Signalling work in connection with Provision of one additional goods shed line of 750M at Phephna station of BSB division & Provision of Multi section Digital axle counter in Berthing tracks & water logging track portions at BUI & PEP station of Varanasi division.
NER-BSB0SnT-OT-18-2026
NER-BSB0SnT-OT-18-2026
Open
12 Months
Varanasi, Uttar Pradesh
₹0
₹6.7 L
6 Jun 2026
6 Jun 2026
15 Jun 2026
A 1- ELECTRONICS INTERLOCKING
Ballia: -Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuitsand logic of EI system including modification in the VDU (Video Display Unit)/ LCP(Local Control panel)/CCIP (Control cum Indication Panel), Maintenance terminal(MPC), Data Logger, Data logger fault logic, Relay rack wiring, alteration in Fuse alarm and monitoring system, alteration and wiring of 2 KLCR. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material/connectors /fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT or 2nd FAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Inspection- RDSO (for additional cards, if required) Unit Above/
A 2- Outdoor Signalling works
Supply of and Fixing of MS Flat size 32 mm x 5 mm as Earth lead on location boxes and interlocked LC gate of BSB division. All required materials will be supply by the contractor as per the technical specification attached, Inspection- Consignee.
Earthing of CT Rack, Relay Rack, DG sets etc. including supply of Earthing materials as per the technical specification attached, Inspection-Consignee.
Supply of ARA Terminal 1 Way 60 mm asper RDSO Drg. No. SA - 23745 Alt - 5 and Specification No. IRS: S: 75/2006 with latest amendment if any. Inspection: RDSO
Supply of ARA terminal 6 way as per the technical specification attached, Inspection-RDSO.
Supply of Bus bar 50 way as per the technical specification attached, Inspection-Consignee.
Supply of Shunt signal independent type RDSO Drg No. SA 23840 Adv Alt -2 complete with mounting socket to Drg No. SA 23845 but without lamp lenses suitable for 90 mm outside dia pipe Complete with GI pipe 90 mm dia of 1.5 mts and CI base for post as per the technical specification attached, Inspection-Consignee.
Supply of PVC Wire 16x0.2 sq mm as per the technical specification attached, Inspection-Consignee.
Supply of PVC flexible copper cable single core, multistrand 1x6 Sq.mm (84 conductor each diameter0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3), Inspection-Consignee.
Supply of GI Pipe medium grade ISI mark. Inspection : Consignee
Supply of Eyelet 1.5 mm sq. as per the technical specification attached, Inspection - Consignee.
Supply of Eyelet 4 mm sq. as per the technical specification attached, Inspection-Consignee.
Supply of Low Maintenance Secondary Cell 80 AH as per the technical specification attached, Inspection- Consignee.
Supply of Fuse base for NDT fuse as per the technical specification attached, Inspection-RDSO.
NDT low voltage electric fuse non indicating type fuse as per IRS S:78/92 round edge 14 mm dia, 51 mm length rating 2 Amp, Inspection-RDSO.
NDT low voltage electric fuse non indicating type fuse as per IRS S:78/92 round edge 14 mm dia, 51 mm length rating 4 Amp, Inspection-RDSO.
NDT low voltage electric fuse non indicating type fuse as per IRS S:78/92 round edge 14 mm dia, 51 mm length rating 6 Amp, Inspection-RDSO.
PPTC ELECTRONIC FUSE X 30 UF 250 30V 2.5AMP. MAKE TYCO FUSE SHOULD BE SUPPLIED IN CYLINDRICAL CARTRIDGE HAVING SIZE 14 MM DIA 54 MM LENGTH OR SIMILAR. INSPECTION-CONSIGNEE
Supply of Relay Non Ac Immunise Style QTA2 neutral track 9.0 Ohm 2F/1B contacts front and back contacts metal to carbon complete with plug board, retaining clip and connectors as per spec no. BRS - 938A, Inspection-RDSO.
Supply of choke as per RDSO specification no.IRS: S-65/83 with latest amendment if as per the technical specification attached, Inspection-Consignee.
Supply of PBT BASE Track Feed Adjustable Resistance "DISC TYPE" 15/ 30 ohms as per the technical specification attached, Inspection-Consignee.
Supply of Track Feed Battery Charger as per RDSO Spec. No . IRS: S-89/2013 Rev. 1.0 or latest, Inspection- RDSO.
Supply of track lead junction boxes (4-way) made from fibre glass including ARA terminals, MS angle size 40 x 40 x 6 mm of 1 mtr. length & bent pipes as per RDSO Specification No. RDSO/ SPN/ 151/ 1997 or latest. as per the technical specification attached, Inspection-Consignee.
Supply and fixing of P/G/C markers with complete fittings. All material require for the job such as MS sheet ,MS Angle ,Nut and bolts, paint & painting materials will be supplied by the contractor as per direction of site engineer & as per the technical specification attached, Inspection-Consignee.
Supply & Installation of Number Plate of Signals as per the technical specification attached, Inspection- Consignee.
Supply & Installation of wooden box for CHC size 50x40x15 cm made-up of 19 mm plywood board pasted mica glass as per the technical specification attached, Inspection-Consignee.
Supply of Hand Cuff Lock as per CWM S & T W/S GKC Drg no SW/98/8 as per the technical specification attached, Inspection-Consignee.
Transportation of Materials Including Loading and unloading from consignee's store/ any station to other any station/ store as per the technical specification attached.
Supply of Insulated material for ground connection of EPM as per the technical specification attached, Inspection-Consignee.
Installation of Warning board along with supply of warning board. This includes concrete foundation of 600 x 600 x 600 mm as per the technical specification attached, inspection-Consignee. Note -Rail post will be given by railway at the store of consignee.
Installation, Wiring and Testing of EPM Rotary Type as per tech spec attached.
Fabrication and fixing of bond wire by drilling double hole on each side as per the technical specification attached.
Fabrication and fixing of jumper wire by drilling double hole on each side as per the technical specification attached.
Casting of foundation and installation of Apparatus case SINGLE including supply of all material except Apparatus case and JB as per the technical specification attached.
Casting of foundation and installation of Apparatus case HALF including supply of all material except Apparatus case and JB as per the technical specification attached.
Casting of Position type shunt signal including supply of concreting material, erection and fitting of Shunt Signal as per the technical specification attached.
Installation of lever lock DW type fitted with crank Handle /E-type lock /KLCR lock relay assembly and its wiring as per the technical specification attached.
Termination of signalling cable as per the technical specification attached.
Charging of Sec Cell as per the technical specification attached.
Fitting of LED signal with all accessories and its wiring . All material required for fitting and wiring except LED signal and PVC wire shall be supplied by the contractor as per the technical specification attached.
Excavation of cable trench of 110 cm Depth and 30 cm Width in all kind of soils and its refilling with the same excavated soil consolidating by ramming to the level of 20 cm above the ground level over the trench as per the technical specification attached.
Excavation of cable trench of 100 cm Depth and 30 cm Width at level/track crossing and platform and its refilling with the same excavated soil consolidating by ramming to the level of 20 cm above the ground level over the trench as per the technical specification attached.
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 48 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge.
EXCAVATION OF TRENCHLESS TRACKUNDER RAILWAY TRACK/BUSY ROAD ETCAT A DEPTH OF 1.20 METER
Laying of signalling cable ( 2 core to 12 core) in the trench as per cable route plan approved by railway and meggering of all main & tail cables. The cable laying includes laying of cable in trenches as per the technical specification attached.
Laying of 6 quad Cable in the trench as per cable route plan approved by railway as per the technical specification attached.
Laying of GI / HDPE Pipe for passing the cables at level /track crossing and platform etc. Only GI/HDPE pipe and scoket will supplied by railway.Other activity will be done by contractor as per tech. specification.
Installation of Terminal board for terminating main/tail cable including supply of terminal board as per the 54 technical specification attached, inspection-Consignee. Note -(1). Termination board of hylem sheet IS:2036 grade P-4 size 6mm thick. (2). Angle Iron Size 40mm X 40 mm X 5 mm at station. (3) Angle Iron size 25 mm X 25 mm X 3 mm suit the size of cases ie. Single case, Half Case, 50 way JB and as for requirments.
Installation & wiring of track feed charger, choke and track battery as per instruction of site engineer as per the technical specification attached.
Preparation of field diagram such as cable Route plan , Power supply lay out, Cable Termination Chart in relay 56 room & Location Boxes, Location Wiring Diagrams, Fuse Analysis, Equipment Disposition Plan, Track Bounding & Insulation Plan as per Railway practice. Note: All the above Diagrams/Plans to be submitted in Polyster Film Tracing to the railway. The contractor shall also supply 6 sets of Photo/Ferro print copy of said plans/drawings out of which 1 set shall be duly laminated.
Preparation of Station Working Rule (SWR)Including Appendix- A, B , C , D , E , E, F and G in Hindi and English on Approved SIP/ESP/ST/SWRD/PD/VDU Layout etc. asper the Extant Practice being followed in Lucknow Division of N.E. Railway. 57 The Contractor shall Supply Two Paper Print of the SWR as Draft for Approval and Comments. Once the Approval is Given he shall Supply Two Set Paper Prints of the SWR for Final Approval and Signature of the Concerned Officials On obtaining final Approval, The Contractor shall Supply 10Sets of the SWR And 1 Set Gate Working Rule (GWR) of each LC Gate (App.-A) Duly Photocopies of SWR. The Approved SWR shall be Finally Supplied in 2 Pen drives.
Preparation and Printing of Station Working Rule Diagram (SWRD) an Auto Cad based on Approved SIP, ESP etc. 58 as per the extant Practice being followed in Lucknow Division of N.E. Railway. Contractor shall Supply One Print of SWRD (Paper Print Size as Required)as Draft for Approval and comments. Once the Approval is given, Contractor shall Supply Tracing of the SWRD on Good Quality Film Paper of Thickness not Less Than 75Micron for Signature of All Officials. On Approval the Contractor shall Supply 10Copies Blue Print of Tracing. The Approved SWRD shall be Finally Supplied in 2 Pen Drives.
Testing and Commissioning of complete yard both indoor and out door including break down testing w.r.t. selection table /locking table using simulation panel, finally from panel in presence of Railway official as per tech spec.
Painting of Sig. equipments Signals, Apparatus Cases, EPM etc. of complete Yard including supply of paint
Cement concrete work for miscellaneous items in the ratio 1:3:6. Item includes excavation ,ramming, curing and plastering with cement sand mixture (aggregate not exceeding 3.8cm). Aggregate, cement and to be supplied by contractor as per technical specification attached.
Providing Brick masonary in the ratio 1:6 cement &mortar including plastering with 1;4 cement and sand mixture both sides, 20 mm thick each with contractors own 2nd class brick , including excavation curing grouting bolting etc wherever required .Brick sand & cement to be supplied by the contractor as per technical specification attached.
Supply of Multi Section Digital Axle Counter(MSDAC) system including Axle Detectors, Track side electronics, Mushroom /TLJB, Central Evaluators, Reset unit, Relay unit with Final Track clearance relay, Event logger, Diagnostic terminal, 63 Tool kits ,Line verification box for each Track section/ Supervisory Track Section including all OEM racks/accessories fully wired and equipped with 10 Detection points and 08 Track sections as per RDSO Specification No. RDSO/SPN/176/2013 (Ver.3) or latest. Inbuilt cable length of all TX/RX shall be up to 15 meter length (rate to be quoted per MSDAC set of 10 DP/8 TS. The cost of diagnostic terminal/ evaluation software/tool kit, training and Manual etc. as per quantity mentioned in Annexure A is to be added), Inspection-RDSO.
Installation and commissioning of Central Evaluator:- Installation , wiring, testing and commissioning of one 64 Multi Section Digital Axle Counters Indoors Set comprising of processors/central evaluators for section/station/Relay Hut along with supply and installation of Maintenance free Earthing if required for processors/central evaluators including its associated indoor Equipment and wiring of the same to be integrated with existing EI/PI/Auto EI/Local Signalling circuits (one MSDAC set comprises of system fully wired and equipped for 10 DP and 8 TS as detailed in Annexure-A. Per Detection
Installation and commissioning of Detection point:- Installation and commissioning of Detection point installation of complete assembly of track device unit for entry or exit and track side electronic equipment along with supply 65 and installation of Maintenance Free Earthing if required (as detailed in Annexure A) with all materials for fixing the track devices, taking the cable lead through anti rodent, anti oxidant and non flammable propagating type DWC pipe as per IS 14930 Part I or II or latest from track device to location box/mushroom and terminating it terminals including digging of trench under track upto location/track side unit. (All materials required for installation of above equipment are to be supplied by the firm).
Tools Kit for High frequency Digital Axle Counter Multi section. Service test panel including meter for test of 66 track equipment, tools for mounting and adjustment of track equipment and standard jig for drilling holes in rail. It should be as per Principal manufacturers (OEM) recommended list adequate for installation, day to day maintenance, and adjustment of indoor and outdoor gears. This shall also include kit for making and drilling of holes on rail as per technical specification attached, Inspection-Consignee.
"Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197/2008 or latest and conforming to RDSO Drg. No. SDO/ RDSO/E&B/001dtd.19.09.08 . It consist of following: (a) Copper bonded steel electrode of 3.0 m long,17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no.(b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. ©Copper strip of 150x25x6 mm, to terminate 67 earth rod = 1 no. (d)Copper strip of 300x25x6 mm(MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no.(ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room induplicate.(minimum 10 meter)(iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: Consignee.
DISMANTLING OF EXISTING SIGNALS, APPARATUS CASES, FOUNDATIONS, EPM, WIRES, GATES ETC. TRANSPORTATION OF MATERIAL AS PER TECH. SPECN.
Miscellaneous arrangement for NI period comprising of Provision of water-proof temporary goomty/tent at both 71 side of the station yard and at central panel building (upto 5 goomties at each station). Each goomties to be furnished with one iron table, six chairs, emergency light and mosquito repellent caps for NI staff, PA system, crowbar men for operating point and men for supplying water to tents.
Supply of Laptop based work station for data input & configuration, simulation and functional testing, diagnostics and trouble shooting and commissioning of SSI system. Screen-15.6inch, Ram-16 GB, i5 processor, 512 GB PCI eNVMe, Graphics card-NVIDIA GTX 1650 4gb or better configuration. Inspection by Consignee.
Supply of Portable digital auto range multi-meter clamp type with capacity to measure mA AC/DC current with accuracy of (3% of reading) AC/DC upto80Amp(AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms, suitable for measurement of Freq., capacitance, complete with Manual, leads, battery and holster etc. Inspection-Consignee against WC & TC.
Switch Plate lubricant - Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenumdisulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill& lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-to-metal contact. It shall be designed to be hand applied providing 74 a tough adherent Lubricant film with Tacky semi-dry finish reducing contaminant adhesion. The Lubricant Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication Thegrease should Not need Cleaning or scrapping before Reapplication. The Lubricant should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The lubricant shall be Resistant to water wash off & dilution, water insoluble, non-meltand chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosioninhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTM- D2596) >600Kg, Copper corrosion 24 hrs @ 100c(ASTM D 4048) 1a -2e packing Size20 kg /25kg Drum, Inspection-RITES.
Copper lug heavy duty Dowell's make or similar, Inspection-Consignee.
Color LCD Thermal imager pocket size Make Fluke or Similar as per technical specification attached, inspection- Consignee.
Supply of Safety lock Godrej or Navtal make size as approved by site engineer. Inspection: Consignee
Item Breakup - A 1- ELECTRONICS INTERLOCKING
Per Alteration involving modification up to 20 routes. Alteration
Alteration more than 20 routes. Total 8312668.49
Item Breakup - A 2- Outdoor Signalling works
Supply of 4 conducore disconnect terminal blocks RDSO/SPN/189/2004 ver.3.0 or latest, Inspection-Consignee.
Supply of End and Intermediate Plate as per RDSO/SPN/189/2004 Numbers ver.3.0 or latest, Inspection-Consignee.
Supply of screwless End Stop as per RDSO/SPN/189/2004 ver.3.0 or Numbers latest, Inspection-Consignee.
Supply of Steel carrier Rail as per RDSO/SPN/189/2004 ver.3.0 or latest, Numbers Inspection-Consignee. Total 121173.05 Earthing of CT Rack, Relay Rack, DG sets etc. including supply of Earthing materials as per the technical specification attached, Item- 4 Inspection-Consignee. S No. Item Description of Item Unit Qty Rate Amount No
Supply Total 49862.00 Item- 12 Supply of GI Pipe medium grade ISI mark. Inspection : Consignee S No. Item Description of Item Unit Qty Rate Amount No
GI Pipe 100 mm dia medium grade ISI mark
GI Pipe 50 mm dia medium grade ISI mark Total 178480.00 Supply and fixing of P/G/C markers with complete fittings. All material require for the job such as MS sheet ,MS Angle ,Nut and Item- 27 bolts, paint & painting materials will be supplied by the contractor as per direction of site engineer & as per the technical specification attached, Inspection-Consignee. S No. Item Description of Item Unit Qty Rate Amount No
Supply Total 891.34 Item- 29 Supply & Installation of Number Plate of Signals as per the technical specification attached, Inspection-Consignee. S No. Item Description of Item Unit Qty Rate Amount No
Supply Total 1890.85 Installation of Warning board along with supply of warning board. This includes concrete foundation of 600 x 600 x 600 mm as Item- 35 per the technical specification attached, inspection-Consignee. Note -Rail post will be given by railway at the store of consignee. S No. Item Description of Item Unit Qty Rate Amount No
Supply Total 7919.28 Installation of Terminal board for terminating main/tail cable including supply of terminal board as per the technical specification attached, inspection-Consignee. Note -(1). Termination board of hylem sheet IS:2036 grade P-4 size 6mm thick. (2). Angle Iron Item- 54 Size 40mm X 40 mm X 5 mm at station. (3) Angle Iron size 25 mm X 25 mm X 3 mm suit the size of cases ie. Single case, Half Case, 50 way JB and as for requirments. S No. Item Description of Item Unit Qty Rate Amount No
Square Execution Foot
Square Supply Foot Total 123552.00 Item- 69 SHIFTING OF LOCATION BOXES S No. Item Description of Item Unit Qty Rate Amount No
Half Case Total 13635.94 DISMANTLING OF EXISTING SIGNALS, APPARATUS CASES, FOUNDATIONS, EPM, WIRES, GATES ETC. TRANSPORTATION OF Item- 70 MATERIAL AS PER TECH. SPECN. S No. Item Description of Item Unit Qty Rate Amount No
LOCATION BOX SINGLE CASE
LOCATION BOX HALF CASE
FOUNDATION SIGNAL / LOCATION BOXES Total 5536.50 Item- 76 Copper lug heavy duty Dowell's make or similar, Inspection-Consignee. S No. Item Description of Item Unit Qty Rate Amount No
Size 6 sq mm VARANASI DIVISION-S AND T/NORTH EASTERN RLY
Size 16 sq mm Total 22400.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
BUIMiniature.pdf
ATTACHMENT
PEPMiniature.pdf
ATTACHMENT
Annexure-AforMSDAC.pdf
ATTACHMENT
STTenderDoc.pdf
ATTACHMENT
IPASVerificationofBGonlyletter.pdf
ATTACHMENT
JPOforundrtakingearthworkdiggingwork1.pdf JPO for undertaking earth work
ATTACHMENT
Technicalspecification.pdf
ATTACHMENT
JPOforundrtakingearthworkdiggingwork1.pdf
ATTACHMENT
Download all tender documents and submit your bid