Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹30.8 LAccepted-AOC 00 VIDYUT NAGAR MEERANPUR SADDARALI TANDA AMBEDKAR NAGAR UTTAR PRADESH 224238 | AMBEDKAR NAGAR | UTTAR PRADESH | 224238 | L 1 | Accepted-AOC AFTER NEGOTIATION CONTRACT VALUE | |
| 2 | L 2₹60.9 L+₹2.1 L (3.66%)Rejected-Finance | L 2 | Rejected-Finance L 2 BIDDER | |
| 3 | L 3₹62.3 L+₹3.5 L (5.93%)Rejected-Finance | L 3 | Rejected-Finance L 3 BIDDER |
Tender Value
₹30.8 L
EMD Value
₹40,000
Closing Date
9 Dec 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE OMC-IV BTPS PTPP
O/o SE OMC-IV BTPS PTPP
Routine, Preventive, Breakdown maintenance HT motors (Ranging from 340 KW to 3600 KW) and LT motors(Ranging from fractional KW to 160 KW) and repair, rewinding of LT motors Ranging from fractional KW to 160 KW of Unit 3 4 of PTPP Parichha Jhansi.
2022_RVUNL_750404_1
ET-01/EMD-II/BTPS/PTPP/2022-23
Open Tender
Electrical Works
Lump-sum
365 days
2X210MW PTPP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Dy. CAO, CFA BO, PTPP, Parichha
₹40,000
19 Jan 2023
18 Nov 2022
9 Dec 2022
18 Nov 2022
9 Dec 2022
18 Nov 2022
Amount
Routine Maintenance of 0.4 KV LT motors of Unit-3, Unit-4 & SOME MOTORS 0F 2X110 MW and Common Auxiliaries (BOP). As per scope of work Sr. No.1, 1 to 24
Round the clock maintenance of all 0.4 KV electrical system, switchgears/MCCs/LTACB/modules/control panels etc of 2X110 MW units ,PTPP As per scope of work Sr. No.2, 1 to 14
Routine Maintenance of various capacities of 6.6 KV motors ranging from 340 KW to 3600 KW of unit of Unit # 3 & 4 PTPP Parichha As per scope of work Sr. No.3, 1 to 9
ELECTRICAL BREAKDOWN MAINTENANCE OF Category-A 340 TO 3600 KW 6.6 KV Mill, FD, CEP, ACW, TAC motors
Proper tightening of stator copper leads, Tail cables, brass connectors and main cables etc inside cable connection box of motor at motor end as per scope of works Sl. No.4 A, 1 to 6 for Category A motor
Proper tightening of cable connections at breaker end as per scope of works Sl. No.4 B, 1 to 6 for Category A motor.
Disconnection and re-connection of 6.6 KV cable connections at motor end as per scope of works Sl. No.4 C, 1 to 6 for Category A motor.
Disconnection and re-connection of 6.6 KV cable at breaker end as per scope of works Sl. No.4 D, 1 to 7 for Category A motor.
Measuring of 6.6 KV motor & cable insulation resistance (IR) value by 2.5/5 KV megger as per instruction of concerned AE/JE. Measuring IR value of motor for 1min and 10min time for measuring polarization index of motor to ascertain the healthiness of motor as per scope of works Sl. No.4 E, 1 to 10 for Category A motor.
Repairing of stator copper cable end of 6.6 KV Motor as per scope of work Sl. No.4 F, 1 to 8 for Category A motor.
Replacement of Brass terminal connector/tail copper cable/FRP moulding joint box/nylon gland part as per scope of work Sl. No.4 G, 1 to7 for Category A motor.
ELECTRICAL BREAKDOWN MAINTENANCE OF Category-B 340 TO 3600 KW 6.6 KV PA, ID, CW, BFP motors
Proper tightening of stator copper leads, Tail cables, brass connectors and main cables etc inside cable connection box of motor at motor end as per scope of works Sl. No.4 A, 1to 6 For category B motor.
Proper tightening of cable connections at breaker end as per scope of works Sl. No.4 B, 1 to 6 For category B motor.
Disconnection and re-connection of 6.6 KV cable connections at motor end as per scope of works Sl. No.4 C, 1 to 6 For category B motor.
Disconnection and re-connection of 6.6 KV cable at breaker end as per scope of works Sl. No.4 D, 1 to 7 For category B motor.
Measuring of 6.6 KV motor & cable insulation resistance (IR) value by 2.5/5 KV megger as per instruction of concerned AE/JE. Measuring IR value of motor for 1min and 10min time for measuring polarization index of motor to ascertain the healthiness of motor as per scope of works Sl. No.4 E, 1 to 10 For category B motor.
Repairing of stator copper cable end of 6.6 KV Motor as per scope of work Sl. No.4 F, 1 to 8 for Category B motor.
Replacement of Brass terminal connector/tail copper cable/FRP moulding joint box/nylon gland part as per scope of work Sl. No.4 G, 1 to7 for Category B motor.
Replacement of C.T. of Neutral side as per scope of work Sl. No.4 H, 1 to 5 for Category B motor.
Removal & installation of neutral side CT connection box as per scope of work Sl. No.4 I, 1 to 9 for Category B motor.
BREAKDOWN MAINTENANCE OF 0.4 KV(LT) MOTORS of EMD-I as per scope of work Sl. No.5 , 1 to 15
Removal of 3 Phase , 700 RPM, 240 Watt LT motor from its foundation and installation after completion of work
Removal of 3 Phase , 900 RPM, 500 Watt LT motor from its foundation and installation after completion of work
Removal of 3 Phase , 0.37 KW to 1.0 KW LT motor from its foundation and installation after completion of work
Removal of 3 Phase, 1.1 KW to 1.5 KW LT motor from its foundation and installation after completion of work
Removal of 3 Phase, 2.2 KW to 3.75 KW LT motor from its foundation and installation after completion of work
Removal of 3 Phase, 7.5 KW LT motor from its foundation and installation after completion of work
Removal and installation of 3 Phase , 0.37 KW to 1.0 KW LT motor fan/coupling/ bearing from /on rotor shaft.
Removal and installation of 3 Phase, 1.1 KW to 1.5 KW LT motor fan/coupling/ bearing from /on rotor shaft
Removal and installation of 3 Phase, 2.2 KW to 3.75 KW LT motor fan/coupling/ bearing from /on rotor shaft
Removal and installation of 3 Phase, 7.5 KW LT motor fan/coupling/ bearing from /on rotor shaft
O/H of 3 Phase , 700 RPM, 240 Watt LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase , 900 RPM, 500 Watt LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 0.37 KW to 1.0 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 1.1 KW to 1.5 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 2.2 KW to 3.75 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
O/H of 3 Phase, 7.5 KW LT motor by shifting, dismantling, assembling & resifting to its foundations for installation
Rewinding of 3 Phase , 700 RPM, 240 Watt LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase , 900 RPM, 500 Watt LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 0.37 KW to 1.0 KW LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 1.1 KW to 1.5 KW LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 2.2 KW to 3.75 KW LT motor with new copper wire exactly similar to original winding
Rewinding of 3 Phase, 7.5 KW LT motor with new copper wire exactly similar to original winding
Repairing of 3 Phase , 700 RPM, 240 Watt DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase , 900 RPM, 500 Watt DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 0.37 KW to 1.0 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 1.1 KW to 1.5 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 2.2 KW to 3.75 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Repairing of 3 Phase, 7.5 KW DE/NDE side bearing housing by re-metalizing & machining to original size
Providing new shaft for 3 Phase , 700 RPM, 240 Watt motors
Providing new shaft for 3 Phase , 900 RPM, 500 Watt motors
Providing new shaft for 3 Phase, 0.37 KW to 1.0 KW motors
Providing new shaft for 3 Phase, 1.1 KW to 1.5 KW motors
Providing new shaft for 3 Phase, 2.2 KW to 3.75 KW motors
Providing new shaft for 3 Phase, 7.5 KW motors
Re-metalizing and machining of rotor shaft to get its original shape & size. (0.37 KW to 7.5 KW motors).
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work (up to 1 KW motor)
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work (1 KW to 5 KW motor)
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work (5 KW to 10 KW motor)
Replacement of gasket of 6.6 KV motor’s CT box & cable connection box at motor end
Overhauling of bearing vapour exhauster fan & motor as per scope of work
Replacement of cooler grass and water pipes by new one of ID fan motor external cooler
PART-B(I)-RATE SCHEDULE OF OVERHAULING OF LT MOTORS: as per scope of work Sr. No. 6,Part-B-1, 1 to 18
LT Motors from fractional KW to 1 KW
LT Motors above 1 KW to 5 KW
LT Motors above 5 KW to 10 KW
LT Motors above 10 KW to 20 KW
LT Motors above 20 KW to 40 KW
LT Motors above 40 KW to 55 KW
LT Motors above 70 KW to 90 KW
LT Motors above 90 KW to 110 KW
LT Motors above 140 KW to 160 KW
PART B(II)-OVERHAULING OF 220 V DC MOTORS:as per scope of work Sr. No. 6,Part-B-II, 1 to 17
13 KW, 220 V DC motor.
30 KW, 220 V DC motor.
PART B(III)-SUPPLY AND REPLACEMENT OF BEARING (DE &NDE side)(skf make) WITH COMPLETE OVERHAULING IN HIGH SPEED MOTORS:as per scope of work Sr. No. 6,Part-B-III, 1 to 20 Note: The pymentof following bearing shall be given to the contractor only after providing GST invoice of procured bbearing.
Compressor motor (Bearing no 6217 C4 ) /AOP motor (Bearing no 6314 2RS )
Hydrant pump (Bearing no.6319 C3)
AOP motor,TGDMCW (Bearing no 6317 C3).
Seal air fan motor(Bearing no 6213 2RS & 6313 2RS).
AC Scanner fan motor (Bearing no 6206 ZZ /6306 ZZ & 6205 ZZ).
PART B(IV)-REPAIRING OF MOTOR TERMINAL PLATE AND LEADS OF LT MOTORS:as per scope of work Sr. No. 6,Part-B-IV, 1 to 2
LT Motors above 5 KW to 20 KW
LT Motors above 20 KW to 40 KW
LT Motors above 40 KW to 70 KW
LT Motors above 70 KW to 90 KW
LT Motors above 90 KW to 125KW
LT Motors above 125KW to 160 KW
PART B(V)-(a)SHIFTING OF LT MOTORS(FROM FOUNDATION TO GROUND & GROUND TO FOUNDATION:as per scope of work Sr. No. 6, Part-B-V, a.
LT Motors above 5 KW to 20 KW
LT Motors above 20 KW to 40 KW
LT Motors above 40 KW to 70 KW
LT Motors above 70 KW to 90 KW
LT Motors above 90 KW to 125KW
LT Motors above 125KW to 160 KW
(b)SHIFTING OF LT MOTORS(FROM ITS FOUNDATION TO CONTRACTORS WORK SHOP / CENTRAL STORE TO SITE & SHIFTING BACK TO ITS FOUNDATION) as per scope of work Sr. No. 6, Part-B-V, b.
LT Motors above 5 KW to 20 KW
LT Motors above 20 KW to 40 KW
LT Motors above 40 KW to 70 KW
LT Motors above 70 KW to 90 KW
LT Motors above 90 KW to 125KW
LT Motors above 125KW to 160 KW
PART B(VI)-BREAK DOWN MAINTENANCE OF RC FEEDER ASSEMBLY WITH MOTOR OVERHAULING as per scope of work Sr. No. 6, Part-B-VI, 1 to7.
Breakdown Maintenance of RC Feeder assembly with motor overhauling.
Repairing of bearing housing of eddy current clutch. as per scope of work Sr. No. 6, Part-B-VI, b.
Rewinding of 03 phase LT squirrel cage induction motor as per scope of work Sr. No. 6, Part-C-I, 1 to 16.
Rewinding of electro magnetic brake coil as per original size with similar wire and insulating material
Fractional KW up to 0.5KW
Above 0.5 KW to 1 KW
Above 1.0 KW up to 2.2 KW
Above 2.2 KW up to 3.7 KW
Above 3.7 KW up to 7.5 KW
Above 7.5 KW up to 11.0 KW
Above 11.0 KW up to 18.5 KW
Above 18.5 KW up to 22.0 KW
Above 22.0 KW up to 37.0 KW
Above 37.0 KW up to 45.0 KW
Above 45.0 KW up to 55.0 KW
Above 70.0 KW up to 90.0 KW
Above 90.0 KW up to 110.0 KW
Above 135.0 KW up to 150.0 KW
Above 150.0 KW up to 160.0 KW
Rewinding of 03 phase LT slip ring induction motor as per scope of work Sr. No. 6, Part-C-I, 1 to 16.
Rewinding of stator of 03 phase LT slipring induction 1.5 kw motor
Rewinding of stator of 03 phase LT slipring induction 5.5 kw motor
Rewinding of stator of 03 phase LT slipring induction 15 kw motor
Rewinding of stator of 03 phase LT slipring induction 45 kw motor
Rewinding of rotor of 03 phase LT slipring induction 1.5 kw motor
Rewinding of rotor of 03 phase LT slipring induction 5.5 kw motor
Rewinding of rotor of 03 phase LT slipring induction 15 kw motor
Rewinding of rotor of 03 phase LT slipring induction 45 kw motor
Repair, rewinding of 220 V DC motors ranging of 5.5 KW to 30 KW as per scope of work Sr. No. 6, Part-C-II, 1 to 17.
Rewinding of Armature winding (Rotor) of 13KW 220 V DC motor
Rewinding of Armature winding (Rotor) of 30KW 220 V DC motor
Rewinding of Field winding (Stator) of 13KW 220 V DC motor
Rewinding of Field winding (Stator) of 30KW 220 V DC motor
Replacement of commutator of 13KW 220 V DC motor
Replacement of commutator of 30KW 220 V DC motor
Replacement of brush holder set with carbon brush of 13KW 220 V DC motor
Replacement of brush holder set with carbon brush of 30KW 220 V DC motor
Providing new terminalplate and fitting on the motor. as per scope of work Sr. No. 6, Part-D-1.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Providing new shorting copper link and fitting on the motor. as per scope of work Sr. No. 6, Part-D-2.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
providing and fitting of new terminal box. as per scope of work Sr. No. 6, Part-D-3.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Repairing of bearing seat (incuding both DE as well as NDE side ) by remetalizing on complete 01 No. rotor shaft and machining to the original sizes of rotor shaft inner race bearing as per scope of work Sr. No. 6, Part-D-4.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Removal of DE/NDE side bearing for inspection and checking and installation of bearing as per scope of work Sr. No. 6, Part-D-5.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Repairing of DE/NDE side motor end covers by remetalizing and machining to the size of outer race of bearing and fitting new bush in end covers of motor as per scope of work Sr. No. 6, Part-D-6.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Replacement of damaged metallic cooling fan by new metallic cooling fan as per scope of work Sr. No. 6, Part-D-7.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
providing and fitting of new metalic cooling fan cover on motor. as per scope of work Sr. No. 6, Part-D-8.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Repairing of damaged key groove on rotor shaft and providing new key as per original sizes on the key on the rotor at coupling portion as per scope of work Sr. No. 6, Part-D-9.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Repairing of broken foundation base of motor as per scope of work Sr. No. 6, Part-D-10.
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
providing and fitting new grease plate. as per scope of work Sr. No. 6, Part-D-11.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Replacement of damaged stator lead with lugs by stator glass insulated copper flexible conductor winding new leads and copper lugs as per original lead as per scope of work Sr. No. 6, Part-D-12.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Complete restaggering of stator core of damaged motor by complete dismantling, repairing/ replacement of damaged laminated stampings by new laminated stampings to eliminate hot spot/ rubbing of stator core as per scope of work Sr. No. 6, Part-D-13.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Dynamic balancing of rotor at 500 RPM by dynamic balancing machine as per scope of work Sr. No. 6, Part-D-14.
Upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Replacement of damaged end cover DE/NDE of LT motor by new end cover as per scope of work Sr. No. 6, Part-D-15.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Replacement and Providing new shaft as per scope of work as per scope of work Sr. No. 6, Part-D-16.
upto 1KW
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Above 10 KW upto 20 KW
Above 20 KW upto 30 KW
Above 30KW upto 40 KW
Above40 KW upto 55 KW
Above 70 KW upto 90 KW
Above 90 KW upto 110 KW
Above 140 KW upto 160 KW
Mechanical works on DC motors as per scope of work Sr. No. 6, Part-E a to f .
Providing new terminal plate with shorting copper link and fitting on the motor for 13 KW 220 V DC motor
Repairing of DE/NDE bearing seat by re-metalizing on rotor shaft and machining to the original sizes of rotor shaft inner race bearing for 13 KW 220 V DC motor
Repairing of DE/NDE side motor end covers by re-metalizing and machining to the size of outer race of bearing and fitting new bush in end covers of motor. New bush for end covers of motor shall be supplied by the contractor as per size of bearing outer race for 13 KW 220 V DC motor
Replacement of damaged metallic cooling fan by new metallic cooling fan. New metallic cooling fan will be supplied by the contractor at his own cost for 13 KW 220 V DC motor
Removal of DE/NDE side bearing for inspection and checking and installation of bearing by replacing damaged bearing by new bearing. New bearings shall be provided by the department for 13 KW 220 V DC motor
Dynamic balancing of rotor at 500 RPM by dynamic balancing machine for 13 KW 220 V DC motor
Providing new terminal plate with shorting copper link and fitting on the motor for 30 KW 220 V DC motor
Repairing of DE/NDE bearing seat by re-metalizing on rotor shaft and machining to the original sizes of rotor shaft inner race bearing for 30 KW 220 V DC motor
Repairing of DE/NDE side motor end covers by re-metalizing and machining to the size of outer race of bearing and fitting new bush in end covers of motor. New bush for end covers of motor shall be supplied by the contractor as per size of bearing outer race for 30 KW 220 V DC motor
Replacement of damaged metallic cooling fan by new metallic cooling fan. New metallic cooling fan will be supplied by the contractor at his own cost for 30 KW 220 V DC motor
Removal of DE/NDE side bearing for inspection and checking and installation of bearing by replacing damaged bearing by new bearing. New bearings shall be provided by the department for 30 KW 220 V DC motor
Dynamic balancing of rotor at 500 RPM by dynamic balancing machine for 30 KW 220 V DC motor
Replacement of damaged insulated end cover of LT motor(above 140 kw upto 160 kw) by new insulated end cover of LT motor as per scope of work Sr. No. 6, Part-F
Repairing of damaged insulated end cover of LT MOTOR (above 140 kw upto 160 kw) by moulding & cutting of glass texolite & epoxy resin to the size of outer race of bearing as per scope of work Sr. No. 6, Part-G
Retrofit work charge of 630 amp capacity LT Air Circuit Breaker in place 75/90 KW capacity LT module of Main Plant/BOP of 2x210MW. as per scope of work Sr. No. 6, Part-G , 1 to 15
Erection & Commissioning work of Microprocessor Based m pro-200 Motor Protection Relay. as per scope of work Sr. No. 6, Part-H, 1 to 7
Providing menpower for overhauling/servicing of LT ACB of main plant/BOP as per scope of work Sr. No. 6, Part-I
Complete Dismantling and assembling of transformer at plant area. as per scope of work Sr. No. 6, Part-J-1
Cost of new coil with super enamel DGC conductor. as per scope of work Sr. No. 6, Part-J-2
COST OF class’F” insulation and Epoxy mounting of coil as per scope of work Sr. No. 6, Part-J-3
Cost of new lead and lugand replacement of any damaged nuts and bolts of T/F as per scope of work Sr. No. 6, Part-J-4
Cost of fibre plate with nut and bolts.(bakelite sheet) as per scope of work Sr. No. 6, Part-J-5
Preventive maintenance of 0.4 KV L.T. Motors as per scope of work Sr. No. 7
Motors up to 25 KW
Motors above 25 KW to 45 KW
Preventive maintenance of 0.4 KV L.T. Modules as per scope of work Sr. No. 7
Emergency Breakdown of flash over in 0.4 KV L.T. Modules.
Overhauling of 0.4 KV L.T. Motors as per scope of work Sr. No. 7
Motors up to 10 KW
Motors above 10 KW to 20 KW
Motors above 20 KW to 25 KW
Motors above 25 KW to 45 KW
Overhauling of 0.4 KV L.T. Modules.
Dismantling and assembling of 0.4 KV L.T. Motors as per scope of work Sr. No. 7
Motors up to 10 KW
Motors above 10 KW to 20 KW
Motors above 20 KW to 25 KW
Motors above 25 KW to 45 KW
Rewinding of 0.4 KV L.T. Motors:
Motors up to 5 KW
Motors above 5 KW to 10 KW
Motors above 15 KW to 25 KW
Motors above 25 KW to 45 KW
Shifting of motors from site to workshop and vice versa from 7.5 KW to 45 KW as per scope of work Sr. No. 7
Providing and fitting of new Terminal Plate in 0.4 KV L.T. Motors as per scope of work Sr. No. 7
Motors up to 10 KW
Motors above 10 KW to 25 KW
Motors above 25 KW to 45 KW
Providing and fitting of new Terminal Box in 0.4 KV L.T. Motors as per scope of work Sr. No. 7
Motors up to 10 KW
Motors above 10 KW to 25 KW
Motors above 25 KW to 45 KW
Providing and fitting of new bush in each end cover of the motor as per size of bearing outer race in 0.4 KV L.T. Motors:
Motors up to 10 KW
Motors above 10 KW to 25 KW
Motors above 25 KW to 45 KW
Providing and fitting of Metalizing of Bearing sheet on Rotor shaft and machining as per bearing inner race of 0.4 KV L.T. Motors:
Motors up to 10 KW
Motors above 10 KW to 25 KW
Motors above 25 KW to 45 KW
Providing and replacing damaged leads:
Motors up to 10 KW
Motors above 10 KW to 25 KW
Motors above 25 KW to 45 KW
M/S Vikas Electricals
M/S MADHU CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .