Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.6 L+₹2.5 L (9.40%)Rejected-Finance | L2 | Rejected-Finance Not being a lowest tender | |
| 3 | L3₹29.0 L+₹2.8 L (10.7%)Rejected-Finance | L3 | Rejected-Finance Not being a lowest tender | |
| 4 | L4₹29.4 L+₹3.2 L (12.2%)Rejected-Finance SAVITRI COMPLEX JIWAJI CHOWK LASHKAR GWALIOR MP 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | L4 | Rejected-Finance Not being a lowest tender | |
| 5 | L5₹29.8 L+₹3.6 L (13.7%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L5 | Rejected-Finance Not being a lowest tender |
Tender Value
₹25.6 L
EMD Value
₹51,200
Closing Date
20 Oct 2020, 6:00 pmClosed
GE AF TA GWALIOR
GE AF TA GWALIOR
REPAIR/MAINT OF INTERNAL ELECTRIC FITTING AND FIXTURE OF WEST WING OF RUNWAY OF TECH AREA AT AF STN GWALIOR
2020_MES_381864_1
8900/1268/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹51,200
Yes
26 Nov 2020
29 Sept 2020
23 Oct 2020
29 Sept 2020
20 Oct 2020
13 Oct 2020
Amount
Supplying & fixing in repair Stout plus LED is a complete range of industrial LED batten to replace traditional T8 batten.The range is perfact for lighting large areas such as corridor ,warehouses & genral purpose spaces 40watt including all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed. Make :- Havells Cat No STOUTPLUS1200BS40WLED857SPCWH/BAJAJ CAT PART NO BLTRU 20W NW VIVA or equivalent in BAJAJ/CROMPTON/WIPRO as approved by GE.
Supply, fixing, connecting and testing 180 Watts LED highbay luminiare having fin ventilation technology for better thermel management and with cutting edge LED technology seeks to various industrial applications IP66, including clamps, nuts, bolts for fixing arrangement detachable type on wall, trusses with double fixing arrangement etc and connecting the same to electric source with using 2.5 Sqmm (nominal area) stranded copper conductor, three core, PVC insulated & sheathed cable, 1100 volts grade complete all as specified and as directed.Make:: Havells cat part No BAYBRITESAUCERHBP180WLED757WBTOLTG or equivalent in BAJAJ/CROMPTON/WIPRO as approved by GE.
Supply, fixing, installation, commissioning and testing in replacement aviation obstruction lights ( on and over hangers / high rise buildings) comprising of integral LED aviation light comprising of die-cast aluminium alloy housing , with polycarbonate enclosure and including lamp and necessary connection with electric source with copper conductor 23/0.0076 flexible twisted three core cable complete all as specified and directed Make :- Bajaj Cat part No. BGAV 302 LED or equivalent in make specified in Appendix 'B' to PS and approved by GE.
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 150 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- Havells JETAIRISFLS150WLED757PSYMLTG or equivalent in make specified in Appendix 'B' to PS and approved by GE.
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 120 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- JETAIRISFLS120WLED757SYYMLTG or equivalent in make specified in Appendix 'B' to PS and approved by GE.
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 60 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- JJETAQUANTOPLUSFLP60WLED757SYSMLENS or equivalent in make specified in Appendix 'B' to PS and approved by GE.
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed. Make :- ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in make specified in Appendix 'B' to PS and approved by GE.
S&F in repair Ultra bright glass 18W LED tube light with driver and high efficiency suited for installation in exsiting T5 fitting with G5 lamp holders complete all as specified and directed. Make :-Havells Cat part No -TITANISLEEK1149T5DSTL18WLED865SPC or equivalent in make specified in Appendix 'B' to PS and approved by GE.
S&F in repair porcelain lamp holder threaded type suitable for HPMV/ HPSV lamps of any capacity complete all as specified and directed. Make - Bajaj/ CG/ philips
S&F in repair open construction HPMV Ballast copper wound of following capacity suitable for HPMV fittingcomplete all as specified and directed:- (a) 400 watt Make :- Bajaj Cat part no - BJOR 400 MV or equivalent in make as approved by GE.
(b) 250 watt Make :- Bajaj Cat part no - BJOR 250 MV or equivalent in make as approved by GE.
S&F in repair open construction HPSV/MH Ballast copper wound suitable for respective wattage given below for HPSV/MH fitting complete all as specified and directed :- (a) 400 watt Make :- Bajaj Cat part no - BJOS 400 SV/MH or equivalent in make as approved by GE.
(b) 250 watt Make :- Bajaj Cat part no - BJOS 250 SV/MH or equivalent in make as approved by GE.
(c) 150 watt Make :- Bajaj Cat part no - BJOS 150 SV/MH or equivalent in make as approved by GE.
(d) 70 watt Make :- Bajaj Cat part no - BJOS 70 SV/MH or equivalent in make as approved by GE.
S&F in repair Igniter suitable for HPSV/ MH lamp fitting of capacity 70/ 150/ 250/400 watt complete all as specified and directed. Make :- Bajaj Cat part no - BJIGN HPSV / MH-1 or equivalent in make specified in Appendix 'B' to PS and approved by GE.
S&F in repair condenser 20 mfd suitable for HPSV/ MH lamp fitting complete all as specified and directed.
S&F in repair HPMV lamp elliptical shaped outer shell of following capacity suitable for HPMV lamp fitting complete all as specified and directed (a) 400 watt
(b) 250 watt
S&F in repair MH lamp, tubular shaped outer shell of following capacity suitable for MH lamps fittings complete all as specified and directed:- (a) 400 watt
(b) 250 watt
S&F in repair MH lamp, double ended of capacity suitable for MH lamps fittings complete all as specified and directed:- (a) 150 watt
(b) 70 watt
Supply, fixing, connecting & testing of sheet metal enclosures double door (IP 54), DBs of following capacity for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating including disconneting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed. (a) Triple pole and neutral, 4 way Make :-Legrand/Havells/L&T/Schneider
(b) Single pole and neutral, 8 way Make :-Legrand/Havells/L&T/Schneider
(c ) Single pole and neutral, 4 way Make :-Legrand/Havells/L&T/Schneider
Supply and fixing in repair factory made epoxy powder coated distribution board TP & N 4 ways (TPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 125 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed. Make :-Legrand/Havells/L&T/Schneider
Supply and fixing in repair factory made epoxy powder coated distribution board TP & N 8 ways (TPN MCCB DB) with metal door (IP-43protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 63 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed. Make :-Legrand/Havells/L&T/Schneider
Supply & fixing MCCB, 3 pole of following capacity having ultimate breaking capacity Icu = 25 KA, to be fixed in distribution board, complete all as specified and directed. (a) 125 Amps current rating. Make :-Legrand/Havells/L&T/Schneider
(b) MCCB 63 Amps current rating, but breaking capacity Icu = 16 KA Make :-Legrand/Havells/L&T/Schneider
Supply & fixing MCB of following capacity (`C’ series) having current rating 10 KA four pole complete all as specified and directed. (a) TPN, 63 Amps Make :-Legrand/Havells/L&T/Schneider
(b) TPN, 32 Amps Make :-Legrand/Havells/L&T/Schneider
(c) SPN, 32 Amps Make :-Legrand/Havells/L&T/Schneider
(d) Single Pole, 6 to 32 Amps. Make :-Legrand/Havells/L&T/Schneider
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm bore GI pipe light grade for earth lead protection pipe of suitable length and GI pipe 20 mm bore medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its Watering/protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supplying & fixing earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with using 4mm dia GI earth wire complete all as specified and directed
M&L in replacement for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating 1100 Volts drawn in and including surface/ recessed PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:- Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L in replacement for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating 1100 Volts drawn in and including surface/ recessed PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1.5 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:- Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L in replacement for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating 1100 Volts drawn in and including surface/ recessed PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:- Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Supply, laying, testing & commissioning in repair LT cable PVC insulated, PVC inner sheathing, electric power cables (heavy duty) with copper conductor 1100 volt grade of 2.5 Sqmm 2 core size fixed to walls/ steel trusses/drawn in conduit/laid in floor complete all as specified and directed. Make :- Havells /Polycab/ Fort Gloster
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 6 sqmm 2 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed. Make :- Havells /Polycab/Fort Gloster
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 10 sqmm 2 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed. Make :- Havells /Polycab/Fort Gloster
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 16 sqmm 4 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed. Make :- Havells /Polycab/Fort Gloster
Supply and laying XLPE insulated heavy duty armoured electric under ground cable size 25 sqmm 3.5 core, insulated aluminum conductor 1100 volt grade in trench / floors / walls / ducts/on poles or through sleeves etc.including connection & testing and taking out of unserviceable cable complete all as specified and directed. Make :- Havells /Polycab/Fort Gloster Note for Sl No 40 to 44:- Earthwork, Sand cushioning, protection pipe (if any) and PCC cover shall be measured and paid for separately under appropriate item of BOQ/Sch'A'
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) multy stranded copper conductor (FRLS) , single core, PVC insulated & unsheathed cable, 1100 volts grade and using 1.5 Sqmm (nominal area) stranded copper conductor (FRLS) single core PVC insulated & unsheathed cable as in earth wire ( earth wire connected to common earth dolly ) drawn in & including concealed PVC conduit medium grade not less than 20 mm dia with sunken type galvanised iron terminal boxes of 1.6 mm thick and of suitable size duly painted and including top cover 2.80 mm thick ISI marked plastic laminated hylam sheet of required colour for housing/ fixing switches etc complete all as specified and directed. Note- (i) The rate quoted by the tenderer shall deemed to be inclusive of PVC conduit incl fittings ,Terminal/Junction boxes , Hylam sheet , Brass screws and cup washers etc .(ii) The rate quoted by the tenderer shall also deemed to be inclusive of cutting chasses for concealed wiring and making good the disturbed surfaces by using cement mortar in CM 1:4 and including finishing the surface to math with existing surfaces finish . Make of Cable/Wire :- Finolex/HPL/Polycab/Plaza , Make of Rigid PVC Conduit :- Prestoplast/AKG/Plaza/Asian
Supply and fixing switch flush type ,5/6 Amp ,single pole ,one way ,230 Volts AC circuit complete all as specified and directed . Make :- Cona/Havells / Finolex
S&F ceiling rose surface bakelite 65 x 50mm three terminals complete all as specified and directed.
Supply and fixing / laying pipe, GI light grade 40 mm bore fixed on walls or laid under floor with all accessories complete all as specified & directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand filling with clean dry sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge.
UNIVERSAL AGENCY
M/s SIYA ENGINEERING CO
vikas traders
M/s A.K. Trading Co.
M/S Amit Traders
M/s Sagar Construction
m/s vikash Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .