Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹25.8 L+₹534.50 (0.02%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹27.2 L+₹1.4 L (5.27%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹27.6 L+₹1.8 L (7.06%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹32.3 L+₹6.4 L (25.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
9 Aug 2021, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
PROVN OF STORAGE ACCN NEAR RSS ENCLAVE AND SPECIAL REPAIR TO BLDG NO. PN-31 UNDER GE NAGROTA.
2021_MES_458508_1
GEN-32/2021-22
Open Tender
Civil Works
Item Rate
180 days
NAGROTA
Class D and above and category a (I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹70,000
Yes
30 Sept 2021
9 Jul 2021
11 Aug 2021
9 Jul 2021
9 Aug 2021
24 Jul 2021
Amount
Excavating over area n. exc 1.5m deep and getting out in any type of soil, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil, complete all as specified and directed.
Removing excavated surplus soft/loose soil to a distance not exceeding 50m and depositing where directed and at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Taking down existiong old tarfelt, bituminous compound including cleaning & removing debris to a distance exc. 100m but n. exc 250m complete all as specified and directed
Demolition of brick work / stone masonry built in cement mortar or cement lime mortar including all quoins ,arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each, complete all as specified and as directed at site.
Taking down chowkat with shutter (without taking off shutter from the frame) exceeding 1.5 sqm but not exceeding 4 Sqm each , complete all as specified and as directed at site.
M&L for Providing, cement concrete 1:2:4 type B-0 (12.5mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges or as in padding concrete,complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:4 including water proofing compound @2% of cement over roof surfaces finished even and smooth without using extra cement, complete all as specified and directed. Note:- WPC shall be measured and paid separetly
Supply only integral water proofing compound, complete all as specified and directed.
Apply bituminious primer @ 0.40 liter per Sqm over plastered surfaces of roof including parapet surface, complete all as specified and directed.
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm , complete all as specified and directed.
Apply one layer of APP based polymeric membrane of approved manufacturer, 3mm thick weitht not less than 3.50 kg per Sqm, reinforced with non woven polyester fabric or weitht not less than 150 gms per sqm, Polymeric membrance shall be taken to a height 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing . Note (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturer instructions. (ii) A minimum overlap of 100mm and 75 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufactures insturctions. Note: S&F of APP based polymeric membrance of approved manufacturer will be laid /fixed by authorised person of the same manufactures units as per relevant IS.
M&L for rendering 5mm thick in cement mortar 1: 3 on faces of brick work or concrete surfaces as in ceiling, soffit of chajja finished even and smooth without using extra finished fair and even complete.
M&L for preparing new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:4 including water proofing compound @2% of cement over a coat of cement slurry applied on internal surfaces of wall even and smooth without using extra cement, complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L for 15 mm thick rendering in CM 1:4 including water proofing compound @2% of cement of external surfaces of wall even and smooth without using extra cement, complete all as specified and directed. Note : WPC shall be measured and paid separately.
Prepariton of newly/old plastered or unplastered surfaces of walls and applying two coats of exterior emulsion paint (Apex), complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and 3mm thick wall putty over a coat of primer, complete all as specified and directed
M&L for drilling hole in RCC structures using drilling machine upto a depth of 200mm and 18mm dia, removing dust etc by vacum cleaner and blowers, providing and fixing of heavy grade GI pipe nipple 15 mm dia , 200mm long @1.0 mtr centre to centre in both directions and injection of cement slurry mixed with liquid integral water proofing compound @ 225 gms per 50 kg bag of cement through nipple and closing the ends of nipple with epoxy putty/silica jeelly after injecting the chemicals mixed with cement slurry at any height including necessary scaffoldings, etc complete all as specified and directed
M & L for 5 mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification, complete all as specified and directed.
M & L for Solid PVC wall lining consisting of 5mm thick plain single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete, 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection/paving including finishing surface even and smooth without using extra cement, complete all as specified and directed.
M&L for Brick work with sub class 'B' (old size) bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1 : 6 for parapet walls/railings/manholes/drains etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in surface channel and drains, complete all as specified and directed
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concete, using extra cement, including forms, moulds, mitred/stopped end etc. complete all as specified and directed
M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in kneelers,coping, band, bed plates and similar items including weathering slightly rounded or chamferred angles and throughting, complete all as specified and directed.
S&F anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed
Anodised aluminium powder coating door shutters aluminium section weighing 0.55 Kg/m incl necessary joining cleat, glazing clip,ruber neoprene packing handle 2 Nos in each door hing anodised aluminum snap beading screws etc completed all as specified and directed
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. completed all as specified and directed
S&F double floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass , other parts made of steel heavy duty complete all as specified and directed
S&F for Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg , aluminium( Die cast) body, fixed in repair , all as specified and as directed by Engr-in- Charge.
S&F in repairs Brass mortice lock vertical type with 4 levers 100mm size with decorative brass handle complete all as specified and directed.
S&F 5.5 mm thick sheet glass ordinary quality and glazing with aluminium snap beading in square and fixed to aluminium sections, all as specified and as directed.
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L for joint free Non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 018 sqm but n exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over, complete all as specified and directed.
M&L for 15mm thick screed bed or bedding layer in cement mortar 1:6 on floors for laying floor finish, complete all as specified and as directed.
M & L for chequered cement concrete tiles 25 mm thick set, joined and pointed in neat cement slurry in floors with grey cement and no pigment over and including 15 mm thick screed bed or bedding layer in CM 1:4, and 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4, complete all as specified and directed.
M&L for sand filling under floor or in foundation including watering and consolidation, complete all as specified and directed.
M&L for RCC, M-25, design mix (using 20 mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundation beams, plinth beams etc, concrete all as specified and directed.
M&L for RCC, M-25, design mix (using 20 mm graded crushed stone aggregates) as in columns , concrete all as specified and directed.
M&L for RCC, M-25, design mix (using 20 mm graded crushed stone aggregates) as in floor or roof beam , concrete all as specified and directed.
Use and waste formwork to sides of column complete all as specified.
Use and waste formwork for foundations beams etc for rough finished surfaces complete all as specified.
Use and waste of formwork to sides and doffits of floor or roof beam, beam hauchings, girder, bressum-mers, lintels, cantilivers, shelves incl supports overhangs, etc alos splay between floors and beams etc for rough finished surfaces complete all as specified and directed
Anti-termite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
Anti-termite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed
Anti-termite treatment by treating back fill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of substructure in contact with backfill to be measured) complete all as specified and directed
Anti-termite treatment by treating the soil along with external perimeter of wall below concrete or masonery apron using chemical emulsion at the rate of 2.25 litres per linear metre including drillling an plugging holes etc in aporn complete all as specified and directed
Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete. all as specified and directed
Mild Steel TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete. all as specified and directed
Mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L for preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified.
S & F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coveing/cladding to wall,fixed with self tapping screws/L-type or J-type or cranked hook bolts in lieu of screw as per manufacturer instruction, complete all as specified and directed. Note:- any damage to flooring (which is already fixed in building) during execution of work to be repaired by contractor at his own cost without any cost to department.
S & F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coveing/cladding to wall fixed,ridge with self tapping screws/L-type or J-type or cranked hook bolts in lieu of screw as per manufacturer instruction, complete all as specified and directed. Note:- any damage to flooring (which is already fixed in building) during execution of work to be repaired by contractor at his own cost without any cost to department.
M&L for Hardcore of guage not exceeding 63mm, broken stone/boulders deposited, spread and levelled in layers not exceeding 15 cm thick watered and well rammed to a ture surface broken stone/boulder complete all as specified and directed
M & L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base, complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in flooring/hard standing finished concrete surface even and rough, complete all as spd and directed
M&L for 20 mm thick screed bed or bedding layer in cement mortar 1:4 on floors for laying floor finish, complete all as specified and as directed.
M & L for rendering 10 mm thick in CM 1:3 as in backing layer for laying of tile in vertical surfaces, complete all as specified and directed.
M&L 20-25 mm machine cut kota stone slabs in flooring over cement screed base laid and jointed with grey cemnt slurry mixed with pigment to match the sade of the slab incluidng rubbing and polishing complete all as specified and directed
All as per ser item No.66 here in above but in riser of steps, skirting, dado and pillar
M&L for Preparation of new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and directed Engineer-in-charge.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for preparing newly plastered sufaces of wall and applying three coats of white wash compelete all as specified and directed
S&F MS falt iron as in hold fast and similar small srrticles , cut to length, bent ot shape, driled hole and fixed with screw etc conforming to Fe-410-0 or Fe 310-0 compelte all as specified and directed
M&L for PCC 1:3:6 type C-1 (using 20mm graded saggregate) as in hold fast complete all as specified and directed
M&L for 40 mm thick cement concrete 1:2:4 type B-0 as in DPC to horizontal or vertical surfaces including necessary form work complete all as specified and directed
S&F Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm complete all as specified and directed.
S & F 35 mm thick second class hard wood, factory made, glazed and skelton shutters, open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamered or rounded, fitted with cut and mitred beads for securing glass, etc. Size of memebers of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) for doors, complete all as specified and directed.
S & F 40 mm thick second class hard wood, factory made, framed panelled shutters(any numbers of panels) with panels of timber falt on both sides (feather edged) or of veneered particle board medium density , wood particle board with commerical face veneers fitted to chowkhats, complete all as specified and directed.
S&F factory made Box type Steel window/ventilators top hung double shutters (inside for wire mesh & out side for glass), including hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS complete all as shown on drawing No CEUZ/TD/1302/09, Sh 1/3 to 3/3, complete all as specified and directed. Note : Wire mesh and sheet glass shall be measured and paid separately.
S & F 3.00 mm thick Sheet glass ordinary quality and glazing in square n exc 0.5 Sqm in each pane, complete all as specified and directed.
S & F Galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm dia and fixed with tinned tacks or galvanised mild steel staples, complete all as specified and directed.
S & F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed.
S & F 100 mm long butt hinges, medium wight cold rolled mild steel, complete all as specified and directed.
S & F 150 mm aluminium handles cast type anodized, complete all as specified and directed.
S&F 300 mm mild steel oridinary rat tail rod pattern springs including roller and roller plates, complete all as specified and directed.
M&L for prepration of wood or wooden based new or previously untreated surface of any description, over 10 cm width or gridth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
GI T Grid system in 600 x 600 mm module which includes providing and fixing wall angle along the perimeter of the room with nylon sleeves and wooden screws at 300 mm centre to center. Suspendeding the main tee of size from the soffit, soffit cleat, rawl plugs and wire rod & leveling spring clip at 1200mm center to center cross tee, interlockined into the pre-cut slots in the main tees at 600 mm centre to center in direction perpendicular to the main tee to make a grid of 600x 1200mm. Finally 600 mm cross tees are interlocked in the pre cut slots in the 1200mm tees at 1200 mm center to center in direction parallel to the main tee. Cross Tees having length more than 600 mm are to be supported independently. 6 mm thick aquesostic tile square edge of size 595x595 mm shall be placed into the grid size of 600x600mm. (a) Main T-24x32 thickness 0.3 mm and length 3600. (b) Cross T-24x25 thickness 0.3 mm and length 1200. (c) Cross T-24x25 thickness 0.3 mm and length 1600. (d) Wall angle - 24x24 thickness 0.4 mm and length 3000.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep in any type of soil, complete all as specified and directed.
M & L for Cement concrete 1:5:10 Type E-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
M&L for Cement concrete tiles 30cm x 30cm x 25mm thick, machine pressed, set jointed and pointed in neat cement slurry as in floors with white cement and pigments etc. complete all as specified and directed.
Taking down carefully aluminium conductor point wiring (light fan, socket and power) complete with fittings such as switches, sockets, lamps holder, utility light fitting, fan regulator etc and making good disturbed surface of walls and floors etc. and keeping in safe custody for taking credit, complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan any sweep, removing blades, cleaning the fan completly for dust and dirt and hanging the same back to its original position including connecting the 3 core flexible copper wire to ceiing rose etc after the completion the point wiring including replacement old unservicable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed by Engineer in charge.
Taking down old unserviceable TPN DB with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
Taking down old unserviceable SPN DB with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
Taking down unserviceable sub main wiring including wooden batten/PVC conduit of any size, complete, all as specified and directed by Engr-In-Charge.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly, complete all as specified and directed for the following:-
One light point controlled by one switch 5 Amp.
One wall fan/exhaust fan point controlled by one switch 5Amp
One socket outlet 5 Amp controlled by one switch on independent board.
One bell point 5 Amp controlled by one bell push on independent board.
All as per item No.94 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board.
S&F switch piano flush type 5 Amps single pole one way, complete all as specified and directed.
S&F socket outlet combination 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and directed.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type, complete all as specified and directed.
S&F of ceiling rose 3 terminal PVC/Polycarbonate isolated body, complete all as specified and directed.
S&F stepped type electronic fan regulator flush type 300 watt, 230 volts, 50Hz AC on the existing phenolic laminated sheet etc as required, complete all as specified and directed.
S&F bell push piano type 5 Amps complete all as specified and directed
S&F electric bell ding dong 230 volts AC complete all as specified and directed
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F 7 watt LED bulb complete all as specified and directed
S&F 18 watt LED tube light alongwith fixture complete all as specified and directed
S & F LED light fitting bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, complete all as specified and directed.
Supply & fix Ceiling Fan, 1200 mm sweep , 230 Volts AC supply complete with electronic type regulator and accessories, complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure distribution board SPN 4 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
S & F Sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCB as incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification, complete all as specified and directed.
S&F Sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete complete all as specified and directed
S & F MCB SPN 63 Amps, 10 KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB single pole 40 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB single pole 6 to 32 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB double pole 6 to 32 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCCB 125 Amp, 4 Pole, 16 KA, 415 volts, with fixed magnetic and fixed thermal setting, complete all as specified and directed.
S&F sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm drawing through in existing conduit including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed.
S & F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB SP 32 Amps, complete all as specified and directed.
Supply and laying or fixing including removing of existing cable 1100 volts grade cable PVC insulated aluminium conductor un-armoured of 10 Sqmm 2 core flat or circular, served with inner sheathing of pace tape and overall PVC sheathed in service connection suspended by insulated hangers not more than one Mtr apart including 4 mm dia suspension GI wire, complete all as specified and as directed by Engr-in-Charge.
Supply and laying or fixing including removing of existing cable 1100 volts grade cable PVC insulated aluminium conductor un-armoured of 16 Sqmm 2 core flat or circular, served with inner sheathing of pace tape and overall PVC sheathed in service connection suspended by insulated hangers not more than one Mtr apart including 4 mm dia suspension GI wire, complete all as specified and as directed by Engr-in-Charge.
S&F wall mounted busbar chamber 415V, 3 phase 4 wire, 50 Hz AC supply system fabricated from stainless steel with 3mm thick for outer cell TPN aluminium busbar of capacity 100 Amp 4 pole 8 ways complete all as specified and directed
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
M&L powder coated perforated cable tray 18 SWG 250 mm width and 50mm height including fixing on wall with all necessary clamp and part , nuts, bolts, etc and complete all as specified and directed
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs.12,958.50 during AOC Note:- Tenderers shall not quote for this Schedule
RAJINDRA ENGINEERS & CONTRACTORS
BHARTI CONSTRUCTIONS
R.K. Works
M/S Shankardass Devidass
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .