Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹21.3 L+₹2.4 L (12.8%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹21.4 L+₹2.5 L (13.2%)Rejected-Finance | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹21.8 L+₹3.0 L (15.7%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance HIGHEST | |
| 5 | L5₹22.3 L+₹3.4 L (18.1%)Rejected-Finance | L5 | Rejected-Finance HIGHEST |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
7 Mar 2022, 6:00 pmClosed
GE ARMY BARMER
Military Engineer Services Garrison Engineer Army Jalipa Mil Stn Post box No 53 Barmer 344001
SPL REPAIR TO CSD CANTEEN AND JSA OF BDE AT MIL STN JALIPA UNDER GE ARMY BARMER AND PROVISION OF PATH HARD STANDING AND IRON GATE INFRONT OF 50 BED CRISES EXPANSION WARD IN 177 MH AT JALIPA MIL STN UNDER GE ARMY BARMER
2022_MES_505768_1
GE (A)/BMR-53 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹48,400
8 Mar 2022
4 Feb 2022
8 Mar 2022
4 Feb 2022
7 Mar 2022
18 Feb 2022
Amount
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness(below or above ground level).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Dismantling boarding, any description, fixed in any position with nails.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of GI/CI/DI pipe etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard & dense soil.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L 100mm Plain Cement Concrete type D2 (1:4:8) using 40 mm graded stone aggregate as in sub base in path of hardstanding.
M&L 100mm Plain cement concrete type B2 (1:2:4) using 40 mm graded stone aggregate as in path and Hardstanding.
M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate.
M&L forming 12 mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade'B' (thickness of concrete slb in 100mm)
M&L Forming Construction joint 30mm deep x 10mm wide filled with sealing compound(Grade B)
M&L RCC type B0 (1:2:4) 12.5mm graded aggregate(Nominal mix) in footing and columns.
M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality
M&L Mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality
Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Fair finished surfaces of concrete flat
M&L formwork to sides of pillers,post,struts,piers,column for fair finished surfaces
S&F(Fe-410-W(Gde- E-250) Quality B rolled sections framed work as in doors or gates of angle or other sections with gusset plates,rails,braces,etc complete including hooks and hinges or steel hanging door fittings,hanging ,fastening and fixing complete all as specified and directed.
M&L two coat of synthetic enamel paint over a coat of red oxide on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth on new surfaces complete all as specified and directed.
Rendering 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces for backing coat of wall tile all as specified.
Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation all as specified and directed.
M&L coloured Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement and pigment
M&L 50 mm thick PCC type B-0, (1:2:4) using 20mm graded stone aggregate etc complete.
M&l Virified Ceramic tiles light shade 10 mm thick double charged (square/ rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm screed bed in CM(1:6) complete all as specified and directed.
M&l Virified Ceramic tiles light shade 10 mm thick double charged (square/ rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm screed bed in CM(1:4) as in skirting complete all as specified and directed.
M & L for Preparation of old painted surfaces of wall and applying one coats of cement base paint .
M & L for Preparation of old painted surfaces of wall and applying one coats of distemper oil emulsion white or tintedany colour all as specified and directed.
M&L for complete removal of existing treatement of walls and prepare the wall surface with wall care putty and than applying a coat of primer and over it applying two coat of distemper oil emulsion white or tintedany colour all as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L Providing and fixing 12mm thick Gypsum board in ceiling fixed with metal frame work (Fillets, metal frame work ) as per sample approval painting with two coats of oil bond distemper complete all as specified and directed.
M&L Providing and fixing 10mm thick mineral fiber ceilings board FOR acoustic purpose to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work ) Make: Armstrong and equivalent all as specified and directed .
Supply only in repair floor carpet with fiber material (Woven polypropylene)any colour, ,Pile weight Ca.510 gm/sqm,Pile height 5mm complete including removing old carpet complete all as per specified and directed .
fixing only carpet with adhesive(Fevicol SR 998)including preparation of existing surfaces.(Note: Related material must be provided by contractor only)
M&L preparation of old wooden surfaces and applying tew coat of synthetic enamel paint all as specified and directed.
M&L preparation of old steel surfaces and applying two coat of synthetic enamel paint all as specified and directed.
Dismantling and refixing in same position MS chair complete all as specified and directed .
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down unserviceable main switch/DB, Teak wood boards etc
Taking down submain wiring of any size complete all as directed.
M&L for point wiring in concealed with PVC insulated, unsheathed, single core multistandard copper conductor cable( FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with its acessories including necessary pressed steel terminal boxes flushed in wall and 3 mm thick ISI marked laminated sheet cover and SS screws with cup washers for fixing switches, sockets, fan regulators etc. including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 for one light /CB point controlled by one switch, complete all as specified and as directed.
All as per Srl item No 43 above but for one ceiling fan point controlled by one switch.
All as per Srl item No 43 above but for one 3/2 Pin 5 Amp socket out let point on the independent board.
All as per Srl item No 43 above but for one socket outlet 3/2 pin, 5 Amp, point on the same board with other switches.
All as per Srl item No 43 above but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket point.
All as per Srl item No 43 above but with cable 4 sqmm including 4 sqmm cable as earth wire for 15/16 amp socket point.
Supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 10 A ,240 V complete all as specified and as directed.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and as directed
Supply and fix socket outlet 2in1, 3pin,5A complete all as specified and as directed.
Supply and fix socket outlet 2in1, 3pin,6/16 A complete all as specified and as directed.
Supply and fix switch piano flush type single pole one way 15 Amps complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite 65x50 mm two to three terminals.
Supply and fix step type electronic fan regulator flush type, 230 volt, AC complete.
S&F Supply and fixing single pole 06 to 32 A rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing andcommissioning, complete all as specified and as directed
All as per Srl item No 56 above but SPN 32 A rating complete all as specified and as directed
All as per Srl item No 56 above but TPN 63 A rating complete all as specified and as directed
S&F sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 8 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed.
S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, TPN 4 way with 200 Amps rated bus bar , 415 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed.
Taking down ceiling fan in serviceable condition and refixing the same location after oiling/greasing as required complete all as specified and as directed
M&L sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run o f 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
Taking down and refixing of LED tube light fitting retrived from existing location, in serviceable condition and connectiong up with twin core twisted flexible copper conductor cable of suitable size including all necessary screws clamps and round blockscomplete all as specified and as directed
Taking down and refixing of LED flat panel 2'X2' light fitting retrived from existing false ceiling grid , in serviceable condition and connectiong up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed
Supply and fix in replacement recess mounting low glare LED panellight 36 watt for armstrong/grid ceiling or similar ceiling mounting system with concealed complete prewied using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade complete all as specified and directed. Make: BAJAJ CAT No BZRSQL36WXLNW or Philips, Havells. Note : Rate for removing of existing unservieable old luminaire is deem to be included in this item rates
S & F LED batten suitble for indoor application 20 W, 4' length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed
M & L lamp holder (Angular) PVC/poly carbonate type with back plate suitable for batten fittings
Supply & fix LED lamp 10 W , min lumen output 950 lumens at 6500 K CCT for batten holders complete all as specified and as directed.
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed
Taking down GI water tubing and connections from walls/ceiling/from trenches for clearing of any blockage and relaying or refixing of the same tubing in trenches/ wall/ceilings of size 50 mm dia bore complete all as specified and directed by Engr-in Charge Note: (i) Excavation, earth work and PCC work will be measured and paid separately under relevant items. (ii) The rate quoted must be inclusive of replacing the rusted or damaged collars/Tees/elbows/bends/ unions/nipples if any
Dismantling the existing unserviceable GI tubings and Supply, laying and connection of GI pipe medium grade with all fittings laid in trenches including testing complete all as specified and directed of 50 mm dia size. Note:- Excavation and earth work shall be measured and paid separately
Dismantling the existing unserviceable gate valves ,S & F gun metal globe/gate valve with inner wheel head, screwed both ends for iron pipes and fixed of 50 mm dia size complete all as specified and directed.
M&L cast iron bends (any type, radius and angle) tapers any type. (Straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm bore.
M & L cutting CI/DI pipes in position for insertion of new Tees, branches etc of dia 100 mm complete all as specified and as directed.
Demolition of existing old unserviceable brick masonary valve chamber including demolition of unserviceable M.S iron cover and iron frame and Construction of brick masonry valve pit of size 90cm x 90cm X 90 cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 type D2 ( using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thick sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/ loose soil complete all as shown on drawing and as specified.
Excavation in post holes (or similar holes) each not exc 0.5 cum getting out , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil
Material and labour for sand cushioning for under ground cables, spread in trenches, river sand including cleaning, spreading levelling, punning for laying/cushioning of cable all as directed. with layer of 8 cm deep before laying cable and 15 cm depth after laying and stretching the cable complete all as directed. Note: For the Purpose of payment puned thickness shall be measured.
Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150 mm x 40 mm as mechanical protection to underground cables laying with length of the cable cover across the trench
Supply & Fix GI pipe light grade 40 mm for cable protection fixed to poles/bldg incl two Nos MS clamps made to shape out of 25 x 3mm MS flat and painting incl bolt, nut, washer etc.
Supply and errect steel tubular poles, type-410 SP-22, 8.5 meter long complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and directed.
Supply and replace GI pipe bracket for street light fittings made out of 32 mm dia GI pipe light grade 1.5 mtr long bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size all as directed by Engineer - in - Charge
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling & mass concrete for sub base of poles.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation filling & mass concrete.
M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in copings of poles etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified & directed.
Supply and Laying, connecting all testing and commissioning of XLPE insulated, earthed, screened, PVC bedded, galvanised steel strip or wire armoured electric (heavy duty) with stranded aluminium conductor 1100 volts grade cross sectional area of 16 sqmm 4 core. Note: 1. Exacavation, earth work, sand, bricks and PCC will be measured and paid under relevant items.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fix Thermoplastic cable junction box IP 66 halogen free and weather proof for out door installation( with metric knockouts for cable entry ) of size 139x119x70 mm Make : HENSEL Cat part no KF5065 or eqv make incl taking down old US PVC loop in loop out box complete all as specified and directed.
National Rewinding Works
AMBEY MAA CONSTRUCTION COMPANY
M/S TANUSHREE CONSTRUCTION COMPANY
Devi Engineeing
Kusum Traders
M/s Malinath Electricals
M/s B R Saran Kotda
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .