Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAdmitted-Finance | ₹2.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.6 Cr+₹29.0 L (12.4%)Admitted-Finance | ₹2.6 Cr+₹29.0 L (12.4%) | L2 | Admitted-Finance |
| 3 | L3₹3.2 Cr+₹88.1 L (37.6%)Admitted-Finance S 524 NEELKANTH HOUSE 302 3RD FLOOR SCHOOL BLOCK SHAKARPUR DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | ₹3.2 Cr+₹88.1 L (37.6%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical 401 APOLLO ARCADE R C TECHNICAL INSTITUTE ROAD GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | - | - | Rejected-Technical NOT ACCEPTABLE DUE TO NON MEETING OF TECHNICAL CRITERIA |
| Sl No | Description | Qty | Unit | VECTRAS L2 | CONSULTECH L1 | SANMARG Projects Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|
| 1.003170 - MITIGATION WORKS AC & DC INTERFERENCE-KARNATAKA | ||||||
| 1.01 | Supply, Installation, Testing and Commissioning of NEW bigger size CP test station with terminal board including Liasoning with the land owner, transportation, excavation, concreting as per the as per SOW, SCC & Drawings and as per the directions of EIC | 30 | EA | 17,000 ₹6,01,800 Lowest | 25,000 ₹8,85,000 | 25,095 ₹8,88,363 |
| 1.02 | Supply, Installation, Testing and Commissioning of NEW Bigger size Test Stations on available foundation with terminal board by replacing the existing TLP box including Liaisoning with the land owner, cutting from the existing post and welding the new TLP box at site complete the job in all respects including materials for cutting , welding , arrangement of portable generator, tools and tackles like, as per SOW, SCC & Drawings and as per the directions of EIC | 17 | EA | 19,000 ₹3,81,140 | 15,000 ₹3,00,900 Lowest | 21,193 ₹4,25,131.58 |
| 1.03 | Supply, Installation, Testing and Commissioning of Copper AWG6 (AC MITIGATOR) cable termination, end sealing, including Liasoning with the land owner, transportation, excavation, laying , spreading of backfill material all around 100 mm, watering , back filling of trench and restoration , labour, consumables, tools and tackles as per specifications and as per SOW, SCC & Drawings and as per the directions of EIC. | 6,000 | M | 1,700 ₹1,20,36,000 | 1,650 ₹1,16,82,000 Lowest | 2,207 ₹1,56,25,560 |
| 1.04 | Supply, Installation, Testing and Commissioning of Solid State Decoupler (SSD) - KRISTON MAKE in test station, termination of cable ends, testing and commissioning of solid state decoupler including required terminal lugs, clamps and hard wares as per the specifications and SOW, SCC & Drawings and as per the directions of EIC | 50 | EA | 64,750 ₹38,20,250 | 40,000 ₹23,60,000 Lowest | 69,789 ₹41,17,551 |
| 1.05 | Design, Fabrication, supply & Installation of CORROSION Coupon 1 cm2 with Magnetic read switch, shunt etc. as per NACE SP 0104-2014, in the existing Test Station, for measurment of AC/DC Voltage, Polarised PSP, AC Corrosion etc: Supply & Installation of Polarization Coupons & measurement of AC /DC Current Density. The job shall be carried out as per the scope of work mentioned in the tender document. Installation including all associated electrical, civil (excavation) & mechanical works and any compensation for the crop loss during work execution will be in the scope of Contractor AND as per SOW, SCC & Drawings and as per the directions of EIC | 10 | EA | 14,000 ₹1,65,200 | 4,500 ₹53,100 Lowest | 8,473 ₹99,981.4 |
| 1.06 | Supply, Installation, Testing and Commissioning of gradient Earthing mat at SV station/Customer terminal as per SOW, SCC & Drawings and as per the directions of EIC | 17 | EA | 15,000 ₹3,00,900 Lowest | 25,000 ₹5,01,500 | 15,431 ₹3,09,545.86 |
| 1.07 | Supply & Spreading of Stone/Gravel at SV station/ Customer terminal as per SOW, SCC & Drawings and as per the directions of EIC | 50 | M3 | 1,200 ₹70,800 Lowest | 1,500 ₹88,500 | 2,887 ₹1,70,333 |
| 1.08 | Pin brazing on pipeline for Making pipe to cable connection on pipe line up to the size of 25 sqmm as per the approved procedure including Liasoning with the land owner, required size of pin, excavation, cleaning of surface, Brazing, sealing of connection point and backfilling as per scope of work as per specifications and as per SOW, SCC & Drawings and as per the directions of EIC | 60 | EA | 3,000 ₹2,12,400 Lowest | 4,000 ₹2,83,200 | 3,952 ₹2,79,801.6 |
| 1.09 | Supply and laying of 1core X 6sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC | 600 | M | 250 ₹1,77,000 | 200 ₹1,41,600 Lowest | 204 ₹1,44,432 |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
18 Apr 2024, 2:00 pmClosed
CM(C AND P)
GAIL INDIA LIMITED SWAN 2ND FLOOR, 323, KODIGEHALI MAIN ROAD, SAHAKARNAGAR, BENGALURU
CONTRACT FOR MITIGATION AS PER AC AND DC INTERFERENCE SURVEY REPORT OF DBPL PIPELINE
2024_GAIL_191487_1
GAIL/BLR/23-131/20118430/C AND P
Open Tender
Electrical Works
Works
270 days
GAIL BENGALURU
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹4.2 L
GAIL BENGALURU(THRU VIRTUAL MODE)
20 May 2024
28 Mar 2024
19 Apr 2024
28 Mar 2024
18 Apr 2024
8 Apr 2024
1 Apr 2024
Amount
3170 - MITIGATION WORKS AC & DC INTERFERENCE-KARNATAKA
Supply, Installation, Testing and Commissioning of NEW bigger size CP test station with terminal board including Liasoning with the land owner, transportation, excavation, concreting as per the as per SOW, SCC & Drawings and as per the directions of EIC
Supply, Installation, Testing and Commissioning of NEW Bigger size Test Stations on available foundation with terminal board by replacing the existing TLP box including Liaisoning with the land owner, cutting from the existing post and welding the new TLP box at site complete the job in all respects including materials for cutting , welding , arrangement of portable generator, tools and tackles like, as per SOW, SCC & Drawings and as per the directions of EIC
Supply, Installation, Testing and Commissioning of Copper AWG6 (AC MITIGATOR) cable termination, end sealing, including Liasoning with the land owner, transportation, excavation, laying , spreading of backfill material all around 100 mm, watering , back filling of trench and restoration , labour, consumables, tools and tackles as per specifications and as per SOW, SCC & Drawings and as per the directions of EIC.
Supply, Installation, Testing and Commissioning of Solid State Decoupler (SSD) - KRISTON MAKE in test station, termination of cable ends, testing and commissioning of solid state decoupler including required terminal lugs, clamps and hard wares as per the specifications and SOW, SCC & Drawings and as per the directions of EIC
Design, Fabrication, supply & Installation of CORROSION Coupon 1 cm2 with Magnetic read switch, shunt etc. as per NACE SP 0104-2014, in the existing Test Station, for measurment of AC/DC Voltage, Polarised PSP, AC Corrosion etc: Supply & Installation of Polarization Coupons & measurement of AC /DC Current Density. The job shall be carried out as per the scope of work mentioned in the tender document. Installation including all associated electrical, civil (excavation) & mechanical works and any compensation for the crop loss during work execution will be in the scope of Contractor AND as per SOW, SCC & Drawings and as per the directions of EIC
Supply, Installation, Testing and Commissioning of gradient Earthing mat at SV station/Customer terminal as per SOW, SCC & Drawings and as per the directions of EIC
Supply & Spreading of Stone/Gravel at SV station/ Customer terminal as per SOW, SCC & Drawings and as per the directions of EIC
Pin brazing on pipeline for Making pipe to cable connection on pipe line up to the size of 25 sqmm as per the approved procedure including Liasoning with the land owner, required size of pin, excavation, cleaning of surface, Brazing, sealing of connection point and backfilling as per scope of work as per specifications and as per SOW, SCC & Drawings and as per the directions of EIC
Supply and laying of 1core X 6sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC
Supply and laying of 1core X 10 sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC
Supply and laying of 1core X 25 sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC
DC Interference Monitoring recommended works : Supply, Installation, Testing and Commissioning of NEW TEST BIG STATION and reference electrodes in the SOIL ACCESS TUBE , transportation, excavation, concreting as per the as per SOW, SCC & Drawings and as per the directions of EIC
3165-MITIGATION WORKS AC & DC INTERFERENCE-MAHARASTRA
Supply, Installation, Testing and Commissioning of NEW bigger size CP test station with terminal board including Liasoning with the land owner, transportation, excavation, concreting as per the as per SOW, SCC & Drawings and as per the directions of EIC
Supply, Installation, Testing and Commissioning of NEW Bigger size Test Stations on available foundation with terminal board by replacing the existing TLP box including Liaisoning with the land owner, cutting from the existing post and welding the new TLP box at site complete the job in all respects including materials for cutting , welding , arrangement of portable generator, tools and tackles like, as per SOW, SCC & Drawings and as per the directions of EIC
Supply, Installation, Testing and Commissioning of Copper AWG6 (AC MITIGATOR) cable termination, end sealing, including Liasoning with the land owner, transportation, excavation, laying , spreading of backfill material all around 100 mm, watering , back filling of trench and restoration , labour, consumables, tools and tackles as per specifications and as per SOW, SCC & Drawings and as per the directions of EIC.
Supply, Installation, Testing and Commissioning of Solid State Decoupler (SSD) - KRISTON MAKE in test station, termination of cable ends, testing and commissioning of solid state decoupler including required terminal lugs, clamps and hard wares as per the specifications and SOW, SCC & Drawings and as per the directions of EIC
Design, Fabrication, supply & Installation of CORROSION Coupon 1 cm2 with Magnetic read switch, shunt etc. as per NACE SP 0104-2014, in the existing Test Station, for measurment of AC/DC Voltage, Polarised PSP, AC Corrosion etc: Supply & Installation of Polarization Coupons & measurement of AC /DC Current Density. The job shall be carried out as per the scope of work mentioned in the tender document. Installation including all associated electrical, civil (excavation) & mechanical works and any compensation for the crop loss during work execution will be in the scope of Contractor AND as per SOW, SCC & Drawings and as per the directions of EIC
Supply & Spreading of Stone/Gravel at SV station/ Customer terminal as per SOW, SCC & Drawings and as per the directions of EIC
Pin brazing on pipeline for Making pipe to cable connection on pipe line up to the size of 25 sqmm as per the approved procedure including Liasoning with the land owner, required size of pin, excavation, cleaning of surface, Brazing, sealing of connection point and backfilling as per scope of work as per specifications and as per SOW, SCC & Drawings and as per the directions of EIC
Supply and laying of 1core X 6sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC
Supply and laying of 1core X 10 sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC
Supply and laying of 1core X 25 sq.mm copper armoured cable as per Specifications and SOW, SCC & Drawings and as per the directions of EIC
VECTRAS
SANMARG Projects Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .