Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC N 4 NS 4 PLOT NO 6 7 OPP PUNDLIK NAGAR WATER TANK AURANGABAD 431 001 | AURANGABAD | AURANGABAD | MAHARASHTRA | 431001 | ₹39.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹40.6 LRejected-AOC RM182 BAJAJ NAGAR MIDC WALUNJ CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | ₹40.6 L | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical PLOT NO 25 SAICHARAN NAVIN BHIMASHANKAR COLONY BEED BYPASS CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | AURANGABAD | MAHARASHTRA | - | - | Rejected-Technical Work Done Certificate Not as per NIT |
| Sl No | Description | Qty | Unit | RAJLAXMI ELECTRICAL L2 | Tirupati Electricals Sales & Services L1 |
|---|---|---|---|---|---|
| 1.00 | Servicing and overhauling of motors including removing from location dismantling cleaning the winding , drying applying varnish, backing, changing the bearing if necessary ( bearing will be supplied by MIDC) greasing the bearing, assembling and giving satisfactory trials on No load and full load etc
415 volts 3 Phase upto 5 Hp | 14 | Number | 1 ₹14 | 4,500 ₹63,000 |
| 2.00 | 415 volts 3 Phase upto 6 Hp to 10 Hp | 4 | Number | 8,500 ₹34,000 | 4,800 ₹19,200 |
| 3.00 | 415 volts 3 Phase upto 25 Hp to 35 Hp | 6 | Number | 12,500 ₹75,000 | 8,455 ₹50,730 |
| 4.00 | 415 volts 3 Phase upto 40 Hp to 50 Hp | 3 | Number | 22,500 ₹67,500 | 15,400 ₹46,200 |
| 5.00 | 415 volts 3 Phase upto 60 Hp to 100 Hp | 1 | Number | 28,500 ₹28,500 | 18,400 ₹18,400 |
| 6.00 | 415 volts 3 Phase upto 300 Hp to 400 Hp | 4 | Number | 65,000 ₹2.6 L | 44,800 ₹1.8 L |
| 7.00 | Servicing and overhauling of 3.3 KV, 1100 HP double squirrel induction motor, including removing from location, dismantling cleaning the winding, drying, applying, varnish, baking, changing the bearing if necessary (bearing will be supplied by MIDC free of cost) greasing the bearing, assembling, and giving satisfactory trials on No load and full load etc. | 4 | Number | 1,65,000 ₹6.6 L | 2,49,000 ₹10.0 L |
| 8.00 | Rewinding and repairs of Squirrel cage induction motors, 440 V, 3 phase, 50 cycles/sec. 1500 RPM with B class insulation including baking, varnishing, painting etc. (The scrap of winding material shall be retained by rewinder.
60 HP | 1 | Number | 30,000 ₹30,000 | 67,900 ₹67,900 |
| 9.00 | 350/400 HP | 2 | Number | 1,60,000 ₹3.2 L | 2,24,000 ₹4.5 L |
| 10.00 | Rewinding of electric motor above 1 HP and upto 2 HP three phase upto 1400 RPM of all types and makes with copper wire conforming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year | 3 | each | 2,000 ₹6,000 | 1,890 ₹5,670 |
Tender Value
Refer Docs
EMD Value
₹39,400
Closing Date
20 Nov 2025, 11:00 amClosed
Superintending Engineer, MIDC Circle Office, Chhat
Superintending Engineer, MIDC Circle Office, Chhatrapati Sambhajinagar.
M AND R to Shendra - Jalna water supply scheme at Khodegaon. Rewinding, repairing and servicing of induction motors for water supply scheme.
2025_MIDC_1242481_1
16/D/02
Open Tender
Electrical Works
Jalna
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,850
₹39,400
26 Dec 2025
8 Nov 2025
24 Nov 2025
8 Nov 2025
20 Nov 2025
12 Nov 2025
8 Nov 2025 - 11 Nov 2025
Amount
Servicing and overhauling of motors including removing from location dismantling cleaning the winding , drying applying varnish, backing, changing the bearing if necessary ( bearing will be supplied by MIDC) greasing the bearing, assembling and giving satisfactory trials on No load and full load etc 415 volts 3 Phase upto 5 Hp
415 volts 3 Phase upto 6 Hp to 10 Hp
415 volts 3 Phase upto 25 Hp to 35 Hp
415 volts 3 Phase upto 40 Hp to 50 Hp
415 volts 3 Phase upto 60 Hp to 100 Hp
415 volts 3 Phase upto 300 Hp to 400 Hp
Servicing and overhauling of 3.3 KV, 1100 HP double squirrel induction motor, including removing from location, dismantling cleaning the winding, drying, applying, varnish, baking, changing the bearing if necessary (bearing will be supplied by MIDC free of cost) greasing the bearing, assembling, and giving satisfactory trials on No load and full load etc.
Rewinding and repairs of Squirrel cage induction motors, 440 V, 3 phase, 50 cycles/sec. 1500 RPM with B class insulation including baking, varnishing, painting etc. (The scrap of winding material shall be retained by rewinder. 60 HP
Rewinding of electric motor above 1 HP and upto 2 HP three phase upto 1400 RPM of all types and makes with copper wire conforming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 2 HP upto 3 HP three phase upto 1400 RPM of all types and makes with copper wire conforming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 3 HP upto 5 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 5 HP upto 7.5 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 7.5 HP upto 10 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 12.5 HP upto 15 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 25 H.P. upto 30 HP three phase up to 1400 RPM of all types and makes with copper wire conforming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of Auto transformers including dismantling, rewinding with new insulated copper wire/strips of proper size, varnishing/ backing and filling with fresh transformer oil, painting assembly and testing of works and delivery at site. 41 HP to 60 HP
Supplying heavy duty connection plate for 60 HP motor as per old sample.
Supplying heavy duty connection plate for motors up to 400 HP as per old sample
Providing, dismentling and repairing to rotor of 3.3 KV, 1100 HP, 1475 rpm, VT pump motor for replacement of copper bars connected through stampings and both end new brass rings connecting to all the copper bars including all labour and material etc complete. (The old scrap shall be retained by agency)
Repairing to the thrust bearing seat of 400/200 HP motor on shaft OR in housing including filling the size by either welding or fixing new bush of required size of required material and then machining to the required bearing size etc complete including all required labour and material etc complete.
Balancing of the rotor of 400 HP Motor on balancing machine including all required weights, dismentalling complete motor from its location, removing from stator, transportation to workshop and again back to site, reassembling the motor, erecting and giving satisfactory test and trial etc complete including all required labour and material etc complete
Repairing to the thrust bearing seat of 60 HP motor on shaft OR in housing including filling the size by either welding or fixing new bush of required size of required material and then machining to the required bearing size etc complete including all required labour and material etc complete.
Balancing of the rotor of 60 HP Motor on balancing machine including all required weights, dismentalling complete motor from its location, removing from stator, transportation to workshop and again back to site, reassembling the motor, erecting and giving satisfactory test and trial etc complete including all required labour and material etc complete.
Supplying and erecting of SS body, glycerine filled pressure gauge of required capacity as per old sample for Centralised water supply scheme at Waluj.
Supplying and erecting of U tube of SS material for fixing the pressure gauge at the required location as per instructions of the engineer-in-charge including all labours and materials etc. Complete.
Supplying and erecting of controlling valve of SS material for fixing the pressure gauge at the required location as per instructions of the engineer-in-charge including all labours and materials etc. Complete
Supplying and erecting of high pressure metal hose pipes of 1/2" dia and of required length (Minimum 2 feet) as per old sample for water cooling system of thrust bearing of 1100 HP pumps at jackwell as per instructions of the engineer-in-charge including all labours and materials etc. Complete.
Supplying SKF make general purpose bearing grease in 5 Kg. packings with catalogue no. LGMT 2/5 as per specifications of SKF etc complete.
Supplying SKF make high load wide temperature grease in 5 Kg. packings with catalogue no. LGWM 2/5 as per specifications of SKF etc complete.
Supplying SKF make special purpose gear oil in 20 Liters packings with catalogue no. LGMT 2/5 as per specifications of SKF etc complete.
Transformer oil sample testing
Transformer oil filtration
Repairing of OLTC AVR EE-301 EMCO
Labour charges for removing of faulty AVR with all control wiring and fixing of AVR and Tap position indicator complete control wiring and testing etc. comp;lete
Supply of following Drive End (DE) and Non Drive End (NDV ) Bearing for 400HP and 1100HP VT pumps . Supply of SKF Make Cylindrical Roller Bearing - NU 320 ECM/C3 (DE)
Supply of SKF Make Deep Grove Ball Bearing - 7320 BE (NDE)
Supply of SKF Make Deep Groove Ball Bearing 6324 / C3 (DE)
Supply of SKF Make 7319 BM (NDE)
RAJLAXMI ELECTRICAL (BID ID -7035430)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_2143323.xls
BOQ • 0.30 MB
ItemSpecification.pdf
Other Document • 0.04 MB
TenderDocument.pdf
Tender Documents • 0.32 MB
Download all tender documents and submit your bid