Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹7.0 L+₹44,643 (6.76%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹7.1 L+₹48,433 (7.33%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹9.2 L+₹2.6 L (39.4%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Sept 2024, 6:00 pmClosed
GE 863 EWS
GE 863 EWS, C/O 56 APO
REPAIR MAINT SERVICING OF SERVO VOLTAGE STABILIZERS DG SETS LIGHTENING PROTECTION SOLAR STREETS LIGHTS AND OTHER CONNECTED WORKS AT MATIANA AVERIPATTI JHAKRI KARCHAM POARI IN THE AREA OF AGE EM WE POOH UNDER GE 863 EWS
2024_MES_668782_1
GE/863/EWS-T-28 OF 2024-25 REPAIR MAINT SERVICING OF SERVO VOLTAGE
Open Tender
Civil Works
Item Rate
180 days
MATIANA TO POARI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹20,000
Yes
7 Nov 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
27 Sept 2024
14 Sept 2024
Amount
Repair/maintenance and servicing of water cooled/ air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter, checking of defective parts complete, re-commissioning and testing complete all as specified and directed for the following capacities:- Note :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch 'A'/BOQ. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
30 KVA at Averipatti
10 KVA at Jhakri
50 KVA at Karcham
30 KVA at Poari
Supply only element diesel filter with gasket of existing size and model complete all as specified and directed.
Supply only element oil filter with gasket of existing size and model complete all as specified and directed.
Supply only inner and outer air cleaner element of existing size and model complete all as specified and directed.
Suppply only element bypass filter with gasket of existing size and make complete all as specified and directed.
Supply only lubrication oil SAE-40 (20w-40 grade) complete all as specified and directed.
Dismantling/In situ Cleaning and calibration of the fuel tank of various capacities, by using 'K' oil and remove sludge accumulated inside the tank, replacment of fuel tank strainer, cap and unserviceable fuel indicatior including refixing after repair/welding the leakage portions complete all as specified and directed by Engr-in-Charge
S&F in replacement for connecting and testing battery lead (Heavy duty) PVC insulated with multi stranded copper conductor single core of size 25 sqmm one side fixed with clamp and other side fixed with brass battery terminal for 2 mtr length of suitable colour coding for phase and earth complete all as specified and directed.
S&F in replacement of battery maint free type 100Ah complete all as specified and directed.
Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & opening of servo operated oil cooled voltage stabilizer of cap 30 KVA , single/three phase, 50 Hz and draining out of transformer oil, replacement of UNSV/defective wiring parts as per existing sizes, dimmerstat, carbon brush, servo motor of existing capacity, control card, etc and complete servicing including filteration & refilling of transformer oil with top-up of new oil if required, reassembling, connecting and testing complete all as specified and directed by Engr-in-Charge. Note:- Replacment of spare parts/accessories, top-up of transformer oil shall be measured & paid seperately as 'Supply Only' on relevant items.
All as per Ser item No. 10 here in before but of capacity 100 KVA, three phase, complete all as specified and directed by Engr-in-charge. Note:- Replacment of spare parts/accessories, top-up of transformer oil shall be measured & paid seperately as 'Supply Only' on relevant items.
Supply only Dimmerstat as per existing size and make complete all as specified and directed.
Supply only Servo control motor Cap 10 Kgs, 60 RPM & 240 volts for existing voltage stabilizer as per existing size and make complete all as specified and directed.
Supply only Push Buttons for adjustment of voltage complete all as specified and directed.
Supply only Carbon brush as per existing size and make complete all as specified and directed.
Supply only voltmeter digital type, 0-500 volts, 96mm x 96mm square size including wiring, suitable for voltage stabilizers complete all as specified and directed.
Supply only indicator lamp pilot type (RYB) complete all as specified and directed.
Supply only PCB card as per sample complete all as specified and directed.
Supply only Transformer oil EHV conforming to IS-335 of 1983 having high dielectric strength not less than 50KV in drums/barrel complete all as specified and directed.
S&F in replacement of copper strip 20x3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
S&F in replacement of aluminum strip 25 x 3.15 mm thick with & incl suitable porcelain/FRP insulators, saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
S&F in replacement air termination single pointed Copper rod 12mm dia and 300 mm long incl fixing on roof with MS clamp and nut, bolt and washers etc complete all as specified and directed.
S&F in replacement air termination single pointed aluminium rod 12mm dia and 300 mm long incl fixing on roofl with MS clamp and nut, bolt and washers etc complete all as specified and directed.
S&F in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L in replacement for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip 25x4 mm protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc. complete all as specified and directed by Engr-in-charge. Note: 1. Suitable quantity of charcoal, common salt, funnel, GI pipe required for watering, pit & CI pit cover etc is deemed to be included in quoted rate and lead wire used beyond 7.5m from pit cover will be measured separately. 2. On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost.
S & F in replacement of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed.
S & F in replacement of solar street light fitting 15/16 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed.
S&F in replacement of battery maint free type 110Ah suitable for solar light fitting complete all as specified and directed.
Servicing of window / split AC 1.5 / 2 TR capacities any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, rectification of loose electric connections and replacement of unserviceable knobs of electrical items complete all as specified and directed. Note : Replacement of spare parts will be measured and paid separately under relevant items as "Supply only" of Sch 'A'. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
Supply only starting capacitor 80-100 mfd complete all as specified and directed.
Supply only running Capacitor 36 mfd complete all as specified and directed.
Supply only starting relay suitable for AC complete all as specified and directed.
Supply only Over load protector complete all as specified and directed.
Supply only thermostat complete all as specified and directed.
Supply only Air Filter complete all as specified and directed.
Removing the existing defective / short circuited hermetically sealed compressor unit from the ACs and replace with the same company rewound sealed compressor unit of appropiate make / model for 1.5 TR AC complete all as specified and directed by Engr-in-charge.
Servicing, maintenance and repairs to Refrigerator / Deep Freezer of capacity 280 to 500 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed by Engr-in-charge. Note : Replacement of spare parts will be measured and paid separately as "Supply only" under relevant items of Sch 'A'. Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
Supply only starting relay suitable for Refrigerator/Freezer complete all as specified and directed.
Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator cap: 280 to 380 ltrs complete all as specified and directed by Engr-in-charge.
M&L for Gas charging with refrigerant to ACs/water cooler/Deep freezer /Refrigerator including arresting of existing leakage by brazing work complete and all as specified and directed.
Supply and fix in Replacement of voltage stablizer for AC Refrigerator / Deep Freezer, automatic operation/single phase AC supply 230V 50 Hz naturally air cooled indoor type designed for input variation between 130 V to 280 V with output valtage stablizer at 230V with accuracy of (+) or (-) 2.50% and capacity 2 to 5 KVA complete all as specified and directed.
M&L for servicing, cleaning of water purifier 8/10 LPH, any make & model complete all as specified and directed. Note: Replacement of following items shall be measured & paid separately as "Supply only". Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
Supply only Sediment filter for 8/10 LPH water purifier, complete all as specified and directed.
Supply only Carbon filter for 8/10 LPH water purifier, complete all as specified and directed.
Supply only UV filter for 8/10 LPH water purifier, complete all as specified and directed.
Supply only Membrane for 8/10 LPH water purifier, complete all as specified and directed.
Supply only Pre-filter candle for 8/10 LPH water purifier, complete all as specified and directed.
M&L for servicing, cleaning of Industrial type RO plant 50 to 100 LPH, any make & model complete all as specified and directed. Note: Replacement of following items shall be measured & paid separately as "Supply only". Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted.
Supply only pressure regulator for 50 to 100 LPH RO plant, complete all as specified and directed.
Supply only Sediment Pre-filter for 50 to 100 LPH RO plant, complete all as specified and directed.
Supply only Carbon filter for 50 to 100 LPH RO plant, complete all as specified and directed.
Supply only RO membrane for 50 to 100 LPH RO plant, complete all as specified and directed.
Supply only Post Caron inline filter for 50 to 100 LPH RO plant, complete all as specified and directed.
Supply only Pressure pump booster for 50 to 100 LPH RO plant, complete all as specified and directed.
Schedule of Credit
A P ENTERPRISES (BID ID -3097961)
R B TRADERS (BID ID -3096957)
BHUPENDER SINGH (BID ID -3096689)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .