| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 45 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST
1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W
2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)
3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L70
4 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 70
5 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w
6 Junction Temperature (T) should be (85°C
7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.0
8 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI)
9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.
10 Power factor ) 0.95% with APFC
11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.
12 CRI of )_70 luminaries
13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road
14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.
15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.
16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-2
17 LED Drive current: up to or ( 1000 mA
18 LED driver efficiency: )_85%
19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs
20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink
21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection
22 Luminaire shall have a separate optical and driver compartment.
23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)
24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable
25 Frequency: 50Hz plus /-3%
26 Operating temperature: Range: -10C to plus 50C
27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-5
28 Working humidity: Preferred 100%, and not less than 95% RH
29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop Test
Electrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`
30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating
31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.
32 Compliance: ROHS /CE/ERTL/ERDI
33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture
34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.
35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 | 3,620 | Each | - | - |
| 2 | 90 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST
1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W
2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)
3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L70
4 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 70
5 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w
6 Junction Temperature (T) should be (85°C
7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.0
8 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI)
9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.
10 Power factor ) 0.95% with APFC
11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.
12 CRI of )_70 luminaries
13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road
14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.
15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.
16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-2
17 LED Drive current: up to or ( 1000 mA
18 LED driver efficiency: )_85%
19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs
20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink
21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection
22 Luminaire shall have a separate optical and driver compartment.
23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)
24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable
25 Frequency: 50Hz plus /-3%
26 Operating temperature: Range: -10C to plus 50C
27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-5
28 Working humidity: Preferred 100%, and not less than 95% RH
29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop Test
Electrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`
30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating
31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.
32 Compliance: ROHS /CE/ERTL/ERDI
33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture
34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.
35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 | 1,300 | Each | - | - |
| 3 | 120 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST
1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W
2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)
3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L70
4 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 70
5 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w
6 Junction Temperature (T) should be (85°C
7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.0
8 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI)
9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.
10 Power factor ) 0.95% with APFC
11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.
12 CRI of )_70 luminaries
13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road
14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.
15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.
16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-2
17 LED Drive current: up to or ( 1000 mA
18 LED driver efficiency: )_85%
19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs
20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink
21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection
22 Luminaire shall have a separate optical and driver compartment.
23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)
24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable
25 Frequency: 50Hz plus /-3%
26 Operating temperature: Range: -10C to plus 50C
27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-5
28 Working humidity: Preferred 100%, and not less than 95% RH
29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop Test
Electrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`
30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating
31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.
32 Compliance: ROHS /CE/ERTL/ERDI
33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture
34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.
35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 | 780 | Each | - | - |
| 4 | 200 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST
1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W
2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)
3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L70
4 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 70
5 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w
6 Junction Temperature (T) should be (85°C
7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.0
8 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI)
9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.
10 Power factor ) 0.95% with APFC
11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.
12 CRI of )_70 luminaries
13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road
14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.
15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.
16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-2
17 LED Drive current: up to or ( 1000 mA
18 LED driver efficiency: )_85%
19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs
20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink
21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection
22 Luminaire shall have a separate optical and driver compartment.
23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)
24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable
25 Frequency: 50Hz plus /-3%
26 Operating temperature: Range: -10C to plus 50C
27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-5
28 Working humidity: Preferred 100%, and not less than 95% RH
29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop Test
Electrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`
30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating
31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.
32 Compliance: ROHS /CE/ERTL/ERDI
33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture
34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.
35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 | 300 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_598162.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .