Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 CrAccepted-AOC | ₹8.6 Cr Quoted ₹8.8 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹10.8 Cr+₹2.0 Cr (22.9%)Rejected-Finance | ₹10.8 Cr+₹2.0 Cr (22.9%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹12.9 Cr+₹4.0 Cr (45.9%)Rejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹12.9 Cr+₹4.0 Cr (45.9%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹13.2 Cr+₹4.3 Cr (49.3%)Rejected-Finance | ₹13.2 Cr+₹4.3 Cr (49.3%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹13.9 Cr+₹5.1 Cr (57.4%)Rejected-Finance 2 LETTER OF A W ARD N O N B C C E D CPG 2022 11 05 DATED 04 02 2022 3 LETTER N O N B C C E D CPG 2022 11 06 DATED 04 02 2022 | ₹13.9 Cr+₹5.1 Cr (57.4%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹10.7 Cr
EMD Value
₹8.6 L
Closing Date
27 Feb 2024, 6:00 pmClosed
Chief Engineer Lucknow Zone,
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt PIN -226002
ADDN ALTN CUM SPECIAL REPAIR TO OFFRS JCOS AND ORS MD ACCN AT KANPUR CANTT
2024_MES_638135_1
CELZ/KAN/T-16 OF 2023-24
Open Tender
Civil Works
Item Rate
540 days
Kanpur
As per Tender
8 documents required · 8 mandatory
₹3,000
GE(I) Kanpur
₹8.6 L
Yes
Lucknow
6 May 2024
18 Jan 2024
5 Mar 2024
18 Jan 2024
27 Feb 2024
20 Feb 2024
23 Jan 2024 - 27 Jan 2024
30 Jan 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Description all as per item No 01 here-in-before but reinforced cement concrete any position complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for Brick work with fly ash brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for Brick work with fly ash brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 with complete all as specified and as directed.
M&L for nominal mix type A-0 (1:1.5:3) (using 12.5mm aggregate crushed stone aggregate) as in slabs supported on walls, beams and columns in floors,chajjas, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for form work to soffits of suspended slabs, landings and similar work not exceeding 200mm thick, rough finished surface of concrete complete all as specified and directed.
M&L for form work edges of concrete flats, treads, breaks in floors, window cills, concrete wall, floor and roofs not exceeding 20 cm wide rough finished surface of concrete complete all as specified and directed.
M&L for formwork to side and soffits of floor and roof beam, beam haunching, girders, bressumers, lintels, cantilevers, shelves including supports, overhang,chajjas etc. also splays between floor and roof beam etc. for flat rough finished surface of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length bent to shape required including crancking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 08 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binder and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for 40mm thick PCC 1:2:4 type B-O (using 12.5mm graded crushed stone aggregate) as in floor finishing surface even and smooth with using extra cement complete all as specified and directed.
M & L for glass dividing stripes 3mm thick 38mm width inserted in position and conform to design, complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection surface finished even and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for 25 mm thick PCC type B-0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in leveling /sub base of flooring complete all as specified and directed.
M&L for 7 to 8 mm thick Non skid ceramic coloured tiles (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over & including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 7 to 8 mm thick joint free ceramic coloured tiles (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 7 to 8 mm thick joint free ceramic coloured tiles (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in skirting/dado including jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for joint free glazed ceramic coloured tiles of size 350 X 250 / 450 X 300 mm & 6 to 7 mm thick on vertical surface of walls such as in dado, skirting etc; including and jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles, including 10mm thick rendering in CM(1:4) complete all as specified and directed.
M&L for joint free glazed ceramic coloured tiles of size 1200mmx600mm & 8 to 9 mm thick on vertical surface of walls such as in dado, skirting etc; including and jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles, including 10mm thick rendering in CM(1:4) complete all as specified and directed.
M & L for joint free Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in light shade cement to match with shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
Description all as per srl item No 22 here in before but as in skirting, dados, laid over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for 18 mm thick black granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of stone including rounding and moulding of edge and making hole for cooking gas pipe complete all as specified and as directed.
M & L for Pre Polished Kota Stone in single piece 15 to18 mm thick on risers of steps laid over and including 10 mm thick cement plaster in CM 1:4, fixed and jointed with grey cement slurry mixed with pigment to match complete all as specified and directed.
M & L for Pre Polished Kota Stone in single piece 18-22mm thick on treads of steps and landing laid over and including 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match including rounding, moulding & polishing on exposed edges complete all as specified and directed.
S&F of 15 mm thick approach/parking tiles/stones 1200mm x600mm from which suitable size shall be cut and applied as per site requirements fixed with adhesive as per manufacturer instruction complete all as specified and directed.
Taking down cement plaster on wall and ceiling including raking out joint, hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for complete removal of existing paint, putty and primer coating and exposing the surface till plaster level, complete all as specified and directed.
M&L for 15mm thick rendering of brick wall or concrete surface in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick wall or concrete surface in CM 1:4 finished even & smooth without using extra cement with and including using Water Proofing Compound as per manufacturer instructions complete all as specified and directed.
M&L for 10 mm thick cement plaster on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of OBD over a coat of primer complete all as specified and directed.
M & L preparation of new surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L for Acid/Alkali wash and drying of any existing efflorescence and leaving the wall to dry for min. 3 days to also watch for any extra efflorescence. The surface to be washed with clean water and left to dry for 3 to 4 hours before application of Hydroloc to attain Saturated Surface Dry Condition.
Supplying and applying , one component penetrative-cum-film forming interior waterproofing solution, with negative hydrostatic resistance upto 4 bar, with forced coverage of 350 ml per Sqm single coat using brush or roller, complete all as specified and directed.
Supplying and applying, two components acrylic polymer modified cementitious coating on new masonry surfaces devoid of plaster, with Hydrostatic resistance upto 5 bars with forced coverage of 1.75 Kg per Sqm in two coats using roller or brush with a gap of 4 to 6 hrs between the coats. The coats to be applied shall be perpendicular to each other complete all as specified and directed. Note : The Coverage is to be strictly maintained for film formation.
M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coats oil bound distemper of any colour over a coat of 1mm wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls applying a coat of exterior water based primer with aireless spray techonology with max working pressure of 3300 PSI by Trucare Graco machine and applying two coat of exterior weather proof anit algae, 100% acrylic emulsion with maximum working pressure of 3300 PSI by Trucare Graco machine/Airless paint sprayer (Vands Engineering solutions)/Airless sprayer machine Surya 9 (Jaguar)/Control Pro 190 Air paint sprayer (Wagner) and capable of operational single spray gun with a maximum materials hose length 150m working,complete all as specified and directed.
Complete removal of existing treatment i.e. white wash ,colour wash ,distempering etc. of wall complete , applying a coat of 1mm thick wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc. complete as per manufacturer's instructions and directed at site and applying two coats of oil bound distemper any colour complete all as specified and directed.
Complete removal of existing treatment i.e. white wash, colour wash, cement paint etc. on wall and ceiling complete, with help of hand opeated sander or by manual where it is feasible and preparing the surfaces smooth including necessary repair to depressions/cracks by wall care putty/POP & apply a coat of exterior water based primer with aireless spray techonology with max working pressure of 3300 PSI by Trucare Graco machine/Airless paint sprayer (Vands Engineering solutions)/Airless sprayer machine Surya 9 (Jaguar)/Control Pro 190 Air paint sprayer (Wagner) and applying two coat of exterior weather proof anit algae 100% acrylic emulsion with maximum working pressure of 3300 PSI by Trucare Graco machine and capable of operational single spray gun with a maximum materials hose length 150m working complete all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bound distemper (any colour) on ceiling over a coat of primer complete all as specified and directed.
M/L for Preparation of old decorated surfaces of ceiling, including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spotsetc and applying one coat of white wash on ceiling complete all as specified and as directed.
M/L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spotsetc and applying two coat of white wash on wall complete all as specified and directed.
Taking down existing sunken portion treatment by demolition of old concrete and carry out the sunken treatment as in following steps given below and procedure as per Appendix 'C' of particular specifications :-
S&F of drainage spout GI pipe 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long).
M&L for PCC 1:1.5:3 type A-0 (using 12.5mm graded crushed stone aggregate), 50 mm thick laid in slope towards drainage out spout pipe mixed with waterproofing chemical as per manufacturer instructions of manufacturer. Khurra 150mmx150mm (min) at appropriate location for free flow (of leaked water if any) towards drainage spouts shall be provided integrally while laying PCC. Fixing of spout shall be done with same PCC as in this item.
M&L for 18 mm thick cement platster in CM 1:3 on vertical faces mixed with water proofing chemical of approved manufacturer as per appendix 'D'.
Item no 46.03 shall be executed while concrete is green as per item no 46.03 above and proper curing and ponding test shall be done before laying drainage/water supply pipes upto the entire satisfaction of Engineer in charge.
Applying two coats of SIKA TOP seal 107 of SIKA or other techno commercially of approved manufacturer as per appendix 'D'.
Drainage and water supply pipe if required & test for leakage/sanitary pipes and shall be laid to slope and a clear gap underneath the pipes shall be made available by providing suitable cement concrete blocks.
M&L PCC 1:5:10 type E-2 using 40 mm graded crushed stone aggregate as reqd depth at site over and including 150mm thick 20mm single sized stone agg to provide a filter media.
M&L PCC 25 mm thick 1:2:4 type B-0 using 12.5 mm grade crushed stone aggregate as level course.
M&L for 7 to 8 mm thick non skid ceramic coloured joint less tiles (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed filled with epoxy chemical of approved manufacturer as per appendix 'D'. .mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM ( 1:6 ) complete all as specified and directed.
Note for item :- (i) Waterproofing Treatment shall be undertaken alongwith laying of drainage pipes/Sanitary pipes/ Drainage Spout etc (ii) The work shall be carried out as per the direction of Engineer in Charge. (iii) The sunken treatment work shall only be carried out after written approval of Engineer in charge for Leakage/seepage of water/sanitary pipes. (iv) Cost of drainage spout shall deemed to be included in the item however sanitary pipe, water pipe line if required shall be paid separately under respective item. (v) Laying of Chemical required for varios applications shall be as per manufacturer instructions. (vi) Plan area shall only be measured and paid.
Taking up or down 15 mm dia steel/GI tubing and connection including removal of fittings of any type and material complete and all as specified and directed.
Taking up or down 20 mm dia steel/GI tubing and connection including removal of fittings of any type and material complete and all as specified and directed.
Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring. etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed.
M & L for GI tubing medium grade 15 mm dia galvanised with all fitting laid in trenches or laid under floors, fixed to walls with and including MS clamp etc complete all as specified and directed.
M & L for GI tubing medium grade 20 mm dia galvanised with all fitting laid in trenches or laid under floors, fixed to walls with and including MS clamp etc complete all as specified and directed.
S & F in repair 15mm bore bib tap long body, fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for brass ferule and fixed complete all as specified and directed.
S & F in repair 15mm bore angular stop valve chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F of 15 mm bore, brass CP wall mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and directed.
S&F single liver wall mixer, three in one system, with provision of both hand shower and overhead shower complete with 115mm long bend pipe, connecting legs and wall flench and including maze hand shower 95x95 mm square shape single flow (Face plate stainless steel and ABS body in chrome finish) and overhead shower 200x200 mm square shape single flow (ABS body chrome plated with grey face plate) including all necessary arrangement complete all as specified and directed.
S & F in repair 15mm bore stop valves,fancy type chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 15 mm bore, brass CP WHB mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and directed.
S & F in repair 15mm bore angle valves, fancy type two way chromium plated with long shank and cup screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs for vitreous china wash basin white flat back size 550x400mm but exclusive taps, wastes pipe, chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets or erecting stand, waste pipe, pedestal & brackets complete all as specified and directed.
S&F for in repair 15mm bore PVC connection 600mm long heavy duty with brass fly nut and warsher for hot and cold water complete and all as specified and directed.
S & F in repair brass chromium plated shower rose 125mm size complete all as specified and directed.
S&F in repair 10 ltrs capacity low level PVC dual flushing cistern, valveless, syphonic type, white,with inlet,ball float and handle including brackets and flush pipe complete and all as specified and directed.
S&F in repair Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440 mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan cascade type white with seat cover and flushing cistern dual action type as per manufacturer instructions with all fittings complete all as specified and directed.
S&F in repairs Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specifed.
S&F stainless steel plate rack made out of 1mm thick stainless steel of overall size 750x900mm including fixing with brackets/clamps with screws pattern & design as approved by GE complete all as specified and directed.
Dismantling water tanks capacity exc 250 ltrs and n exc 500 ltrs complete all as specified and directed.
S & F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size complete all as specified and directed.
Dismantling PVC water tanks and remove to store capacity exc 500 Ltrs and n exc 1000 Ltrs complete all as specified and directed.
S & F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size complete all as specified and directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves of 20 mm dia sizes with iron wheel head, screwed both ends for iron pipe or unions and fixed complete all as specified and directed.
S&F in repairs cast iron floor trap of 75 mm dia, chromium plated grating including jointing to waste pipe with lead joints and fixed in cement concrete 1:2:4, type B-0 (using 12.50 mm graded stone aggregate) complete all as specified and directed.
Taking down 75/ 110 mm dia rain water pipes, any pattern with all fittings complete all as specified and directed.
S&F (SWR) PVC Pipe 110 mm pipes double socketed in any length with rubber ring joints fixed to wall/ceiling complete all as specified and directed.
S&F PVC (SWR) bends 110 mm bore complete all as specified and directed.
Dismantling of 75 to 100 mm dia CI pipes including fittings jointed in cement mortar fixed to wall or laid in trenches and taking out if required cpmplete all as specified.
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 100 mm bore laid in floor/trenches all as specified & directed.
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 100 mm bore fixed on walls complete all as specified & directed.
S & F 100mm bore stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F in 100mm dia CI bend (any radius) with oval access door diminshing pieces or tapers (larger bore measured) complete all as specified and directed.
S & F cast iron branch pieces 100mm bore, single (equal or unequal ) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
Description all as item No. 83 above, but double complete all as specified and directed.
S&F CI vent cowl of size 100 mm dia complete all as specified and directed.
S&F CI Sockets (double, collars) 100mm dia complete all specified and directed.
S&F CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 75 mm bore laid in floor/trenches all as specified & directed.
S&F CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 75 mm bore fixed on walls cpmplete all as specified & directed.
S & F 75 mm bore stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F 75mm dia CI bend (any radius) with oval access door diminshing pieces or tapers (larger bore measured) complete all as specified and directed.
S & F cast iron branch pieces 75mm bore, single (equal or unequal ) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
Description all as item No. 91 above, but double complete all as specified and directed.
S&F CI vent cowl of size 75 mm dia complete all as specified and directed.
S&F CI Sockets (double, collars) 75mm dia complete all specified and directed.
Cutting holes through brick walls built, in cement mortar and making good in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required, superficial area exc 400 sqcm but n’exc. 0.10 sqm, complete all as specified and directed.
S&F Soap dish, chromium plated, complete all as specified and directed.
S&F in repair Corner shelf with frame set of three, chromium plated complete all as specified and directed.
S&F in repair, Toilet paper holder, chromium plated complete all as specified and directed.
S&F in repair Towel shelf, chromium plated complete all as specified and directed.
S & F in repair Door type PVC bathroom cabinet with Mirror etc complete all as specified and directed.
S&F in repair Towel rail 20mm dia, 60cm long brass chromium plated with brackets complete all as specified and directed.
S&F health faucet with 15 mm dia 1 mtr long flexible tube and wall hook chromium plated complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking of shutters from the frame) not exc 1.5 sqm complete all as specified and as directed.
Taking down chowkhat or frames with shutter (without taking of shutters from the frame) exc 1.5 sqm n exc 4 sqm each complete all as specified and as directed.
S & F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing complete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S & F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2mm prelam PVC sheet on back face as per specification & drawing, complete as specified and directed.
S&F of 100 mm size Aluminium butt hinges extruded aluminium aloy galvanised mild steel hinge pin, anodised and fixed with, type B21 complete all as specified and directed.
S & F Aluminium 125 mm, anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed.
S & F 125 mm long Extruded aluminium handles, fabricated type., anodised complete all as specified and directed.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of decorative type/wood grain printed colour of size 50 X 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Description all as per item No. 110, above, but size 50 x 125 mm complete all as specified and directed.
Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type/wood grain printed colour flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and including S & F with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
S & F Factory made wire gauged PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded decorative type/wood grain printed colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; wire gauzed i.e. panel will be of wire gauze in lieu of wood grain printed PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly of wood grain printed colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900) used instead of exposed portion of PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed.
S & F 200mm stainless steel fancy handle of approved make fixed with SS screws etc. complete all as specified and directed.
S & F 150mm size extuded aluminium handle fabricated type anodized complete all as specified and directed.
S & F 200 mm stainless steel barral tower bolt of extruded section complete all as specified and directed.
S & F 200 mm aluminium anodised barral tower bolt of extruded section complete all as specified and directed.
S & F 300 mm Stainless steel sliding door bolt with hasp and staple(bolt type) including fixing with necessary accessaries complete all as specified and directed.
S & F 300 mm long aluminum anodized sliding door bolt with hasp and staple and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S & F 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S & F 75mm long aluminum anodised extruded type door stopper of double legged with rubber shoes in bottom complete all as specified and directed.
Cutting in brick walls built, in cement mortar for inserting hold fast and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required, Exc Half brick but not exceeding one brick complete all as specified and directed.
Description all as per item No. 123, above, but wire gauzed window, complete all as specified and directed.
'Description all as per item No. 123, above, but window area exc 1 sqm but not exc 2.00 sqm each, complete all as specified and directed.
Description all as per item No. 125, above, but wire gauzed window, complete all as specified and directed.
S & F framed work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for rigid PVC foam profiles ventilator. Horizotal frame member is made of profile of required size 88x12mm and vertical member strips are made of 71 mmx28mm with MS pipe stiffener (19x19x0.8mm thk) vertical frame member with help of required size CSK screw and adhesive, total unit is fixed with help of bracket/fasteners including 4 mm thick frosted glass and SS Jalli as per requirement complete all as specified and directed.
S & F Powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F in repair Powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long hinge type B-21 100mm long suitable handle complete all as specified and directed.
Description all as per item No. 131, above, but wire gauzed window, complete all as specified and directed.
S&F 5 mm thick glass each panes fixed on aluminium door shutter with and including aluminium beading, rubber gasket etc. complete all as specified and directed.
S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F stainless steel curtain rods of 25mm dia as in doors/ windows pelmets.SS brackets fancy type ,including screws and other necessary fitting(knob) for fixing brackets SS Funnels for 25 mm dia dropry rods, fixed at each end of rods complete all as specified and directed.
Dismantling of boarding, any descripsion, fixed in any position with nails complete all as specified and directed.
S&F of 20 mm thick PVC board made out of 18 mm thick PVC ply and 1 mm thick PVC ply free from rigid one side prelaminated and another side plain colour, PVC sheet stuck on both side with solvent cement adhesive to make the board of 20 mm thick cub board and wardrobe complete all as specified and directed.
M & L 18mm thick coloured MDF board with hardwood fibres prelaminated both sides including cutting, screwing as in kitchen cabinet, almirah shutter including teakwood liping 6mm thick with necessary polishing complete all as specified and directed.
Description all as per srl item no 138 above but in shelf and partition etc. including teak wood lipping 6 mm thick with necessary polishing complete all as specified and directed.
M & L 100mm size stainless steel hinges auto close type complete all as specified and directed.
M & L 125mm size stainless steel handles flush type complete all as specified and directed.
S&F of continuous piano hinges brass bright finish or electro galvanished width of flaps when open in 30 mm complete all as specified and directed.
S&F 40mm width Continuos piano hinges, brass complete all as specified and directed.
S&F 100 mm long hasp and staple, safety type, brass with mild steel hinge pin inculding bolt to hinge plate and fixed and screws complete all as specified and directed.
S&F Ball and catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F 40mm dia, brass polished cupboards knobs fixed with nut, screw and washer of mild steel,bright finished complete all as specified and directed.
S & F SS roller plate with rollers suitable for sliding cubboard drawer complete all as directed.
Dismantling of terracing tiles/brick tiles single layer on roof,laid bedded and pointed in any mortar complete all as specified and directed by the Engineer-in-charge.
Demolition by using hand held electric drills, cutting machine, chisels etc (direct use of hammers on RCC roof for demolition is strcitly prohibited) of roof treatment including padding concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed by the Engineer-in-charge.
M&L for cement concrete type B-0 (1:2:4 ) (using 12.5 mm graded crushed stone aggregate) as in padding and coping,incl hunching, benching etc complete all as specified and directed.
M&L for 10 mm thick in CM(1:3) rendering on fair faces concrete surfaces/roof top mixed with liquid water proofing compound finished even & smooth without using extra cement complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M & L roof kerb of cement concrete 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) mixed with and including SBR ploymer as manufacturer's instructions all around periphery of the wall complete all specified and directed.
M & L preparation of newly plastered sufaces of roof including cleaning the surfaces by using wire brush / pressure hose and applying high performance polyurethene liquid membrane waterproofing coating cold applied in two coats @ 1.5Kg /Sqm/ 2 coats spray/ brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3 N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging abiltity of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet,complete as per manufacturer's instructions complete all as specified and directed. Note: The contractor shall submit a gurantee of 10 years from the date of completion of work for waterproofing treatment alongwith manufacturer's gurantee. The amount of Rs. 40 (Forty ) per Sqm and min of Rs. 4000/- for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against guarantee money. 2. The water proofing shall be carried out by authorised applicator of manufacturer only. The name of applicator shall be got approved from GE before commencement of work.
Removing of demolished material to a distance of exc 100m and n exc 200m or under, beyond the lead included in the rates, including loading, unloading complete all as specified and directed
Dismantiling of concrete by chiselling from RCC members like col, beam, parapet, facia, ceiling etc exposing the reinforcement without disturbing the reinforcement and get free from rust by sand blasting providing at places addl reinforcement welding with existing reiforcement as directed wherever required binding with welded mesh 100 mmx100mm (12 gauge welded mesh) & tack welding and primed with using Araldite epoxy resins ( manufactured by M/s Ciba Geigy Ltd/ FAIR BOND EP/Sika or other approved manufacture) & provision of guniting pressure 2 to 3 Kg/Sqm with admixer 1 cement 3 sand mixed Dr fixit Pidicrete SC plasticiser (2 to 10% by weight of cement) of thickness 40mm average including stripping, floating with wooden strippers for proper dimension control inclusing necessary form work & scaffolding up to Three storey complete and surface of guniting to be finished fair and even with and including 10 mm thick plaster in cement mortar 1:4 with water proffing compound @3% by weight of cement, cleaning & removing of waste material etc as directed at site including necessary painting,white wash, distemper/ exterior acrylic emulsion).All surrounding wall, joineries and fitting should be covered with polythene sheet by contractor while work. (Any wall, floor,fittings and roof damaged by the contractor shall be repaired/change by contractor under same item and no extra payment will be paid to contractoron this account complete all as specified and directed. Note: Welded mesh & addl reinforcement if required measured and paid separetly.
M & L for Mild steel TMT bar 6 mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally, binding wire (0.9mm dia annealed ) complete all as specified and directed.
M&L for Welded steel wire fabric weight n exc 4 Kg/sqm complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete alll as specified and directed.
M & L for preparation of new steel or iron surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat zink chrome red oxide primer complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in Soft / loose soil complete all as specified and directed..
M & L for cement concrete 75mm thick type D-2 (1:4:8) (using 40mm graded crushed stone aggregate) as in Sub-bases, Sub base, floors and pavings etc. complete as specified and directed.
M&L for interlocking precast colored cement concrete glazing finished pavement blocks 60 mm thick M-35 grade with grey cement and pigment con-forming to IS 15658 laid dry hand packed tightly over a lay-er of sand to the true levelled surface concrete tiles pattern shall be as directed complete all a specified & directed. Note:- Supply of sand shall be measured & paid separately under respective item)
M & L for chequered coloured cement concrete tiles 30cmx30cmx25mm thick set and jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed.
M & L for cement concrete type B-0 (1:2:4) (using 12.50 mm graded crushed stone aggregate) as in edging portion of paver block for proper matching with existing surface complete all specified and directed.
Supply only sand filling under floor or in foundation including watering and in consolidation complete all as speified.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets as specified and directed.
Supply & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with DUNE (MICRO LOOK) EDGE TILES WITH XL 15 mm EXPOSED STEEL ANGLE. The tiles should have Humidity Resistance (RH) of 99%, NRC Upto 0.5, Light Reflectance >85%, Thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class 0/Class1 (BS 476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38-41%.The steel angle should be with 15mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32, 27 and 27mm and a load carrying capacity of 7.5 Kgs/Sqm. The T Sections have a Galvanizing of 90 grams per Sqm & passed through 500 hrs of Salt test ,Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centre to centre incl 4mm dia suspension wire MS @ 1200mm C/C complete all as specified and directed according to manufacturers instruction and complete all as specified and as directed.
Dismantling of unframed work timber scantlings 40 sq. cm and over in section, in any position complete all as specified and as directed.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings as complete all as specified and as directed.
S & F of Pre- painted galvalume aluminum zinc coating GI based profile sheet TCT with gsm -150 sheet 0.50mm thick of any colour total mass coating 150gms/sqm (both side) and having tensile strength of 550 Mpa as in roof covering/cladding to wall/window chajja, fixed with self tapping screws complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel TCT with gsm -150 sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F wind ties for roof including securing bolts as directed, including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide n.exc 10cm width or girth complete all as specified and as directed.
S & F in repair salt glazed stoneware gully trap of size 100x100mm complete all as specified and directed.
M/L for preparation of old painted surfaces of wood and wood based materials of any description not other wise described over 10 Cm width or girth and applying one coat of Synthetic Enamel paint (any colour) complete all as specified and as directed.
M/L for preparation of old painted surfaces of iron and steel based materials of any description not other wise described over 10 cm width or girth and applying one coat of Synthetic Enamel paint (any colour) complete all as specified and as directed.
S&F for Stainless steel tray, bucket and baskets of suitable shape and size for modular kitchen, fixing as per manufacturer's instructions complete all as specified and as directed.
M&L for painting two coat of synthetic enamel paint over bricks, stones, concrete or any plastered surfaces of any description over 10cm girth or width, not otherwise described including preparation of new surface complete all as specified and as directed.
S&F stainless steel (304 Grade) single plate of 18 gauge of required shape & size and engraving specific letters or figures any size & nos of computerized graphics duly filled with required colours including buffing, polishing the SS plate, necessary screws, nuts and bolts etc, fixing the plate on wall complete all as specified and as directed.
S&F for 15 mm bore sink mixer chromium plated with swinging casted round shape spout (wall mounted model) with connecting legs and wall flanges. complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY Taking down old copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc.removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls floors etc complete all as specified and directed
M&L for point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost
Description all as per srl item No-186 here in above but upto ceiling height and on surface at ceiling complete all as specified and directed.
Description all as per srl item No-186 here in above but for one 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduitcomplete all as specified and directed.
Description all as per srl item No-186 here in above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
Description all as per srl item No-186 here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
Description all as per srl item No-186 here in above but for one light point controlled by 2 nos two way switches complete all as specified and directed.
S & F switch piano flush type sngle pole 5 Amps one way 240 volts complete all as specified and directed.
S & F switch piano flush type sngle pole 15 Amps one way 240 volts complete all as specified and directed.
S & F bell push flush type sngle pole 5 Amps one way 240 volts complete all as specified and directed.
S&F socket 5 Amp, 5 pin flush type 240 volts complete all as specified and directed.
S&F socket out let 6 pin 5 and 15 Amps multi purpose 2 in 1 flush type 240 volts complete all as specified and directed.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts complete all as specified and directed.
M&L for switch modular type one way 1 module 16 amps 240 volts complete all as specified and directed.
M&L for switch modular type two way 1 module 6 amps 240 volts complete all as specified and directed.
M&L for bell push modular type 1 module one way 6 amps 240 volts complete all as specified and directed.
M&L for socket 6 amps modular type 2/3 pin combined 2 module, 230 volts complete all as specified and directed.
M&L for socket modular type, 2/3 pin, 6 and 16 amps combined 2 module, 230 volts complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete all as specified and directed.
S & F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
Taking down old/Unserviveable concealed/surface copper/aluminium submaun wiring complete all as specified and directed.
M&L for Submain wiring with two single core 4 sqmm cop-per conductor, FRLS-H insulat-ed, multistranded, unsheathed cable ISI marked drawn in con-duit concealed in wall surface / ceiling for sub main connec-tion including one run of 4 sqmm FRLS-H insulated mul-tistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified.(For connection to flood light) Note:- Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
M&L for Submain wiring with four sin-gle core 6 sqmm copper con-ductor, FRLS-H insulated, multistranded, unsheathed ca-ble ISI marked drawn in con-duit concealed in wall surface / ceiling for sub main connec-tion including two run of 6 sqmm FRLS-H insulated mul-tistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified Note:- Four single core 6 sqmm copper conductor, one run PVC conduit and two run of 6 sqmm earth wire shall be considered & measured as one unit.
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20 W) luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification. complete all as specified and directed.
S&F in replacement of LED bulk head fitting with opal diffuser 10 Watt, 6500 K, IP-65, with efficient heat dissipation and integrated electronic driver complete connecting electrically complete all as specified and directed.
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification. complete all as specified and directed.
Supply and fixing in replacement of High power LED wall security light 35 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as specified and directed.
S & F VTPN distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to complete with one MCCB 3 pole 415 Volts 125 Amps, 4 pole rating with rupturing cap 26 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
Supply and fixing sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply and fixing sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
M&L for MCB single pole 240 volts 5 to 32 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts 40 to 63 amps,with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L for single pole and neutral enclousere with a top pin, earth plug and socket complete with one SPN MCB 25 Amps, 240 Volts.complete all as specified and directed.
Supply and fixing electric water heater, stoarge type made of ultra thick super cold rolled steel plates, feroglass dry powder coat-ing technology inner tank and heating element heavy duty mag-nesium anode rod with steel core to protect enamelled tank from rust and corrosion 2 KW Capacity, 230 Volt, 1 Phase AC, 50 Hz, 25 Ltrs, BEE 5 Star, Energy saving high density PUF insulation, glass coated heating performance and resistance to oxidation and carbonation at high tempratures rated complete with all accessories such as safety valve, thermostat, NRV, connection piece and writing MES no. in black synthetic enemael paint/engraving tool etc complete all as specified & directed.
Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified & directed.
Supply and fixing Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 250 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, grouting of nuts, bolts, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side (outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed.
Supply and fixing wall mounting fan 400mm sweep 50 watt,1360 RPM with approved/white colour air delivery 65 m3 /min single phase 220volt 50Hz with contrl pull cord for fan on/off and oscillation on/off complete mounting accessories,b;ade ,guard set,guard ring and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed
Supply and fixing electric chimney wall mount ,noiselevel 58db,auto clean,motion sensor control,operation mode exhaust type ,size of chimney 600x500x140,push button control type,3stage speed setting single phase 220volts,150watt 1200 m3 /hr with energy saving LED lamp with baffle filter with all accessories required to install the electric chimney and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, with remote unit for speed control and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete all as specified. Note :- (a) Make, Model & Colour of fan as approved by GE. (b) Writing MES No. in black synthetic enamel paint by the contractor. (c) T & P will be provided by the contractor for reaching any height of the ceiling.
Disconnecting & taking down any type of geyser, exhaust fan and ceiling fan and deposit to MES Store. complete all as specified and directed.
Disconnecting & taking down any type of Electric Meter and deposit to MES Store. complete all as specified and directed.
Fixing only Electric Meter alongwith connected items after completion of B/R & E/M works complete all as specified and directed.
M&L in replacement of earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTE:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as speci-fied and directed.
Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured and paid.
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.
M&L for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 185 sqmm 3.5 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 150 sqmm 3.5 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed.
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 95 sqmm 3.5 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed.
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 70 sqmm 3.5 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed.
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 50 sqmm 3.5 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed.
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 35 sqmm 3.5 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed.
Supply, laying, testing and commissioning of XLPE PVC insulated of cross sectional area 25 sqmm 4 core, PVC sheathed armoured LT 1100 volts heavy duty with aluminum conductor passing through pipe, in duct, on poles, in trenches including fixing hardware, clamps, making good the damaged surfaces etc, as required complete all as specified and directed.
Supply, installation, testing and commissioning of LT Busbar Chamber, factory made, 3 phase 4 wire, having 250 Amp insulated Aluminium Bus Bar mounted on 1.1 KV rating resin/porcelain insulators, outdoor pedestal type weather and vermin proof fabricated out of 3.15 mm thick mild steel black sheet , sloppy roof, powder coated inside and outside with approved paint over a coat of primer with front door hinged type including locking arrangement , two earth terminals, suitable cable glands for incoming and outgoing cables complete alongwith fixing materials such as bolts 7 nuts and it should be mounted on 40x40x6 mm angle frame with a clearance of at least 0.45 mtrs above GL and grouted in ground 0.30 mtrs including required PCC for foundation coping complete all as specified and directed.
M&L for drilling manually in soft/loose soil under road/hard standing/culvert/nala of suitable bore for protection GI pipe upto 80 mm bore complete all as specified and as directed . Note: Depth of bore shall not be more than 1 Mtr from original ground level complete all as specified and directed.
M&L for 50 mm dia galvanised steel tubing, light grade, with all necessary fittings and fixtures laid in trenches, fixed to walls, poles, under road/floor etc for cable protection complete all as specified and directed.
M&L for 80 mm dia galvanised steel tubing, light grade, with all necessary fittings and fixtures laid in trenches, fixed to walls, poles, under road/floor etc for cable protection complete all as specified and directed.
Supply, installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including disconnecting cable from old unsv LT feeder piller box with mccb, mcb, main switch, busbar and dismantling the same complete with the following items housed in :-
BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).
INCOMING:- (i) 4 pole MCCB of capacity 315 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35 KA with thermal magnetic release type with overload adjustability - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos
OUTGOING:- (a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 04 Nos (b) MCCB 4 pole of capacity 63 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 01 Nos
NOTE:- Rate quoted shall be deemed to be inclusive of replacement of all cable lugs, by removing damaged part of cable and taking out cable from loop to required length including necessary earth work as per site requirement or as directed by Engr-in-charge) Factory inspection at manufacturer premises shall be carried out by the officer detailed by Accepting Officer
Supply,installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board complete with the following items housed in :-
BUSBAR :- 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).
INCOMING:- (i) 4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type with overload adjustability - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos
OUTGOING:- (a) 4 pole MCCB of capacity 200 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos (b) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos
NOTE:- Rate quoted shall be deemed to be inclusive of replacement of all cable lugs, by removing damaged part of cable and taking out cable from loop to required length including necessary earth work as per site requirement or as directed by Engr-in-charge) Factory inspection at manufacturer premises shall be carried out by the officer detailed by Accepting Officer
LUMOS INFRA PVT LTD
RAGHUSONS INFRA ENGINEERING PVT. LTD
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
Varindera Constructions Limited
M/s Matadeen Ramchandra Agarwal
AMIT ASSOCIATES
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_714377.xls
BOQ Document • 3.01 MB
137555974.pdf
Tender Document • 0.40 MB
Tender.pdf
Tender Document • 1.22 MB
137555983.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .