Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.7 L+₹2.5 L (7.97%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | Rejected-Technical 512 227 5TH LANE NISHANTGANJ LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | - | Rejected-Technical Due to DD of GE(West) Lucknow uploaded with another application. | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to not enlisted in appropriate category. | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to not enlisted in appropriate category. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Mar 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPECIAL REPAIR TO BLDG NO P-56 (RENAL TRANSPLANT CENTRE) OF CH (CC) AND PROVN OF 15 X 150 LTRS WATER COOLER IN BLDG NO P-153 TO P-159 OF NO 1 TT WG, AMC C AND C UNDER GE E/M LUCKNOW
2023_MES_579463_1
GE/EM/LKO/HOSP/T-69 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹60,000
Yes
29 Apr 2023
7 Feb 2023
6 Mar 2023
7 Feb 2023
4 Mar 2023
20 Feb 2023
Amount
Demolition of existing roof treatment of any type, complete all as specified and directed.
M&L for high performance hybrid polyurea slastomeric water proofing coating cold applied of spray/brush applied , smartcare ulton liquid membrane at 1.5 Kg/Sqm with an elongation of 600% and tensile strength of 12.6 N/sqmm as per ASTM D2370, crack bridging ability of 3.5 mm as per ASTM C1305, shore a hardness of min 75 as per ASTM D2240. The system includes final base preparation as per site requirement, epoxy primer application and applying smartcare Ultron or approved equivalent in two coats at a coverage of 1 Kg/Sqm etc complete as per manufacturer's specification including cleaning of the surface over and including 15mm thick screed bed in cement mortar 1:4 with water proofing compound @ 3% of cement weight with written guarantee of 7 years from date of completion, complete all as specified and directed. (Note :- Work to be carried out through authorised applicators of the manufactures)
S&F Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 500 litres including taking down old existing tank complete all as specified and directed.
S&F Ball brass valves, high pressure, with polythene float & steel rod & fly nut complete, screwed for iron pipe or brass ferrule and fixed 20 mm bore pipe, complete all as specified and directed.
S & F 20mm dia gun metal or gate valve with iron wheel head screwed both for iron pipe and fixed, complete all as specified and directed.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 10mm thick screed in CM 1:4, complete all as specified and directed.
M&L for Coloured Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for non skid ceramic tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for non skid ceramic tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement mortor 1:4 complete all as specified and directed.
Supply only integral water proofing compound powder conforming to IS specification, complete all as specified and directed.
M&L Anti-Microbial Protection: These product hygiene coatings start the bio cidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years. This Hygiene coating are independently tested by leading universities to demonstrate resistance. Note : (Anti-Microbial Protection: Filling of all Joints and cavities and Sanded Flush to provide a joint less finish and then sprayed with a water based liquid plastic aseptic and self sterilizing wall coating system to a d.f.t. of 300 microns with primer. These hygiene coatings should start the biocidal action as soon as the microorganism land on the surface, and prevent the growth of mould, bacteria and yeasts for at least 5 years. including removal of any types of existing treatment on wall/ceiling and preparation of surfaces as required, complete all as specified and directed. (Note:- The work will be carried out in very restricted permissible condition, quoted rates deemed to included for wastages of labour and material components accordingly)
M&L for brick work with fly ash bricks as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L for 10 mm thick rendering in CM 1:4 on fair faces of brick work surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 10 mm thick rendering in CM 1:3 on fair faces of brick work surface finished even and smooth without using extra cement in ceiling, complete all as specified and directed.
M&L applying two coats of Apex ( Asian Paint) / Weather coat (Berger) over plastered surface including preparation of wall surface over and including 1mm thick wall care putty complete all as specified and directed.
Cutting Chases, pining in, making good to facing where where required and pointing in cement martor 1:3 to ends or edges of landing , steps cills, sunshades, sheleves, lentels etc cutting chases for concealed water tubing or concealed wiring etc making good, cutting exceeding 10 cm but nexc 20 cm girth in brick walls, complete all as specified and directed.
Taking up or down steel tubing and connections 15 mm bore including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing and connections 20 mm bore including cleaning for refixing or removal to store, complete all as specified and directed.
S&F tubes 15 mm bore "medium grade" with and including all fittings & fixed complete to wall and ceilings or laid in floor complete all as specified and directed.
S&F tubes 20 mm bore "medium grade" with and including all fittings & fixed complete to wall and ceilings or laid in floor complete all as specified and directed.
S & F for aluminium anodised sections (conforming to IS) three track sliding window shutter with frames comprising series-C (20mm) , duly fitted with neoprene beading, glazing clipss, locking devices, heat absorbing glass 4.8mm thickness (in 2 shutters) and with SS wire cloth of 0.46mm nominal dia of wire and average width of aperature 1.4mm (in one shutter) including removal of existing unserviceable window complete all as specified and directed.
S&F Aluminium anodised sections ( conforming to IS) door frames with single/double leaf shutters complete duly fitted with neosprene rubber beading,heat absorbing glass panes 4.8 mm nominal thickness at top portion and 3mm thick ACP sheet at bottom panel, Alu anodised with rubber shoe floor door stoppers- 2 Nos, hinges 3Nos in each shutter, Handle 2 Nos in each shutter, Aluminium tower 1 Nos in each shutter and necessary locking arrangement with mortice lock with duplicate keyincluding removal of existing unserviceable door complete all as specified and directed.
M&L for aluminium anodised partition/ventilator fixed with refletive type glass, aluminium section weighting 0.55 kg/m incl necessary joining cleats, glazing clips rubber neospeprene at bottom panel and top panel with wire cloth of 0.46mm nominal dia of wire and average with of aperature 1.4mm complete including removal of existing unserviceable ventilator/partition, complete all as specified and directed.
M & L for Cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) as in levelling coarse, filling and mass concrete, complete all as specified and directed.
S&F rolled setion gde Fe 410 -W (Gde- E- 250) quality as in main and cross beams, hip and jack rafters,purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates incl. rivets or bolt & necessary welding etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in floors and paving n. exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as plinth protection/path and the like complete all as specified and directed.
S & F in repair virteous china wash down water closet pan (pedesatal patter) white (excluding fixing bolts, flushing cistern and flush pipe, complete all as specified and directed.
S&F in repair bib taps for 15 mm bore pipe cast copper alloy chromium plate with crutch or butterfly handle,screwed down, screwed for iron pipe and fixed, complete all as specified and directed.
S & F in repair PVC valveless, syphonic action type 10 ltrs flushing cistern low level white with inlet, ball valve float and handle including brackets complete all as specified and directed.
S&F PVC connection for 15 mm bore pipe (Length 450 mm approx), complete all as specified and directed.
Taking down chowkhats or frames (wooden/aluminium) with shutters without taking off shutter from the frames exc. 1.5 but n. exc 4 sqm each complete all as specified and directed.
Supply and fixing for 12mm thick toughend glass with or without frosted and as in fixed window and including all necessary fixing arrangement like SS clamp/clips, arrangments for fixing etc, including making good the wall surfaces as per existing consitions complete all as specified and directed.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing complete all as specified and directed. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) & removing & rubbish off the premises complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed.
M&L for rendering 10 mm thick on brick work/ concrete surfaces in cement mortar 1:6 on fair faces finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of wall surfaces and applying two coat of oil bound disemper over one coat of oil base primer all as specified on walls surface including a coat of 1.5mm wall care putty, complete all as specified and directed.
M&L plain cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills,steps; seismic and other similar band, copings, covings bed plates, shelves and like including necessary formwork, complete all as specified and directed.
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
S &F 3mm thick aluminium composite panel with aluminium frame and shtter as in door/partition incl glazing clip and neosprene rubber beading, locking arrangment with locking devices complete all as as specified and directed
Taking down carefully aluminium/Copper conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing complete all as specified and directed.
Taking down old unserviceable FTL fitting incluidng rods for taking credit complete all as specified and directed.
Taking down old unserviceable MCB TPN DB/MCB SPN DB including MCBs for taking credit complete all as specified and directed.
Taking down old unserviceable XLPE electric cable 3.5 core 95 sqmm including earth work for taking credit complete all as specified and directed.
M&L point wiring for one light/fan/exhaust fan point controlled by one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surfce as existing same colour complete all as specified and directed.
All as per item No 49 above but on independent board
All as per item No 49 above but on same board
M&L point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly complete all as specified and directed.
S&F Polycarbonate switch piano flush type, SP,5/6 Amps, one way complete all as specified and directed.
S&F Polycarbonate switch piano flush type, SP, 16/20 Amps, one way complete all as specified and directed.
S&F Polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch, complete all as specified and directed.
S&F Polycarbonate socket out let 6 pin, 20 Amps complete all as specified and directed.
M&L ceiling rose, Pilot 3 Plate ceiling rose 6A, complete all as specified and directed.
S&F Ceiling fan regulator electronic type deluxe 240 , 5 step , Volts ISI Marked complete all as specified and directed.
Supply and fixing LED lights fitting 20 watt, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Taking down existing Air conditioning and installing at given location after plastering including servicing of ACs and recharging of gas, replacement of AC power box etc, complete all as specified and directed.
S&F plug and socket DBs with Single pole MCBs rated 20 Amps capacity all as specified or equivalent of other make including making niche in wall and mounted flush complete all as specified and directed.
M&L for concealed sub main wiring comprising two single core, 4 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS Grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 4 Sq mm nominal cross sectional area n green coloure on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tendered).(Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
M&L for concealed sub main wiring comprising two single core, 10 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS Grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 4 Sq mm nominal cross sectional area n green coloure on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tendered).(Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
S&F distribution board TPN ,with and including of DPX MCCB 25 KA 125 amps MCCB FP, as incomer and SP/TPN going protection class IP 54, 8nway (DPX125+24) with metal double door complete all as specified and directed. (Note: FPMCCBs 25KA 125Apms 1No and 24 Nos MCB SP 32 Apms 230 Volts and Blanking plate shall be measured and under this items)
S&F epoxy powder coated distribution box Double door type SPN 8 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door complete all as specified and directed.
S&F MCCB Four pole 160 Amps , 25KA 415 Volts to be housed in existing feeder piller box Properly and suitable size cable lugs to be fixed with MCCB are including in unit rate of each complete all as specified and directed.
S&F MCB SPN, 40 Amps , 240 Volts to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs are including in unit rate of each complete all as specified and directed.
S&F MCB SP 6 to 32 Amps C seires , 240 Volts to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs are including in unit rate of each complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate not less than 1.50 m below ground level, connected to GI lead wire of 4 mm dia. (7.50 m long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 1.5 mm nominal bore (7.50 m Long) for earth plead wire, watering pipe light grade of 20 mm nominal bore, 0.63 mm thick CI funnel, wire mesh etc complete including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 50 mm thick dully reinforced with 6 mm dia, MS round bars @ 100 mm C/C both ways, earth testing point, making good to floor complete all as specified and directed.
S&F XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 3.5 core 95 sqmm complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
Supply and laying un-reinforced precast concrete cable cover, class LV Type 2 flat, size 450mm x 180mm x 40mm, complete all as specified and directed.
Supply and fixing GI pipe 50mm dia light grade with all fittings laid in trenches/walls/floors complete all as specified and directed.
Supply, installation and testing of water cooler capacity 150/150 ltrs fully stainless steel, electric driven, single phase having approx storage and nominal cooling capacity 150 ltrs with drain out pipe etc, complete all as specified and directed.
M K Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .