current driver for grid ceiling minimumm lumen output 1200 lumen,including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixed energy efficiency surface and wall mounted extruded aluminium housing, LED tube light fitting 18 Watts with minimum 110 lumen per watt, including LED tube with polycarbonate diffuser and integrated electroni driver, IP 43 and necessary electrical connection with suitable size PVC insulated copper multi stranded cable, complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs MCB SP, 5 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 5-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixing in repair sheet metal enclosure single pole and neutral with two pin and earth plug and socket complete with one double pole MCB 20 Amps 240 volt complete all as specified and directed by Engineer-in-charge.
Material and labour for checking of ceiling fans upto 1400 mm after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat varnishing including greasing of bearings & other moving parts, replacement of capacitor 2.5 mfd , split pin, jam nut & rubber bush including testing and refixing the same in original position complete all as specified and directed by Engineer-in-charge.
Material and labour for checking of Exhaust fans upto 450 mm after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat varnishing including greasing of moving parts replacement of capacitor 2.5 mfd including testing and refixing the same in original position complete all as specified and directed by Engineer-in-charge.
Material and labour for checking of wall mounted fan any sweep after taking down the fan carefully and removing from site to workshop including rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat varnishing including greasing of moving parts replacement of capacitor 2.5 mfd including testing and refixing the same in original position complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs 0.5 sqmm two core copper conductor flexible unsheathed multistranded for electric connection of fan to ceiling rose including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs plastic ventilation exhaust fan 200 mm sweep including necessary connection complete all as specified and directed by Engineer-in-charge.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 25 x 4 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 8mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion. complete all as specified and directed by Engineer-in-charge. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
FREEZCON
M/S N K SAI TRADING
M/s Sashi Enterprise
S K ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .